Next Article in Journal
Hopping Conductivity and Dielectric Relaxations in Ag/PAN Nanocomposites
Next Article in Special Issue
Synergies of Human Umbilical Vein Endothelial Cell-Laden Calcium Silicate-Activated Gelatin Methacrylate for Accelerating 3D Human Dental Pulp Stem Cell Differentiation for Endodontic Regeneration
Previous Article in Journal
Recent Advances on Cellulose Nanocrystals and Their Derivatives
Previous Article in Special Issue
The Development of Light-Curable Calcium-Silicate-Containing Composites Used in Odontogenic Regeneration
 
 
Review
Peer-Review Record

Biomechanical Aspects of Various Attachments for Implant Overdentures: A Review

Polymers 2021, 13(19), 3248; https://doi.org/10.3390/polym13193248
by Bharat Mirchandani 1, Ting Zhou 2, Artak Heboyan 3, Sirasa Yodmongkol 4 and Borvornwut Buranawat 1,*
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Polymers 2021, 13(19), 3248; https://doi.org/10.3390/polym13193248
Submission received: 7 September 2021 / Revised: 18 September 2021 / Accepted: 20 September 2021 / Published: 24 September 2021
(This article belongs to the Special Issue Polymeric Materials for Dental Applications II)

Round 1

Reviewer 1 Report

It is a well written review, and could be accepted after minor revision. Please consider the following comments when you revise it.

  1. Table 1. There are two advantages in the Table, I think one of it should be disadvantages.
  2. I think Table 3 is unnecessary, put all the content in the paragraph is enough.

Author Response

Response to reviewer 1 comments

Thank you for your positive comments. Corrections in the Manuscript for Reviewer 1 are highlighted in Yellow color.

It is a well written review and could be accepted after minor revision. Please consider the following comments when you revise it.

Point 1: Table 1. There are two advantages in the Table, I think one of it should be disadvantages.

Response 1: There was mistake. It is corrected.

Point 2: I think Table 3 is unnecessary, put all the content in the paragraph is enough.

Response 2: Table 3 is deleted and added the contents in the paragraph.

Reviewer 2 Report

Comments on the paper:

The manuscript titled: "Biomechanical Aspects of Various Attachments for Implant Overdentures: A Review" is well written with valuable scientific information presented.

However, there are a few minor corrections that should be made.

1) Page 1, 3rd sentence, ")" is missing

2) Page 2, Table 1, please correct the structural formula for polymethyl-methacrylate (PMMA) from monomeric form to polymeric form (as the other polymeric forms in Table 1 are presented); also please correct the name from Polymetha-methacrylate to Polymethyl-methacrylate.

3)Please, correct in the same Table 1, in Polymeric materials column, "(polyoxymethyle ne copolymer) " to "(polyoxymethyle-ne copolymer) " i.e. insert "-" after "polyoxymethyle"

4) Page 4, in the paragraph under the Figure 2 please correct in the 1st sentence "40 ͦ " to"40°"

5) Page 5, Table 3, in row Yang et al. in Results column, at the end of the 2nd sentence "...except for in magnetic attachments" please omit "in"

6) Page 6, Figure 3, I suggest a small change in the title of the Figure 3, to insert "I" after "...of the first studied system..." and "II" after "...of the second studied system..." to get "...of the first studied system I (A) and of the second studied system II (B)."

7) Page 8, in Recent Advances and Future Perspective, 2nd paragraph, 2nd sentence, please correct the "polyetheretherketone" to "polyether ether ketone". Please, do the same in Figure 5 title.

Author Response

Response to reviewer 2 comments

 

Correction in the Manuscript are highlighted in Green color.

The manuscript titled: "Biomechanical Aspects of Various Attachments for Implant Overdentures: A Review" is well written with valuable scientific information presented.

However, there are a few minor corrections that should be made.

Point 1: Page 1, 3rd sentence, ")" is missing

Response 1: Corrected.

 

Point 2: Page 2, Table 1, please correct the structural formula for polymethyl-methacrylate (PMMA) from monomeric form to polymeric form (as the other polymeric forms in Table 1 are presented); also please correct the name from Polymetha-methacrylate to Polymethyl-methacrylate.

Response 2: Formula and name are corrected.

 

Point 3: Please, correct in the same Table 1, in Polymeric materials column, "(polyoxymethyle ne copolymer) " to "(polyoxymethyle-ne copolymer) " i.e. insert "-" after "polyoxymethyle"

Response 3: Name is corrected.

 

Point 4: Page 4, in the paragraph under the Figure 2 please correct in the 1st sentence "40 ͦ " to"40°"

Response 4: Corrected.

 

Point 5: Page 5, Table 3, in row Yang et al. in Results column, at the end of the 2nd sentence "...except for in magnetic attachments" please omit "in"

Response 5: Table 3 is removed as suggested by Reviewer 1. Removed in the text.

 

Point 6: Page 6, Figure 3, I suggest a small change in the title of the Figure 3, to insert "I" after "...of the first studied system..." and "II" after "...of the second studied system..." to get "...of the first studied system I (A) and of the second studied system II (B)."

Response 6: Corrected.

 

Point 7: Page 8, in Recent Advances and Future Perspective, 2nd paragraph, 2nd sentence, please correct the "polyetheretherketone" to "polyether ether ketone". Please, do the same in Figure 5 title.

Response 7: Corrected.

Back to TopTop