Next Article in Journal
Nanomedicine to Overcome Multidrug Resistance Mechanisms in Colon and Pancreatic Cancer: Recent Progress
Previous Article in Journal
Defining an Ultra-Low Risk Group in Asymptomatic IgM Monoclonal Gammopathy
Previous Article in Special Issue
The Clinical and Pathological Profile of BRCA1 Gene Methylated Breast Cancer Women: A Meta-Analysis
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Systematic Review

Fibrin Sealants and Axillary Lymphatic Morbidity: A Systematic Review and Meta-Analysis of 23 Clinical Randomized Trials

1
Department of Gynecology and Obstetrics, Ospedale Regionale di Lugano EOC, via Tesserete 46, 6900 Lugano, Switzerland
2
Faculty of Biomedical Sciences, Università della Svizzera Italiana (USI), via Giuseppe Buffi 13, 6900 Lugano, Switzerland
3
Interdisciplinary Breast Center, Department of Gynecology and Obstetrics, Klinikum Esslingen, 73730 Neckar, Germany
4
Gynecology Division, Department of Medical and Surgical Sciences and Translational Medicine, Sant’Andrea University Hospital, Sapienza University of Rome, via di Grottarossa 1035, 00189 Rome, Italy
5
Breast Surgery Unit, Department of Surgery, San Raffaele University Hospital, via Olgettina 60, 20132 Milan, Italy
6
Department of Clinical Medicine and Surgery, University of Naples Federico II, 80138 Naples, Italy
7
Emory University, Atlanta, GA 30322, USA
8
Department of Gynecology and Obstetrics, University Hospital of Augsburg, Stenglinstraße 2, 86156 Augsburg, Germany
9
Department of Obstetrics and Gynecology, University Hospital of Bern, Friedbühlstrasse 19, 3010 Bern, Switzerland
*
Author to whom correspondence should be addressed.
These authors have equally contributed.
Cancers 2021, 13(9), 2056; https://doi.org/10.3390/cancers13092056
Submission received: 10 January 2021 / Revised: 11 April 2021 / Accepted: 21 April 2021 / Published: 24 April 2021
(This article belongs to the Special Issue New Frontiers in Breast Surgical Oncology)

Abstract

:

Simple Summary

Axillary dissection is a highly mobile procedure with severe lymphatic consequences. The off-label application of fibrin sealants in the axilla, with the sole aim to eliminate dead space and to provoke sealing of the disrupted lymphatic vessels at the end of axillary dissection, is an experimental procedure to reduce lymphatic morbidity. The aim of our systematic review and meta-analysis is to investigate the effects of fibrin sealants on lymphatic morbidity after axillary dissection. Our results show that this experimental procedure is able to decrease the total axillary drainage output, the number of days before the axillary drainage is removed, and the length of hospital stay. However, no effects on the occurrence rate of axillary lymphocele or on the surgical site complications rate were demonstrated

Abstract

Background: use of fibrin sealants following pelvic, paraaortic, and inguinal lymphadenectomy may reduce lymphatic morbidity. The aim of this meta-analysis is to evaluate if this finding applies to the axillary lymphadenectomy. Methods: randomized trials evaluating the efficacy of fibrin sealants in reducing axillary lymphatic complications were included. Lymphocele, drainage output, surgical-site complications, and hospital stay were considered as outcomes. Results: twenty-three randomized studies, including patients undergoing axillary lymphadenectomy for breast cancer, melanoma, and Hodgkin’s disease, were included. Fibrin sealants did not affect axillary lymphocele incidence nor the surgical site complications. Drainage output, days with drainage, and hospital stay were reduced when fibrin sealants were applied (p < 0.0001, p < 0.005, p = 0.008). Conclusion: fibrin sealants after axillary dissection reduce the total axillary drainage output, the duration of drainage, and the hospital stay. No effects on the incidence of postoperative lymphocele and surgical site complications rate are found.

1. Introduction

Axillary lymph node dissection (ALND) was historically proposed as an integral part of the treatment of breast cancer, melanoma, and Hodgkin’s disease. In several conditions, ALND was replaced by sentinel lymph node biopsy (SLNB) as axillary staging procedure in breast cancer [1,2,3]. Full axillary lymph node dissection is restricted to node-positive cases as a therapeutic approach. This procedure can result in significant postoperative complications. One of the most common problem following full lymphadenectomy is the lymphocele. Lymphocele is a collection of fluid deriving from the excess lymphatic drainage following the removal of lymph nodes. Lymphoceles can easily be diagnosed by a clinical examination or by ultrasound. This condition may result in pain, repeated aspirations, infections, and could delay local healing and adjuvant treatments. Currently, insertion of suction drains at the time of ALND is the most common surgical method used to reduce lymphocele formation after ALND and subsequent wound complications. Drains were demonstrated to reduce the incidence of axillary lymphocele; however, they require ongoing surveillance and maintenance, entail a certain degree of discomfort, and limit physical activity [4,5]. The criteria for drain removal vary according to institutions and surgical practices (Table 1). Recently, the tendency has been to keep it in as short a time as possible, and in some centers, the possibility of not draining the axilla with postoperative drains following ALND is currently adopted. Unfortunately, even when drains are applied, the percentage of lymphocele formation is not negligible. Therefore, several additional or alternative strategies in the attempt to reduce the rate of lymphoceles and lymphatic complications occurring after a systematic lymphadenectomy were proposed. They include the closure of dead space by different means, delay of exercise, the spraying of tetracycline, the use of external compression dressing, and the use of modified dissection tools such as the harmonic scalpel. Nonetheless, none of these procedures improved the results [6,7,8]. Fibrin sealants, in the form of glue or patches, were approved as hemostatic agents across a wide range of settings, ranging from breast surgery to orthopedic surgery [9]. So far, the adoption of fibrin sealants following ALND with different aims is considered an off-label use. The prophylactic use of fibrin sealant patches has been investigated and it is still under evaluation in different fields, such as axillary, pelvic, para-aortic, and inguinal dissection. When a multi-disciplinary analysis was performed, encouraging effects were found [10]. When fibrin sealants are off-labeling, adopted to reduce the postoperative morbidity after lymph node dissection, they are applied on raw wounded areas underneath skin flaps at the end of the ALND. The rationale of this application is that fibrin seals might potentially reduce lymphocele formation by adhering previously elevated skin flaps; thus, eliminating dead space and working on lymphatic vessels in a similar way as for blood vessels [11,12,13]. The aim of this meta-analysis is to investigate the effectiveness of fibrin sealants on the incidence of lymphocele and related lymphatic morbidity after ALND, as well as to evaluate if the same results achieved in other settings, such as pelvis, inguinal area and upper abdomen, can be applied in the axilla.

