Next Article in Journal
Machine Learning and Deep Learning for Healthcare Data Processing and Analyzing: Towards Data-Driven Decision-Making and Precise Medicine
Previous Article in Journal
Quantitative MRI Assessment of Supraspinatus Tendon Remodeling Following a Single Platelet-Rich Plasma Injection Using T2 Mapping and Relaxation Time Profiling
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

First Report of Ethylenediaminetetraacetic Acid-Dependent Pseudo-Thrombocytopenia in Chile: Prevalence and Laboratory Insights

by
Mario Balcázar-Villarroel
1,*,
Florencia Carmine
2,
Francisco Torrens
3,
Katherine Birditt
4 and
Cristian Sandoval
5,6,*
1
TecnoMedic Clinical Laboratory, Puerto Montt 5502901, Chile
2
Escuela de Medicina, Facultad de Medicina, Universidad de La Frontera, Temuco 4811230, Chile
3
Institut Universitari de Ciència Molecular, Universitat de València, 46071 València, Spain
4
Physiology Development and Neuroscience Department, University of Cambridge, Cambridge CB2 1TN, UK
5
Escuela de Tecnología Médica, Facultad de Salud, Universidad Santo Tomás, Los Carreras 753, Osorno 5310431, Chile
6
Departamento de Medicina Interna, Facultad de Medicina, Universidad de La Frontera, Temuco 4811230, Chile
*
Authors to whom correspondence should be addressed.
Diagnostics 2025, 15(8), 1050; https://doi.org/10.3390/diagnostics15081050
Submission received: 24 February 2025 / Revised: 5 April 2025 / Accepted: 14 April 2025 / Published: 21 April 2025
(This article belongs to the Section Clinical Laboratory Medicine)

Abstract

:
Background: Ethylenediaminetetraacetic acid-dependent pseudo thrombocytopenia (EDTA-PCTP) is defined as a false in vitro decrease in the platelet count performed in the EDTA tube due to the spontaneous formation of platelet aggregates that prevent a correct count in hematological auto analyzers. The frequency of EDTA-PCTP varies depending on the population studied, ranging from 0.01% to 30.0%. In Chile, although the diagnosis of this condition is performed in clinical laboratories, only a few isolated reports have been described. Objectives: To determine the prevalence of EDTA-PCTP in a cohort of patients who attended an outpatient clinical laboratory in southern Chile over a period of almost 4 years. Methods: A retrospective analysis was conducted using the Laboratory Information System from January 2021 to November 2024 to identify patients with suspected and confirmed cases of EDTA-PCTP. Results: The prevalence rate observed was 0.044% (12 out of 27,480). Additionally, we established that platelet count measurement from the citrate tube at 2–5 h post-sampling was comparable to the platelet count from the EDTA/K2 tube at time 0 (p > 0.05) in these patients. Conclusions: We conclude that a relatively low prevalence of EDTA-PTCP was identified in a population of patients attending an outpatient laboratory in Chile, marking the first report of its kind in our country. Future studies may validate our findings to enhance understanding of EDTA-PTCP, thereby preventing incorrect diagnoses and treatments.

1. Introduction

Thrombocytopenia is characterized by a reduction in peripheral blood platelet count, with the clinical threshold often set at <150 × 109/L; however, patients with counts beyond 50 × 109/L are usually asymptomatic. Spontaneous bleeding is uncommon in thrombocytopenia; it occurs more commonly when the platelet count is below 20 × 109/L and is prevalent at levels below 10 × 109/L [1]. A genuine reduction may manifest in several situations, including primary immune thrombocytopenia (PIT), viral and bacterial infections, connective tissue disorders, cardiovascular illnesses, substance abuse, hematologic malignancies, and other etiologies [2]. On the other hand, among the causes of a false decrease in platelet count are ethylenediaminetetraacetic acid-dependent pseudo thrombocytopenia (EDTA-PCTP) [3], presence of giant platelets [4], platelet satellitism [5], and/or platelet phagocytosis [6]. The most frequent cause is EDTA-PCTP, defined as a false decrease in vitro platelet counts performed in the EDTA tube due to the spontaneous formation of platelet aggregates that prevent a correct count in hematological auto analyzers [3].
Since the first description of this phenomenon [7], isolated cases have been described, and the prevalence in different types of patients has been estimated. In this regard, the frequency of EDTA-PTCP varies depending on the population studied, being found between 0.01% and 0.27% in the general population [8,9], between 0.1% and 1.9% in hospitalized patients [10], and between 6.6% and 30.0% among patients investigated for thrombocytopenia [11,12]. The appearance of this phenomenon is explained by the presence of antiplatelet autoantibodies in the IgG, IgM, and/or IgA subclass. Due to the chelating effect of calcium (exerted by the EDTA found on the walls of the sample collection tube), a dissociation of the GPIIb/IIIa heterodimer found in the platelet membrane occurs. In this way, antiplatelet autoantibodies are able to bind to crypto antigens that are only exposed in the dissociated form of glycoprotein IIb, which is now exposed and generates the in vitro platelet aggregation observed in the peripheral blood smear [13]. It has been described that this aggregation, in most cases, is temperature-dependent, being more potent at room temperature than at 37 °C, therefore keeping the samples at this latter temperature can guarantee a correct platelet count in most cases, although it should be taken into account that in approximately 20–35% of them this phenomenon will continue, since it depends on the subclass and activity of the antibody involved [10]. The other important factor that explains the degree of platelet aggregation is the time elapsed between taking the venous sample and processing it in the autoanalyzer, since it has been shown that a decrease in the platelet count can occur from 10 min to 4 h after the sample collection [10].
Although there is a study that showed that EDTA-PTCP was a factor of worse prognosis in patients hospitalized in Japan [14] and another study carried out in Spain related it to autoimmune diseases [15], it has traditionally been described that this phenomenon is not clinically significant nor is it associated with any particular pathology [10]. However, its effective recognition is very important because false thrombocytopenia can determine the establishment of erroneous treatments (such as the beginning of therapy with corticosteroids), unnecessary platelet transfusion, postponement of programmed operations, postponement of discharge in hospitalized patients, delay in the start of anticoagulant and/or fibrinolytic therapy in patients with suspected acute myocardial infarction, discontinuation of heparin therapy, and even splenectomy, added to the degree of stress that can be caused for a patient and his family due to the fact of presenting an analyte outside reference values [3]. In Chile, although this phenomenon is widely diagnosed in most clinical laboratories, few cases have been published in the national literature [16], and, to our knowledge, the estimation of its prevalence in any type of population has not yet been carried out. For this reason, the objective of the present work was to determine the prevalence of EDTA-PTCP in a cohort of patients who attended an outpatient clinical laboratory in southern Chile for a period of almost four years.

2. Materials and Methods

A retrospective search was performed in the Laboratory Information System (LIS, ProActive©, Christchurch, New Zealand) of the Tecno-Medic outpatient clinical laboratory located in Puerto Montt, between January 2021 and November 2024, to identify those patients with suspected EDTA-PCTP, according to the accomplishment or one or more of the following criteria recommended by the Croatian Society of Medical Biochemistry and Laboratory Medicine [17]:
  • Decreased platelet count (<150 × 109/L) in the EDTA-dipotassium (EDTA/K2) tube (CML Biotech Ltd., Angamaly, India) processed on the Mindray BC-5380 hematology analyzer (Mindray Medical International Ltd., Shenzhen, China) in patients without clinical signs of thrombocytopenia/thrombocytopathies and without previous platelet counts;
  • A significant reduction in platelet count (delta check ≥ 40%) compared to the patient’s previous result. It should be noted that this rule applies when comparing the results of the platelet count of the same patient obtained at different times (intra-individual biological variability);
  • The presence of alarms associated with platelet and/or leukocyte counts added to an alteration in the platelet histogram.
It is important to mention that the methodology used by the hematological autoanalyzer for the platelet count was electrical impedance, which consists of encompassing variation in electric current intensity when a blood particle passes through two electrodes. This technology is used by the majority of clinical laboratories as a consequence of the larger availability of instruments based on this standard technology in the market [18]. Through this measurement, the analyzer generates a Gaussian bell-shaped graph, which combines the platelet count and volume. Any deformation in the typical shape of this graph was considered an alteration of the histogram.
Those patients who met one or more of the criteria previously specified and in whom platelet aggregates were detected, defined as the grouping of at least 5 platelets together [19] and observed according to the ICSH guidelines [20], were called for a second sample collection, this time obtaining two tubes: one tube with EDTA/K2 and one tube with 3.2% sodium citrate (CML Biotech Ltd., Angamaly, India). On the other hand, patients with no observation of platelet aggregates were confirmed as true thrombocytopenia.
Once preanalytical factors related to sample collection were excluded (such as in vitro activation of coagulation due to poor homogenization of the tube and/or clot formation due to difficult puncture), the following procedure was followed: 1. Processing of both tubes in the hematology analyzer immediately after the sample was taken (less than 5 min). It should be noted that the platelet count obtained from the tube with sodium citrate was multiplied by a factor of 1.1 due to the diluting effect of this liquid anticoagulant [19]; 2. Reprocessing of both tubes in the hematology analyzer 2–5 h after the sample was taken (kept at room temperature using a digital thermometer and air conditioner to avoid temperature fluxions due to weather conditions); and 3. Performing a peripheral blood smear, according to the above, 2–5 h after the sample was taken in both tubes for the targeted search for platelet aggregates (Figure 1).
Confirmation of EDTA-PCTP: To define a case as EDTA-PTCP, all of the following criteria had to be met [17,21]: 1. A significantly higher platelet count result was obtained in the sodium citrate tube compared to the EDTA/K2 tube in tubes processed 2–5 h after sampling; 2. Observation of platelet aggregates in the smear made from the EDTA/K2 tube at 2–5 h after sampling and not in the sodium citrate tube; 3. Absence of hemorrhagic signs or symptoms; and 4. Significant reduction in platelet count in the EDTA/K2 tube when comparing the tube processed immediately after sampling with the EDTA/K2 tube processed 2–5 h later.
Despite the criteria mentioned above, for those patients who came from external sampling rooms, more than 46 km away, only criteria 1, 2, and 3 were considered, which are sufficient to make a confirmatory diagnosis of EDTA-PCTP according to the Croatian Society of Medical Biochemistry and Laboratory Medicine [17], since the platelet counts in tubes with EDTA/K2 and sodium citrate could not be processed immediately after the sample collection due to the aforementioned distance.
To determine statistically significant differences between platelet counts performed at different times and in different tubes, the 2-tailed, paired student t test was used, with a p-value < 0.05 to be considered significant, using using the latest version of the online software GraphPad (https://www.graphpad.com/quickcalcs/ttest2/; last accessed 14 April 2025).

3. Results

Of a total of 27,480 complete blood cell counts processed in the clinical laboratory between January 2021 and November 2024, there were 12 patients who met the criteria previously indicated, so the prevalence determined was 0.044% (12/27,480). Table 1 shows that the average age of patients confirmed with EDTA-PCTP was 41.8 years, with a standard deviation (SD) of 22.1 years and a range of 12–81 years. In addition, there was a notable predominance of women over men (10 female and 2 male patients).
Table 2 shows the average platelet counts in both tubes and at different processing times. In this sense, as expected, there was a notable difference between the platelet count performed in the tube with EDTA/K2 at time 0 and the same tube at 2–5 h (p < 0.001; statistically significant differences). On the other hand, there were no differences between the platelet count in the tube with sodium citrate at both times (p = 0.1401; statistically non-significant differences); nor between the tube with EDTA/K2 and sodium citrate both at time 0 (p = 0.6997; statistically non-significant differences); nor between the tube with EDTA/K2 at time 0 and the tube with citrate at 2–5 h (p = 0.2666; statistically non-significant differences).
Visual assessment of pseudo-thrombocytopenia in blood smear using EDTA can be seen in Figure 2 and its correlation with platelet histogram changes over time in an EDTA tube can be observed in Figure 3.

4. Discussion

EDTA-PTCP is considered an infrequent phenomenon during the daily routine of a clinical laboratory. However, correct identification is essential to avoid unnecessary procedures and/or the initiation of erroneous treatments [3]. Considering its greater frequency among patients with thrombocytopenia, several guidelines have included the investigation of EDTA-PTCP in the case of a new diagnosis of PIT, recommending the observation of the peripheral blood smear by an experienced microscopist, especially when there is no correlation between the platelet count and patient’s symptoms [22,23].
Regarding the prevalence determined in our population (0.044%), this rate is similar to that determined in a hospital in Venezuela (0.035%) [24] and is exactly the same as that reported in a hospital in China (0.044%) [25]. On the other hand, our prevalence was higher than that reported in the Polish population (0.013%) [8], but lower than that reported in Italy (0.068%) [26], Canada (0.231%) [27], Israel (0.272%) [9], and Pakistan (0.278%) [28]. These differences can be explained by the different types of populations studied since it has been reported that the frequency of EDTA-PTCP is higher in hospitalized patients compared to outpatients [10]. On the other hand, the platelet count cut-off point under which EDTA-PTCP research is performed is highly variable among the different published studies (Table 3). This situation causes a wide variability in the degree of screening of patients with EDTA-PTCP, which affects the determined prevalence since a priori it is impossible to know if a patient has this condition, and it is known that the time that elapses between blood sample collection and the processing of the samples in the hematological analyzer can be very variable depending on the daily routine of each clinical laboratory, and, in addition, the time from when platelet aggregation begins to appear in the tube with EDTA can be as variable as 1 min to 4 h [10]. For this reason, we consider it reasonable to use a higher cut-off point for the investigation of EDTA-PTCP (<150 × 109/L) in order to increase the sensitivity in the screening, knowing that it has been shown that up to 20% of patients with EDTA-PTCP have platelet counts between 100 and 149 × 109/L [9].
Another variable that explains heterogeneity in the frequency of patients with EDTA-PTCP is the lack of international guidelines and/or expert committees that allow standardizing laboratory procedures for the suspicion and subsequent confirmation of patients with this condition. Despite the above, during the last years, several efforts have been made in this regard, through guidelines published by researchers [21] and national scientific organizations, such as the French-Speaking Cellular Hematology Group (GFHC) [19] and the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) [17]. In this sense, together with a knowledge of our geographical and work context, we believe it is reasonable to adopt this last guide, considering the simplicity of its suspicion and confirmation protocol, even though we would recommend the use of a higher cut-off point (150 × 109/L instead of 100 × 109/L). Another advantage of this protocol is that it only requires the following criteria for confirmation: 1. A significant increase in the platelet count in the citrate tube compared to the EDTA tube; 2. Presence of platelet aggregates in the smear from the EDTA tube; and 3. The absence of platelet aggregates was observed in the smear from the citrate tube [17]. For this reason, in some cases, it would not be necessary to collect a second sample, since if a tube with sodium citrate is available (for coagulation studies, for example), a comparison can be made between this platelet count and that of the tube with EDTA, and also a smear can be made from the tube with citrate to verify the absence of platelet aggregates, in order to have all the information necessary to confirm the EDTA-PTCP. However, it should be noted that in up to 10% to 20% of patients with EDTA-PTCP platelet aggregates may be present in the smear in both tubes, thus confirming a pseudo thrombocytopenia induced by both EDTA and sodium citrate [17], a fairly rare situation that can be resolved by different ways, such as the use of alternative anticoagulants (such as lithium heparin, disodium oxalate, hirudin, magnesium sulfate) [33], determination of the platelet count by fluorescence [34], and/or tube supplementation with kanamycin [24]. However, most of these options are usually not commercially available and/or they are too expensive, especially for developing countries or places with limited resources, which is probably why the CSMBLM recommends performing platelet counting (by the Fonio method) on peripheral blood smears taken directly from capillary blood by finger prick [17], which is a cheaper, easier, and therefore more widely available method. It should be noted that in our series of patients this phenomenon, called by some authors as multi-coagulant pseudo thrombocytopenia [35,36], did not occur, and, although there was a slight decrease in the platelet count performed in the citrate tube at 2–5 h compared to the EDTA/K2 count at time 0 (Table 2), this decrease was not statistically significant (p = 0.2666); consequently, we can conclude that the determination of the platelet count from the citrate tube at 2–5 h is equivalent to the platelet count from the EDTA/K2 tube at time 0, results that agree with those reported by Ghali et al. [37]. However, it is worth saying that it has been recommended to increase the traditional dilution factor of the citrate tube (1.1) to a higher one (1.17), especially in samples processed more than 3 h after sampling [38], although further studies would be needed for the definitive adoption of this new factor in clinical laboratories. Based on the above, we can recommend that a repeat complete blood count, performed within a short time after collection, is sufficient to obtain an accurate platelet count. If a delay is inevitable, collecting the blood in a citrate tube and the test to be performed within 5 h will also solve the problem. A normal platelet count obtained from the second sample and the absence of platelet aggregates in slides made by citrate tube proves the presence of pseudothrombocytopenia in the first sample (which has already been defined by the screening procedures), whereas a persistent thrombocytopenia in both tubes would suggest alternative diagnoses and management.
It is also important to point out the limitations of our study, the most obvious being that our series represented a relatively low number of cases (n = 12) compared to other studies with a higher number of processed complete blood cell counts, a higher number of patients confirmed with EDTA-PTCP, and/or a longer follow-up time [9,15,25,26]. However, to our knowledge, this is the first report of EDTA-PTCP prevalence in our country, since only individual cases have been described so far [16]. In this sense, our study adds to other prevalence reports in South America, such as those carried out in Venezuela [24], Argentina [31], and Brazil [32] (Table 3). On the other hand, and although it may not be considered a limitation for the objective of our study, we consider it important to point out the absence of a search for antiplatelet antibodies in the serum of patients confirmed with EDTA-PTCP due to the unavailability of this determination in our environment, which, although it does not confirm this condition, does allow establishing the subclass of immunoglobulin involved (which may be, in order of frequency, IgM, IgG, IgA, or a mixture of two immunoglobulins) [10]. Despite the above, several studies have reported that not in all cases of EDTA-PTCP can the presence of these antibodies be demonstrated, a situation that varies between 17.0% and 69.9% of cases [15,29]. Finally, although neither could it be considered a limitation to the fulfillment of the objective of our study, we consider it important to point out the lack of follow-up of patients to determine the permanence or transience over time of EDTA-PTCP, especially after an episode of acute infection, an autoimmune crisis, and/or due to the natural clearance of antiplatelet autoantibodies. In this regard, several cases of EDTA-PTCP with post-infectious presentation have been described in contexts such as COVID-19 pneumonia [39], infectious mononucleosis [40], and sepsis [41], that have persisted, even for months, remitting after recovery from the condition and returning to stable platelet counts in the EDTA tube.

5. Conclusions

We can conclude that we determined a relatively low prevalence of EDTA-PTCP in a population of patients who attended an outpatient laboratory in southern Chile, which, to our knowledge, was the first report in our country. Future research, especially prospective and multicenter studies, may confirm or discard our results in order to give them more statistical consistency and increase knowledge in our environment about EDTA-PCTP and, in this way, avoid erroneous diagnoses and/or treatments.

Author Contributions

Conceptualization, M.B.-V., F.C., F.T., K.B. and C.S.; methodology, M.B.-V., F.C., F.T. and C.S.; software, M.B.-V., F.T. and K.B.; validation, M.B.-V., F.T. and K.B. and C.S.; formal analysis, M.B.-V., F.C. and K.B.; investigation, M.B.-V., F.C. and K.B.; data curation, F.C., K.B. and C.S.; writing—original draft preparation, M.B.-V., F.C., F.T., K.B. and C.S.; writing—review and editing, M.B.-V., F.C., F.T., K.B. and C.S.; supervision, M.B.-V. and C.S.; funding acquisition: C.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research was partially financed by Asociación Universitaria Iberoamericana de Postgrado (AUIP), Programa de Becas de Movilidad Académica, PMG1-2024-044-12 and ANID, FONDECYT INI 11240623 Project. The APC was funded by Universidad de La Frontera. F.T. acknowledges the Universitat de València for the Special Research Actions Funding 2024.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author(s).

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Ashworth, I.; Thielemans, L.; Chevassut, T. Thrombocytopenia: The good, the bad and the ugly. Clin. Med. 2022, 22, 214–217. [Google Scholar] [CrossRef] [PubMed]
  2. Swain, F.; Bird, R. How I approach new onset thrombocytopenia. Platelets 2020, 31, 285–290. [Google Scholar] [CrossRef] [PubMed]
  3. Schuff-Werner, P.; Mansour, J.; Gropp, A. Pseudo-thrombocytopenia (PTCP). A challenge in the daily laboratory routine? J. Lab. Med. 2020, 44, 295–304. [Google Scholar] [CrossRef]
  4. Wang, L.; Wang, H.; Liang, H.; Ren, Z.; Gao, L. Giant Platelets Induce Double Interference in Complete Blood Count. Ann. Clin. Lab. Sci. 2019, 49, 554–556. [Google Scholar]
  5. Ghariani, I.; Braham, N.; Hamzaoui, S.; Bekir, L. Platelet satellitism in autoimmune hemolytic anemia. Curr. Res. Transl. Med. 2017, 65, 61–64. [Google Scholar] [CrossRef]
  6. Urrechaga, E.; Fernández, M. Pseudothrombocytopenia and leukocyte scattergrams: A case report. J. Lab. Precis. Med. 2022, 7, 35. [Google Scholar] [CrossRef]
  7. Gowland, E.; Kay, H.E.; Spillman, J.C.; Williamson, J.R. Agglutination of platelets by a serum factor in the presence of EDTA. J. Clin. Pathol. 1969, 22, 460–464. [Google Scholar] [CrossRef]
  8. Maslanka, K.; Marciniak-Bielak, D.; Szczepinski, A. Pseudothrombocytopenia in blood donors. Vox Sang. 2008, 95, 349. [Google Scholar] [CrossRef]
  9. Froom, P.; Barak, M. Prevalence and course of pseudothrombocytopenia in outpatients. Clin. Chem. Lab. Med. 2011, 49, 111–114. [Google Scholar] [CrossRef]
  10. Lardinois, B.; Favresse, J.; Chatelain, B.; Lippi, G.; Mullier, F. Pseudothrombocytopenia—A Review on Causes, Occurrence and Clinical Implications. J. Clin. Med. 2021, 10, 594. [Google Scholar] [CrossRef]
  11. Mao, W.Y.; Huo, M.; Ye, S.D.; Gong, W.B. Experimental analysis and countermeasures for EDTA-dependent Pseudothrombocytopenia. Zhongguo Shi Yan Xue Ye Xue Za Zhi 2014, 22, 1345–1347. [Google Scholar] [PubMed]
  12. Sinha, S.K.; Mandal, P.K.; Mallick, J. Pseudothrombocytopenia—A caveat. J. Indian Med. Assoc. 2011, 109, 476–478. [Google Scholar] [PubMed]
  13. Lin, J.; Luo, Y.; Yao, S.; Yan, M.; Li, J.; Ouyang, W.; Kuang, M. Discovery and Correction of Spurious Low Platelet Counts due to EDTA-Dependent Pseudothrombocytopenia. J. Clin. Lab. Anal. 2015, 29, 419–426. [Google Scholar] [CrossRef] [PubMed]
  14. Ohashi-Fukuda, N.; Inokuchi, R.; Sato, H.; Nakamura, K.; Iwagami, M.; Wada, T.; Jona, M.; Hisasue, T.; Nakajima, S.; Yahagi, N. Poorer prognosis with ethylenediaminetetraacetic acid-dependent pseudothrombocytopenia: A single-center case-control study. Medicine 2015, 94, e674. [Google Scholar] [CrossRef]
  15. Pujol-Moix, N.; Muñiz-Díaz, E.; Español, I.; Mojal, S.; Soler, A.; Souto, J.C. Pseudothrombocytopenia, beyond a laboratory phenomenon: Study of 192 cases. Ann. Hematol. 2023, 102, 1363–1374. [Google Scholar] [CrossRef]
  16. Benavente, R.; Araya, P.; Irausquín, M.; Peralta, F.; Jara, V. Pseudotrombocitopenia por ácido etilendiaminotetraacético (EDTA) e hipocalcemia severa inducida por ácido valproico: Reporte de un caso. In Proceedings of the XLII Congreso Chileno de Medicina Interna, Virtual, 30 September–2 October 2021; Libro de Resúmenes, Trabajos Libres. p. 133. Available online: https://www.smsextar.cl/archivos/resumen/libro_resumen_2021.pdf (accessed on 14 April 2025).
  17. Kopčinović, L.; Juričić, G.; Antončić, D.; Smaić, F.; Šimac, B.; Lapić, I.; Biljak, V. National recommendations of the Croatian Chamber of Medical Biochemists and Working group for Laboratory Hematology of the Croatian Society of Medical Biochemistry and Laboratory Medicine: Management of samples with suspected EDTA-induced pseudothrombocytopenia. Biochem. Med. 2024, 34, 030504. [Google Scholar]
  18. Krishnamurthy, V.; Shivamurthy, A.; Kumar, P.V. Platelet count in impedance-based hematology analyzer: Beware of trap! Asian J. Transfus. Sci. 2023, 17, 131–132. [Google Scholar] [CrossRef]
  19. Baccini, V.; Geneviève, F.; Jacqmin, H.; Chatelain, B.; Girard, S.; Wuilleme, S.; Vedrenne, A.; Guiheneuf, E.; Toussaint-Hacquard, M.; Everaere, F.; et al. Platelet Counting: Ugly Traps and Good Advice. Proposals from the French-Speaking Cellular Hematology Group (GFHC). J. Clin. Med. 2020, 9, 808. [Google Scholar] [CrossRef]
  20. Kratz, A.; Lee, S.H.; Zini, G.; Riedl, J.A.; Hur, M.; Machin, S.; International Council for Standardization in Haematology. Digital morphology analyzers in hematology: ICSH review and recommendations. Int. J. Lab. Hematol. 2019, 41, 437–447. [Google Scholar] [CrossRef]
  21. Lippi, G.; Plebani, M. EDTA-dependent pseudothrombocytopenia: Further insights and recommendations for prevention of a clinically threatening artifact. Clin. Chem. Lab. Med. 2012, 50, 1281–1285. [Google Scholar] [CrossRef]
  22. Provan, D.; Arnold, D.M.; Bussel, J.B.; Chong, B.H.; Cooper, N.; Gernsheimer, T.; Ghanima, W.; Godeau, B.; González-López, T.J.; Grainger, J.; et al. Updated international consensus report on the investigation and management of primary immune thrombocytopenia. Blood Adv. 2019, 3, 3780–3817. [Google Scholar] [CrossRef] [PubMed]
  23. Kashiwagi, H.; Kuwana, M.; Murata, M.; Shimada, N.; Takafuta, T.; Yamanouchi, J.; Kato, H.; Hato, T.; Tomiyama, Y.; Committee for Reference Guide for Diagnosis of Adult ITP Research Team for Coagulopathy and Other Intractable Diseases. Reference guide for the diagnosis of adult primary immune thrombocytopenia, 2023 edition. Int. J. Hematol. 2024, 119, 1–13. [Google Scholar] [CrossRef] [PubMed]
  24. Morales, M.; Moreno, A.; Mejía, M.; Bustamante, Y. Pseudotrombocitopenia EDTA-Dependiente: Rol del Laboratorio Clínico en la Detección y el Correcto Contaje Plaquetario. Rev. Fac. Med. 2001, 24, 55–61. [Google Scholar]
  25. Xiao, Y.; Yu, S.; Xu, Y. The Prevalence and Biochemical Profiles of EDTA-Dependent Pseudothrombocytopenia in a Generally Healthy Population. Acta Haematol. 2015, 134, 177–180. [Google Scholar] [CrossRef]
  26. Vicari, A.; Banfi, G.; Bonini, P.A. EDTA-dependent pseudothrombocytopaenia: A 12-month epidemiological study. Scand. J. Clin. Lab. Investig. 1988, 48, 537–542. [Google Scholar] [CrossRef]
  27. Mant, M.J.; Doery, J.C.; Gauldie, J.; Sims, H. Pseudothrombocytopenia due to platelet aggregation and degranulation in blood collected in EDTA. Scand. J. Haematol. 1975, 15, 161–170. [Google Scholar] [CrossRef]
  28. Noureen, A.; Ali, S.; Faisal, A.; Zaman, A.; Shanker, B.; Aslam, F. Pseudothrombocytopenia—Frequency, causes, and evaluation in a clinical laboratory. J. Muhammad Med. Coll. 2022, 12, 149–152. [Google Scholar] [CrossRef]
  29. Bizzaro, N. EDTA-dependent pseudothrombocytopenia: A clinical and epidemiological study of 112 cases, with 10-year follow-up. Am. J. Hematol. 1995, 50, 103–109. [Google Scholar] [CrossRef]
  30. Bartels, P.C.; Schoorl, M.; Lombarts, A.J. Screening for EDTA-dependent deviations in platelet counts and abnormalities in platelet distribution histograms in pseudothrombocytopenia. Scand. J. Clin. Lab. Investig. 1997, 57, 629–636. [Google Scholar] [CrossRef]
  31. Crimi, M.J.; Iribarne, P. Prevalencia y Causas de Pseudotrombocitopenia en un Hospital de Mendoza. Rev. Bioreview® 2019, 90, 6–22. [Google Scholar]
  32. Prates, R.; Viana, R.; Oliveira, M.; Souza, C. Pseudothrombocytopenia: Incidence and strategy for resolution in clinical laboratory. J. Bras. Patol. Med. Lab. 2017, 53, 382–387. [Google Scholar] [CrossRef]
  33. Kovacs, F.; Varga, M.; Pataki, Z.; Rigo, E. Pseudothrombocytopenia with multiple anticoagulant sample collection tubes. Interv. Med. Appl. Sci. 2016, 8, 181–183. [Google Scholar] [CrossRef] [PubMed]
  34. Witkowski, M.; Witkowska, M.; Tybura-Sawicka, M.; Majchrzak, A.; Robak, T.; Smolewski, P. Comparison of various diagnostic methods in assessing platelet count in patients with immune thrombocytopenia. Acta Haematol. Pol. 2021, 6, 584–589. [Google Scholar] [CrossRef]
  35. Arghirescu, S.; Bătăneanț, M.; Jinca, C.; Pașcalău, A.; Lelik, M.; Preja, M.; Ritli, L.; Ursu, E.; Șerban, M.; Ioniță, H. Multi-anticoagulant and EDTA-dependent pseudothrombocytopenia. Case reports on two pediatric patients. Rev. Română Med. Lab. 2014, 22, 191–198. [Google Scholar] [CrossRef]
  36. Waseem, N.; Hanif, B.; Jabbar, J. Multicoagulant resistant pseudothrombocytopenia. J. Pak. Med. Assoc. 2021, 71, 2247–2249. [Google Scholar]
  37. Ghali, C.; Scavone, M.; Clerici, B.; Bossi, E.; Fioretti, A.; Pisetta, C.; Birocchi, S.; Vismara, G.; Vozzo, N.; Cattaneo, M.; et al. Time-dependent in vitro variations of platelet count in samples from subjects with EDTA-induced pseudothrombocytopenia: A comparative analysis across different anticoagulants. Br. J. Haematol. 2024, 204, 2125–2128. [Google Scholar] [CrossRef]
  38. Dumont, P.; Goussot, V.; David, A.; Lizard, S.; Riedinger, J.M. Identification and validation of a factor of commutability between platelet counts performed on EDTA and citrate. Ann. Biol. Clin. 2017, 75, 61–66. [Google Scholar] [CrossRef]
  39. Li, H.; Wang, B.; Ning, L.; Luo, Y.; Xiang, S. Transient appearance of EDTA-dependent pseudothrombocytopenia in a patient with 2019 novel coronavirus pneumonia. Platelets 2020, 31, 825–826. [Google Scholar] [CrossRef]
  40. Hsieh, A.T.; Chao, T.Y.; Chen, Y.C. Pseudothrombocytopenia associated with infectious mononucleosis. Arch. Pathol. Lab. Med. 2003, 127, 17–18. [Google Scholar] [CrossRef]
  41. Mori, M.; Kudo, H.; Yoshitake, S.; Ito, K.; Shinguu, C.; Noguchi, T. Transient EDTA-dependent pseudothrombocytopenia in a patient with sepsis. Intensive Care Med. 2000, 26, 218–220. [Google Scholar] [CrossRef]
Figure 1. Platelet aggregation in a blood smear from a patient with EDTA-induced pseudo thrombocytopenia (A) as compared to a smear prepared from sodium citrate-anticoagulated blood from the same patient (B).
Figure 1. Platelet aggregation in a blood smear from a patient with EDTA-induced pseudo thrombocytopenia (A) as compared to a smear prepared from sodium citrate-anticoagulated blood from the same patient (B).
Diagnostics 15 01050 g001
Figure 2. Visual assessment of pseudo-thrombocytopenia in blood smear using EDTA. (A). No aggregates. (B). Moderate aggregates (++). (C). Severe aggregates (+++).
Figure 2. Visual assessment of pseudo-thrombocytopenia in blood smear using EDTA. (A). No aggregates. (B). Moderate aggregates (++). (C). Severe aggregates (+++).
Diagnostics 15 01050 g002
Figure 3. Example of platelet histogram changes over time in the EDTA/K2 tube in patient #3. Note the change in the shape of the graph between tube A and tube B, shifting from the typical bell-shaped curve to a clearly distorted curve because of the presence of an abundance of “large platelets” with sizes over 10 fL. This abnormal platelet histogram alone can be used as a quick clue to the screening and/or diagnosis of EDTA-pseudothrombocytopenia. (A). EDTA/K2 0 h. (B). EDTA/K2 3 h.
Figure 3. Example of platelet histogram changes over time in the EDTA/K2 tube in patient #3. Note the change in the shape of the graph between tube A and tube B, shifting from the typical bell-shaped curve to a clearly distorted curve because of the presence of an abundance of “large platelets” with sizes over 10 fL. This abnormal platelet histogram alone can be used as a quick clue to the screening and/or diagnosis of EDTA-pseudothrombocytopenia. (A). EDTA/K2 0 h. (B). EDTA/K2 3 h.
Diagnostics 15 01050 g003
Table 1. Clinical characteristics and platelet count from patients diagnosed with EDTA-PCTP.
Table 1. Clinical characteristics and platelet count from patients diagnosed with EDTA-PCTP.
GenderAge (Years)EDTA/K2
0 h
(×109/L)
Citrate
0 h (×109/L) *
EDTA/K2
2–5 h
(×109/L)
Citrate
2–5 h
(×109/L) *
Reason for Consultation
1Female6022322769 (4.0 h)272Control post COVID-19
2Male1823725496 (2.5 h)193Dermatological treatment for acne
3Male1621422380 (3.0 h)150Patient hospitalized awaiting discharge due to PIMS due to COVID-19
4Female12NANA45 (2.0 h)198Developmental delay
5Female2629227673 (2.0 h)202Thrombocytopenia without symptoms
6Female31NANA91 (2.0 h)303Preventive health control
7Female6626928469 (2.0 h)198Thrombocytopenia without symptoms
8Female49329339137 (2.0 h)276Thrombocytopenia without symptoms
9Female5322625654 (2.0 h)168Thrombocytopenia without symptoms
10Female5518217638 (2.0 h)134Thrombocytopenia without symptoms
11Female34NANA105 (5.0 h)278Preventive health control
12Female8118019972 (2.5 h)175Control for Parkinson’s disease and hypertension
NA: Not available. * Platelet counts in citrate tubes are already multiplied by dilution factor 1.1.
Table 2. Evaluation of differences between platelet counts.
Table 2. Evaluation of differences between platelet counts.
EDTA/K2
0 h
Citrate
0 h
EDTA/K2
2–5 h
Citrate
2–5 h
p ap bp cp dp e
Mean ± SD
(×109/L)
239.1 ± 49.5248.2 ± 48.877.4 ± 27.3212.2 ± 55.9<0.0010.14010.69970.2666<0.001
SD: standard deviation; a: comparison between EDTA/K2 0 h and EDTA/K2 2–5 h; b: comparison between sodium citrate 0 h and sodium citrate 2–5 h; c: comparison between EDTA/K2 0 h and sodium citrate 0 h; d: comparison between EDTA/K2 0 h and sodium citrate 2–5 h; e: comparison between EDTA/K2 2–5 h and sodium citrate 2–5 h.
Table 3. Frequency of EDTA-PTCP in different populations together with the cut-off used for screening.
Table 3. Frequency of EDTA-PTCP in different populations together with the cut-off used for screening.
ReferencesCountryTotal Sample SizeNumber and Frequency
of Cases (n/%)
Platelet Count Cut-Off
for Screening (×109/L)
[8]Poland76,49810/0.013%<100
[9]Israel36,780100/0.272%<150
[13]China55,00049/0.089%<100
[24]Venezuela25,3909/0.035%<150
[25]China190,94084/0.044%<80
[26]Italy33,62323/0.068%<160
[27]Canada13003/0.231%<150
[28]Pakistan18005/0.278%<100
[29]Italy430,000112/0.026%<150
[30]Netherlands45,00046/0.102%<150
[31]Argentina74034/0.054%<150
[32]Brazil28,43556/0.197%<150
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Balcázar-Villarroel, M.; Carmine, F.; Torrens, F.; Birditt, K.; Sandoval, C. First Report of Ethylenediaminetetraacetic Acid-Dependent Pseudo-Thrombocytopenia in Chile: Prevalence and Laboratory Insights. Diagnostics 2025, 15, 1050. https://doi.org/10.3390/diagnostics15081050

AMA Style

Balcázar-Villarroel M, Carmine F, Torrens F, Birditt K, Sandoval C. First Report of Ethylenediaminetetraacetic Acid-Dependent Pseudo-Thrombocytopenia in Chile: Prevalence and Laboratory Insights. Diagnostics. 2025; 15(8):1050. https://doi.org/10.3390/diagnostics15081050

Chicago/Turabian Style

Balcázar-Villarroel, Mario, Florencia Carmine, Francisco Torrens, Katherine Birditt, and Cristian Sandoval. 2025. "First Report of Ethylenediaminetetraacetic Acid-Dependent Pseudo-Thrombocytopenia in Chile: Prevalence and Laboratory Insights" Diagnostics 15, no. 8: 1050. https://doi.org/10.3390/diagnostics15081050

APA Style

Balcázar-Villarroel, M., Carmine, F., Torrens, F., Birditt, K., & Sandoval, C. (2025). First Report of Ethylenediaminetetraacetic Acid-Dependent Pseudo-Thrombocytopenia in Chile: Prevalence and Laboratory Insights. Diagnostics, 15(8), 1050. https://doi.org/10.3390/diagnostics15081050

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop