1. Introduction
The global demand for energy has been continually increasing, with the construction industry playing a significant role. Therefore, enhancing its energy efficiency becomes especially important. An overreliance on mechanical and electrical equipment to provide a comfortable environment has led to a disproportionate energy consumption in buildings, particularly from heating, ventilation, and air conditioning (HVAC) systems [
1]. In China, between 2005 and 2020, the national total energy consumption from buildings increased from 930 million tce to 2.233 billion tce, with an average annual growth rate of 6.0%. By the end of 2020, the building stock in China had reached 69.6 billion square meters [
2]. With such an immense inventory, reduction in building energy consumption has remained a key concern for both the government and society. With mild weather conditions, it is highly recommended to use natural ventilation to replace air conditioning for cooling [
3]. Compared with air conditioning systems, the cooling ability of natural ventilation seems to be limited and its performance is also not quite stable. Therefore, many researchers have moved to studying how to maximize the performance of natural ventilation in cooling buildings.
Regarding opening positions, natural ventilation can be generally categorized into three types: (1) SSV—single-sided ventilation (one or more vents are placed on one side of the building); (2) CV—cross-ventilation (allowing natural airflow through the building by having windows positioned on opposite facades), and (3) SV—stack ventilation (utilizing temperature difference between indoor and outdoor environments, with vents located at different heights) [
4]. Compared with SSV, CV generally gives higher ventilation efficiency [
5], hence it was selected in this study.
In terms of opening positions in the vertical direction, according to Karava [
6], apart from wall porosity, the relative locations of openings and exits on building facades are significant factors affecting cross-ventilation. Zhang [
7] conducted a study on two different-sized external openings and found that the most effective configuration for enhancing cross-ventilation was to have a larger opening on the leeward side than on the windward side. The aforementioned studies primarily focused on the impact of opening size and position on cross-ventilation, with limited exploration of the building’s form. However, as the roof is an integral component of the building’s form, its significance is self-evident. Roof forms can be categorized into gable roofs [
8,
9,
10], arched roofs [
11], mono-pitched roofs [
12], sawtooth roofs [
13] and various other roof types [
14,
15]. Previous studies have focused on analyzing the surface wind-pressure coefficients of these different types of roofs and providing some information on the potential for natural ventilation, but they have lacked an analysis of airflow inside buildings.
In recent years, the effects of various types of roofs and openings on the natural ventilation of buildings have been studied. Vaishnani [
16] conducted numerical simulations and used the PMV model to assess the impact of roof slope angles on cross-ventilation under winter, summer, and monsoon weather conditions in Delhi, India. The results showed that the PMV values decreased with increasing roof slope angles in winter, while in summer, the PMV values increased with greater roof slope angles. Esfeh [
17] enhanced natural ventilation capacity by adjusting the geometric shape of a semi-circular arc-shaped roof. The research revealed that the ventilation performance of the arched roof is highly sensitive to the wind angle α, with the best performance at α equals 0 and the poorest performance at 75° and 90°. Kosutova [
18] conducted a study on the impact of louvers with varying positions and fixed angles in buildings with flat roofs on natural ventilation. Building upon this foundation, Tai [
19] conducted research on the impact of louvers with different positions and angles in buildings with flat roofs on air exchange efficiency. He also proposed optimization factors to measure the relationship between AEE and DFR. Starting from roof types and roof angles, Peren [
20] conducted simulations using computational fluid dynamics (CFD) and found that, compared to buildings without eaves, the maximum increase in internal air volume flow occurred when the windward eave had a slope angle of 27°. Then Peren [
21] investigated a single-sloped roof and several other concave and convex roofs, and the results showed that convex roofs could maximize the negative pressure of the wake near the building’s exhaust vents, thereby enhancing cross-ventilation inside the building. Leite [
22], on the other hand, combined the slope angle of a single-sloped roof with the window opening position and found that the roof slope angle had a significant impact on ventilation airflow, while the vertical position of the outlet opening had a minor effect. Atmaca [
23] conducted wind-tunnel experiments and computational fluid dynamics (CFD) simulations on three differently sloped gable roofs, and found that the lowest negative pressure at all roof slopes occurred when the wind direction angle was 90 degrees. Tominaga [
24] conducted numerical simulations (CFD) to study the airflow around isolated gable-roofed buildings with different roof slopes and found significant differences in the flow fields for slope ratios of 3:10 and 5:10. Additionally, there are also studies related to wind towers, wind catchers, Mansard roofs, and other structures on rooftops [
25,
26,
27,
28,
29,
30,
31,
32,
33,
34].
A review of the literature indicates that there is almost no research on the combination of the slope angle of gable roofs and the vertical position of outlet openings. Therefore, the innovation of this study was to analyze the effects of gable roof slope angle and vertical opening position on indoor air exchange efficiency (AEE), wind-pressure coefficient, and wind speed of independent houses by using CFD method. In the remaining part of this paper,
Section 2 introduces the research methods adopted in this study.
Section 3 analyzes the results from the CFD simulation with relevant discussions. A conclusion can then be found in
Section 4.
3. Results and Discussion
To assess the impact of the roof inclination angle (RIA) and vertical opening position on ventilation airflow, a study was conducted on 18 different building models. These models encompassed three different opening positions (top–top, top–bottom, and bottom–top) and six different roof inclination angles (0°, 9°, 18°, 27°, 36°, and 45°). To facilitate a smooth comparison, the above models had the following characteristics: (1) identical internal volumes, (2) identical inlet and outlet opening sizes, and (3) different exit and entrance locations.
Figure 6 and
Figure 7 illustrate three different opening positions and various angles of gable roofs.
3.1. Pressure Coefficient, Cp
The pressure coefficient
Cp is defined as the dimensionless ratio of static pressure at a specific location to the freestream static pressure, as shown in Equation (48). The contour lines of pressure coefficients are presented in
Table 3. It can be observed that, with the same opening configuration, as the slope increased, the pressure stagnation region at the top of the building gradually shifted towards the highest point of the roof, and the leeward-side openings typically exhibited negative
Cp values. In various building cases, the negative pressure difference at the building’s windward outlets was consistently greater than the positive pressure difference at the windward inlets, indicating that the roof slope angle is a crucial parameter for enhancing wind-driven natural cross-ventilation.
3.2. Dimensionless U/Uref
The dimensionless quantity
U/
Uref was obtained by dividing the average streamwise velocity
U by the reference velocity
Uref (7.4 m/s). The contour lines of the dimensionless quantity
U/
Uref are depicted in
Table 4. From
Table 4 and
Table 5, it can be observed that there was a notable increase in flow velocity in the opening region, a phenomenon evident across all models. Through observation, it was noted that when the opening configuration was top–top or top–bottom, the flow velocity in the exhaust opening area increased with changes in the roof slope, reaching its maximum at 45°, with an acceleration rate 1.2 times that of a flat roof. Conversely, in the case of a bottom–top opening configuration, due to the Coanda effect, the airflow remained attached to the building’s bottom, resulting in a lack of sensitivity of flow velocity in the exhaust opening area to changes in roof angle, with flow velocity remaining relatively constant at around 0.6. Overall, the airflow velocity in the exhaust opening area was more sensitive to the vertical opening position than to the slope angle of the gable roof.
3.3. Air Exchange Efficiency (AEE)
Air exchange efficiency represents the efficiency of external air flushing the interior of a ventilated building [
40]. The AEE is defined by Equation (53), where
τr represents the AOA at the leeward openings, and
τav is the average volume-averaged AOA within the building.
AOA is calculated using the following scalar transport equation [
41].
where
φ represents the scalar being solved for, i.e., AOA, with
Sφ = 1 denoting the source term. The diffusion coefficient
Γ is determined using a specific formula [
41].
where
D = 2.88 × 10
−5m
−2/s represents the laminar viscosity of air at a working temperature of 20 °C,
μt is the local turbulent viscosity, and
Sct = 0.7 is the turbulent Schmidt number.
Under steady-state conditions, the term ∂ (ρφ)/∂t in Equation (54) equals zero. The transport equation was implemented in FLUENT using user-defined scalars (UDS) to compute AOA within the building. Equation (55) was employed to determine boundary conditions, setting zero values at the inlet and zero gradients at the walls and exit surfaces.
Table 6 presents the AOA distribution for all operating conditions,
Figure 8 illustrates the percentage of AEE for all conditions, and
Figure 9 displays the average volume AOA within the building. From
Table 4, it can be observed that in the top–top opening configuration, at 0°, the AOA between the windward-facing window and the roof was relatively high, gradually decreasing with an increase in roof angle, reaching an optimum at 36°. In the top–bottom configuration, the AOA between the windward-facing window and the roof was lower but higher than the ground as the roof angle increased, with the ground portion of AOA gradually decreasing. In the bottom–top configuration, the formation of eddies within the building led to excessively high AOA in the central region of the structure, and it was insensitive to changes in roof slope.
From
Figure 8, it can be observed that the AEE was highest at 45° top–bottom, reaching 48.1%, and lowest at 27° bottom–top, at only 31.4%. In the top–top opening configuration, the AEE for the flat roof was highest at 42.5%, while the AEE for the other five angles was around 32%. This indicates that in this configuration, AEE is not highly sensitive to changes in the gable roof angle. In the top–bottom opening configuration, AEE increased with an increase in roof slope angle, reaching its peak at 45°, at 48.1%. This suggests that in this configuration, the angle of the gable roof effectively promotes indoor airflow, thereby enhancing AEE.
In the bottom–top opening configuration, the AEE for roofs with different slope angles was quite similar, averaging around 32%. This suggests that AEE is not highly sensitive to changes in the gable roof angle in this configuration. Due to the presence of low–high windows, it is easy for vortices to form within the building, leading to a relatively low AEE.
Figure 9 reveals that in the top–bottom opening configuration with a gable roof slope angle of 45°, τav was at its lowest, measuring 0.33 s. In the bottom–top opening configuration with a roof slope angle of 18°, τav was highest, at 0.6 s. When considering
Figure 8 and
Figure 9 together, it becomes evident that τav maintained a strong negative correlation with AEE. When τav was low, AEE tended to be high, and conversely, when AEE was high, τav was low.
4. Conclusions
The impact of gable roofs with varying slope angles and different vertical opening positions was investigated. The opening configurations included: (1) top–top, (2) top–bottom, and (3) bottom–top, with gable roof angles of 0°, 9°, 18°, 27°, 36°, and 45°, hence a total number of 18 combinations. The design of the computational domain adhered to best practices outlined in the literature and was simulated numerically with the inclusion of an atmospheric boundary layer (ABL). Reference grids underwent grid sensitivity analysis, and numerical simulations were carried out using the SST k-omega model, with results demonstrating good consistency. Subsequently, an analysis of internal velocities, pressure coefficients, AOA, AEE, and other parameters was conducted, contributing to the advancements made in this study.
- (1)
In all configurations in this paper, the slope angle of the roof and the vertical opening positions did appear to have a significant impact on the wind-pressure coefficients.
- (2)
In terms of flow velocity, favorable opening positions were more conducive to an acceleration in velocity. With the top–bottom opening configuration, the wind speed at the windward opening was greater than that in the other two opening configurations.
- (3)
The highest AEE was 48.1%, obtained with the opening configuration of top–bottom and a roof slope angle of 45°, while the lowest AEE was 31.4%, achieved with the opening configuration of bottom–top and a roof slope angle of 27°.
- (4)
When the opening configuration was top–bottom, the slope angle of gable roofs had a significant impact on AEE, with a 5.5% relative increase in AEE for a 45° gable roof compared to a flat roof. This configuration is encouraged for use in buildings.
- (5)
When the opening configuration was bottom–top, the slope angle of the gable roof had a very limited impact on the profile wind speed and AEE. Therefore, it is not recommended to use this opening configuration in buildings.
In conclusion, this research has shown that in cross-ventilation, the slope angle of gable roofs and the vertical opening positions play crucial roles in internal airflow, pressure coefficients, AEE, AOA, and other parameters. It is hoped that through this study, buildings’ reliance on mechanical cooling can be reduced. Future work should include, but not be limited to, researching wind speed profiles and pressure coefficients under different wind directions or introducing various types of guiding windows and more complex ventilated roofs on the basis of existing openings and studying their ventilation performance.