2. Materials and Methods

2.1. Data Selection

This meta-analysis was performed based on the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) statement. The methodology steps from the design of the study to the manuscript writing are reported in Table A1. A systematic literature search was performed on September 2019 and repeated on August 2020, from inception. Two authors (I.G. and I.R.) independently performed the review of the literature and the studies’ selection, if there was a conflict, a third author (M.L.G.) solved it. Data were identified using the electronic databases PubMed, MEDLINE, and Scopus by searching for the terms “axillary lymphadenectomy” or “axillary dissection” and “seroma” or “lymphocele” and “fibrin sealant”. When comparing studies retrieved with the terms “axillary lymphadenectomy” and “axillary dissection”, only duplicates and/or studies out of topics were found, searching by the term “axillary dissection”; therefore, this term was excluded by the terms used in the process selection. All original reports evaluating the use of fibrin sealants on axillary lymphadenectomy and related lymphatic complications were examined for inclusion. Papers regarding various axillary lymphadenectomies performed for different malignant diseases were all evaluated for inclusion, most of them referred to breast cancer and melanoma. No study properly defined the term “lymphocele”; therefore, both seroma and lymphocele were equally adopted to define postoperative lymphatic complication consisting in a clinically or radiological finding of fluid collection after ALND. In order not to miss any other potential study, all references of original reports and reviews already published were also reviewed. All randomized controlled studies evaluating the efficacy of different fibrin sealants devices were included in the meta-analysis, including liquid (glue/gel) and non-liquid (patches) forms. The sealants could be fibrin/fibrinogen based, mixed (or not mixed) with thrombin. Only clinical randomized trials were considered in the analysis. All studies without any publication time intervals were included. No language restriction was applied in the literature search. Review articles, case reports, and letters were excluded. The following data were considered in the meta-analysis, adopted for the analysis, and summarized in the table of the included studies: first author’s information and publication year, sample size of cases and controls, type of cancer (breast cancer, melanoma, lymphoma), type of breast surgery (null, lumpectomy, quadrantectomy, mastectomy), level of axillary dissection (I, II, III), number of lymph nodes removed, number of lymph nodes involvement, type of sealant device (patch, gel, glue), quantity of the sealant device (mL for gel and glue, number of device for patches), percentages of patients undergoing neo-adjuvant chemotherapy before surgery, criteria for drainage removal, number of drainage days, incidence of postoperative axillary lymphocele, axillary drainage output (mL), days of hospital stay, surgical site complications including surgical site infections, cellulitis, fever, wound dehiscence, local inflammation, and skin necrosis among patients undergoing axillary lymphadenectomy, with and without the application of a sealant device at the end of the procedure, for the sole purpose of preventing axillary lymphadenectomy related complications. Data from surgical-site complications were pooled together and each complication was considered as an event.

2.2. Outcomes

The outcomes considered for patients undergoing axillary lymphadenectomy with or without the application of sealant devices at the end of the procedure were the following: primary outcome: incidence of postoperative axillary lymphocele; secondary outcomes: volume of lymph drained, number of drainage days, axillary drainage output, days of hospital stay, and surgical site complications.

2.3. Statistical Analysis

Dichotomous and continuous data were analyzed using Review Manager 5.3 (http://www.cochrane.org, accessed on 1 August 2020). Data for continuous outcomes were not included in the meta-analysis if standard deviations or standard errors of mean were not reported or could not be calculated. Risk of developing lymphatic morbidity in patients undergoing ALND with and without the use of sealant devices was stratified by studies and the pooled odds ratio (OR) was calculated using a fixed- or a random-effects model. Differences in the considered outcomes were stratified by studies, and the weighted mean differences (WMDs) were calculated using a fixed- or a random-effects model. A χ2 test for heterogeneity among proportions was performed to verify the presence of statistical heterogeneity between studies. Graphical representation of each study and pooled analysis were displayed by forest plots. The weight of each study was graphically represented as a square of different size. Confidence intervals (CIs) for each study were symbolized as a horizontal line passing through the square. The pooled OR or WMD was displayed as a lozenge in the forest plot and its size corresponded to the 95% CI of the OR or WMD. A p value ≤ 0.05 was defined as significant.

3. Results

Overall, 238 studies were retrieved through the literature search and six additional records were identified through reference lists. Twenty-one studies were removed as duplicates. One-hundred and eighty-nine further records were excluded after title and abstract evaluation because 179 papers did not adopt fibrin sealant devices, 8 papers were published as reviews or letters to the editor only, one paper was conducted on patients undergoing pelvic, paraaortic and inguinal lymphadenectomies for gynecological malignancies, and one paper investigated the efficacy of fibrin sealant for different outcomes. One study was excluded from the analysis due to its retrospective nature [13]. At the end of the selection process, 23/223 (10.3%) screened studies met the inclusion criteria [14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35,36]. Figure 1 shows the PRISMA flow chart outlining the process of evidence acquisition. The flow chart specifies the number of studies identified, screened, included, and excluded, as well as the reasons for exclusions. Overall, 1988 patients undergoing ALND were included in the analysis. Among them, 1884 (94.8%) patients had breast cancer; the remaining 103 and 1 patients were affected by melanoma and other cancers, and Hodgkin’s disease, respectively. In one of the series, one patient with Hodgkin’s disease underwent an axillary dissection [27]. The authors do not comment on the reason why they subjected the patient to this procedure. Nine hundred and thirty-five (47%) patients used the fibrin devices, with the scope of lymphatic complication reduction. Patients who required fibrin sealants for hemostatic reasons were excluded from the analysis. Postoperatively, suction drains were placed in every case. The characteristics of the studies and the surgical data are listed in Table 1 and Table 2, respectively. Risk of bias assessment is reported in Table 3.

3.1. Axillary Lymphocele

Seventeen trials reporting data on incidence of lymphocele could be used for the comparison. The pooled analysis showed no significant decrease in incidence of postoperative lymphocele when sealant devices were used (odds ratio: −0.03 [95%CI. −0.08, −0.02]; p 0.26, random effects model) (Figure 2). A funnel plot is available in Figure A1.

3.2. Axillary Drainage Output

Eleven trials reported data on axillary drainage output could be used for the comparison. The pooled analysis showed a significant decrease in the drainage output of those patients in whom a sealant device was used for this purpose (odds ratio: −59.72 [95%CI. −74.75, −44.7]; p < 0.0001, random effects model) (Figure 3).

3.3. Days of Hospital Stay

Six trials reporting data on hospital stay could be used for the comparison. The pooled analysis showed a significant difference in incidence of days of hospital stay when sealant devices were used for this purpose (odds ratio: −1.32 [95%CI. −2.2, 0.3]; p 0.008, random effects model) (Figure 4).

3.4. Surgical Site Complications

Nineteen trials reporting surgical site complications could be used for the comparison. The pooled analysis showed no significant difference in surgical site complications when sealant devices were used for this purpose (odds ratio: 0.99 [95%CI. 0.69, 1.41]; p 0.93, fixed effects model) (Figure 5).

3.5. Number of Days before Removal of Axillary Drainage

Ten trials reporting data on the length of drain maintenance could be used for the comparison. The pooled analysis showed a significant decrease in the number of days before axillary drainage is removed in those patients in whom a sealant device was used for this purpose (Odds Ratio: −0.8 [95%CI. −1.38, −0.24]; p = 0.005, random effects model) (Figure 6).

4. Discussion

Following ALND, a lymphocele may occur in the dead space of the axilla with an incidence of up to 85% [37,38]. Lymphocele consists in an abnormal fluid collection, causing significant morbidity, delayed wound healing, and quality of life. It can be associated with a delay in the beginning of adjuvant treatment and, consequently, affect the oncologic outcome [39,40]. Sometimes, additional surgical procedures are required in case of long-standing persistent lymphocele [41]. The most common method to reduce the incidence of the lymphocele is the use of postoperative drainage. Several randomized trials have aimed to replace the drains by reducing seroma formation in different ways, but with inconsistent results [6,42,43,44]. Advanced hemostasis was also proposed as a lymphocele prevention tool after ALND in breast cancer patients [45]. Fibrin sealants were proposed to reduce the lymphatic morbidity following various surgeries, such as cardiovascular surgery, prostate surgery, and rhytidectomy [46,47,48]. The rationale of its use is to reduce the dead space of the cavity by obliterating the potential space between tissue layers and to promote tissue healing and lymphatic vessels closure. In patients undergoing mastectomy and sentinel lymph node biopsy due to invasive breast cancer or ductal carcinoma in situ, the use of fibrin sealant reduces the postoperative lymphocele aspiration [49] and the drain-free breast surgery [50]. Very recently, some authors suggested that the use of fibrin sealants after breast surgery gave surgeons the confidence to opt for a drain-free technique, thus enhancing the day-case surgery rate [51]. When fibrin sealants are applied to prevent lymphatic morbidity following lymphadenectomies, a recent meta-analysis showed that fibrin sealant devices reduced lymphatic drainage following pelvic, para-aortic, inguinal, and axillary lymphadenectomies for gynecological malignancies and breast cancer [10]. The same investigation in the sole axillary area achieved conflicting results. When fibrin glue instillation under skin flaps was used to prevent lymphocele related morbidity following breast and axillary surgery, insufficient evidence to clearly assess the benefit on lymphocele rates and volume, complications, and length of hospital stay was achieved [52]. A more pronounced benefit was identified when non-liquid fibrin sealant devices (patches) were adopted in the same setting [24,26,27]. However, in a recent phase III clinical randomized trial, the application of fibrin sealant patches after ALND did not significantly reduce the total volume of axillary drainage. Moreover, the length of hospital stay was not increased in this group of patients [36]. In our meta-analysis, the use of a sealant device in patients undergoing ALND did not affect the incidence of postoperative lymphocele, the length of hospital stay, and the surgical site complications, neither significantly nor relevantly, despite the significant reduction observed in the total axillary drainage output and the number of days before the axillary drainage was removed. Our data reveals that the use of a fibrin sealant device after axillary dissection does not affect the incidence of postoperative lymphocele and surgical site complications; however, it reduces the total axillary drainage output, the days before the axillary drainage is removed, and the hospital stay. The strength of our meta-analysis is the exclusive selection of clinical randomized trials. Furthermore, compared to previous pool analyses considering multiple sites of lymphadenectomy, we only considered the axilla as surgical site. However, our results may be accompanied by some limitations. A potential limit is the heterogeneity arising from the single studies, included in the analysis. As for instance, no restrictions about surgical procedures and/or surgical outcomes (e.g., number of removed lymph nodes and level of ALND) are always applied in the studies, as reported in Table 2. However, since only randomized trials were included in the analysis, it is plausible to consider that the randomization reduced the risk of bias within each study. Nevertheless, the pooled analysis might be biased anyway. In order to quantify this potential bias, a risk of bias assessment was performed for each included study, as reported in Table 3. In particular, the type and stage of diseases and the surgical procedures associated to ALND in the selected studies differed and it may have affected the results. For instance, in the case of mastectomy, breast and axillary cavities communicate and therefore the drain output might be higher as compared to ALND associated with quadrantectomy or ALND alone. Similarly, in our analysis we included also studies in which level III axillary dissection was performed. It is intuitive to consider patients undergoing level III lymphadenectomy at higher risk of lymphatic complications. Given the decreasing rate of level III axillary dissection in several institutions, it would be interesting, in the future, to investigate two different subsets of patients, including those at higher and lower risk of lymphatic morbidity, separately. Secondly, all the sealant devices included in the analysis were fibrin sealants, with or without thrombin, in different quantity and forms (glue and patch). Furthermore, some studies included surgical procedures performed after neo-adjuvant chemotherapy (Table 1). Finally, the authors adopted different criteria for the drainage removal; therefore, the difference in length of drainage maintenance should be interpreted carefully. Similarly, the results regarding the days of hospital stay should be interpreted carefully due to the wide variability of the hospitalization criteria in this setting. As, for instance, in several institutions, according to internal policy, the presence of drainage is a reason for hospitalization whereas in others the drainage has a domiciliary use. Furthermore, in some institutions, the diagnosis-related reimbursement system discourages early discharge after breast surgery, thus determining a wide range on the length of hospital stay. In addition, the time window in which the included studies on this topic were published is wide. As compared to older practices, more recent policies support the day surgery or discharge in the morning following the day of breast surgery, irrespective of the axillary procedure. Therefore, data on hospital stay might be a reflection of older studies and conclusion about the length of hospital stay should be considered carefully and interpreted just as an indirect indicator. Similarly, the performance of level III dissections is also an indication of some older studies and, thus, may not reflect or be applicable to current practice. Finally, it is not clear, whether the number of positive lymph nodes may affect the post-operative lymphatic morbidity. Despite this, none of the studies on this topic performed a subgroup analysis differentiating the status of lymph node involvement in the control and experimental group, respectively. Similarly, not only the treatment the patients underwent, but also the stage of disease might have an impact on the post-operative lymphatic morbidity. A cost effectiveness analysis on the use of sealant devices to prevent lymphadenectomy related complications was not the aim of the study. An ongoing trial from the MD Anderson Cancer Center is currently active to determine whether the use of fibrin sealant applied to axillary soft tissues following ALND for melanoma can result in reduced lymphatic morbidity, and to assess patient-evaluation of outcome by performing a cost benefit analysis using a willingness-to-pay model [53]. The results of this study will probably provide useful additional evidence on the topic. Similarly, recent evidence showed a significant decrease in the rate of postoperative percutaneous aspiration of lymphocele in those patients in whom a sealant patch was used for reducing lymphatic morbidity [10]. However, this recent analysis was not applied to the sole ALND but it included pelvic, para-aortic, and inguinal lymphadenectomies. Given the current evidence and the lack of cost effectiveness analysis, we recommend a prudent use of fibrin sealants after ALND with the aim to reduce lymphatic morbidity. It might be reasonable to use fibrin sealants in those cases in which a high lymphatic output is expected such as in patients undergoing both, mastectomy and ALND (leading to a large surgical surface), high axillary tumor burden or extensive axillary surgery (e.g., including level III). In some studies, the use of hemostatic patches has been associated with an increased risk of infections [54]. It has been hypothesized that the reason for the increased risk of reported infections was rather related to the bloodier surgical procedure requiring the adoption of the patch than on the patch itself [55]. Consequently, no increased risk of infections is expected when fibrin sealants are used to reduce the lymphatic output after ALND. In fact, this was not the case in the studies reviewed in our meta-analysis.

5. Conclusions

The use of fibrin sealant devices after ALND, with the sole aim of reducing lymphatic morbidity, is able to decrease the total axillary drainage output, the number of days before the axillary drainage is removed, and the length of hospital stay. However, no effects on the occurrence of axillary lymphocele or on the surgical site complications rate were achieved. These results warrant further evidence before they can be considered conclusive. It would be useful to compare the relative costs of fibrin sealant, and its outcome, in order to determine if its use justifies its costs.

Author Contributions

M.L.G. conceived the idea, performed the statistical analysis, edited the draft; I.R., I.G. performed the literature review; V.Z., N.D., I.R., R.D.M. commented on the results; S.C.N.Q. conducted the language editing; V.B., F.M. participated in draft editing; L.S., F.D.V. completed the tables; M.D.M., A.P., O.D.G., T.K., F.B., D.C. conducted the final revision. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The data presented in this study are available in the present manuscript.

Conflicts of Interest

Authors declare to have no conflict of interest related to this article.

Appendix A

Table A1. Methodology Steps.
Table A1. Methodology Steps.
TASKDESCRIPTIONCLASSIFICATION
Formulate questionQuestion: Does the off-label use of fibrin sealant affect lymphatic morbidity after axillary dissection? Step I: preparation
Check for previous systematic review (SR)Similar SRs, but in different settings were identified and commented in the discussion. Step I: preparation
Protocol draftingAn objective and reproducible methodology was designed and reported in the “methods” paragraph of the manuscript.Step I: preparation
Search strategy definitionData were identified using the electronic databases PubMed, MEDLINE, and Scopus and strict inclusion criteria were defined. Step I: preparation
Literature search238 citations, even if many irrelevant ones included at the first literature screening.Step II: retrieval
De-duplicateTwenty-one identical citations were excluded.Step II: retrieval
Screen abstractBased on titles and abstract, the irrelevant trials were definitely removed.Step III: appraisal
Obtain full textAll the remaining studies were downloaded. When download was not allowed, a copy was requested from author or alternative library.Step II–III: retrieval and appraisal
Screen full textFurther screening was performed after carefully reading the full manuscript.Step III: appraisal
SnowballAdditional trials were found checking the citations of the included trials.Step II–III: retrieval and appraisal
Data extractionNumber of events/total and mean +/− standard deviation were collected from each sty arm.Step IV: synthesis
Literature re-checkA literature search was repeated to find new eligible trials since the initial search.Step II–IV: retrieval, appraisal, synthesis
Analysis Data were statistically combined from all the included trials.Step IV: synthesis
Manuscript draft and editing The final paper was written following the PRISMA checklist.Step V: write-up

Appendix B

Figure A1. Funnel Plot: Axillary Lymphocele.
Figure A1. Funnel Plot: Axillary Lymphocele.
Cancers 13 02056 g0a1

References

  1. Mansel, R.E.; Fallowfield, L.; Kissin, M.; Goyal, A.; Newcombe, R.G.; Dixon, J.M.; Yiangou, C.; Horgan, K.; Bundred, N.; Monypenny, I.; et al. Randomized Multicenter Trial of Sentinel Node Biopsy Versus Standard Axillary Treatment in Operable Breast Cancer: The ALMANAC Trial. J. Natl. Cancer Inst. 2006, 98, 599–609. [Google Scholar] [CrossRef] [Green Version]
  2. Ditsch, N.; Rubio, I.T.; Gasparri, M.L.; de Boniface, J.; Kuehn, T. Breast and axillary surgery in malignant breast disease: A review focused on literature of 2018 and 2019. Curr. Opin. Obstet. Gynecol. 2020, 32, 91–99. [Google Scholar] [CrossRef]
  3. Galimberti, V.; Cole, B.F.; Viale, G.; Veronesi, P.; Vicini, E.; Intra, M.; Mazzarol, G.; Massarut, S.; Zgajnar, J.; Forbes, J.; et al. Axillary dissection versus no axillary dissection in patients with breast cancer and sentinel-node micrometastases (IBCSG 23-01): 10-year follow-up of a randomised, controlled phase 3 trial. Lancet Oncol. 2018, 19, 1385–1393. [Google Scholar] [CrossRef]
  4. Droeser, R.; Frey, D.; Oertli, D.; Kopelman, D.; Peeters, M.B.-V.; Giuliano, A.; Dalberg, K.; Kallam, R.; Nordmann, A. Volume-controlled vs no/short-term drainage after axillary lymph node dissection in breast cancer surgery: A meta-analysis. Breast 2009, 18, 109–114. [Google Scholar] [CrossRef]
  5. He, X.-D.; Guo, Z.-H.; Tian, J.-H.; Yang, K.-H.; Xie, X.-D. Whether drainage should be used after surgery for breast cancer? A systematic review of randomized controlled trials. Med. Oncol. 2010, 28, 22–30. [Google Scholar] [CrossRef] [PubMed]
  6. Van Bemmel AJ, M.; Van De Velde CJ, H.; Schmitz, R.F.; Liefers, G.J. Prevention of seroma formation after axillary dissection in breast cancer: A systematic review. Eur. J. Surg. Oncol. 2011, 37, 829–835. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  7. Ten Wolde, B.; van den Wildenberg, F.J.; Polat, F.; de Wilt, J.H.; Strobbe, L.J. Can gentamicin-collagen sponges prevent seroma formation following mastectomy? Clin. Breast Cancer 2018, 18, e1023–e1026. [Google Scholar] [CrossRef]
  8. De Oliveira, M.M.F.; Gurgel, M.S.C.; Amorim, B.J.; Ramos, C.D.; Derchain, S.; Furlan-Santos, N.; Dos Santos, C.C.; Sarian, L.O. Long term effects of manual lymphatic drainage and active exercises on physical morbidities, lymphoscintigraphy parameters and lymphedema formation in patients operated due to breast cancer: A clinical trial. PLoS ONE 2018, 13, e0189176. [Google Scholar] [CrossRef] [PubMed]
  9. Uideline on The Clinical Investigation of Plasma Derived Fibrin Sealant/Haemostatic Products (CPMP/BPWG/1089/00). Available online: https://www.ema.europa.eu/en/documents/scientific-guideline/guideline-clinical-investigation-plasma-derived-fibrin-sealant/haemostatic-products-cpmp/bpwg/1089/00_en.pdf (accessed on 10 January 2021).
  10. Gasparri, M.L.; Ruscito, I.; Bolla, D.; Panici, P.B.; Mueller, M.D.; Papadia, A. The Efficacy of Fibrin Sealant Patches in Reducing the Incidence of Lymphatic Morbidity after Radical Lymphadenectomy: A Meta-Analysis. Int. J. Gynecol. Cancer 2017, 27, 1283–1292. [Google Scholar] [CrossRef] [PubMed]
  11. Roberts, I.V.; Bukhary, D.; Valdivieso, C.Y.L.; Tirelli, N. Fibrin matrices as (injectable) biomaterials: Formation, clinical use, and molecular engineering. Macromol. Biosci. 2020, 20, 1900283. [Google Scholar] [CrossRef]
  12. Fang, C.-L.; Changchien, C.-H.; Chen, M.-S.; Hsu, C.-H.; Chen, W.-C.; Yang, H.-Y.; Lin, Y.-L. The Effects of Combining Progressive Tension Sutures, Closed Drain, and Fibrin Sealant in Abdominoplasty Wound After Deep Inferior Epigastric Perforator Flap Harvesting. Ann. Plast. Surg. 2020, 84, S89–S93. [Google Scholar] [CrossRef]
  13. Vinchant, M.; Bonneau, C.; Lesavre, M.; Akerman, G.; Raiffort, C.; Barranger, E.; Bricou, A. Interest of a thrombin and fibrinogen combipatch in preventing breast cancer seroma after lymph node dissection. Gynecol. Obstet. Fertil. 2013, 41, 583–587. [Google Scholar] [CrossRef]
  14. Benevento, R.; Santoriello, A.; Pellino, G.; Sciaudone, G.; Candilio, G.; De Fatico, G.S.; Selvaggi, F.; Canonico, S. The effects of low-thrombin fibrin sealant on wound serous drainage, seroma formation and length of postoperative stay in patients undergoing axillary node dissection for breast cancer. A randomized controlled trial. Int. J. Surg. 2014, 12, 1210–1215. [Google Scholar] [CrossRef] [Green Version]
  15. Berger, A.; Tempfer, C.; Hartmann, B.; Kornprat, P.; Rossmann, A.; Neuwirth, G.; Tulusan, A.; Kubista, E. Sealing of Postoperative Axillary Leakage After Axillary Lymphadenectomy Using a Fibrin Glue Coated Collagen Patch: A Prospective Randomised Study. Breast Cancer Res. Treat. 2001, 67, 9–14. [Google Scholar] [CrossRef]
  16. Cipolla, C.; Fricano, S.; Vieni, S.; Graceffa, G.; Licari, G.; Torcivia, A.; Latteri, M.A. Does the use of fibrin glue prevent seroma formation after axillary lymphadenectomy for breast cancer? A prospective randomized trial in 159 patients. J. Surg. Oncol. 2010, 101, 600–603. [Google Scholar] [CrossRef] [PubMed]
  17. Conversano, A.; Mazouni, C.; Thomin, A.; Gaudin, A.; Fournier, M.; Rimareix, F.; Bonastre, J. Use of Low-Thrombin Fibrin Sealant Glue After Axillary Lymphadenectomy for Breast Cancer to Reduce Hospital Length and Seroma. Clin. Breast Cancer 2017, 17, 293–297. [Google Scholar] [CrossRef] [PubMed]
  18. Docimo, G.; Limongelli, P.; Conzo, G.; Gili, S.; Bosco, A.; Rizzuto, A.; Amoroso, V.; Marsico, S.; Leone, N.; Esposito, A.; et al. Axillary lymphadenectomy for breast cancer in elderly patients and fibrin glue. BMC Surg. 2013, 13, S8. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  19. Gilly, F.N.; Francois, Y.; Sayag-Beaujard, A.C.; Glehen, O.; Brachet, A.; Vignal, J. Prevention of lymphorrhea by means of fibrin glue after axillary lymphadenectomy in breast cancer: Prospective randomized trial. Eur. Surg. Res. 1998, 30, 439–443. [Google Scholar] [CrossRef]
  20. Hivelin, M.; Heusse, J.L.; Matar, N.; Lepage, C.; Lantieri, L. Fibrin sealant decreases postoperative drainage in immediate breast reconstruction by deep inferior epigastric perforator flap after mastectomy with axillary dissection. Microsurgery 2010, 31, 18–25. [Google Scholar] [CrossRef] [PubMed]
  21. Ko, E.; Han, W.; Cho, J.; Lee, J.W.; Kang, S.Y.; Jung, S.-Y.; Kim, E.-K.; Hwang, K.-T.; Noh, D.-Y. Fibrin Glue Reduces the Duration of Lymphatic Drainage after Lumpectomy and Level II or III Axillary Lymph Node Dissection for Breast Cancer: A Prospective Randomized Trial. J. Korean Med. Sci. 2009, 24, 92–96. [Google Scholar] [CrossRef] [PubMed]
  22. Medl, M.; Mayerhofer, K.; Peters-Engl, C.; Mahrhofer, P.; Huber, S.; Buxbaum, P.; Sevelda, P.; Leodolter, S. The application of fibrin glue after axillary lymphadenectomy in the surgical treatment of human breast cancer. Anticancer Res. 1995, 15, 2843–2845. [Google Scholar] [PubMed]
  23. Miri Bonjar, M.R.; Maghsoudi, H.; Samnia, R.; Saleh, P.; Parsafar, F. Efficacy of fibrin glue on seroma formation after breast surgery. Int. J. Breast Cancer 2012, 2012, 643132. [Google Scholar] [CrossRef] [PubMed]
  24. Moore, M.; E Burak, W.; Nelson, E.; Kearney, T.; Simmons, R.; Mayers, L.; Spotnitz, W.D. Fibrin sealant reduces the duration and amount of fluid1 drainage after axillary dissection: A randomized prospective clinical trial. J. Am. Coll. Surg. 2001, 192, 591–599. [Google Scholar] [CrossRef]
  25. Navarro-Rodríguez, E.; Gómez-Luque, I.; Díaz-Jiménez, N.; Rioja-Torres, P.; Bascuñana-Estudillo, G.; Ruiz-Rabelo, J.F.; Ciria-Bru, R.; Álvarez-Benito, M.; Rufián-Peña, S.; Briceño-Delgado, J. Effectiveness of an absorbable fibrin sealant patch to reduce lymphoceles formation after axillary lymphadenectomy for breast cancer: A matched-pair analysis. Am. J. Surg. 2014, 208, 824–830. [Google Scholar] [CrossRef] [PubMed]
  26. Neuss, H.; Raue, W.; Koplin, G.; Schwenk, W.; Reetz, C.; Mall, J.W. Intraoperative Application of Fibrin Sealant does not Reduce the Duration of Closed Suction Drainage Following Radical Axillary Lymph Node Dissection in Melanoma Patients: A Prospective Randomized Trial in 58 Patients. World J. Surg. 2008, 32, 1450–1455. [Google Scholar] [CrossRef] [PubMed]
  27. Piñero-Madrona, A.; Castellanos-Escrig, G.; Abrisqueta-Carrión, J.; Canteras-Jordana, M. Prospective randomized controlled study to assess the value of a hemostatic and sealing agent for preventing seroma after axillary lymphadenectomy. J. Surg. Oncol. 2016, 114, 423–427. [Google Scholar] [CrossRef] [PubMed]
  28. Ruggiero, R.; Procaccini, E.; Piazza, P.; Docimo, G.; Iovino, F.; Antoniol, G.; Irlandese, E.; Gili, S.; Schiavo, F.L. Effectiveness of fibrin glue in conjunction with collagen patches to reduce seroma formation after axillary lymphadenectomy for breast cancer. Am. J. Surg. 2008, 196, 170–174. [Google Scholar] [CrossRef] [PubMed]
  29. Ruggiero, R.; Procaccini, E.; Gili, S.; Cremone, C.; Parmeggiani, D.; Conzo, G.; Docimo, L.; Sparavigna, L.; Gubitosi, A.; Docimo, G.; et al. New trends on fibrin glue in seroma after axillary lymphadenectomy for breast cancer. G. Chir. 2009, 30, 306–310. [Google Scholar]
  30. Ruggiero, R.; Docimo, G.; Gubitosi, A.; Conzo, G.; Tolone, S.; Gili, S.; Bosco, A.; Docimo, L. Axillary lymphadenectomy for breast cancer and fibrin glue. Ann. Ital. Chir. 2012, 85, 88–92. [Google Scholar]
  31. Segura-Castillo, J.L.; Estrada-Rivera, O.; Castro-Cervantes, J.M.; Cortés-Flores, A.O.; Velázquez-Ramírez, G.A.; González-Ojeda, A. Reduction of lymphatic drainage posterior to modified radical mastectomy with the application of fibrin glue. Cirugía Cir. 2005, 73, 345–350. [Google Scholar]
  32. Swan, M.C.; Oliver, D.W.; Cassell OC, S.; Coleman, D.J.; Williams, N.; Morritt, D.G.; Giele, H.P. Randomized controlled trial of fibrin sealant to reduce postoperative drainage following elective lymph node dissection. Br. J. Surg. 2011, 98, 918–924. [Google Scholar] [CrossRef] [PubMed]
  33. Udén, P.; Aspegren, K.; Balldin, G.; Garne, J.P.; A Larsson, S. Fibrin adhesive in radical mastectomy. Eur. J. Surg. 1993, 159, 263–265. [Google Scholar]
  34. Ulusoy, A.N.; Polat, C.; Alvur, M.; Kandemir, B.; Bulut, F. Effect of Fibrin Glue on Lymphatic Drainage and on Drain Removal Time After Modified Radical Mastectomy: A Prospective Randomized Study. Breast J. 2003, 9, 393–396. [Google Scholar] [CrossRef]
  35. Vaxman, F.; Kolbe, A.; Stricher, F.; Zund, D.; Volkmar, P.; Gros, D.; Grenier, J.; Strieker, F. Does Fibrin Glue Improve Drainage after Axillary Lymph Node Dissection? Prospective and Randomized Study in Humans. Eur. Surg. Res. 1995, 27, 346–352. [Google Scholar] [CrossRef]
  36. Weber, W.P.; Tausch, C.; Hayoz, S.; Fehr, M.K.; Ribi, K.; Hawle, H.; Knauer, M. Impact of a surgical sealing patch on lymphatic drainage after axillary dissection for breast cancer: The SAKK 23/13 multicenter randomized phase III trial. Ann. Surg. Oncol. 2018, 25, 2632–2640. [Google Scholar] [CrossRef]
  37. Gonzalez, E.A.; Saltzstein, E.C.; Riedner, C.S.; Nelson, B.K. Seroma Formation Following Breast Cancer Surgery. Breast J. 2003, 9, 385–388. [Google Scholar] [CrossRef] [PubMed]
  38. Srivastava, V.; Basu, S.; Shukla, V.K. Seroma Formation after Breast Cancer Surgery: What We Have Learned in the Last Two Decades. J. Breast Cancer 2012, 15, 373–380. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  39. Hashemi, E.; Kaviani, A.; Najafi, M.; Ebrahimi, M.; Hooshmand, H.; Montazeri, A. Seroma formation after surgery for breast cancer. World J. Surg. Oncol. 2004, 2, 44. [Google Scholar] [CrossRef] [Green Version]
  40. Woodworth, P.A.; McBoyle, M.F.; Helmer, S.D.; Beamer, R.L. Seroma formation after breast cancer surgery: Incidence and predicting factors/discussions. Am. Surg. 2000, 66, 444. [Google Scholar]
  41. Stanczyk, M.; Grala, B.; Zwierowicz, T.; Maruszynski, M. Surgical resection for persistent seroma, following modified radical mastectomy. World J. Surg. Oncol. 2007, 5, 104. [Google Scholar] [CrossRef] [Green Version]
  42. Gauthier, T.; Garuchet-Bigot, A.; Marin, B.; Mollard, J.; Loum, O.; Fermeaux, V.; Jammet, I.; Kanoun, D.; Maubon, A.; Aubard, Y. Lanreotide autogel 90 mg and lymphorrhea prevention after axillary node dissection in breast cancer: A phase III double blind, randomized, placebo-controlled trial. Eur. J. Surg. Oncol. 2012, 38, 902–909. [Google Scholar] [CrossRef]
  43. O’Hea, B.J.; Ho, M.N.; Petrek, J.A. External compression dressing versus standard dressing after axillary lymphadenectomy. Am. J. Surg. 1999, 177, 450–453. [Google Scholar] [CrossRef]
  44. Shamley, D.R.; Barker, K.; Simonite, V.; Beardshaw, A. Delayed versus immediate exercises following surgery for breast cancer: A systematic review. Breast Cancer Res. Treat. 2005, 90, 263–271. [Google Scholar] [CrossRef]
  45. Gambardella, C.; Clarizia, G.; Patrone, R.; Offi, C.; Mauriello, C.; Romano, R.; Filardo, M.; Conzo, A.; Sanguinetti, A.; Polistena, A.; et al. Advanced hemostasis in axillary lymph node dissection for locally advanced breast cancer: New technology devices compared in the prevention of seroma formation. BMC Surg. 2019, 18, 125. [Google Scholar] [CrossRef]
  46. Simonato, A.; Varca, V.; Esposito, M.; Venzano, F.; Carmignani, G. The Use of a Surgical Patch in the Prevention of Lymphoceles After Extraperitoneal Pelvic Lymphadenectomy for Prostate Cancer: A Randomized Prospective Pilot Study. J. Urol. 2009, 182, 2285–2290. [Google Scholar] [CrossRef]
  47. Hester Jr, T.R.; Shire, J.R.; Nguyen, D.B.; Gerut, Z.E.; Chen, A.H.; Diamond, J.; Desmond, J.C.; Silvati-Fidell, L.; Abrams, S.Z.; Rohrich, R.J. Randomized, controlled, phase 3 study to evaluate the safety and efficacy of fibrin sealant VH S/D 4 s-apr (Artiss) to improve tissue adherence in subjects undergoing rhytidectomy. Aesthetic Surg. J. 2013, 33, 487–496. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  48. Yamamoto, K.T.; DeJoseph, L.M. Efficacy and Safety of Artiss Fibrin Tissue Sealant Use in Rhytidectomy: A Review of 120 Cases. Surg. J. 2017, 3, e69–e74. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  49. van Bastelaar, J.; Theunissen, L.L.; Snoeijs, M.G.; Beets, G.L.; Vissers, Y.L. Flap fixation using tissue glue or sutures appears to reduce seroma aspiration after mastectomy for breast cancer. Clin. Breast Cancer 2017, 17, 316–321. [Google Scholar] [CrossRef] [PubMed]
  50. Jain, P.K.; Sowdi, R.; Anderson, A.D.G.; MacFie, J. Randomized clinical trial investigating the use of drains and fibrin sealant following surgery for breast cancer. BJS 2003, 91, 54–60. [Google Scholar] [CrossRef] [PubMed]
  51. Harrison, C.; Remoundos, D.D.; Harvey, K.L.; Stoker, G.V.; MacLean, G.; Adwani, A.; Roy, P.G. Increasing the incidence of drain-free day-case mastectomies with the use of a fibrin tissue sealant; data from a single surgical center in the United Kingdom. Breast J. 2019, 25, 1090–1096. [Google Scholar] [CrossRef] [PubMed]
  52. Sajid, M.S.; Hutson, K.H.; Rapisarda, I.F.F.; Bonomi, R. Fibrin glue instillation under skin flaps to prevent seroma-related morbidity following breast and axillary surgery. Cochrane Database Syst. Rev. 2013, 5, CD009557. [Google Scholar] [CrossRef] [PubMed]
  53. ClinicalTrials.gov. Identifier: NCT00504582. Available online: https://clinicaltrials.gov/ct2/show/NCT00504582 (accessed on 10 January 2021).
  54. Fagotti, A.; Costantini, B.; Fanfani, F.; Vizzielli, G.; Rossitto, C.; Lecca, A.; Scambia, G. Risk of Postoperative Pelvic Abscess in Major Gynecologic Oncology Surgery: One-Year Single-Institution Experience. Ann. Surg. Oncol. 2010, 17, 2452–2458. [Google Scholar] [CrossRef] [PubMed]
  55. Perniola, G.; Antonilli, M.; Gasparri, M.L. Let’s Think Twice Before Abandoning Fibrillar Oxidized Regenerated Cellulose. Ann. Surg. Oncol. 2011, 18, 292. [Google Scholar] [CrossRef] [PubMed]
Figure 1. PRISMA flow diagram on the meta-analysis process.
Figure 1. PRISMA flow diagram on the meta-analysis process.
Cancers 13 02056 g001
Figure 2. Axillary lymphocele.
Figure 2. Axillary lymphocele.
Cancers 13 02056 g002
Figure 3. Axillary drainage output. The value reported for the axillary drainage output refers to the mean total drainage volume, in mL, +/− standard deviation.
Figure 3. Axillary drainage output. The value reported for the axillary drainage output refers to the mean total drainage volume, in mL, +/− standard deviation.
Cancers 13 02056 g003
Figure 4. Days of hospital stay.
Figure 4. Days of hospital stay.
Cancers 13 02056 g004
Figure 5. Surgical site complications.
Figure 5. Surgical site complications.
Cancers 13 02056 g005
Figure 6. Number of days before removal of axillary drainage.
Figure 6. Number of days before removal of axillary drainage.
Cancers 13 02056 g006
Table 1. Characteristics of the clinical randomized trials.
Table 1. Characteristics of the clinical randomized trials.
Author (Ref)Tumor TypePts Study Group/TotFibrin DeviceQuantityNACT
N (%)
Criteria for Drainage Removal (mL/24 h)
BENEVENTO 2014 [14]Breast cancer30/60Tisseel glue4 mLNR≤30
BERGER 2001 [15]Breast cancer30/60TachoSil patch1,5 patchesExcluded≤70
CIPOLLA 2010 [16]Breast cancer80/159Glue2 mLExcluded≤80
CONVERSANO 2017 [17]Breast cancer49/149Tisseel glue4 mL22 (44.9%) study group
23 (23%) control group
≤50
DOCIMO 2013 [18]Breast cancer15/30Tisseel glue2 mLNR≤100
GILLY 1994 [19]Breast cancer50/108Tisseel glue2 mLExcludedAfter 6 days
HIVELIN 2011 [20]Breast cancer15/30Tisseel glue5 mLNR≤30
KO 2009 [21]Breast cancer50/100glue2 mLExcluded≤30
MEDL 1995 [22]Breast cancer67/142TachoSil patch3 patches21 (29.2%) study group
21 (30%) control group
≤30
MIRI BONJAR 2012 [23]Breast cancer31/60glue2 mLNR≤30
MOORE 2001 [24]Breast cancer59/80glue4 mL, 8 mL, 16 mLNR≤40
NAVARRO-RODRIGUEZ 2014 [25]Breast cancer86/258TachoSil patch2 patches16 (18.6%) study group
32 (28.6%) C
≤50
NEUSS 2008 [26]Melanoma29/58Tisseel glue2 mLNR≤50
PINERO-MADRONA 2016 [27]Melanoma, Breast cancer, Hodgkin’s disease44/91TachoSil patch3 patches24≤50
RUGGIERO 2008 [28]Breast cancer25/50Glue + patch2 mLNR≤100
RUGGIERO 2009 [29]Breast cancer45/90Tisseel glue2 mLNR≤100
RUGGIERO 2014 [30]Breast cancer 40/80Tisseel glue2 mLNR≤100
SEGURA-CASTILLO 2005 [31]Breast cancer22/43Quixil gel10 mL11 (20%) study group
10 (20%) control group
≤50
SWAN 2011 [32]Melanoma
Others
18/36Tisseel glue4 mLNR≤30
UDEN 1992 [33]Breast cancer36/68Tisseel glue2 mLNR≤100
ULUSOY 2003 [34]Breast cancer27/54Tisseel glue4 mLExcluded≤20
VAXMAN 1995 [35]Breast cancer20/40Tisseel glue5 mLNR≤10
WEBER 2018 [36]Breast cancer67/142TachoSil patch3 patches21 (29.2%) study group
21 (30%) control group
≤30
Acronyms: Pts: patients; NACT: neoadjuvant chemotherapy; NR: not reported.
Table 2. Surgical data.
Table 2. Surgical data.
Author (ref)Breast SurgeryLevel of DissectionN. Nodes Removed (Median)N. Positive Nodes
(Median)
Pts with Positive Nodes
BENEVENTO 2014 [14]Quadrantectomy, mastectomyIII23.7 study group
24 control group
NRNR
BERGER 2001 [15]Lumpectomy, mastectomyIINRNRNR
CIPOLLA 2010 [16]Quadrantectomy, mastectomyIII16.6 study group
17.4 control group
NR46 study group
3 control group
CONVERSANO 2017 [17]Quadrantectomy or ALND onlyII14.5 study group
14 control group
1 study group
1 control group
NR
DOCIMO 2013 [18]Quadrantectomy, mastectomyNRNRNRNR
GILLY 1994 [19]Modified radical mastectomy, sector mastectomyIII10.6 study group
0.8 control group
1.9 study group
1.9 control group
NR
HIVELIN 2011 [20]MastectomyNRNRNRNR
KO 2009 [21]QuadrantectomyI-III12.6 study group
12.5 control group
0.8 study group
0.8 control group
NR
MEDL 1995 [22]Quadrantectomy, mastectomyNR12.8 study group
3.9 control group
4.2study group;
4.4 control group
NR
MIRI BONJAR 2012 [23]Quadrantectomy, mastectomyNR14.7study group
4.2 control group
1.2 study group
2.5 control group
NR
MOORE 2001 [24]Lumpectomy, mastectomyNRNRNRNR
NAVARRO-RODRIGUEZ 2014 [25]Quadrantectomy, mastectomyIII14.95 study group
15.66 control group
NR64 Study group
102 control group
NEUSS 2008 [26]NullIII16 study group ;
15 control group
3study group
3 control group
NR
PIERO MADRONA [27]NRII; III16.59 study group
18.36 control group
NRNR
RUGGIERO 2008 [28]Quadrantectomy, mastectomyI; II18.1 study group
18.7 control group
12 study group
13 control group
NR
RUGGIERO 2009 [29]Quadrantectomy, mastectomyI; IINRNRNR
RUGGIERO 2014 [30]Quadrantectomy, mastectomyI; IINRNRNR
SEGURA-CASTILLO 2005 [31]MastectomyIIINRNRNR
SWAN 2011 [32]NRIII18 study group
12.5 control group
NRNR
UDEN 1992 [33]MastectomyIIINRNRNR
ULUSOY 2003 [34]MastectomyIIINR5.7 study group
2.66 control group
NR
VAXMAN 1995 [35]Quadrantectomy, Patey’s mastectomyNR10.8 study group
9.3 control group
2.9 study group
2.1 control group
11 study group
11 control group
WEBER 2018 [36]QuadrantectomyII; III16 study group
18.5 control group
2 study group
3 control group
NR
Acronyms: NR: not reported.
Table 3. Risk of bias assessment.
Table 3. Risk of bias assessment.
Type of Bias Selection BiasPerformance BiasDetection BiasAttrition Bias
Study (Ref)
BENEVENTO 2014 [14]Low riskIntermediate riskLow riskIntermediate risk
BERGER 2001 [15]Low riskIntermediate riskIntermediate riskIntermediate risk
CIPOLLA 2010 [16]Low riskIntermediate riskLow risk Intermediate risk
CONVERSANO 2017 [17]Intermediate riskIntermediate riskIntermediate riskIntermediate risk
DOCIMO 2013 [18]NAIntermediate riskLow riskIntermediate risk
GILLY 1994 [19]Low riskHigh riskLow riskIntermediate risk
HIVELIN 2011 [20]NANANANA
KO 2009 [21]High riskLow riskLow riskLow risk
MEDL 1995 [22]High riskHigh riskIntermediate riskIntermediate risk
MIRI BONJAR 2012 [23]High riskLow riskLow riskIntermediate risk
MOORE 2001 [24]Low riskLow riskLow riskLow risk
NAVARRO-RODRIGUEZ 2014 [25]Low riskIntermediate riskLow riskIntermediate risk
NEUSS 2008 [26]NAIntermediate riskLow riskIntermediate risk
PINERO MADRONA [27]NALow riskLow riskLow risk
RUGGIERO 2008 [28]Intermediate riskIntermediate riskLow riskIntermediate risk
RUGGIERO 2009 [29]Intermediate riskLow riskLow riskLow risk
RUGGIERO 2014 [30]Intermediate riskLow riskIntermediate riskLow risk
SEGURA-CASTILLO 2005 [31]Low riskIntermediate riskLow riskHigh risk
SWAN 2011 [32]NALow riskLow riskLow risk
UDEN 1992 [33]Low riskIntermediate riskIntermediate riskIntermediate risk
ULUSOY 2003 [34]Low riskLow riskHigh riskLow risk
VAXMAN 1995 [35]NALow riskLow riskLow risk
WEBER 2018 [36]Low riskLow riskLow riskLow risk
Type of bias definition: selection bias: potential difference in baseline characteristics between the two groups; performance bias: potential difference in treatment, other than intervention, between the two groups; detection bias: potential difference between the two groups in how outcomes are determined; attrition bias: potential difference in loss to follow up/withdrawals between the two groups.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Gasparri, M.L.; Kuehn, T.; Ruscito, I.; Zuber, V.; Di Micco, R.; Galiano, I.; Navarro Quinones, S.C.; Santurro, L.; Di Vittorio, F.; Meani, F.; et al. Fibrin Sealants and Axillary Lymphatic Morbidity: A Systematic Review and Meta-Analysis of 23 Clinical Randomized Trials. Cancers 2021, 13, 2056. https://doi.org/10.3390/cancers13092056

AMA Style

Gasparri ML, Kuehn T, Ruscito I, Zuber V, Di Micco R, Galiano I, Navarro Quinones SC, Santurro L, Di Vittorio F, Meani F, et al. Fibrin Sealants and Axillary Lymphatic Morbidity: A Systematic Review and Meta-Analysis of 23 Clinical Randomized Trials. Cancers. 2021; 13(9):2056. https://doi.org/10.3390/cancers13092056

Chicago/Turabian Style

Gasparri, Maria Luisa, Thorsten Kuehn, Ilary Ruscito, Veronica Zuber, Rosa Di Micco, Ilaria Galiano, Siobana C. Navarro Quinones, Letizia Santurro, Francesca Di Vittorio, Francesco Meani, and et al. 2021. "Fibrin Sealants and Axillary Lymphatic Morbidity: A Systematic Review and Meta-Analysis of 23 Clinical Randomized Trials" Cancers 13, no. 9: 2056. https://doi.org/10.3390/cancers13092056

APA Style

Gasparri, M. L., Kuehn, T., Ruscito, I., Zuber, V., Di Micco, R., Galiano, I., Navarro Quinones, S. C., Santurro, L., Di Vittorio, F., Meani, F., Bassi, V., Ditsch, N., Mueller, M. D., Bellati, F., Caserta, D., Papadia, A., & Gentilini, O. D. (2021). Fibrin Sealants and Axillary Lymphatic Morbidity: A Systematic Review and Meta-Analysis of 23 Clinical Randomized Trials. Cancers, 13(9), 2056. https://doi.org/10.3390/cancers13092056

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop