Next Article in Journal
An Improved Mutual Information Feature Selection Technique for Intrusion Detection Systems in the Internet of Medical Things
Next Article in Special Issue
A Novel Active Device for Shoulder Rotation Based on Force Control
Previous Article in Journal
Using HVS Dual-Pathway and Contrast Sensitivity to Blindly Assess Image Quality
Previous Article in Special Issue
Research on Surface Tracking and Constant Force Control of a Grinding Robot
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Robotic Intracellular Pressure Measurement Using Micropipette Electrode

1
Institute of Robotics and Automatic Information System, Tianjin Key Laboratory of Intelligent Robotics, Nankai University, Tianjin 300350, China
2
Institute of Intelligence Technology and Robotic Systems, Shenzhen Research Institute of Nankai University, Shenzhen 518083, China
3
Beijing Advanced Innovation Center for Intelligent Robots and Systems, Beijing Institute of Technology, Beijing 100081, China
*
Author to whom correspondence should be addressed.
Sensors 2023, 23(10), 4973; https://doi.org/10.3390/s23104973
Submission received: 15 April 2023 / Revised: 18 May 2023 / Accepted: 20 May 2023 / Published: 22 May 2023
(This article belongs to the Special Issue Sensors for Robots II)

Abstract

Intracellular pressure, a key physical parameter of the intracellular environment, has been found to regulate multiple cell physiological activities and impact cell micromanipulation results. The intracellular pressure may reveal the mechanism of these cells’ physiological activities or improve the micro-manipulation accuracy for cells. The involvement of specialized and expensive devices and the significant damage to cell viability that the current intracellular pressure measurement methods cause significantly limit their wide applications. This paper proposes a robotic intracellular pressure measurement method using a traditional micropipette electrode system setup. First, the measured resistance of the micropipette inside the culture medium is modeled to analyze its variation trend when the pressure inside the micropipette increases. Then, the concentration of KCl solution filled inside the micropipette electrode that is suitable for intracellular pressure measurement is determined according to the tested electrode resistance–pressure relationship; 1 mol/L KCl solution is our final choice. Further, the measurement resistance of the micropipette electrode inside the cell is modeled to measure the intracellular pressure through the difference in key pressure before and after the release of the intracellular pressure. Based on the above work, a robotic measurement procedure of the intracellular pressure is established based on a traditional micropipette electrode system. The experimental results on porcine oocytes demonstrate that the proposed method can operate on cells at an average speed of 20~40 cells/day with measurement efficiency comparable to the related work. The average repeated error of the relationship between the measured electrode resistance and the pressure inside the micropipette electrode is less than 5%, and no observable intracellular pressure leakage was found during the measurement process, both guaranteeing the measurement accuracy of intracellular pressure. The measured results of the porcine oocytes are in accordance with those reported in related work. Moreover, a 90% survival rate of operated oocytes was obtained after measurement, proving limited damage to cell viability. Our method does not rely on expensive instruments and is conducive to promotion in daily laboratories.
Keywords: intracellular pressure; electrode circuit model; micropipette electrode; micro-nano operation intracellular pressure; electrode circuit model; micropipette electrode; micro-nano operation

Share and Cite

MDPI and ACS Style

Li, M.; Qiu, J.; Li, R.; Liu, Y.; Du, Y.; Liu, Y.; Sun, M.; Zhao, X.; Zhao, Q. Robotic Intracellular Pressure Measurement Using Micropipette Electrode. Sensors 2023, 23, 4973. https://doi.org/10.3390/s23104973

AMA Style

Li M, Qiu J, Li R, Liu Y, Du Y, Liu Y, Sun M, Zhao X, Zhao Q. Robotic Intracellular Pressure Measurement Using Micropipette Electrode. Sensors. 2023; 23(10):4973. https://doi.org/10.3390/s23104973

Chicago/Turabian Style

Li, Minghui, Jinyu Qiu, Ruimin Li, Yuzhu Liu, Yue Du, Yaowei Liu, Mingzhu Sun, Xin Zhao, and Qili Zhao. 2023. "Robotic Intracellular Pressure Measurement Using Micropipette Electrode" Sensors 23, no. 10: 4973. https://doi.org/10.3390/s23104973

APA Style

Li, M., Qiu, J., Li, R., Liu, Y., Du, Y., Liu, Y., Sun, M., Zhao, X., & Zhao, Q. (2023). Robotic Intracellular Pressure Measurement Using Micropipette Electrode. Sensors, 23(10), 4973. https://doi.org/10.3390/s23104973

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop