3D Analysis of Hydrogen Distribution and Its Mitigation Using Passive Autocatalytic Recombiners (PARs) Inside VVER-1000 Containment

by
Muhammet Enis Kanik
1,
Omid Noori-kalkhoran
1,2,*,
Kevin Fernández-Cosials
3 and
Massimiliano Gei
4
1
School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
2
School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
3
Universidad Politécnica de Madrid, José Gutierrez Abascal 2, 28006 Madrid, Spain
4
Department of Engineering and Architecture, University of Trieste, Via A. Valerio 6/1, 34127 Trieste, Italy
*
Author to whom correspondence should be addressed.
Energies 2023, 16(18), 6612; https://doi.org/10.3390/en16186612
Submission received: 1 August 2023 / Revised: 30 August 2023 / Accepted: 11 September 2023 / Published: 14 September 2023
(This article belongs to the Topic Nuclear Energy Systems)

Abstract

Hydrogen is a flammable gas that can generate thermal and mechanical loads which could jeopardise the containment integrity upon combustion inside nuclear power plants containment. Hydrogen can be generated from various sources and disperses into the containment atmosphere, mixing with steam and air following a loss of coolant accident and its progression. Therefore, the volumetric hydrogen concentration should be examined within the containment to determine whether a flammable mixture is formed or not. Codes with 3D capabilities could serve this examination by providing detailed contours/maps of the hydrogen distribution inside containment in view of the local stratification phenomenon. In this study, a 3D VVER-1000 as-built containment model was sketched in AutoCAD and then processed into GOTHIC nuclear containment analysis code for hydrogen evaluation. The model was modified to a great extent by installing 80 passive autocatalytic recombiners and locating hydrogen sources to evaluate the performance of the hydrogen removal system inside the containment on maintaining the hydrogen concentration below the flammability limit during a large break loss of coolant accident. 2D profiles and 3D contours of volumetric hydrogen concentration with and without PARs are presented as the simulation outcome of this study. The results were validated against the results of the Final Safety Analysis Report, which also demonstrates the effectiveness of the hydrogen removal system as an engineered safety feature to keep the containment within a safe margin. Detailed 3D contours of hydrogen distribution inside containment can be employed to evaluate the local hot spots of hydrogen, rearranging and optimising the number and location of PARs to avoid the hydrogen explosion inside containment.
Keywords: hydrogen distribution; hydrogen mitigation; passive autocatalytic recombiner; engineering safety features; GOTHIC hydrogen distribution; hydrogen mitigation; passive autocatalytic recombiner; engineering safety features; GOTHIC

Share and Cite

MDPI and ACS Style

Kanik, M.E.; Noori-kalkhoran, O.; Fernández-Cosials, K.; Gei, M. 3D Analysis of Hydrogen Distribution and Its Mitigation Using Passive Autocatalytic Recombiners (PARs) Inside VVER-1000 Containment. Energies 2023, 16, 6612. https://doi.org/10.3390/en16186612

AMA Style

Kanik ME, Noori-kalkhoran O, Fernández-Cosials K, Gei M. 3D Analysis of Hydrogen Distribution and Its Mitigation Using Passive Autocatalytic Recombiners (PARs) Inside VVER-1000 Containment. Energies. 2023; 16(18):6612. https://doi.org/10.3390/en16186612

Chicago/Turabian Style

Kanik, Muhammet Enis, Omid Noori-kalkhoran, Kevin Fernández-Cosials, and Massimiliano Gei. 2023. "3D Analysis of Hydrogen Distribution and Its Mitigation Using Passive Autocatalytic Recombiners (PARs) Inside VVER-1000 Containment" Energies 16, no. 18: 6612. https://doi.org/10.3390/en16186612

APA Style

Kanik, M. E., Noori-kalkhoran, O., Fernández-Cosials, K., & Gei, M. (2023). 3D Analysis of Hydrogen Distribution and Its Mitigation Using Passive Autocatalytic Recombiners (PARs) Inside VVER-1000 Containment. Energies, 16(18), 6612. https://doi.org/10.3390/en16186612

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop