1. Introduction
Building energy consumption is a significant contributor to overall energy usage, and enhancing the energy efficiency of building water supply systems presents an opportunity to optimize building energy utilization and decrease building carbon emissions [
1,
2]. Research suggests that the water supply system accounts for 1–4% of a building’s electrical consumption and stands as the largest individual consumer of electricity within an entire city. The specific energy consumption of water supply systems ranges from 1.1 to 1.4 kWh/m
3 in certain Asian cities [
3,
4]. Approximately half of the energy loss in water supply systems is attributed to the pumping system [
5]. Fluctuating water demand throughout the day often causes pumps to operate beyond their intended design parameters. This can trigger turbulent behavior within the pump, ultimately reducing system efficiency. Guide vanes can help enhance the intricate turbulent flow within the pump when it operates under off-design conditions [
6].
The flow through a centrifugal pump with a vaned diffuser introduces complex flow distortion within the diffuser and volute, which is a focal point of pertinent research studies [
7,
8,
9,
10]. Within centrifugal pumps with vaned diffusers, rotating stall in partial load conditions is induced along with pressure fluctuations due to incorrect incidences of the flow discharged by the impeller into the diffuser [
8]. The backflow of fluid into the impeller channel predominantly occurs within the core flow zone and is more pronounced toward the suction side of the impeller blade in partial load conditions. This phenomenon is considered a potential source for the onset of diffuser stalling [
9,
11,
12,
13,
14]. When rotating stall occurs in partial load conditions, the pressure fluctuation at the clearance between the impeller and diffuser displays a distinctive “starfish” shape. The radial force acting on the impeller’s external wall at the liner ring section is comparable to that acting on the impeller blade and outer wall [
12,
15].
The presence of leading edge separations, high-frequency pressure fluctuations, radial forces, backflow, and rotating stall occurrences are common within centrifugal pumps equipped with vaned diffusers [
15,
16,
17]. Hydraulic optimization of vaned diffusers is conducted to mitigate turbulence within pumps using methods such as response surface, multi-objective, and inverse design [
18,
19,
20]. However, the presence of vanes isolating diffuser passages and factors like thick boundary layers at the diffuser inlet or non-uniform velocity distributions, such as those caused by an upstream bend, can lead to deteriorated pressure recovery and an increased risk of separation, potentially resulting in rotating stall occurrences. The presence of rotating stall, backflow, and pressure fluctuations is consistently observed [
21,
22]. The reduced vane height diffuser first utilized in turbomachinery can balance flow non-uniformity among different guide vane passages, creating a more uniform circumferential flow and enhancing pressure recovery performance for centrifugal pumps. This, in turn, reduces alternating stress on the impeller, thereby improving its overall performance [
23]. This highlights the potential benefits of utilizing reduced vane height diffusers in turbomachinery applications. Building upon the findings regarding reduced vane height diffusers in turbomachinery, the authors of the previous work applied reduced vane height diffusers to centrifugal pumps [
24,
25]. This application likely aimed to leverage the benefits observed in turbomachinery systems and adapt them to enhance the performance of centrifugal pumps.
The findings show that the pump with reduced height diffuser vanes obtains higher efficiency compared to vaneless diffusers and a wider high-efficiency operating range compared to vaned diffusers. And the radial force on the impeller is also significantly enhanced. However, the effects of reduced vane height on flow characteristics and total pressure loss remain uncertain. The present work aims to examine the impact of diffuser vane height on the internal flow characteristics in a centrifugal pump. The evaluation commences by assessing the total pressure loss in each flow component. Subsequently, starting from the inlet conditions, the present study investigates how vane height affects the flow characteristics of the overflow components. The dependency of total pressure loss on the flow characteristics is investigated. This study seeks to provide insights into optimizing water supply centrifugal pump performance through diffuser design considerations. The flowchart of the research methodology is described in
Figure 1.
3. Results and Discussion
To assess energy conversion in each component and further investigate the impact of vane height on flow structure,
Figure 9 illustrates the total pressure drop in each component. The non-dimensionalized total pressure drop and work conducted by the impeller is evaluated as follows:
where
represents the total pressure drop, and suffix represents
d (diffuser),
r (rotor)
, and
w (volute);
Pp and
Ps represent the total pressure at the pressure side and the suction side of the component, respectively;
Wsft stands for the shaft power, and
M,
n, and
A2 represent the torque, rotation speed, and area of the impeller outlet, respectively.
The shaft power demonstrates minimal variation at different vane heights across all flow rates, with the maximum difference not exceeding 2.5%. Additionally, the total pressure drop within the impeller also exhibits minimal variation at different vane heights across all flow rates, with the maximum difference not exceeding 1%. This suggests that vane height has little influence on the time-averaged flow field within the impeller. The total pressure drop in the diffuser and volute presents significant differences at different vane heights, especially in overload conditions. The total pressure drop within the diffuser for an h/b less than 1 increases as the flow rate increases. However, at h/b = 1, it decreases to its minimum at the design flow rate and then increases with further increases in flow rate. Besides the total pressure drop decreases with vane height decreases, the difference in the total pressure drop at 0.6 Q/Qdes is smaller compared to other flow rates. At 1.4 Q/Qdes, the difference in the total pressure drop between the guide vanes with h/b = 0.4 and h/b = 1 is approximately 35%.
The total pressure drop in the volute increases as the flow rate increases. At 1.4 Q/Qdes, the difference in the total pressure drop in the volute between the guide vanes with h/b = 0.4 and h/b = 1 is approximately 75%. The total pressure drop in the static component presents hydraulic loss. As the vane height decreases, clearance between the vane and hub exists, leading to varying hydraulic losses in the diffuser due to complex clearance flow. However, it is worth noting that the hydraulic loss in the volute varies significantly due to different diffuser vane heights, indicating that the diffuser vane height has a significant influence on the flow field in the volute.
Figure 10 illustrates the time-averaged pressure at the volute inlet for different vane heights at three flow rates. It is illustrated that the pressure decreases roughly in the direction of rotation away from the tongue and reaches its minimum value at
θr = 330°. At 0.8
Q/
Qdes, the pressure decreases more sharply with
h/
b = 1 than with an
h/
b less than 1, and the variance is reduced with increasing flow rate. It is important to note that with
h/
b = 1, the pressure varies sharply around the tongue and changes to be more smooth when the
h/
b is less than 1. This suggests that the pressure distribution is more uniform with an
h/
b less than 1 than with
h/
b = 1.
The transient radial velocity (
vr) distribution at the volute inlet (the turning surface in
Figure 10) for various time steps and diffuser vane heights is illustrated in
Figure 11, with the white line representing the vane trailing edge. The radial velocity exhibits minimal changes over time, with the most noticeable differences observed near the tongue, as indicated by the square marker in
Figure 11a. However, it is evident that the radial velocity shows significant differences with varying vane heights, particularly in the tongue region, as indicated by the square marker in
Figure 11b. It is demonstrated that when
h/
b = 1, the radial velocity at diffuser passages far away from the tongue shows minimal differences, as illustrated by the dashed square marker. In contrast, the radial velocity at passages near the tongue exhibits significant differences compared to other passages. When the
h/
b is less than 1, the difference between diffuser passages decreases, but the passage upstream of the tongue presents distinct differences compared to others.
To facilitate a more intuitive display and analysis of the variances in the tongue area for various guide vane heights,
Figure 11d–f illustrate the distributions of circumferential (
vc) and radial velocities around the tongue. As previously stated, the variations in velocity over time are significantly smaller compared to the changes observed with blade height. Regardless of the flow rate, the trend in the impact of blade height on the flow at the tongue area remains consistent. As the flow rate increases, both the radial velocity and the circumferential velocity also increase, while the distribution of these velocities remains similar across different flow rates.
As shown in
Figure 11d, a reverse flow region marked by a dashed square and a red arrow exists in front of the tongue for the vaned diffuser with a vane height ratio of 1 (
h/
b = 1), where the radial velocity alternates between positive and negative values. The radial velocities on both the upstream and downstream sides of the reverse flow region are significant. These observations can be attributed to a high-pressure gradient caused by a blocking effect from the tongue, as illustrated in
Figure 10. As the vane height decreases to
h/
b = 0.8, the reverse flow region vanishes and the negative radial velocity region becomes smaller. The direction of the circumferential velocity is deflected toward the hub side, where, similar to a sink, the radial velocity is negative. It is notable that this region is vaned. In the vaneless area, the circumferential velocity exhibits more uniformity, particularly at high flow rates. Additionally, the circumferential and radial velocity in the vaneless region is noticeably larger. When the vane height is further reduced, the negative radial velocity region continuously decreases and may even disappear at lower flow rates. As the flow rate increases, these observations become more prominent. Nevertheless, even with a reduced vane height, the negative radial velocity region persists under overload conditions, although it may occupy a smaller area. Reducing the vane height has been shown to decrease the blocking effect caused by the tongue. It is readily apparent that this reduction in vane height can help alleviate or lessen the interference or obstruction typically caused by the tongue.
Figure 9c demonstrates that the total pressure drop in the volute is significantly influenced by the vane height. The fluid discharged from the diffuser flows over the tongue and then into the volute outlet pipe. The flow field in the tongue region is sensitive to the vane height and notably differs from the region far away from the tongue, as demonstrated in
Figure 11. Considering the radial and circumferential velocity variations with vane height, the flow field in the volute is expected to change significantly with diffuser vane height, leading to different hydraulic losses in the outlet pipe.
Figure 12 displays the streamlines on the midsection for different vane heights at 1.2
Qdes. It is evident that with a vane height ratio of
h/
b = 1, a small clearance between the tongue and the vane trailing edge is formed, where a very high-pressure gradient is observed, as illustrated in
Figure 10, resulting in a small vortex in front of the tongue, as shown in
Figure 12c. The reverse flow and negative radial velocity are induced, as depicted in
Figure 11. Additionally, a large-scale vortex at the outlet pipe, marked with a dashed line arrow, contributes to a squeezing effect on the main flow, while the small-scale vortex enhances this effect, causing deflection of the main flow away from the tongue, as indicated by the blue arrows. For vane height ratios
h/
b less than 1, the pressure gradient is significantly reduced due to the presence of the vaneless region. The small-scale vortex disappears, and the strength and influence area of the large-scale vortex at the outlet pipe decrease. The reverse flow and negative velocity region also decrease, leading to an improvement in the deflection of the main flow. The variation in hydraulic loss with vane height can be attributed to these changes in the flow field.
To assess the variation in hydraulic loss with vane height, an entropy generation analysis method with Computational Fluid Dynamics (CFD) is adopted. Based on research findings [
27,
28], the energy loss can be categorized into viscous loss and turbulent loss. The former is influenced by the time-averaged velocity gradient, while the latter is attributed to fluctuating velocity. Therefore, the energy loss can be quantified using Equations (4)–(6).
where
V stands for velocity.
Given that the second term on the right-hand side of Equation (7) is consistently smaller, particularly in high-Reynolds-number regions, the turbulent energy loss is approximated by the first term. Subsequently, the turbulent loss component can be determined using the kinetic energy dissipation, as expressed in Equation (9).
Figure 13 illustrates the hydraulic loss in the mid-cross-section of the volute for various vane heights at 1.2
Q/
Qdes. It is evident that hydraulic loss primarily occurs at the outlet pipe of the volute. The hydraulic loss is notably higher with a vane height ratio
h/
b of 1.0 compared to
h/
b = 0.6. In the case of
h/
b = 1.0, the hydraulic loss arises in areas where the main flow and interactions with large-scale vortices occur, indicating a significant velocity gradient. As
h/
b = 0.6, the influence area of large-scale vortex decreases, resulting in improved main flow deflection and a reduced fluid flow gradient, ultimately leading to decreased hydraulic loss.
Figure 14 displays the hydraulic loss in three cross-sections of the outlet pipe under varying vane heights and operating conditions. Additionally, streamlines and velocity contour lines are depicted. The visualization indicates that hydraulic loss occurs in regions with a high velocity and more intense contour lines. As the diffuser vane height decreases, the deflection of the main flow becomes more uniform, leading to a reduced velocity and gradient, thereby improving hydraulic loss. In the area marked with a circular line, locally higher hydraulic loss is observed, likely due to being downstream of the vaneless region of the diffuser outlet where the velocity and gradient are relatively high.
4. Conclusions
The current study showcases the impact of vane height on energy loss in the volute of a centrifugal pump. Experimental assessments are conducted to evaluate pressure fluctuations at the tongue and downstream of the tongue. The total pressure loss in various flow components for varying vane heights is analyzed. Subsequently, the flow pattern at the volute inlet and hydraulic loss within the volute are investigated using visualized methods.
Reducing the diffuser vane height leads to a significant decrease in pressure fluctuation intensity and amplitude at the dominant frequency at the tongue and downstream of the tongue. While the diffuser vane height has a minimal impact on the time-averaged shaft power of the centrifugal pump impeller, it has a notable effect on hydraulic loss in the volute. With an increasing flow rate, the reduction in hydraulic loss becomes more pronounced with a decreased vane height.
The reduced height vane leads to a more uniform pressure distribution at the volute inlet along the circumferential direction, eliminating the high-pressure gradient phenomenon at the tongue. This results in the disappearance of recirculation vortices at the tongue observed with traditional guide vanes, along with the elimination of regions of negative radial velocity and reverse flow at the tongue. Consequently, the blocking effect of the vortices at the tongue and outlet pipe of the volute is eliminated, leading to an improvement in the deflection of the main flow in the outlet pipe of the volute and a decrease in the hydraulic loss caused by the relatively high velocity and its gradient induced by flow deflection. This indicates that the reduced height guide vanes can effectively enhance pump efficiency and reduce energy consumption over a broad range of flow rates, playing a positive role in energy saving for building water supply systems.
Although reduced height guide vanes can enhance pump performance, particularly by significantly reducing the energy loss in the volute, the energy loss of the guide vanes themselves is unknown with variations in vane height, and the optimal blade height requires additional investigation, which will be the subject of subsequent research.