Real-Time Sensorless Robust Velocity Controller Applied to a DC-Motor for Emulating a Wind Turbine

by
Onofre A. Morfin
1,
Riemann Ruiz-Cruz
2,*,
Jesus I. Hernández
1,
Carlos E. Castañeda
3,
Reymundo Ramírez-Betancour
4 and
Fredy A. Valenzuela-Murillo
4
1
Departamento de Eléctrica y Computación, Instituto de Ingeniería y Tecnología, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez 32310, Mexico
2
Laboratorio de Investigación en Diseño Optimo, Dispositivos y Materiales Avanzados (OPTIMA), Departamento de Matemáticas y Física, ITESO, Tlaquepaque 45604, Mexico
3
Departamento de Ciencias Exactas y Tecnología, Centro Universitario de los Lagos de la Universidad de Guadalajara, Lagos de Moreno 47460, Mexico
4
División Académica de Ingeniería y Arquitectura, Universidad Juárez Autónoma de Tabasco, Cunduacán 86040, Mexico
*
Author to whom correspondence should be addressed.
Energies 2021, 14(4), 868; https://doi.org/10.3390/en14040868
Submission received: 30 October 2020 / Revised: 9 January 2021 / Accepted: 28 January 2021 / Published: 7 February 2021

Abstract

:
The wind power systems of variable velocity using a doubly-fed induction generator dominate large-scale electrical generation within renewable energy sources. The usual control goal of the wind systems consists of maximizing the wind energy capture and streamlining the energy conversion process. In addition, these systems are an intermittent energy source due to the variation of the wind velocity. Consequently, the control system designed to establish a reliable operation of the wind system represents the main challenge. Therefore, emulating the operation of the wind turbine by means of an electric motor is a common strategy so that the controller design is focused on the induction generator and its connection to the utility grid. Thus, we propose to emulate the dynamical operation of a wind turbine through a separately excited DC motor driving by a sensor-less velocity controller. This controller is synthesized based on the state-feedback linearization technique combined with the super-twisting algorithm to set a robust closed-loop system in the presence of external disturbances. A robust velocity observer is designed to estimate the rotor velocity based on the armature current measuring. Furthermore, a robust differentiator is designed for estimating the time derivative of the velocity error variable, achieving a reduction in the computational calculus. Experimental tests were carried using a separately excited DC motor coupled with a dynamometer to validate the proposed wind turbine emulator.

1. Introduction

Among the different systems that use renewable energy, wind power generation is highlighted, where wind as the primary energy source is free and renewable. Wind power systems are characterized by being a variable energy source due to the wind speed depending on weather conditions. In addition, wind power systems operate under conditions of variable velocity, maximum extraction of wind energy, minimum losses in the energy conversion process, and comply with the connection standards within a utility grid. Therefore, these operating conditions represent a technological challenge in the design of the control system applied to wind power systems. It is common practice to emulate in a laboratory the wind turbine operation by means of an electric motor that tracks the output velocity from a virtual wind system and thus replaces the turbine. Consequently, using a wind turbine emulator, the infrastructure related to the wind turbine is avoided, such as the wind tunnel and the turbine, among other components needed for the operation of a real wind system.
In this sense, some works regarding wind turbine emulators based on electrical machines have been reported in the specialized literature. In [1], a four-quadrant dynamometer is used, while the permanent magnet synchronous motor (PMSM) is applied in [2,3,4,5] and the induction motor is used in [6,7,8]. However, most emulators reported are based on the DC motor due to the flexibility in its operation and simplicity in the design and implementation of its control systems. In [9], a simple closed loop control based on the hysteresis band is presented. Fuzzy logic control techniques and first-order sliding modes are used in [10,11], respectively. Additionally, a classical PI control has been widely used to regulate the DC motor velocity [12,13,14,15,16,17]. This controller has some disadvantages such as high overshoot, sensitivity to the parameter variation, and maintaining a steady-state error. All previous reported controllers use a velocity sensor to solve the problem of velocity tracking, which raises the cost of construction and increases friction losses. In addition, velocity sensors reduce reliability due to the growth in the number of mechanical components.
The main motivation in this work is to emulate the operation of a small-scale wind turbine by means of a DC motor that is driven by a robust velocity controller, does not use a mechanical speed sensor, and does not depend on any motor parameter. For the implementation and validation of the wind turbine emulator, the DC motor is coupled with a dynamometer that configures the electromagnetic torque of an electric generator which is contained in a virtual wind system. Our proposal lays the foundations for a future work to emulate a whole wind system connected to the electricity grid through a DC motor directly coupled to an electric generator, which is controlled to maximize the capture of energy from the wind and connect the power generated to the utility grid. Therefore, the emulation of the wind system avoids including the infrastructure related to the wind turbine, the wind tunnel, and the accessories needed for the operation of a real wind system on a small scale.
The main contribution of this research consists in providing a methodology for the design and physical implementation of a wind turbine emulator through a DC motor coupled with a dynamometer that sets the generator torque from a virtual wind system. When the DC motor tracks the velocity from virtual wind system, it mimics the operation of the wind turbine. The tracking problem is solving through a sensorless robust velocity controller which is synthesized applying the state-feedback linearization technique combined with the super-twisting algorithm to configure a robust closed-loop system in the presence of load torque changes. A robust velocity observer to estimate the motor velocity is designed based on the armature current measuring, so that the velocity controller only uses an armature current sensor to perform its operation.
This article is organized as follows. Section 2 describes the mechanical model that defines the virtual wind system. Section 3 presents the design of a robust observer that estimates the motor velocity and that gives the sensorless characteristic to the velocity control system. Section 4 shows the design process of the velocity controller for tracking the output velocity of a virtual wind system. Section 5 shows the experimental results that validate the good performance of the emulator. Finally, the conclusions of the work are drawn in Section 6.

2. Wind System Model

The wind energy is transformed into rotatory mechanical energy when the kinetic energy of the wind collides with the blades of the turbine commonly composed of three blades. The turbine is mechanically coupled to an electric generator through a gearbox whose purpose is to convet the low velocity of the turbine to the high velocity of the generator. The mechanical power developed by the wind turbine is defined by the following equation [18]:
P m = 1 2 ρ a π R t b 2 C p v w 3 ,
where ρ a is the wind density of the place; π R t b 2 is the sweep area of the turbine; C p is the power coefficient that defines the wind turbine efficiency, and this term is the only one that can vary influenced by a control action; and v w is the wind speed raised to the cube. It is important to highlight that the amplification of power due to the increase in wind speed makes the wind power systems very attractive. The turbine torque is calculated by dividing the mechanical power (1) by the angular velocity of the turbine, resulting in:
T t b = K a R t b C p λ v w 2 .
The power coefficient C p depends on the constructive characteristics of the turbine and it varies according to the tip-speed ratio λ , which is defined as the ratio of the tangential speed in the turbine tip by the wind speed, as follows:
λ = ω t b R t b v w ,
where ω t b represents the angular velocity of the turbine. The power coefficient curve can be approximated with the following nonlinear function [19]:
C p ( λ , β ) = c 1 c 2 λ i c 3 β c 4 e c 5 λ i + c 6 λ ,
with
1 λ i = 1 λ 0.08 β 0.035 β 3 + 1 ,
where β is the pitch angle of the turbine blades and the values of constants c 1 c 6 are related to the unique design of a wind turbine and are generally obtained empirically in laboratory tests. In this proposal, the stall wind turbine parameters β = 0 , c 1 = 0.5176 , c 2 = 116 , c 3 = 0.4 , c 4 = 5 , c 5 = 21 , and c 6 = 0.0068 were taken from Voltolini et al. [19]. The power coefficient curve is depicted in Figure 1, where the maximum power coefficient C p is 0.46 , which is related to the desired tip-speed ratio λ d e s of 8.2 . The λ d e s desired is a constant value, which is obtained when Equation (4) is maximum C p ( λ , β ) λ = 0 .
On the other hand, the mechanical oscillation equation of the wind system, where the torsional forces of all components coupled in the shaft train are always in balance, can be approximate by the following expression:
d ω m d t = 1 J t T t b n g b T g B t ω m ,
where the mechanical parameters are the total inertial moment J t and the total frictional coefficient B t . Both parameters are referred to the high velocity side of the generator with J t = J t b n g b 2 + J g and B t = B t b n g b 2 + B g where J t b and B t b are the inertial moment and frictional coefficient of the wind turbine, respectively; J g and B g are the inertial moment and frictional coefficient of the electric generator; ω m is the generator angular velocity; T t b is the mechanical turbine torque; n g b is the gearbox ratio that couples the wind turbine low velocity with the generator high velocity; and T g is the generator torque which can be controlled by tracking of a reference torque.
The common control goal of a wind system consists of maximizing the wind energy capture, which is achieved by maintaining the coefficient power of the turbine power in its maximum value (1). Then, considering that the desired tip-speed ratio ( λ d e s ) is reached when the coefficient power is maximized, from Equation (3) the following relation is fulfilled:
ω d e s = λ d e s n g b R t b v w .
Defining the velocity tracking error as ε ω = ω d e s ω m and using (5), the evaluation of the tracking error derivative is calculated as:
ε ˙ ω = λ d e s n g b R t b v ˙ w 1 J t T t b n g b T g B t ω m .
The asymptotic convergence of the velocity tracking error can be established as ε ˙ ω = K 1 ε ω , with K 1 > 0 [20]. Then,
ε ˙ ω = λ d e s n g b R t b v ˙ w 1 J t T t b n g b T g B t ω m = K 1 ε ω ,
where the electric torque reference for the generator can be calculated by solving T g in (8) as:
T r e f = T t b n g b B t ω m J t λ d e s n g b R t b v ˙ w + K 1 ε ω .
From (9), it is easy to see that the electric torque reference ( T r e f ) used for the generator’s torque controller is a function of the time derivative of wind velocity ( v w ), the turbine torque ( T t b ), and the generator velocity ( ω m ). On the other hand, when the generator velocity is controlled, the desired velocity (6) is defined as the velocity reference. Therefore, in this work, a robust observer is proposed to estimate the mechanical velocity of the generator, thus avoiding the use of a velocity sensor in the emulation of the turbine operation.

3. DC Motor Velocity Observer Design

The DC motor is a very versatile electric machine to set different operation characteristics. Using the DC motor as the prime motor, a wide range of velocities can be established simply compared to other electric motors. Then, by modulating the voltage supply to armature winding, the DC motor can work from standstill to nominal velocity and by weakening the field winding velocities can be set above nominal. However, the use of a velocity sensor in closed loop velocity controllers requires wires and signal conditioning, consequently increasing the maintenance requirements. Thus, it is proposed to apply a robust observer to estimate the rotor velocity through the measuring of the armature current [21]. The observer design is based on the DC motor model, which is a separately excited DC motor with constant magnetizing whose model is [22]:
d d t ω m = 1 J m B m ω m + K m i a T L d d t i a = 1 L a K f ω m + R a i a u a ,
where the armature current i a and rotor velocity ω m are the state variables; the mechanical input T L is the load torque; u a is the control input that corresponds to the voltage supplied to armature winding; R a and L a are the resistance and inductance of the armature winding, respectively; B m and J m are the frictional coefficient and inertial moment of the DC motor and the mechanical load together, respectively; and K m and K f are the machine constants that include the constant field current, both having the same value but different measure units. The proposal of the robust rotor velocity observer has the following form [21]:
d d t ω ^ m = 1 J m B m ω ^ m + K m i ^ a T L l 1 v d d t i ^ a = 1 L a K f ω ^ m + R a i ^ a u a + v ,
where ω ^ m and i ^ a are the observed velocity and observed armature current, respectively; l 1 is a constant; and v = M sign i ^ a i a is a discontinuous input with the observation error of the armature current as argument [23]. The observation error system is obtained from (10) and (11) where the observation error variables are defined as ω ˜ m = ω ^ m ω m and i ˜ a = i ^ a i a . Then, this system is:
d d t ω ˜ m = 1 J m B m ω ˜ m + K m i ˜ a l 1 v d d t i ˜ a = 1 L a K f w ˜ m + R a i ˜ a + v .
Applying the equivalent control method where v e q forces the current observation error to zero i ^ a i a = 0 in the second equation of (12) results v e q = K f L a ω ˜ m . Then, substituting v e q in the first equation of (12), the following homogeneous system is obtained:
d d t ω ˜ m = B m J m + l 1 K m L a ω ˜ m ,
where the observation velocity error convergence is established by the following expression:
p = B m J m + l 1 K m L a ,
and the constant l 1 that defines the value of the pole of (11) is calculated by:
l 1 = L a K m p B m J m .
l 1 defines the convergence rate of velocity observation and its value is selected to set a faster dynamic than the mechanical equation dynamic of DC motor (10).

4. Sensorless DC-Motor Velocity Controller

This paper proposes a state-feedback linearization technique for transforming the DC motor model (10) to the controllable canonical form with error variables. Thus, the velocity error variable is defined as:
ε 1 = ω r e f ω m ,
where ω r e f is the velocity reference defined in (6) as desired velocity and ω m is the rotor velocity. From the DC motor model (10), the dynamics of the velocity error variable (16) takes the form:
ε ˙ 1 = ω ˙ r e f + B m J m ω m K f J m i a + 1 J m T L .
A second new variable ε 2 is defined as the first-order time derivative of ε 1 :
ε 2 = ε ˙ 1 .
The dynamics of the second variable (18), involving the DC motor model (10), takes the following form:
ε ˙ 2 = d 2 ω r e f d t 2 + B m J m d ω m d t K f J m d i a d t + 1 J m d T L d t ,
and solving for the armature current i a from (17) and involving (16) yields:
i a = J m K f ε ˙ 1 B m J m ε 1 + ω ˙ r e f + B m J m ω r e f + 1 J m T L .
Using the variable (18) and substituting the DC motor model (10), the velocity error variable (16), and the armature current (20) into Equation (19), the controllable canonical form is obtained as follows [24]:
ε ˙ 1 = ε 2 ε ˙ 2 = K f 2 J m L a + 1 τ m τ a ε 1 1 τ m + 1 τ a ε 2 + ω ¨ r e f + 1 τ m + 1 τ a ω ˙ r e f + K f 2 J m L a + 1 τ m τ a ω r e f + 1 J m T ˙ L + 1 J m B m J m 2 T L K f J m L a u a
where τ a = L a R a and τ m = J m B m are the time constants of the armature winding circuit and the mechanical state equation, respectively. To propose a robust control, the following variable is used:
s = C 1 ε 1 + ε 2 ,
which defines the new system
s ˙ = C 1 ε 2 + ε ˙ 2 .
Substituting the system (21) into (23) yields:
s ˙ = ρ K v u a ,
where
ρ = C 1 ε 2 K f 2 J m L a + 1 τ m τ a ε 1 1 τ m + 1 τ a ε 2 + ω ¨ r e f + 1 τ m + 1 τ a ω ˙ r e f + K f 2 J m L a + 1 τ m τ a ω r e f + 1 J m T ˙ L + 1 J m B m J m 2 T L
and
K v = K f i f J m L a .
The system (24) is the first order, thus a control law of the first order can be applied to configure a robust velocity controller. The control law used is the super-twisting algorithm, which is commonly applied in first-order systems and is characterized by providing finite time convergence toward the origin for the sliding variable and its first-order time derivative simultaneously. In addition, it generates a quasi-continuous control signal and reduces the chattering effect [25]. Then, applying the super-twisting algorithm to the closed-loop system (24), it takes the following form:
s ˙ = K v λ | s | 1 / 2 sign ( s ) + v + ρ v ˙ = α sign ( s ) ,
where λ > 0 and α > 0 are the control gains and the discontinuous function commutes a high frequency for giving robustness to cancel the disturbance ρ of the system (27) and steer the sliding variable and its time derivative toward the origin in finite time, simultaneously. Thus, the error velocity variable (22) vanishes to the origin in asymptotic form and consequently the velocity control goal is achieved:
ε 1 ˙ = C 1 ε 1 .
where C 1 is the new pole that defines the vanishing rate of the velocity error. The control gains λ and α are held to following restrictions:
λ < 1 K v δ ,
and
α > 1 4 K v λ 2 δ K v λ K v λ 2 δ ,
where the disturbance norm is defined as ρ = δ s 1 / 2 , for δ > 0 . The inequalities (29) and (30) are defined in [24] following the procedure established by Moreno and Osorio [26].
It is important to remark the effective performance of the proposed sensorless velocity controller, as it is non-sensitive to the load torque changes, so that the time derivative of the velocity error ε 2 is estimated through a robust differentiator and, consequently, the load torque is not involved in the surface variable s. The application of the robust differentiator [24] consists of filtering the input function f 0 ( t ) and estimating its first-order time derivative f ˙ 0 ( t ) , with the quality of the time derivative function being robust in the presence of noise. The robust differentiator design includes the following auxiliary system:
z ˙ = v ,
being v an input control that applies the super-twisting algorithm of sliding modes whose argument is defined by x = ε 1 z , where ε 1 is the input function. Then, the input control forces x = 0 and x ˙ = 0 and consequently z = ε 1 and ε ˙ 1 = v with the restriction ε 1 ¨ < L , where L is the Lipschitz constant. Applying the differentiator defined in (31), the estimation of the time derivative of the velocity error variable takes the following form:
ε 2 = ε ˙ 1 = λ 1 | ε 1 z | 1 / 2 sign ( ε 1 z ) + w w ˙ = λ 2 sign ( ε 1 z ) ,
where λ 1 and λ 2 are the gains that affect the differentiator performance; thus, to guaranty the differentiator convergence, the following restrictions must be held: λ 2 > L and 2 ( λ 2 + L ) 2 λ 1 2 ( λ 2 L ) < 1 [27]. Nevertheless, the differentiator gains can be tuned in experimental form monitoring directly the variables ε 1 and its time derivative ε 2 to solve a tracking problem using an oscillator as reference function.
Once the synthesis of the sensorless DC motor velocity controller is performed, including the velocity observer and the robust differentiator, then the control goal to emulate the turbine operation is achieved. This allows emulating a whole wind system by coupling the DC motor with a doubly-fed induction generator, without the need to use a velocity sensor. Hence, further research can be focused on robust techniques in the controller design of the induction generator to maximize the wind energy capture and in the controller design of the power interface to connect the generated energy with the utility grid. Note that the velocity controller design applied to the DC motor is the simplest compared to other electric motors because of the simplicity of its mathematical model (10).

5. Experimental Results

The experimental validation of the wind turbine emulator was performed in a laboratory and the emulator is composed of the following:
  • A separately excited DC-motor (8211-02 LabVolt) coupled with a dynamometer (8960-12 Labvolt) via a belt; the dynamometer sets its load torque from the generator data sent by a virtual wind system through an input/output interface
  • A virtual wind system having one input, the wind speed, and two outputs, the rotor velocity reference and the turbine torque
  • A sensorless DC motor velocity controller to track the output velocity of the virtual wind system; the velocity controller includes a robust sliding mode observer to estimate the rotor velocity and a robust differentiator to estimate the first-order time derivative of the velocity tracking error
  • The software and hardware necessary to perform the experiment, using the dSPACE 1103 kit, a power supply, AC-DC mono-phase converter, and only one sensor, to measure the armature current
The dSPACE 1103 kit is composed of a control target, an input–output interface, and visualization software, among other components. The scheme of the wind turbine emulator is shown in Figure 2, while the workbench where the experiment was performed is shown in Figure 3. The wind turbine parameters are presented in Table 1 and the nameplate data and DC motor parameters are presented in Table 2.
Before presenting the emulator performance, a robustness test of the proposed sensorless velocity controller was setup. The source program was codified using Simulink/Matlab with a sample time of 100 μs. The motor velocity was controlled from standstill tracking a ramp until 1500 r.p.m., and then sudden changes of the velocity reference in step form are presented together with sudden changes of the load torque by means of two pulses, as shown in Figure 4. The ramp reference increases from the standstill with a slope of 375.1 r.p.m./s to 1500 r.p.m. with a steady state error of 0.2%, and, subsequently, in Second 11, three steps of the velocity reference with a magnitude of 100 r.p.m. during 4 s are setup. When the velocity reference changes from 1700 to 1800 r.p.m. at Second 19, the motor velocity response has a settling time of 0.76 s, an overshoot of 9%, and steady state error of 0.8%. The external disturbances appear in Second 9, with two pulses of the load torque that vary from 0 to 0.75 N.m (corresponding to a load factor of 75%) during a period of 8 s. It is important to remark that the sensorless velocity controller is robust when the load torque changes are presented due to the action of the super-twisting control law. The performance of the controller is shown in Figure 5. The control input has average chattering of 8 V. When the velocity reference changes suddenly, a sudden change of the velocity error variable to 1.2 rad/s is presented, as shown in Figure 5a.
The main test corresponds to the wind turbine emulator performance, which is shown in Figure 6. It is observed that the DC motor velocity ω m tracks closely the velocity reference ω r e f set by the virtual wind system, and, thus, the control goal is achieved, i.e., the emulator behaves as a wind turbine. The tracking of the oscillating velocity reference is accurate, as observed in Figure 6. The velocity reference oscillates from 1186 to 2221 r.p.m. due to the wind speed, oscillating approximately from 3.8 to 7.2 m/s, with a time period of 8.3 s, as shown in Figure 7a, being the wind speed the input of the virtual wind system. Besides, the wind velocity oscillation causes oscillation of both the wind turbine torque T t b (from 0.23 to 0.83 N.m) and the generator torque T g (from 0.01 to 0.72 N.m); the time period of oscillation of these two signals is 8.3 s, as shown in Figure 7b. The generator torque T g is made to match with the reference torque defined in Equation (9). This mode of operation is achieved when the torque of the generator is controlled, and, consequently, the captured wind energy is maximized. Therefore, the power coefficient C p maintains a value of 0.44 near its maximum value, as shown in Figure 8a, and the corresponding desired value of tip-speed ratio λ is maintained at 8.1 , as depicted in Figure 8b.
Figure 9a shows that the velocity error variable stays close to zero at high frequency, while the control input, as the voltage supply to armature winding of the DC motor, varies from 87.5 to 177 V with an average chattering of 2 V, as shown in Figure 9b. The sensorless velocity controller applies the super-twisting control law of sliding modes (27), which was tuned with the gains λ = 0.075 and α = 47 , according to restrictions setting in (29) and (30). The velocity observer performance is shown in Figure 10, where the observed current i ^ a is almost the same as the measured current i a , as shown in Figure 10a. This guaranties a good estimation of the velocity ω ^ m via the robust observer, which is compared with the measured velocity ω m for validation purposes (see Figure 10b). The robust velocity observer applies a discontinuous input of first-order sliding modes to adjust the observation variables, which was tuned with gains l 1 = 14.5 to vanish the velocity estimation error to the origin, using the discontinuous input v = 4 sign ( i ^ a i a ) to force the current estimation error to the origin in finite time (12).

6. Conclusions

This article proposes a design methodology and its implementation in real-time of an emulator to the operation of a wind turbine. The proposal consists of mimicking the turbine operation through a separately excited DC motor driving by a sensorless velocity controller that tracks the output velocity of a virtual wind system. The velocity controller is distinguished by being sensorless because the rotor velocity is estimated through a robust observer and uses only the armature current measurement. In the design of the sliding variable, a robust differentiator is applied and tuned to estimate the first-order time derivative of the velocity error variable, thus avoiding its calculation that involves the load torque, which is commonly estimated via an asymptotic observer. A robust observer is proposed to estimate the rotor velocity being adjusted through a discontinuous input having as argument the armature current observation error. On the other hand, the super-twisting control law is applied to force the movement of the sliding variable and its first derivative simultaneously towards zero, and, with this, an asymptotic movement of the velocity tracking error towards zero is achieved. Experimental results are presented where a virtual wind system has one input, an oscillator-shaped wind speed, and two outputs, the wind system velocity and the electromagnetic generator torque, whose digital signal is sent to the dynamometer to establish its load torque. The validation of the proposed sensorless velocity controller is evaluated by presenting and interpreting graphic results. The tracking graph, where the motor velocity tracks the output velocity from the virtual wind system, shows that the control goal is fulfilled, which consists of emulating the turbine operation. In addition, the good performance of the robust velocity observer is validated by minimizing the estimation error of the armature current. With the emulator’s proposal, research related to wind systems can focus on the control of the electric generator, such as achieving the control goals of the wind power system, integrating the wind system operation into a smart grid, or performing stability analysis in the utility grid, among other studies.

Author Contributions

O.A.M., contributed to the design process, implementation of the wind turbine emulator using the sensorless velocity controller in real time, experimental results, and writing of the paper. R.R.-B. and F.A.V.-M. synthesized the velocity observer which is used in the control algorithm applied to the DC motor, and did a review of previous results to support the application of the controller. R.R.-C. carried out the modeling of the reference signals for the controllers from the wind turbine model, preparation and writing of the paper. C.E.C., contributed editing and presenting the experimental results, and writing the paper. J.I.H. writing the paper and improve the English language. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Tanvir, A.A.; Merabet, A.; Beguenane, R. Real-time control of active and reactive power for doubly fed induction generator (DFIG)-based wind energy conversion system. Energies 2015, 8, 10389–10408. [Google Scholar] [CrossRef] [Green Version]
  2. Wollz, D.H.; da Silva, S.A.O.; Sampaio, L.P. Real-time monitoring of an electronic wind turbine emulator based on the dynamic PMSG model using a graphical interface. Renew. Energy 2020, 155, 296–308. [Google Scholar] [CrossRef]
  3. Chen, P.Y.; Hu, K.W.; Lin, Y.G.; Liaw, C.M. Development of a prime mover emulator using a permanent-magnet synchronous motor drive. IEEE Trans. Power Electron. 2017, 33, 6114–6125. [Google Scholar] [CrossRef]
  4. Yan, J.; Feng, Y.; Dong, J. Study on dynamic characteristic of wind turbine emulator based on PMSM. Renew. Energy 2016, 97, 731–736. [Google Scholar] [CrossRef]
  5. Lin, C.H. Recurrent modified Elman neural network control of PM synchronous generator system using wind turbine emulator of PM synchronous servo motor drive. Int. J. Electr. Power Energy Syst. 2013, 52, 143–160. [Google Scholar] [CrossRef]
  6. Martínez-Márquez, C.I.; Twizere-Bakunda, J.D.; Lundback-Mompó, D.; Orts-Grau, S.; Gimeno-Sales, F.J.; Seguí-Chilet, S. Small Wind Turbine Emulator Based on Lambda-Cp Curves Obtained under Real Operating Conditions. Energies 2019, 12, 2456. [Google Scholar] [CrossRef] [Green Version]
  7. De Oliveira, J.R.; De Souza, W.G.; Rocha, M.A.; da Costa, C.F.; Le ao, J.V.F.; Andreoli, A.L. Wind Turbine Emulator Using Induction Motor Driven by Frequency Inverter and Hardware-in-the-loop Control. In Proceedings of the 2018 13th IEEE International Conference on Industry Applications (INDUSCON), Sao Paulo, Brazil, 11–14 November 2018; pp. 381–385. [Google Scholar]
  8. Sahoo, S.K.; Mondal, S.; Kastha, D.; Sinha, A.K.; Kishore, N. Wind turbine emulation using doubly fed induction motor. In Proceedings of the 2016 21st Century Energy Needs-Materials, Systems and Applications (ICTFCEN), Kharagpur, India, 17–19 November 2016; pp. 1–5. [Google Scholar]
  9. Kouadria, S.; Belfedhal, S.; Meslem, Y.; Berkouk, E.M. Development of real time Wind Turbine Emulator based on DC Motor controlled by hysteresis regulator. In Proceedings of the 2013 International Renewable and Sustainable Energy Conference (IRSEC), Ouarzazate, Morocco, 7–9 March 2013; pp. 246–250. [Google Scholar]
  10. Sirouni, Y.; El Hani, S.; Naseri, N.; Aghmadi, A.; El Harouri, K. Design and Control of a Small Scale Wind Turbine Emulator with a DC Motor. In Proceedings of the 2018 6th International Renewable and Sustainable Energy Conference (IRSEC), Rabat, Morocco, 5–8 December 2018; pp. 1–6. [Google Scholar]
  11. Balaji, M.; Sarangi, S.K.; Pattnaik, M. Design of a DC Motor based Wind Turbine Emulator using Sliding Mode Control Approach. In Proceedings of the 2019 IEEE 1st International Conference on Energy, Systems and Information Processing (ICESIP), Chennai, India, 4–6 July 2019; pp. 1–5. [Google Scholar]
  12. Moussa, I.; Khedher, A. A Theoretical and Experimental Study of a Laboratory Wind Turbine Emulator using DC-Motor Controlled by an FPGA-Based Approach. Electr. Power Components Syst. 2020, 48, 399–409. [Google Scholar] [CrossRef]
  13. Benaaouinate, L.; Khafallah, M.; Mesbahi, A.; Martinez, A. Development of a useful wind turbine emulator based on permanent magnet DC motor. In Proceedings of the 2017 14th International Multi-Conference on Systems, Signals & Devices (SSD), Marrakech, Morocco, 28–31 March 2017; pp. 44–48. [Google Scholar]
  14. Dekali, Z.; Baghli, L.; Boumediene, A. Experimental Emulation of a Small Wind Turbine under Operating Modes Using DC Motor. In Proceedings of the 2019 4th International Conference on Power Electronics and their Applications (ICPEA), Elazig, Turkey, 25–27 September 2019; pp. 1–5. [Google Scholar]
  15. Sahoo, N.; Satpathy, A.; Kishore, N.; Venkatesh, B. Dc motor-based wind turbine emulator using LabVIEW for wind energy conversion system laboratory setup. Int. J. Electr. Eng. Educ. 2013, 50, 111–126. [Google Scholar] [CrossRef]
  16. Mahdy, A.; El-Hakim, S.; Hanafy, H. Small wind turbine emulator with separately excited DC motor using analog electronic circuit. In Proceedings of the IET Conference Proceedings, Edinburgh, UK, 6–8 September 2011; p. 243. [Google Scholar]
  17. Battaiotto, P.; Mantz, R.; Puleston, P. A wind turbine emulator based on a dual DSP processor system. Control. Eng. Pract. 1996, 4, 1261–1266. [Google Scholar] [CrossRef]
  18. Burton, T.; Jenkins, N.; Sharpe, D.; Bossanyi, E. Wind Energy Handbook; John Wiley & Sons: Hoboken, NJ, USA, 2011. [Google Scholar]
  19. Voltolini, H.; Granza, M.H.; Ivanqui, J.; Carlson, R. Modeling and simulation of the Wind Turbine Emulator using induction motor driven by torque control inverter. In Proceedings of the 2012 10th IEEE/IAS International Conference on Industry Applications, Fortaleza, Brazil, 5–7 November 2012; pp. 1–6. [Google Scholar]
  20. Morfin, O.; Ruiz-Cruz, R.; Ornelas-Tellez, F.; Campos-Valdillez, A.; Ramírez-Betancour, R.; Padilla, N.; Gándara, J. Maximum wind energy capture in a wind system using a doubly-fed induction generator. In Proceedings of the 2018 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC), Guerrero, Mexico, 14–16 November 2018; pp. 1–6. [Google Scholar]
  21. Ramírez-Betancour, R.; Valenzuela-Murillo, F.A.; Martínez-Solís, F.; Casta neda-Hernández, C.E.; Morfin-Gardu no, O.A.; Olmos-López, J.A. Control de velocidad de un motor de CD basado en mediciones de la corriente de armadura. Ing. Investig. Tecnol. 2018, 19. [Google Scholar] [CrossRef]
  22. Krause, P.C.; Wasynczuk, O.; Sudhoff, S.D.; Pekarek, S. Analysis of Electric Machinery and Drive Systems; IEEE Press: Piscataway, NJ, USA, 2002. [Google Scholar]
  23. Utkin, V.; Guldner, J.; Shi, J. Sliding Mode Control in Electromechanical Systems; Taylor & Francis Ltd.: London, UK, 1999; pp. 115–129. [Google Scholar]
  24. Morfin, O.A.; Casta neda, C.E.; Valderrabano-Gonzalez, A.; Hernandez-Gonzalez, M.; Valenzuela, F.A. A real-time SOSM super-twisting technique for a compound DC motor velocity controller. Energies 2017, 10, 1286. [Google Scholar] [CrossRef] [Green Version]
  25. Chalanga, A.; Kamal, S.; Fridman, L.M.; Bandyopadhyay, B.; Moreno, J.A. Implementation of super-twisting control: Super-twisting and higher order sliding-mode observer-based approaches. IEEE Trans. Ind. Electron. 2016, 63, 3677–3685. [Google Scholar] [CrossRef]
  26. Moreno, J.A.; Osorio, M. A Lyapunov approach to second-order sliding mode controllers and observers. In Proceedings of the 2008 47th IEEE Conference on Decision and Control, Cancun, Mexico, 9–11 December 2008; pp. 2856–2861. [Google Scholar]
  27. Shtessel, Y.; Edwards, C.; Fridman, L.; Levant, A. Sliding Mode Control and Observation; Springer: Berlin/Heidelberg, Germany, 2014. [Google Scholar]
Figure 1. Power coefficient, C p .
Figure 1. Power coefficient, C p .
Energies 14 00868 g001
Figure 2. Turbine emulator scheme.
Figure 2. Turbine emulator scheme.
Energies 14 00868 g002
Figure 3. Turbine emulator prototype.
Figure 3. Turbine emulator prototype.
Energies 14 00868 g003
Figure 4. (a) Load torque; and (b) DC motor velocity.
Figure 4. (a) Load torque; and (b) DC motor velocity.
Energies 14 00868 g004
Figure 5. (a) Velocity error; and (b) control input.
Figure 5. (a) Velocity error; and (b) control input.
Energies 14 00868 g005
Figure 6. Emulator performance of the wind turbine operation (velocity tracking).
Figure 6. Emulator performance of the wind turbine operation (velocity tracking).
Energies 14 00868 g006
Figure 7. (a) Wind speed; and (b) turbine torque.
Figure 7. (a) Wind speed; and (b) turbine torque.
Energies 14 00868 g007
Figure 8. (a) Power coefficient C p ; and (b) tip-speed ratio λ .
Figure 8. (a) Power coefficient C p ; and (b) tip-speed ratio λ .
Energies 14 00868 g008
Figure 9. (a) Velocity error variable; and (b) control input performance.
Figure 9. (a) Velocity error variable; and (b) control input performance.
Energies 14 00868 g009
Figure 10. (a) Current estimation; and (b) velocity estimation.
Figure 10. (a) Current estimation; and (b) velocity estimation.
Energies 14 00868 g010
Table 1. Wind turbine parameters.
Table 1. Wind turbine parameters.
ParametersValue
Turbine Radius, R t b 0.75 m
Air Density, ρ a 1.225 kg/m 3
Inertia Momentum, J t b 0.04 N·m·s 2
Friction Coefficient, B t b 0.0024 N·m·s
Gear Box Ratio, n g b 3.0
Power, P m 180 W
Table 2. DC motor nameplate data and parameters.
Table 2. DC motor nameplate data and parameters.
DC Motor Nameplate DataDC Motor Parameters
Power180 WParameterValue
Field voltage120 VArmature resistance, R a 12.5 Ω
Field current0.5 AArmature inductance, L a 0.075 H
Armature voltage120 VMotor constant, K f 2.602
Armature current3.0 AInertia momentum, J m 0.0036 N·m·s 2
Rotor velocity1750 r.p.mFriction coefficient, B t b 0.002 N·m·s
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Morfin, O.A.; Ruiz-Cruz, R.; Hernández, J.I.; Castañeda, C.E.; Ramírez-Betancour, R.; Valenzuela-Murillo, F.A. Real-Time Sensorless Robust Velocity Controller Applied to a DC-Motor for Emulating a Wind Turbine. Energies 2021, 14, 868. https://doi.org/10.3390/en14040868

AMA Style

Morfin OA, Ruiz-Cruz R, Hernández JI, Castañeda CE, Ramírez-Betancour R, Valenzuela-Murillo FA. Real-Time Sensorless Robust Velocity Controller Applied to a DC-Motor for Emulating a Wind Turbine. Energies. 2021; 14(4):868. https://doi.org/10.3390/en14040868

Chicago/Turabian Style

Morfin, Onofre A., Riemann Ruiz-Cruz, Jesus I. Hernández, Carlos E. Castañeda, Reymundo Ramírez-Betancour, and Fredy A. Valenzuela-Murillo. 2021. "Real-Time Sensorless Robust Velocity Controller Applied to a DC-Motor for Emulating a Wind Turbine" Energies 14, no. 4: 868. https://doi.org/10.3390/en14040868

APA Style

Morfin, O. A., Ruiz-Cruz, R., Hernández, J. I., Castañeda, C. E., Ramírez-Betancour, R., & Valenzuela-Murillo, F. A. (2021). Real-Time Sensorless Robust Velocity Controller Applied to a DC-Motor for Emulating a Wind Turbine. Energies, 14(4), 868. https://doi.org/10.3390/en14040868

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics