PEEK with Reinforced Materials and Modifications for Dental Implant Applications
Abstract
1. Introduction
2. What Is PEEK?
3. PEEK Reinforcement
4. Surface Modification of PEEK for Osseointegration
5. Conclusions
Acknowledgments
Author Contributions
Conflicts of Interest
References
- Brånemark, P.I.; Adell, R.; Breine, U.; Hansson, B.O.; Lindstrom, J.; Ohlsson, A. Intraosseous anchorage of dental prostheses. I. Experimental studies. Scand. J. Plast. Reconstr. Surg. 1969, 3, 81–100. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lautenschlager, E.P.; Monaghan, P. Titanium and titanium alloys as dental materials. Int. Dent. J. 1993, 43, 245–253. [Google Scholar] [PubMed]
- Renouard, F.; Nisand, D. Impact of implant length and diameter on survival rates. Clin. Oral Implants Res. 2006, 17, 35–51. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lee, W.T.; Koak, J.Y.; Lim, Y.J.; Kim, S.K.; Kwon, H.B.; Kim, M.J. Stress shielding and fatigue limits of poly-ether-ether-ketone dental implants. J. Biomed. Mater. Res. B Appl. Biomater. 2012, 100, 1044–1052. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Huiskes, R.; Ruimerman, R.; Van Lenthe, G.H.; Janssen, J.D. Effects of mechanical forces on maintenance and adaptation of form in trabecular bone. Nature 2000, 405, 704–706. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Schalock, P.C.; Menné, T.; Johansen, J.D.; Taylor, J.S.; Maibach, H.I.; Lidén, C.; Bruze, M.; Thyssen, J.P. Hypersensitivity reactions to metallic implants-Diagnostic algorithm and suggested patch test series for clinical use. Contact Dermat. 2012, 66, 4–19. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Nakamura, K.; Kanno, T.; Milleding, P.; Ortengren, U. Zirconia as a dental implant abutment material: A systematic review. Int. J. Prosthodont. 2010, 23, 299–309. [Google Scholar] [PubMed]
- Özkurt, Z.; Kazazoğlu, E. Zirconia dental implants: A literature review. J. Oral Implantol. 2011, 37, 367–376. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Akagi, K.; Okamoto, Y.; Matsuura, T.; Horibe, T. Properties of test metal ceramic titanium alloys. J. Prosthet. Dent. 1992, 68, 462–467. [Google Scholar] [CrossRef] [Scilit]
- Kelly, J.R.; Denry, I. Stabilized zirconia as a structural ceramic: An overview. Dent. Mater. 2008, 24, 289–298. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Eschbach, L. Nonresorbable polymers in bone surgery. Injury 2000, 31, 22–27. [Google Scholar] [CrossRef] [Scilit]
- Fujihara, K.; Huang, Z.M.; Ramakrishna, S.; Satknanantham, K.; Hamada, H. Performance study of braided carbon/PEEK composite compression bone plates. Biomaterials 2003, 24, 2661–2667. [Google Scholar] [CrossRef] [Scilit]
- Fujihara, K.; Huang, Z.M.; Ramakrishna, S.; Satknanantham, K.; Hamada, H. Feasibility of knitted carbon/PEEK composites for orthopedic bone plates. Biomaterials 2004, 25, 3877–3885. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kurtz, S.M.; Devine, J.N. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 2007, 28, 4845–4869. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kurtz, S.M. PEEK Biomaterials Handbook; Elsevier Science: Waltham, MA, USA, 2012; pp. 30–31. [Google Scholar]
- Andreiotelli, M.; Wenz, H.J.; Kohal, R.J. Are ceramic implants a viable alternative to titanium implants? A systematic literature review. Clin. Oral Implants Res. 2009, 20, 32–47. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Skinner, H.B. Composite technology for total hip arthroplasty. Clin. Orthop. 1988, 235, 224–236. [Google Scholar] [CrossRef] [Scilit]
- Manish, G.; Chandu, G.; Sunil, K.M.; Siddharth, G. Titanium allergy: A literature review. Indian J. Dermatol. 2014, 59, 630. [Google Scholar]
- Wang, H.; Xu, M.; Zhang, W.; Kwok, D.T.; Jiang, J.; Wu, Z.; Chu, P.K. Mechanical and biological characteristics of diamond-like carbon coated poly aryl-ether-ether-ketone. Biomaterials 2010, 31, 8181–8187. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Becker, W.; Doerr, J.; Becker, B.E. A novel method for creating an optimal emergence profile adjacent to dental implants. J. Esthet. Restor. Dent. 2012, 24, 395–400. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Koutouziz, T.; Richardson, J.; Lundgren, T. Comparative soft and hard tissue responses to titanium and polymer healing abutments. J. Oral Implantol. 2011, 37, 174–182. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Val, J.E.M.S.D.; Gómez-Moreno, G.; Martínes, C.P.A.; Ramírez-Fernández, M.P.; Granero-Marín, J.M.; Gehrke, S.A.; Calvo-Guirado, J.L. Peri-implant tissue behavior around non-titanium material: Experimental study in dogs. Ann. Anat. 2016, 206, 104–109. [Google Scholar]
- Santing, H.J.; Meijer, H.J.A.; Raghoebar, G.M.; Özcan, M. Fracture strength and failure mode of maxillary implant-supported provisional single crowns: A comparison of composite resin crown fabricated directly over PEEK abutments and solid titanium abutments. Clin. Implant Dent. Relat. Res. 2012, 14, 882–889. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sandler, J.; Werner, P.; Shaffer, M.S.; Demchuk, V.; Altstädt, V.; Windle, A.H. Carbon-nanofibre-reinforced poly(ether ether ketone) composites. Compos. Part A Appl. Sci. Manuf. 2002, 33, 1033–1039. [Google Scholar] [CrossRef] [Scilit]
- Schwitalla, A.D.; Emara, M.A.; Spintig, T.; Lackmann, J.; Müller, W.D. Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone. J. Biomech. 2015, 48, 1–7. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Najeeb, S.; Zafar, M.S.; Khursid, Z.; Siddiqui, F. Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J. Prosthodont. Res. 2016, 60, 12–19. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rust-Dawicki, A.M.; Cook, S.D. Preliminary evaluation of titanium-coated PEEK implants. J. Oral Implantol. 1995, 21, 75–77. [Google Scholar]
- Wiesli, M.G.; Med, M.D.; Özcan, M. High-performance polymers and their potential application as medical and oral implant materials: A review. Implant Dent. 2015, 24, 448–457. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lewinstein, I.; Banks-Sills, L.; Eliasi, R. Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis. Int. J. Oral Maxillofac. Implants 1995, 10, 355–366. [Google Scholar] [PubMed]
- Vallittu, P. Some aspects of the tensile strength of unidirectional glass fibre-polymethyl methacrylate composite used in dentures. J. Oral Rehabilit. 1998, 25, 100–105. [Google Scholar] [CrossRef] [Scilit]
- Zafar, M.S.; Ahmed, N. Nanoindentation and surface roughness profilometry of poly methyl methacrylate denture base materials. Technol. Health Care 2014, 22, 573–581. [Google Scholar] [PubMed]
- Martin, R.; Ishida, J. The relative effects of collagen fiber orientation, porosity, density, and mineralization on bone strength. J. Biomech. 1989, 22, 419–426. [Google Scholar] [CrossRef] [Scilit]
- Rho, J.Y.; Ashman, R.B.; Turner, C.H. Young’s modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements. J. Biomech. 1993, 26, 111–119. [Google Scholar] [CrossRef] [Scilit]
- Borchers, L.; Reichart, P. Three-dimensional stress distribution around a dental implant at different stages of interface development. J. Dent. Res. 1983, 62, 155–159. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Staines, M.; Robinson, W.; Hood, J. Spherical indentation of tooth enamel. J. Mater. Sci. 1981, 16, 2551–2556. [Google Scholar] [CrossRef] [Scilit]
- Rees, J.; Jacobsen, P. The elastic moduli of enamel and dentine. Clin. Mater. 1993, 14, 35–39. [Google Scholar] [CrossRef] [Scilit]
- Cavalli, V.; Giannini, M.; Carvalho, R.M. Effect of carbamide peroxide bleaching agents on tensile strength of human enamel. Dent. Mater. 2004, 20, 733–739. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chun, K.J.; Choi, H.H.; Lee, J.Y. Comparison of mechanical property and role between enamel and dentin in the human teeth. J. Dent. Biomech. 2014, 5, 1–7. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Sheets, C.G.; Earthmann, J.C. Natural intrusion and reversal in implant assisted prosthesis: Evidence of and a hypothesis for the occurrence. J. Prosthet. Dent. 1993, 70, 513–520. [Google Scholar] [CrossRef] [Scilit]
- Sarot, J.R.; Contar, C.M.M.; Cruz, A.C.C.D.; Magini, R.S. Evaluation of the stress distribution in CFR-PEEK dental implants by the three-dimensional finite element method. J. Mater. Sci. Mater. Med. 2010, 21, 2079–2085. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Schwitalla, A.D.; Spintig, T.; Kallage, I.; Müller, W.D. Pressure behavior of different PEEK materials for dental implants. J. Mech. Behav. Biomed. Mater. 2016, 54, 295–304. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rabiei, A.; Sandukas, S. Processing and evaluation of bioactive coatings on polymeric implants. J. Biomed. Mater. Res. Part A 2013, 101, 2621–2629. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Barkamo, S.; Wennerberg, A.; Hoffman, M.; Kjellin, P.; Breding, K.; Handa, P.; Stenport, V. Nano-hydroxyapatite-coated PEEK implants: A pilot study in rabbit bone. J. Biomed. Mater. Res. Part A 2013, 101, 465–471. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Suska, F.; Omar, O.; Emanuelsson, L.; Taylor, M.; Gruner, P.; Kinbrum, A.; Hunt, D.; Hunt, T.; Taylor, A.; Palmquist, A. Enhancement of CRF-PEEK osseointegration by plasma-sprayed hydroxyapatite: A rabbit model. J. Biomater. Appl. 2014, 29, 234–242. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wu, X.; Liu, X.; Wei, J.; Ma, J.; Deng, F.; Wei, S. Nano-TiO2/PEEK bioactive composite as a bone substitute material: In vitro and in vivo studies. Int. J. Nanomed. 2012, 7, 1215–1225. [Google Scholar]
- Wang, N.; Li, H.; Lü, W.; Li, J.; Wang, J.; Zhang, Z.; Liu, Y. Effects of TiO2 nanotubes with different diameters on gene expression and ossointegration of implants in minipigs. Biomaterials 2011, 32, 6900–6911. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wang, L.; He, S.; Wu, X.; Liang, S.; Mu, Z.; Wei, J.; Deng, F.; Deng, Y.; Wei, S. Polyetheretherketone/nano-fluorohydroxyapatite composite with antimicrobial activity and osseointegration properties. Biomaterials 2014, 35, 6758–6775. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Najeeb, S.; Khurshid, Z.; Matinlinna, J.P.; Siddiqui, F.; Nassani, M.Z.; Baroudi, K. Nanomodified Peek Dental Implants: Bioactive Composites and Surface Modification—A Review. Int. J. Dent. 2015. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Johansson, P.; Jimbo, R.; Kjellin, P.; Currie, F.; Chrcanovic, B.R.; Wennerberg, A. Biomechanical evaluation and surface characterization of a nano-modified surface on PEEK implants: A study in the rabbit tibia. Int. J. Nanomed. 2014, 9, 3903. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Waser-Althaus, J.; Salamon, A.; Waser, M.; Padeste, C.; Kreutzer, M.; Pieles, U.; Müller, B.; Peters, K. Differentiation of human mesenchymal stem cells on plasma-treated polyetheretherketone. J. Mater. Sci. Mater. Med. 2014, 25, 515–525. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Randolph, S.; Fowlkes, J.; Rack, P. Focused, nanoscale electron-beam-induced deposition and etching. Crit. Rev. Solid State Mater. Sci. 2006, 31, 55–89. [Google Scholar] [CrossRef] [Scilit]
- Mantese, J.V.; Brown, I.G.; Cheung, N.W.; Collins, G.A. Plasma-immersion ion implantation. MRS Bull. 1996, 21, 52–56. [Google Scholar] [CrossRef] [Scilit]
- Ha, S.; Mayer, J.; Koch, B.; Wintermantel, E. Plasma-sprayed hydroxylapatite coating on carbon fibre reinforced thermoplastic composite materials. J. Mater. Sci. Mater. Med. 1994, 5, 481–484. [Google Scholar] [CrossRef] [Scilit]
- Han, C.; Lee, E.; Kim, H.; Koh, Y.; Kim, K.N. The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties. Biomaterials 2010, 31, 3465–3470. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wen, J.; Lu, T.; Wang, X.; Xu, L.; Wu, Q.; Pan, H.; Wang, D.; Liu, X.; Jiang, X. In vitro an in vivo evaluation of silicate-coated polyetheretherketone fabricated by electron beam evaporation. ACS Appl. Mater. Interfaces 2016, 8, 13197–13206. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lu, T.; Liu, X.; Qian, S.; Cao, H.; Qiao, Y.; Mei, Y.; Chu, P.K.; Ding, C. Multilevel surface engineering of nanostructured TiO2 on carbonfiber-reinforced polyetheretherketone. Biomaterials 2014, 35, 5731–5740. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lu, T.; Qian, S.; Meng, F.; Ning, C.; Liu, X. Enhanced osteogenic activity of poly ether ether ketone using calcium plasma immersion ion implantation. Colloids Surf. B Biointerfaces 2016, 142, 192–198. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Chen, M.; Ouyang, L.; Lu, T.; Wang, H.; Meng, F.; Yang, Y.; Ning, C.; Ma, J.; Liu, X. Enhanced bioactivity and bacteriostatis of surface fluorinated polyetheretherketone. ACS Appl. Mater. Interfaces 2017, 9, 16824–16833. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Zhao, Y.; Wong, H.M.; Wang, W.; Li, P.; Xu, Z.; Chong, E.Y.W.; Yan, C.H.; Yeung, K.W.K.; Chu, P.K. Cytocompatibility, osseointegration, and bioactivity of three-dimensional porous and nanostructured network on polyetheretherketone. Biomaterials 2013, 34, 9264–9277. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Xu, A.; Liu, X.; Gao, X.; Deng, F.; Deng, Y.; Wei, S. Enhancement of osteogenesis on micro/nano-topographical carbon fiber-reinforced polyetheretherketone-nanohydroxyapatite biocomposite. Mater. Sci. Eng. C 2015, 48, 592–598. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Yee, R.S.L.; Zhang, K.; Ladewig, B.P. The effects of sulfonated poly(ether ether ketone) ion exchange preparation conditions on membrane properties. Membranes 2013, 3, 182–195. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Henneuse-Boxusa, C.; Boxusa, T.; Dulière, E.; Pringallea, C.; Tesolina, L.; Adriaensenb, Y.; Marchand-Brynaert, J. Surface amination of PEEK film by selective wet-chemistry. Polymer 1998, 39, 5359–5369. [Google Scholar] [CrossRef] [Scilit]
- Conceição, T.F.; Bertolino, J.R.; Barra, G.M.O.; Pires, A.T.N. Poly (ether ether ketone) derivatives: Synthetic route and characterization of nitrated and sulfonated polymers. Mater. Sci. Eng. C 2009, 29, 575–582. [Google Scholar] [CrossRef] [Scilit]
- Qahtani, M.S.A.A.; Wu, Y.; Spintzyk, S.; Krieg, P.; Killinger, A.; Schweizer, E.; Stephan, I.; Scheideler, L.; Geis-Gerstorfer, J.; Rupp, F. UV-A and UV-C light induced hydrophilization of dental implants. Dent. Mater. 2015, 31, e157–e167. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Poulsson, A.H.; Eglin, D.; Zeiter, S.; Camenisch, K.; Sprecher, C.; Agarwal, Y.; Nehrbass, D.; Willson, J.; Richards, R.G. Osseointegration of machined, injection moulded and oxygen plasma modified PEEK implants in a sheep model. Biomaterials 2014, 35, 3717–3728. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Schwitalla, A.; Müller, W.D. PEEK Dental Implants: A Review of the Literature. J. Oral Implantol. 2013, 39, 743–749. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Huang, R.; Shao, P.; Burns, C.; Feng, X. Sulfonation of poly(ether ether ketone) (PEEK): Kinetic study and characterization. J. Appl. Polym. Sci. 2001, 82, 2651–2660. [Google Scholar] [CrossRef] [Scilit]
- Nieminen, T.; Kallela, I.; Wuolijoki, E.; Kainulainen, H.; Hiidenheimo, I.; Rantala, I. Amorphous and crystalline polyetheretherketone: Mechanical properties and tissue reactions during a 3-year follow-up. J. Biomed. Mater. Res. Part A 2008, 84, 377–383. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Wenz, L.; Merritt, K.; Brown, S.; Moet, A.; Steffee, A. In vitro biocompatibility of polyetheretherketone and polysulfone composites. J. Biomed. Mater. Res. 1990, 24, 207–215. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rupp, F.; Gittens, R.A.; Scheideler, L.; Marmur, A.; Boyan, B.D.; Schwartz, Z.; Geis-Gerstorfer, J. A review on the wettability of dental implant surfaces I: Theoretical and experimental aspects. Acta Biomater. 2014, 10, 2894–2906. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Gittens, R.A.; Scheideler, L.; Rupp, F.; Hyzy, S.I.; Geis-Gerstorfer, J.; Schwartz, Z.; Boyan, B.D. A review on the wettability of dental implant surfaces II: Biological and clinical aspects. Acta Biomater. 2014, 10, 2907–2918. [Google Scholar] [CrossRef] [Scilit] [PubMed]

| Material | Elastic Modulus (GPa) | References |
|---|---|---|
| Titanium | 110 | Lee, 2012 [4] |
| Cobalt-Chromium | 180–210 | Wiesli, 2015 [28] |
| Zirconia | 210 | Lee, 2012 [4] |
| Porcelain | 68.9 | Lewinstein, 1995 [29] |
| PMMA | 3–5 | Vallittu, 1998; Zafar, 2014 [30,31] |
| PEEK | 3–4 | Sandler, 2002 [24] |
| CFR-PEEK | 18 | Sandler, 2002 [24] |
| Continuous CFR-PEEK (Endolign®) | 150 | Schwitalla, 2015 [25] |
| GFR-PEEK | 12 | Lee, 2012 [4] |
| Cortical bone | 14 | Martin, 1989; Rho, 1993 [32,33] |
| Cancellous bone | 1.34 | Borchers and Reichart, 1983 [34] |
| Enamel | 40–83 | Staines, 1981; Rees, 1993; Cavalli, 2004 [35,36,37] |
| Dentin | 15–30 | Rees, 1993; Chun, 2014 [36,38] |
| Surface Modifications | Procedures | Material | References |
|---|---|---|---|
| Coating | Plasma spraying | Hydroxyapatite (HA), titanium (Ti) | Rust-Dawicki, 1995; Suska, 2014; Ha, 1994 [27,45,53] |
| Spin coating | Nanosized HA crystals containing surfactans, organic solvent, an aquous solution of Ca(NO3)2 and H3PO4 | Barkarmo, 2012; Johansson, 2014 [43,49] | |
| Electron-beam evaporation (EBE) | Ti; Silicate | Han, 2010; Wen, 2016 [54,55] | |
| Plasma immersion ion implantation (PIII) | Titanium dioxide (TiO2); calcium (Ca); water (H2O); Argon (Ar) | Wang, 2014; Lu, 2014; Lu, 2016; Chen, 2017 [47,56,57,58] | |
| Surface topographical modifications | Acid etching | Sulfuric acid | Zhao, 2013 [59] |
| Sandblasting | TiO2, alumina (Al2O3) | Suska, 2014; Xu, 2015 [44,60] | |
| Chemical modifications | Sulphonation | Sulfonate groups (–SO3–) | Yee, 2013 [61] |
| Amination | Amine functions | Henneuse-Boxus, 1998 [62] | |
| Nitration | Nitrate functions | Conceição, 2009 [63] | |
| Incorporating with bioactive properties | Bioactive inorganic materials | Nano-TiO2 (n-TiO2); nano-fluorohydroxyapatite (n-FHA) | Wu, 2012; Wang, 2014 [45,47] |
| Improving hydrophylicity | UV irradiation | UV-A light, UV-C light | Qahtani, 2015 [64] |
| Plasma gas treatment | Oxygen plasma | Waser-Althaus, 2014; Xu, 2015; Poulsson, 2014 [50,60,65] |
© 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Rahmitasari, F.; Ishida, Y.; Kurahashi, K.; Matsuda, T.; Watanabe, M.; Ichikawa, T. PEEK with Reinforced Materials and Modifications for Dental Implant Applications. Dent. J. 2017, 5, 35. https://doi.org/10.3390/dj5040035
Rahmitasari F, Ishida Y, Kurahashi K, Matsuda T, Watanabe M, Ichikawa T. PEEK with Reinforced Materials and Modifications for Dental Implant Applications. Dentistry Journal. 2017; 5(4):35. https://doi.org/10.3390/dj5040035
Chicago/Turabian StyleRahmitasari, Fitria, Yuichi Ishida, Kosuke Kurahashi, Takashi Matsuda, Megumi Watanabe, and Tetsuo Ichikawa. 2017. "PEEK with Reinforced Materials and Modifications for Dental Implant Applications" Dentistry Journal 5, no. 4: 35. https://doi.org/10.3390/dj5040035
APA StyleRahmitasari, F., Ishida, Y., Kurahashi, K., Matsuda, T., Watanabe, M., & Ichikawa, T. (2017). PEEK with Reinforced Materials and Modifications for Dental Implant Applications. Dentistry Journal, 5(4), 35. https://doi.org/10.3390/dj5040035