Solar Radiation Measurement Tools and Their Impact on In Situ Testing—A Portuguese Case Study

by
Marta Oliveira
1,*,
Hélder Silva Lopes
2,
Paulo Mendonça
3,
Martin Tenpierik
4 and
Lígia Torres Silva
5
1
Centre for Territory, Environment and Construction (CTAC), Department of Civil Engineering, Engineering School, University of Minho, 4800-058 Guimarães, Portugal
2
Lab2PT—Landscape, Heritage and Territory Laboratory, Department of Geography, University of Minho, 4800-058 Guimarães, Portugal
3
Lab2PT—Landscape, Heritage and Territory Laboratory, School of Architecture, Art and Design, University of Minho, 4800-058 Guimarães, Portugal
4
Faculty of Architecture and the Built Environment, Delft University of Technology, 2628 Delft, The Netherlands
5
Centre for Territory, Environment and Construction (CTAC), School of Engineering, University of Minho, 4800-058 Guimarães, Portugal
*
Author to whom correspondence should be addressed.
Buildings 2024, 14(7), 2117; https://doi.org/10.3390/buildings14072117
Submission received: 23 May 2024 / Revised: 24 June 2024 / Accepted: 1 July 2024 / Published: 10 July 2024
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)

Abstract

Accurate knowledge of solar radiation data or its estimation is crucial to maximize the benefits derived from the Sun. In this context, many sectors are re-evaluating their investments and plans to increase profit margins in line with sustainable development based on knowledge and estimation of solar radiation. This scenario has drawn the attention of researchers to the estimation and measurement of solar radiation with a low level of error. Various types of models, such as empirical models, time series, artificial intelligence algorithms and hybrid models, for estimating and measuring solar radiation have been continuously developed in the literature. In general, these models require atmospheric, geographical, climatic and historical solar radiation data from a specific region for accurate estimation. Each analysis model has its advantages and disadvantages when it comes to estimating solar radiation and, depending on the model, the results for one region may be better or worse than for another. Furthermore, it has been observed that an input parameter that significantly improves the model’s performance in one region can make it difficult to succeed in another. The research gaps, challenges and future directions in terms of solar radiation estimation have substantial impacts, but regardless of the model, in situ measurements and commercially available equipment consistently influence solar radiation calculations and, subsequently, simulations or estimates. This article aims to exemplify, through a case study in a multi-family residential building located in Viana do Castelo, a city in the north of Portugal, the difficulties of capturing the spectrum of radiations that make up the total radiation that reaches the measuring equipment or site. Three pieces of equipment are used—a silicon pyranometer, a thermopile pyranometer and a solar meter—on the same day, in the same place, under the same meteorological conditions and with the same measurement method. It is found that the thermopile pyranometer has superior behavior, as it does not oscillate as much with external factors such as the ambient temperature, which influence the other two pieces of equipment. However, due to the different assumptions of the measurement models, the various components of the measurement site make it difficult to obtain the most accurate and reliable results in most studies. Despite the advantages of each model, measurement models have gained prominence in terms of the ease of use and low operating costs rather than the rigor of their results.
Keywords: solar radiation; measurement equipment; Viana do Castelo; environment impact; measurement uncertainty solar radiation; measurement equipment; Viana do Castelo; environment impact; measurement uncertainty

Share and Cite

MDPI and ACS Style

Oliveira, M.; Silva Lopes, H.; Mendonça, P.; Tenpierik, M.; Silva, L.T. Solar Radiation Measurement Tools and Their Impact on In Situ Testing—A Portuguese Case Study. Buildings 2024, 14, 2117. https://doi.org/10.3390/buildings14072117

AMA Style

Oliveira M, Silva Lopes H, Mendonça P, Tenpierik M, Silva LT. Solar Radiation Measurement Tools and Their Impact on In Situ Testing—A Portuguese Case Study. Buildings. 2024; 14(7):2117. https://doi.org/10.3390/buildings14072117

Chicago/Turabian Style

Oliveira, Marta, Hélder Silva Lopes, Paulo Mendonça, Martin Tenpierik, and Lígia Torres Silva. 2024. "Solar Radiation Measurement Tools and Their Impact on In Situ Testing—A Portuguese Case Study" Buildings 14, no. 7: 2117. https://doi.org/10.3390/buildings14072117

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop