3. Results and Discussion
Figure 1a shows a schematic illustration of the synthesis of two types of BAF, hydrophilic and hydrophobic, through a physical etching of an MFS, followed by one-step coating with hydrophilic and hydrophobic polymers, respectively. Hydrophilic and hydrophobic BAFs were prepared by one-step coating of the bead sponge with a polymer solution of PVA/ KGM and PDMS, respectively. Hydrophilic, hydrophobic, or hybrid BAFs were loaded into the tower air filtration system (
Figure 1b). A tower air filtration system in which hybrid BAFs are actively rotated to capture PM or HCHO is proposed.
Figure 2a–d shows images of the shape variation of the cylindrical MFS while it was stirred in the beaker and wrapped in sand paper. As the stirring time increased, the sharp edge of the cylindrical MFS became round (
Figure 2b–d). After 8 h, the cylindrical MFS became almost perfectly spherical (
Figure 2d). The size of the resulting MFS bead decreased to 80% of the original size of the cylindrical MFS (
Figure 2b,d). The sizes of the MFS beads to be used as BAFs were controlled by varying the sizes of cylindrical MFSs. MFS beads with sizes of 4 mm and 9 mm were prepared and used in this study (
Figure S1). Our physical etching method enabled the mass production of homogeneous MFS beads. After the formation of the MFS beads, PVA-KGM and PDMS were separately coated onto the MFS beads to synthesize hydrophilic and hydrophobic BAFs, respectively (
Figure 2e,f).
Figure 2g–i shows scanning electron microscopy (SEM) images of a sponge (MFS) bead, the hydrophilic BAF (MFS/PVA-KGM), and the hydrophobic BAF (MFS/PDMS). The sponge bead possessed an interconnected network skeleton with a smooth surface morphology (
Figure 2g). The hydrophilic BAF (MFS/PVA-KGM) and hydrophobic BAF (MFS/PDMS) featured surface morphologies that were slightly more rough than that of the sponge bead, indicating that each polymer was coated on the sponge bead (
Figure 2h,i). No detached fragments were observed upon handling each BAF. No color changes of hydrophilic and hydrophobic BAFs were observed after the coating of each polymer on the sponge bead (
Figure 2d–f). The water contact angles (WCAs) of the sponge bead, hydrophilic BAF, and hydrophobic BAF were 0°, 0°, and 148°, indicating that MFS, MFS/PVA-KGM, and MFS/PDMS had superhydrophilic, superhydrophilic, and hydrophobic characteristics, respectively (insets of
Figure 2d–f). The absorption peaks at 3252 cm
−1 (OH), 2961 cm
−1 (aliphatic CH), 1081 cm
−1 (C-O), and 1021 cm
−1 (C-O-C), the characteristic groups in the PVA-KGM spectrum [
23,
24,
25], were increased or newly formed due to the coating of PVA-KGM for hydrophilic BAF (MFS/PVA-KGM) (red line,
Figure 2j). New absorption peaks at 1446 cm
−1 (Si-CH
3) and 1012 cm
−1 (Si-O-Si) were observed for hydrophobic BAFs (MFS/PDMS) (blue line) [
23,
24,
25]. The intensity of the peak at 792 cm
−1 related to Si-CH
3 remarkably increased for hydrophobic BAFs (MFS/PDMS) (blue line) [
23,
24,
25]. Energy dispersive X-ray (EDX) data also confirmed the synthesis of hydrophilic and hydrophobic BAFs (
Figure 2k,l and
Figure S2). The C content in the hydrophilic BAF was much higher than that in the hydrophobic BAF due to the PVA-KGM coating (
Figure 2k). Si was observed in the hydrophobic BAF due to the PDMS coating (
Figure 2l).
A tower air filtration system was composed of two parts, including an air filter section containing BAFs (top) and a fan motor section (bottom) (
Figure 3a). The air filter section consisted of an inner cylindrical frame (Cu mesh) and an outer chamber (glass). The BAFs can fly between the inner frame and outer chamber. A constant air flow was generated by the fan motor and injected into the air filter section to rotate the BAFs. A BAF with a diameter of 4 mm was used for the removal of PM. The tower air filtration system was placed in an acrylate chamber (3.63 L) containing a hazardous level of PM with PM
2.5 concentrations higher than 2500 μg/m
3. By fan motor, the PM-laden air was sucked into the bottom part of the air filtration system, passed through the filter part containing BAFs, purified, and emitted from the upper part of the air filtration system. The pressure drop was measured at input and output points by a differential pressure gauge (
Figure S3). The unfiltered PM was detected in the right part of the chamber. The air velocities generated by the fan motor were 2.4–4.4 m/s, which were an order of magnitude higher than the previously reported values [
12,
26,
27,
28]. When a constant air flow was injected into the part of the air filter containing the BAFs, the BAFs vigorously moved everywhere within the inside of the air filter part, and this phenomenon was observed in all cases (
Figure 3b).
Figure 3c shows the PM
2.5 removal efficiencies of the air filtration systems loaded with different numbers of hydrophilic BAF (MFS/PVA-KGM) (100, 200, 300, and 400). The air filtration system using 100, 200, 300, or 400 BAFs was denoted BAF-100, 200, 300, or 400. The PM
2.5 removal efficiencies of BAF-100 and BAF-200 increased, but those of BAF-300 and BAF-400 remained as analogous as that of BAF-200, which indicates that the mobilities of BAF-300 and BAF-400 were lower due to the increased bulkiness and volume (
Figure 3c). In fact, the BAF-300 and BAF-400 were not uniformly dispersed within the chamber by the fan (
Figure S4). The pressure drops of the BAFs increased as the number of BAFs increased due to the increased bulkiness and volume (
Figure 3c). However, the pressure drop of the BAF-200, which featured the highest PM
2.5 removal efficiency, was only 19 Pa at an air velocity of 3.4 m/s. Previously reported air filters feature much higher pressure drops than BAF-200 with values of 45–499 Pa, even at a much lower air velocity of 0.2 m/s. Because BAF-200 accounts for only 7.7% of the total volume of the air filter chamber, the injected air flow is seldom impeded by BAFs, causing the pressure drop to decrease. The time to reach the PM
2.5 concentration below 50 μg/m
3 was also measured for BAF-100, 200, 300, and 400. The removal time was 7 min for BAF-200 and 300 and 8 min for BAF-400 (
Figure S5a). BAF-100 never reached a PM
2.5 concentration below 50 μg/m
3 even after 10 min. Considering the PM
2.5 removal efficiency (99.2%), pressure drop (19 Pa), and removal time (7 min), BAF-200 was determined to be an optimized condition for hydrophilic BAFs.
To investigate the effect of the wettability of BAFs on the PM
2.5 removal efficiency, the PM
2.5 removal efficiency of hydrophobic and hybrid BAFs was measured and compared with that of hydrophilic BAFs. Hydrophobic BAF-200 (200 MFS/PDMS) and hybrid BAF-200 (100 MFS/PVA-KGM + 100 MFS/PDMS) were used for exact comparison. Although the samples featured analogous PM
2.5 removal efficiencies, the removal time of hybrid BAF-200 was remarkable (
Figure 3d and
Figure S5b). The removal times were 6 min and 8 min for hybrid BAF-200 and hydrophobic BAF-200, respectively, which were faster and slower than that of hydrophilic BAF-200 (7 min) (
Figure S5b). Based on the removal time (6 min), hybrid BAF-200 was the optimal BAF condition.
To reveal the reason why hybrid BAF-200 showed the best performance, the surface potentials of hydrophilic, hydrophobic, and hybrid BAF-200 were measured after the rotation of each BAF within the chamber for 5 min. Hydrophobic BAF-200s exhibited the highest surface potential, of 424 V, which was much higher than the values of 265 V and 182 V of hybrid BAF-200 and hydrophilic BAF-200, respectively (
Figure 3e). The strongest electrostatic effect of hydrophobic BAF-200 was also observed with the naked eye after the rotation of each BAF within the chamber (hydrophobic BAF-200 > hybrid BAF-200 > hydrophilic BAF-200) (
Figure S6). Through the vigorous rotation of hydrophobic BAF-200 within the glass chamber, a strong electric field can be generated through contact electrification. During the rotation of hydrophobic BAFs, the PDMS on hydrophobic BAFs generates negative charges, and the glass chamber forms positive charges according to the triboelectric series, leading to the formation of an electric field between the hydrophobic BAFs and the glass chamber. Since the PDMS of the hydrophobic BAFs and the glass of the chamber are at the opposite ends of the triboelectric series [
29], hydrophobic BAFs can obtain electrons more easily than the others. The PVA of the hydrophilic BAFs is relatively close to the glass of the chamber in the triboelectric series [
29], forming a weaker electric field than the PDMS of the hydrophobic BAFs. Thus, hydrophobic BAFs can efficiently eliminate PM using their strong electric fields. However, electric field by contact electrification may not be the main reason for hydrophilic BAFs because hydrophilic BAFs (MFS/PVA-KGM) possess a much lower surface potential (182 V) than hydrophobic BAFs (424 V).
The hydrophilic BAF (MFS/PVA-KGM) was composed of PVA and KGM, which feature high dipole moments (1.2 D and 3.1 D) [
15,
30]. These constituents can play an important role in removing PM because PM mainly consists of various hydrophilic components, such as sulfate, nitrate, silicate, calcium, chloride, and iron, and the polar groups of the constituents undergo strong dipole–dipole and induced–dipole interactions that can be used to capture PM [
7,
12]. Hybrid BAF-200 possessed both a high-dipole moment due to hydrophilic BAF-100 and a strong electric field due to hydrophobic BAF-100. Thus, PM can be removed by both effects. Hybrid BAF-200 showed analogous PM2.5 removal efficiency to the others (hybrid BAF-200 (99.4%) = hydrophobic BAF-200 (99.3%) = hydrophilic BAF-200 (99.1%)). Hybrid BAF-200 showed slightly higher PM
2.5 removal efficiency than the others (hybrid BAF-200 (99.4%) > hydrophobic BAF-200 (99.3%) > hydrophilic BAF-200 (99.1%)), while it exhibited a much higher removal time performance than the others (hybrid BAF-200 (6 min) > hydrophilic BAF-200 (7 min) > hydrophobic BAF-200 (8 min)) (
Figure 3d and
Figure S5b). The PM
2.5 removal efficiency (99.3%) of hydrophobic BAF-200 was analogous to that of hydrophilic BAF-200 (99.1%), while the removal time (7 min) of hydrophilic BAF-200 was shorter than that of hydrophobic BAF-200 (8 min) (
Figure 3d and
Figure S5b). The hydrophilic BAFs were dominant in the removal time. These results suggested that using a high dipole moment to remove PM was more suitable for lowering the removal time. Thus, the hybrid BAF, which exhibited the properties of both BAFs, offers both a fast removal time and a high PM
2.5 removal efficiency.
To further reveal the characteristics of the hybrid BAFs, comparative experiments involving a movable hybrid BAF-200 and a fixed hybrid BAF-200 were conducted to test the removal of PM because the hybrid BAFs described here were movable. To test the fixed hybrid BAF, the hybrid BAF-200 was fixed at the bottom section of the air filter chamber (
Figure S7). No movement of the hybrid BAFs was observed when PM-laden air passed through the air filter chamber. The PM
2.5 removal efficiency was lower and the pressure drop of the fixed BAFs was higher than those of the movable BAFs, which indicated that the movable BAFs were advantageous over the fixed BAFs for the removal of PM (
Figure 3f). The movable BAFs also removed the PM more quickly than the fixed BAFs (
Figure S5c). The removal time to reach the PM
2.5 concentration below 50 μg/m
3 was 6 min for the movable BAFs, while it was 9 min for the fixed BAFs, suggesting that air filtration performances can depend on the filter type (movable or fixed BAF) even if hybrid BAFs are used in tandem. The fixed hydrophilic and hydrophobic BAFs further confirmed these results. The fixed hydrophilic and hydrophobic BAF-200 were also applied to test the removal of PM. The PM
2.5 removal efficiencies of both fixed BAF-200 were lower than those of the movable BAF-200 (
Figure 3d and
Figure S8). The fixed BAFs also removed the PM more slowly than the movable BAFs (
Figures S5 and S8). Although hydrophobic BAFs showed the highest specific surface area among the samples (hydrophobic BAFs (4.28 m
2/g) > hybrid BAFs (3.93 m
2/g) > hydrophilic BAFs (3.58 m
2/g)), the fixed hydrophobic BAFs showed the lowest PM
2.5 removal efficiency (
Figures S8 and S9). The Brunauer–Emmett–Teller (BET) data reconfirmed that air filtration performances can depend on the filter type (movable or fixed BAF) rather than specific surface areas. The abovementioned results demonstrated the superiority of the movable BAF over the fixed BAF.
To investigate the size effect of the BAF on the PM
2.5 removal efficiency, an hybrid BAF with a diameter of 9 mm was prepared and compared with the hybrid BAF with a diameter of 4 mm. Fewer 9 mm-sized BAFs than 4 mm-sized BAFs were used so that the total volume of the 9 mm BAFs was equivalent to that of the 4 mm BAFs. Although the total volume of the 9 mm BAFs was the same as that of the 4 mm BAFs, the 9 mm BAFs exhibited a lower PM
2.5 removal efficiency and slower removal time than the 4 mm BAFs, which suggests that a small BAF is more favorable than a large BAF for the removal of PM due to its high mobility (
Figure 4a). An hybrid BAF with a diameter below 4 mm was not tested because the 4 mm-sized BAF was the minimum size that could be synthesized. To investigate the effect of the PM concentration on the PM
2.5 removal efficiency, the removal performance of hybrid BAF-200 was tested at low PM concentrations (500 and 1000 μg/m
3). As the PM concentrations decreased, the PM
2.5 removal efficiencies decreased (
Figure 4b). However, hybrid BAF-200 still showed a high PM
2.5 removal efficiency of 98.5%, even at a low concentration of 500 μg/m
3 (
Figure 4b). Extremely high PM
2.5 concentrations of several tens of thousands to hundreds of thousands of μg/m
3 were used for air filtration tests in previous reports, although these conditions do not meet the requirements for application in real situations. Thus, air filters must be designed and developed to capture PM at very low concentrations (several tens to hundreds of μg/m
3).
Since the air velocity was another important parameter affecting the PM removal efficiency, the PM
2.5 removal efficiencies were measured as the air velocity increased. The PM removal efficiency generally decreased as the air velocity increased because of the decreased contact time between the PM and the air filter. However, the PM
2.5 removal efficiencies of hybrid BAF-200 slightly increased to 99.9% at an air velocity of 4.4 m/s, which was slightly higher than 99.0% or 99.4% at air velocities of 2.4 m/s and 3.4 m/s, respectively (
Figure 4c). Against our expectations, the PM removal efficiency increased as the air velocity increased. The removal time to reach the PM
2.5 concentration below 50 μg/m
3 was 6 min at an air velocity of 3.4 m/s, while it was 3 min at an air velocity of 4.4 m/s (
Figure 4d). The abovementioned data suggest that the PM
2.5 removal efficiency could be enhanced even at high air velocities. To further explore this phenomenon, the surface potentials of the hybrid BAF-200 were measured under different air velocities (2.4, 3.4, and 4.4 m/s). The surface potential of hybrid BAF-200 was 213 V at an air velocity of 2.4 m/s, and it increased to 288 V at an air velocity of 4.4 m/s (
Figure 4e). The surface potential gradually increased as the air velocity increased. At high air velocities, the chance of contact between PM and the BAFs is likely lower, while the chance of contact between the glass chamber and the BAFs is likely higher, leading to the formation of a stronger electric field and the removal of PM. It was speculated that the latter case was more common than the former case. The long-term performance of the hybrid BAF-200 was also tested for the practical application of the BAF. Each cycle was 10 min, including the removal (8 min) and stabilization (2 min) times. The operation time for the long-term performance test was 9 h with up to 50 cycles. Although the PM
2.5 removal efficiencies of hybrid BAF-200 decreased to 95.9–93.4% after several cycles, the PM
2.5 removal efficiencies remained as high as 99.4–93.4% until the 50th cycle (
Figure 4f). In the absence of PMs, the weight variation of hybrid BAF-200 was monitored up to 50 cycles. After 50th cycle, the weight of hybrid BAF-200 slightly decreased to 98.8% (
Figure S10).
The adsorption of PM onto the hybrid BAFs was confirmed by several measurements.
Figure 5a,b shows SEM images of the BAFs before and after adsorption of PM. After filtration, aggregated particles were observed on the BAF surface (
Figure 5b). The BAF surface became more complicated and rough after filtration. Fourier transform infrared (FT-IR) spectroscopy was performed to further confirm the adsorption of PM. After filtration, the peak intensities at 3289 cm
−1 (-OH stretching), 1559 cm
−1 (C=C stretching), and 1443 cm
−1 (C-N stretching) increased in the spectrum of the hydrophilic BAF (MFS/PVA-KGM), which indicated the adsorption of PM onto the hydrophilic BAFs because polar functional groups and elemental carbons were present at the outer surface of the PM (
Figure 5c, red line) [
12]. However, the peak intensities at 1084 cm
−1 (C-O stretching) and 808 cm
−1 (C-O-C stretching) in the spectrum of the hydrophilic BAF were lower, which suggested the adsorption of PM onto the C-O or C-O-C group of the hydrophilic BAF (
Figure 5c, red line) [
12]. The characteristic peaks of PDMS were lower in the spectrum of the hydrophobic BAF (MFS/PDMS) at 2961 cm
−1 (-CH stretching), 1258 cm
−1 (Si-CH
3 stretching), 1016 cm
−1 (Si-O-Si stretching), and 793 cm
−1 (Si-CH
3 stretching), confirming the adsorption of PM onto the hydrophobic BAFs (
Figure 5d, blue line) [
23,
24,
25]. The amount of PM adsorbed onto the hydrophilic and hydrophobic regions of the hybrid BAFs was measured by thermogravimetric analysis (TGA). The hydrophilic BAFs possessed 6.44% more mass after filtration than before filtration, while the hydrophobic BAFs possessed 1.5% more mass after filtration than before filtration, further confirming the adsorption of PM onto both hydrophilic and hydrophobic BAFs (
Figure 5e,f). These TGA data also confirmed the greater adsorption of PM onto the hydrophilic BAFs than onto the hydrophobic BAFs. However, the PM
2.5 removal efficiencies of hydrophilic and hydrophobic BAFs were 99.1% and 99.3%, respectively, which were similar to each other. These results suggested that stronger dipole–dipole and induced–dipole interactions were the driving forces of PM capture by the hydrophilic BAFs because the detected PM was mainly adsorbed on the hydrophilic BAFs. However, a strong electric field was the main cause of PM removal from the hydrophobic BAFs because the adsorption of PM was mainly observed at the inside surface of the glass chamber rather than hydrophobic BAFs. These results were in agreement with the previous surface potential data.
To investigate the removal ability of HCHO by hydrophilic BAF-200, a tower air filtration system loaded with hydrophilic BAF-200 was placed in a chamber (3.63 L) containing a HCHO concentration of 4.87 ppm (
Figure 6a). Since the hydroxyl groups in the adsorbent can enhance the adsorption affinity of HCHO [
31], hydrophilic BAFs (MFS/PVA-KGM) were tested. To further increase the adsorption affinity, two types of hydrophilic BAF (MFS/PVA-KGM, KGM-9% and 33%) were used and compared. Hydrophilic BAFs containing KGM contents over 33% were not tested because they showed poor durability as the KGM content increased. KGM contains 11 hydroxyl groups per repeating unit (
Figure 1a). The variation in the HCHO gas concentration emitted from the chamber with and without the air filter was monitored as time increased. The fan was operated even in the absence of an air filter for exact comparison. In the absence of the air filter, the concentration of HCHO gas was 0.7 ppm at 60 min (black line), while it was 0.48 and 0.41 ppm at 60 min in the presence of hydrophilic BAF (KGM-9%) and BAF (KGM-33%), respectively (red and green lines,
Figure 6b). Against our expectations, at 130 min, the concentrations of HCHO gas remarkably increased to 0.92 ppm when no filter was used and slightly increased to 0.54 ppm with hydrophilic BAF (KGM-9%) (black and red lines, respectively). However, the concentration of HCHO gas further decreased to 0.31 ppm with the hydrophilic BAF (KGM-33%) (green line). Thus, the net removal efficiency of the hydrophilic BAF (KGM-33%) was 66% at 130 min (
Figure S11). The net removal capacities of the hydrophilic BAF (KGM-33%) and BAF (KGM-9%) for HCHO were 9.54 and 5.94 mg g
−1, respectively; these were calculated based on the concentration ratios of the HCHO at 130 min (
Figure S11). When no filter was used, HCHO could desorb from the surface of the acrylate chamber because HCHO physically adsorbed onto the inside surface of the acrylate chamber (
Figure 6b, black line). A relatively low desorption of HCHO gas was observed in the hydrophilic BAF (KGM-9%) (
Figure 6b, red line). Since the hydrophilic BAF (KGM-9%) consists of KGM containing 11 hydroxyl groups per repeating unit, the low desorption of HCHO gas could be attributed to the abundant hydroxyl groups in the hydrophilic BAF (KGM-9%), which was further confirmed by the hydrophilic BAF (KGM-33%) case. No desorption of HCHO gas was observed in the hydrophilic BAF (KGM-33%), while additional adsorption of HCHO gas was observed. These results indicated that the hydrophilic BAF (KGM-33%), which possessed more abundant hydroxyl groups than the hydrophilic BAF (KGM-9%), could stably and tightly capture more HCHO gas without any desorption of HCHO gas.
HCHO gas could be polymerized to para-HCHO due to its instability when HCHO gas was adsorbed onto the hydroxyl groups of hydrophilic BAF [
32,
33]. The para-HCHO could not desorb from the surface of the hydrophilic BAF due to the size of the para-HCHO, even when pumped under vacuum at room temperature. These results suggest that the HCHO adsorbed on the hydrophilic BAF would not desorb during daily use. According to the guidelines of the World Health Organization (WHO) [
34], the occupational exposure limit of HCHO gas is 0.5 ppm per 8 h. Hydrophilic BAF (KGM-33%) maintains HCHO concentrations of 0.41–0.31 ppm at 60–150 min, which is below the WHO guidelines (
Figure 6b, green line). However, in the absence of an air filter, the concentrations of HCHO gas were 0.7–0.92 ppm even under strong air circulation, which exceeded the WHO guidelines (
Figure 6b, black line). Previous reports did not meet the needs of real situations because extremely high HCHO concentrations of several hundred to a thousand ppm are generally used for HCHO adsorption tests [
32,
33]. The abovementioned results demonstrated that hydrophilic BAF (KGM-33%) was useful for practical concentration ranges of HCHO exposure (<5 ppm) in daily life. To confirm the adsorption of HCHO gas onto the hydrophilic BAF (KGM-33%), FT-IR spectroscopy was performed. The decrease in the -OH stretching band at 3233 cm
−1 suggested the adsorption of HCHO onto the hydroxyl group of the hydrophilic BAF (red line) [
15,
32,
33]. Six vibrational bands at 1539 cm
−1 (C=O stretching), 1441 cm
−1 (-CH stretching), 1326 cm
−1 (C-O stretching), 1086 cm
−1 (C-O-C stretching), 1078 cm
−1 (C-OH stretching), and 809 cm
−1 (CH stretching), increased in intensity and were attributed to the formation of para-HCHO (
Figure 6c, red line) [
15,
32,
33]. FT-IR data demonstrated transformation of the HCHO gas into para-HCHO in the hydrophilic BAF.