Next Article in Journal
Is Osteoarthritis Always Associated with Low Bone Mineral Density in Elderly Patients?
Next Article in Special Issue
Synergistic Sequential Emission of Fractional 10.600 and 1540 nm Lasers for Skin Resurfacing: An Ex Vivo Histological Evaluation
Previous Article in Journal
Malassezia Folliculitis following Triple Therapy for Cystic Fibrosis
Previous Article in Special Issue
The Low-Fluence Q-Switched Nd:YAG Laser Treatment for Melasma: A Systematic Review
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Comparing Traditional and in Motion Nd:YAG Laser in Hair Removal: A Prospective Study

1
Department of Health Sciences, Magna Graecia University, 88100 Catanzaro, Italy
2
Department of Dermatology, Sapienza University, 00185 Rome, Italy
*
Author to whom correspondence should be addressed.
Medicina 2022, 58(9), 1205; https://doi.org/10.3390/medicina58091205
Submission received: 2 July 2022 / Revised: 19 August 2022 / Accepted: 31 August 2022 / Published: 2 September 2022
(This article belongs to the Special Issue Lasers, Lights and New Technologies in Medicine and Surgery)

Abstract

:
Background and Objectives: Hair removal is a common cosmetic problem interesting more and more patients nowadays. Various laser treatments are currently available. Alexandrite and Nd:YAG laser are the most effective procedures in lighter and darker skin phototypes, respectively. Materials and Methods: A total of 40 patients seeking hair removal in one or more body areas with skin phototypes 2–6 was recruited to perform this study. Patients were divided into two groups. One group was treated with the standard Nd:YAG hair removal procedure, while the other group was treated with a new “in motion” Nd:YAG technology. Results and hair removal rates were evaluated six months after the last treatment. Results: Out of 40 patients treated, all patients experienced hair reduction. No statistically significant difference in hair removal was noted between the two groups; however, a statistically significant reduction in pain during the procedure was observed in the group treated with the “in motion” technique. Conclusions: While traditional and “in motion” Nd:YAG techniques have similar result outcomes in hair removal, the “in motion” technology seems to guarantee a better safety profile compared with the traditional technique. A more extensive clinical study will be necessary to confirm our study’s results.

1. Introduction

The abundance of hair is a common cosmetic problem, and patients seeking hair removal are becoming more frequent in medical practice [1,2]. Laser and light sources represent the mainstay in managing this condition [3]. Among laser systems currently used in hair removal management, 755 nm alexandrite lasers are usually preferred for lighter phototypes, while Nd:YAG lasers are used for darker phototypes [4,5]. Nd:YAG laser emits in the infrared spectrum at 1064 nm. According to its emission modality, this device can be used to manage different dermatological conditions. When emitting in pulsed mode, these types of lasers are used in the removal of hyperpigmentations and tattoos [6,7,8,9]. In continuous mode, this laser is instead used to manage vascular lesions and hair removal [10,11]. The longer wavelength of the Nd:YAG allows for less epidermal melanin absorption. Patients can tolerate higher fluences with minimal adverse events such as epidermal burn or dyspigmentation. The long-pulse Nd:YAG laser did not demonstrate significant long-term adverse events at high fluences (50, 80, and 100 J/cm2) when treating skin phototypes up to four, with only a tiny percentage of patients treated at 100 J/cm2 developing nonscarring blisters. Greater fluence did not result in more significant hair reduction, with similar efficacy in hair reduction in the two treatment groups (27–29%) at a 3-month follow-up [12]. In this work, we compare a new “in motion” technology with the traditional Nd:YAG laser in managing hair removal.

2. Materials and Methods

Forty patients with phototypes 2–6 presenting for hair removal were consecutively enrolled at the Unit of Dermatology of Magna Graecia University (Catanzaro, Italy) and at private practice (Florence, Italy). Patients reporting hypersensitivity to light or reporting the use of sulfonamides, phenothiazines, and contraceptives, being pregnant, breastfeeding, or with malignant tumors were excluded from the study. All patients signed informed consent on the risk of the procedure. Patients were divided into two groups. The first group underwent traditional therapy for hair removal with Nd:YAG laser (MotusAY, DEKA M.E.L.A., Calenzano, Italy) (Fluence: 30–40 J/cm2 Pulse duration: 10–20 ms Spot: 10–15 mm). Six treatments were performed with an interval between sessions of 4–8 weeks according to body area treated (face, groin, legs, or trunk).
The second group was treated with the “in motion” Nd:YAG handpiece of the same system (MoveoHR, MotusAY, DEKA M.E.L.A., Calenzano, Italy) with the following parameters: fluences ranging from 3 to 8 J/cm2, dose ranging from 1.5 to 3.5 KJ, and frequency ranging from 3 to 5 Hz, according to the endpoint (the development of perifollicular erythema). For the “in motion” technique, the user continuously moved the handpiece in a slow linear/circular motion, creating an area of 10 × 10 cm and executing multiple back-and-forth passes. The interested areas were shaved 48 h before each treatment. Before every treatment session, the same physician (S.N.) evaluated all patients. Hair reduction rate (R%) was quantified utilizing the following formula: ((the hair quantity before the first laser treatment–the hair quantity after the current laser treatment)/the hair quantity before the first laser treatment) × 100. Response to both treatments was assessed six months after the last treatment session. Immediately after each laser session, the same physician evaluated side effects, using a five-point scale to evaluate erythema and the presence of first-, second-, or third-degree burns. A visual analogue scale from 0 to 10 at the end of each treatment was administered to the patients to evaluate pain. At the end of treatment, a visual analogue scale about treatment satisfaction (from 1 to 8) was administered to the subjects. Student’s t test for paired data was used to compare the results obtained between groups. Statistica14.0 (TIBCO Software, Palo Alto, CA, USA) software was used for data analysis (mean, standard deviations, and rate calculations) (Figure 1).

3. Results

The patients were divided into two groups, not differing in sex distribution, age, or phototype (p > 0.05). Both groups reported a hair reduction of almost 85% (82.2% ± 6.9% for group one and 79% ± 5.4 for group two), with no statistical difference (p = 0.16). Patients of both groups reported a high degree of satisfaction (5.95 ± 1.09 for group one and 6.15 ± 1 for group two) with no statistically significant difference (p > 0.05). Group one reported a higher level of erythema after treatment (2.15 ± 0.99 vs. 1.65 ± 0.67), but this difference was not statistically significant (p > 0.05). Group one reported a higher level of pain during the procedures (6.05 ± 1.39 vs. 3.55 ± 1.15). This result was statistically significant (p < 0.001). No severe side effects were reported; however, in the traditional Nd:YAG group; one patient experienced a first-degree burn. All patients’ characteristics are reported in Table 1.

4. Discussion

The effectiveness of hair removal with the long-pulsed 1064 Nd:YAG laser was described in the late 1990s when Nd:YAG was proposed, first in pulsed mode and then in continuous mode for hair removal [13,14,15]. Since then, many studies, including the current study, have confirmed this device’s efficacy and safety profile, reporting a mean hair reduction of up to 80%. Ismail reported that at the six-month follow-up after all the procedures, patients treated with long-pulsed Nd:YAG laser experienced a 79.4% decrease in hair count [16]. Other studies reported a decrease in hair count from 50 to 60%, but this variability may be associated with the researcher experience, as well as with a different treatment protocol [17,18]. Recently, short-pulsed Nd:YAG laser has been proposed for hair removal, with results that need further confirmation [19]. Our study confirmed good results in managing phototypes two and three, traditionally treated with other laser devices, showing overall good results. Pain was the patients’ most referred concern, but it was bearable during all the procedures when using the new “in motion” technology. Only one minor burn was reported, using the traditional technique, that spontaneously resolved without leaving any scar or dyspigmentation in a couple of weeks while applying an antibiotic cream. Containment of the side effects and the pain can be explained through the emission mode of the “in motion” technique. The technique, which uses a cooled handpiece, indeed, uses a minimal energy emission to reduce the pain sensation. The physician continuously moved the handpiece in a slow linear/circular motion inside an area of 100 square centimeters and executing multiple back-and-forth passes up to a defined follicular heat endpoint. By doing so, the areas are treated in a short length of time, the device is easier to use—as skin does not easily reach high temperatures associated with burns—and larger areas are treated more rapidly. This method allows a progressive increase of the target temperature, monitoring the cutaneous reactions, and being able to interrupt or modify the treatment at any time, thus minimizing the typical side effects of the traditional method, as already proposed for other typologies of lasers in hair removal [20].

5. Conclusions

Standard log pulsed Nd:YAG laser and Nd:YAG with Moveo emission have proven to be effective and safe technologies capable of achieving long-standing results in body hair removal in Fitzpatrick’s skin types 2–6. In our study, however, this new “in motion” technology, while being equally effective, has proven to be associated with less erythema, side effects, and only minor patient-perceived pain. Of course, further studies will be necessary to confirm our study results.

Author Contributions

Conceptualization, S.P.N. and L.B.; validation, G.C., E.Z. and S.B.; formal analysis, M.M.; data curation, M.S.; writing—original draft preparation, L.B.; writing—review and editing, S.P.N.; supervision, G.C. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki, and approved by the Institutional Review Board of Calabria Centro (00373/2019 date of approval 17 December 2019).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Data are available from the corresponding author upon reasonable request.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Thomas, M.M.; Houreld, N.N. The “in′s and outs” of laser hair removal: A mini review. J. Cosmet. Laser Ther. 2019, 21, 316–322. [Google Scholar] [CrossRef] [PubMed]
  2. Casey, A.S.; Goldberg, D. Guidelines for laser hair removal. J. Cosmet. Laser Ther. 2008, 10, 24–33. [Google Scholar] [CrossRef] [PubMed]
  3. Bennardo, L.; Del Duca, E.; Dattola, A.; Cannarozzo, G.; Nistico, S.P. Management of laser treatments during the coronavirus disease 2019 pandemic: The Italian experience. Clin. Dermatol. 2021, 39, 521–522. [Google Scholar] [CrossRef] [PubMed]
  4. Rao, K.; Sankar, T.K. Long-pulsed Nd:YAG laser-assisted hair removal in Fitzpatrick skin types IV–VI. Lasers Med. Sci. 2011, 26, 623–626. [Google Scholar] [CrossRef] [PubMed]
  5. Nistico, S.P.; Bennardo, L.; Del Duca, E.; Tamburi, F.; Rajabi-Estarabadi, A.; Nouri, K. Long-pulsed 755-nm alexandrite laser equipped with a sapphire handpiece: Unwanted hair removal in darker phototypes. Lasers Med. Sci. 2021, 36, 237–238. [Google Scholar] [CrossRef] [PubMed]
  6. Cannarozzo, G.; Nisticò, S.P.; Zappia, E.; Del Duca, E.; Provenzano, E.; Patruno, C.; Negosanti, F.; Sannino, M.; Bennardo, L. Q-Switched 1064/532 nm Laser with Nanosecond Pulse in Tattoo Treatment: A Double-Center Retrospective Study. Life 2021, 11, 699. [Google Scholar] [CrossRef] [PubMed]
  7. Silvestri, M.; Bennardo, L.; Zappia, E.; Tamburi, F.; Cameli, N.; Cannarozzo, G.; Nisticò, S.P. Q-Switched 1064/532 nm Laser with Picosecond Pulse to Treat Benign Hyperpigmentations: A Single-Center Retrospective Study. Appl. Sci. 2021, 11, 7478. [Google Scholar] [CrossRef]
  8. Bennardo, L.; Cannarozzo, G.; Tamburi, F.; Patruno, C.; Provenzano, E.; Nisticò, S.P. Picosecond Q-Switched 1064/532 nm Laser in Tattoo Removal: Our Single Center Experience. Appl. Sci. 2021, 11, 9712. [Google Scholar] [CrossRef]
  9. Cannarozzo, G.; Negosanti, F.; Sannino, M.; Santoli, M.; Bennardo, L.; Banzola, N.; Negosanti, L.; Nisticò, S.P. Q-switched Nd:YAG laser for cosmetic tattoo removal. Dermatol. Ther. 2019, 32, e13042. [Google Scholar] [CrossRef] [PubMed]
  10. Negosanti, F.; Silvestri, M.; Bennardo, L.; Durastante, C.; Duca, E.D.; Cannarozzo, G.; Nisticò, S.P. Nd:YAG laser in association with pulsed dye laser for the treatment of PHACES syndrome. Dermatol. Rep. 2021, 13, 8751. [Google Scholar] [CrossRef] [PubMed]
  11. Bennardo, L.; Fasano, G.; Tamburi, F.; Zappia, E.; Rizzuto, F.; Nisticò, S.P.; Cannarozzo, G. Sequential Use of CO2 Laser Prior to Nd:YAG and Dye Laser in the Management of Non-Facial Warts: A Retrospective Study. Medicina 2022, 58, 115. [Google Scholar] [CrossRef] [PubMed]
  12. Goldberg, D.J.; Silapunt, S. Hair removal using a long-pulsed nd:yag laser: Comparison at fluences of 50, 80, and 100 j/cm. Dermatol. Surg. 2001, 27, 434–436. [Google Scholar] [CrossRef] [PubMed]
  13. Littler, C.M. Hair removal using an Nd:YAG laser system. Dermatol. Clin. 1999, 17, 401–430. [Google Scholar] [CrossRef]
  14. Goldberg, D.J.; Littler, C.M.; Wheeland, R.G. Topical suspension-assisted Q-switched Nd:YAG laser hair removal. Dermatol. Surg. 1997, 23, 741–745. [Google Scholar] [CrossRef] [PubMed]
  15. Nanni, C.A.; Alster, T.S. Optimizing treatment parameters for hair removal using a topical carbon-based solution and 1064-nm Q-switched neodymium:YAG laser energy. Arch. Dermatol. 1997, 133, 1546–1549. [Google Scholar] [CrossRef] [PubMed]
  16. Ismail, S.A. Long-pulsed Nd:YAG laser vs. intense pulsed light for hair removal in dark skin: A randomized controlled trial. Br. J. Dermatol. 2012, 166, 317–321. [Google Scholar] [CrossRef] [PubMed]
  17. Lorenz, S.; Brunnberg, S.; Landthaler, M.; Hohenleutner, U. Hair removal with the long pulsed Nd:YAG laser: A prospective study with one year follow-up. Lasers Surg. Med. 2002, 30, 127–134. [Google Scholar] [CrossRef] [PubMed]
  18. Raff, K.; Landthaler, M.; Hohenleutner, U. Optimizing treatment parameters for hair removal using long-pulsed Nd:YAG-lasers. Lasers Med. Sci. 2004, 18, 219–222. [Google Scholar] [CrossRef] [PubMed]
  19. Jane, S.D.; Mysore, V. Effectiveness of short-pulse width Nd:YAG in laser hair reduction. J. Cosmet. Dermatol. 2018, 17, 1046–1052. [Google Scholar] [CrossRef] [PubMed]
  20. Bonan, P.; Troiano, M.; Verdelli, A. Safety and efficacy of single pass vs multipass emission with 755 alexandrite laser for all-skin-type hair removal: A pilot study. Dermatol. Ther. 2020, 33, e14001. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Patient 27 treated with the “in motion” technique before treatment (upper left picture) after two sessions (upper right picture), four sessions (lower left picture), and six sessions (lower right picture).
Figure 1. Patient 27 treated with the “in motion” technique before treatment (upper left picture) after two sessions (upper right picture), four sessions (lower left picture), and six sessions (lower right picture).
Medicina 58 01205 g001
Table 1. Patient characteristics.
Table 1. Patient characteristics.
Patient NumberPhototypeSexBody LocationAgeVAS ErythemaVAS Treatment SatisfactionHair Reduction Rate Pain VAS (Mean)
Group 1 standard Nd:YAG
13FLegs2136866
25MGroins3217877
32FLegs2635807
45FLegs414 (burn)5746
56FFace2925968
65MLegs1926856
75FTrunk3116777
83FGroins2237736
96MLegs2828936
103FFace4844798
115FTrunk1915807
124FLegs3115764
134FLegs3716723
146MFace3425905
154FGroins4736876
166FTrunk1827794
175FLegs2916827
183FGroins2127745
194FLegs3937888
203FTrunk4526865
Group 2 “in motion” Nd:YAG
213FLegs2226773
225FGroins1815704
232FFace4516823
245FLegs4816832
256MLegs2626786
265FGroins3927863
275MTrunk2923894
283FLegs2117833
296FFace2637742
303FGroins4816716
315FLegs3927774
324MLegs3626705
334FTrunk2927793
346FFace2237744
354FLegs1924864
366FGroins2317772
375FTrunk2517793
383MGroins3417844
394FLegs4126803
403FLegs3216813
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Nistico, S.P.; Bennardo, L.; Bennardo, S.; Marigliano, M.; Zappia, E.; Silvestri, M.; Cannarozzo, G. Comparing Traditional and in Motion Nd:YAG Laser in Hair Removal: A Prospective Study. Medicina 2022, 58, 1205. https://doi.org/10.3390/medicina58091205

AMA Style

Nistico SP, Bennardo L, Bennardo S, Marigliano M, Zappia E, Silvestri M, Cannarozzo G. Comparing Traditional and in Motion Nd:YAG Laser in Hair Removal: A Prospective Study. Medicina. 2022; 58(9):1205. https://doi.org/10.3390/medicina58091205

Chicago/Turabian Style

Nistico, Steven Paul, Luigi Bennardo, Stefano Bennardo, Miriam Marigliano, Elena Zappia, Martina Silvestri, and Giovanni Cannarozzo. 2022. "Comparing Traditional and in Motion Nd:YAG Laser in Hair Removal: A Prospective Study" Medicina 58, no. 9: 1205. https://doi.org/10.3390/medicina58091205

Article Metrics

Back to TopTop