Correction: Taliaferro, L. et al. Evaluation of the Broad-Range PCR-Electrospray Ionization Mass Spectrometry (PCR/ESI-MS) System and Virus Microarrays for Virus Detection. Viruses 2014, 6, 1876-1896

Laboratory of Retroviruses, Division of Viral Products, Center for Biologics Evaluation and Research, U.S. Food and Drug Administration, 8800 Rockville Pike, HFM-454, Bethesda, MD 20892, USA
*
Author to whom correspondence should be addressed.
Current address: Division of Infectious Diseases and Vaccinology, School of Public Health, University of California Berkeley, 50 University Ave, Berkeley, CA 94720, USA;
Viruses 2014, 6(11), 4664-4665; https://doi.org/10.3390/v6114664
Submission received: 19 November 2014 / Accepted: 20 November 2014 / Published: 24 November 2014
(This article belongs to the Section Animal Viruses)
We have noted some inaccuracies in Table 1 and Table 2 of our article “Evaluation of the Broad-Range PCR-Electrospray Ionization Mass Spectrometry (PCR/ESI-MS) System and Virus Microarrays for Virus Detection” (Viruses 2014, 6, 1876–1896) [1].
In Table 1, the heading “LLMDA” was omitted and needs to be added to correctly align the results obtained using the LLMDA and the ViroChip with their corresponding results. Additionally, the 10−7 RNA dilution sample needs to be corrected to indicate that it was not tested (nt) in the presence of 105 cell equivalents of Sf9 total nucleic acids (+105) by the PLEX-ID.
In Table 2, the results for LLMDA need to be corrected to indicate that 10−4 RNA dilution was tested and found to be negative, whereas the 10−6 RNA dilution was not tested (nt).
Below you will find the corrected Table 1 and Table 2 for our recently published article [1]. We apologize to the readers of Viruses for any inconvenience this may have caused.
Table 1. Limit of detection using XMRV RNA panel.
Table 1. Limit of detection using XMRV RNA panel.
SamplePLEX-IDLLMDAVirochipRT-PCR a
RNA Dilution bTCID50/mLParticles/µL c(−)Sf9+105(−)Sf9+105(−)Sf9(−)Sf9+105
10−3101.5312+++nt dnt++
10−4100.531.2+++nt+++
10−510−0.53.12+++-++-
10−610−1.50.312--+-+--
10−710−2.50.0312-nt-nt---
a Results from nested PCR with XMRV gag primers; b Viral RNA dilution series were spiked into RNase/DNase free water [(−)Sf9] or present (+) in 105 or 104 cell equivalents of Sf9 total nucleic acids; c Calculated based upon RT activity determined by TSF-PERT assay; d Not tested.
Table 2. Limit of detection using SFV-1 RNA panel.
Table 2. Limit of detection using SFV-1 RNA panel.
SamplePLEX-IDLLMDART-PCR a
RNA Dilution bTCID50/mLParticles/µL c(−)Sf9(−)Sf9+104(−)Sf9+105+104
10−3102.5402nt dntnt++nt
10−4101.540.2-+-+-+
10−5100.54.02-+----
10−610−0.50.402--nt--nt
a Results from nested PCR with SFV-1 gag primers; b Viral RNA dilution series were spiked into RNase/DNase free water [(−)Sf9] or present (+) in 105 or 104 cell equivalents of Sf9 total nucleic acids; c Calculated based upon RT activity determined by TSF-PERT assay; d Not tested.

Reference and Notes

  1. Taliaferro, L.P.; Galvin, T.A.; Ma, H.; Shaheduzzaman, S.; Williams, D.K.; Glasner, D.R.; Khan, A.S. Evaluation of the broad-range PCR-electrospray ionization mass spectrometry (PCR/ESI-MS) system and virus microarrays for virus detection. Viruses 2014, 6, 1876–1896. [Google Scholar]

Share and Cite

MDPI and ACS Style

Taliaferro, L.P.; Galvin, T.A.; Ma, H.; Shaheduzzaman, S.; Williams, D.K.; Glasner, D.R.; Khan, A.S. Correction: Taliaferro, L. et al. Evaluation of the Broad-Range PCR-Electrospray Ionization Mass Spectrometry (PCR/ESI-MS) System and Virus Microarrays for Virus Detection. Viruses 2014, 6, 1876-1896. Viruses 2014, 6, 4664-4665. https://doi.org/10.3390/v6114664

AMA Style

Taliaferro LP, Galvin TA, Ma H, Shaheduzzaman S, Williams DK, Glasner DR, Khan AS. Correction: Taliaferro, L. et al. Evaluation of the Broad-Range PCR-Electrospray Ionization Mass Spectrometry (PCR/ESI-MS) System and Virus Microarrays for Virus Detection. Viruses 2014, 6, 1876-1896. Viruses. 2014; 6(11):4664-4665. https://doi.org/10.3390/v6114664

Chicago/Turabian Style

Taliaferro, Lanyn P., Teresa A. Galvin, Hailun Ma, Syed Shaheduzzaman, Dhanya K. Williams, Dustin R. Glasner, and Arifa S. Khan. 2014. "Correction: Taliaferro, L. et al. Evaluation of the Broad-Range PCR-Electrospray Ionization Mass Spectrometry (PCR/ESI-MS) System and Virus Microarrays for Virus Detection. Viruses 2014, 6, 1876-1896" Viruses 6, no. 11: 4664-4665. https://doi.org/10.3390/v6114664