1. Introduction
In the coming decades, the major challenge will be accessing fresh drinking water, especially in isolated sites. Social scientists predict that by the year 2025, at least 70% of the Earth’s population is likely to suffer from freshwater scarcity [
1]. Therefore, a solution to prevent a foreseeable crisis is in place. Scientists suggest that the answer to this problem is to make saline water fresh through environmentally friendly mechanisms such as the use of solar power. Using other forms of energy, such as fossil fuels, will worsen the situation owing to global climate change and the heavy use of fresh water to cool the industry [
2]. These novel methods have not yet been put in place as they are under development [
3,
4]. Besides, the solar desalination method is known to produce small amounts of water that may be insufficient to sustain the population. The production of the solar-based system (SBS) has been compared with other sophisticated methods, such as multi-stage flash distillation (MSF), multiple-effect distillation (MED), vapor-compression desalination (VC), and reverse osmosis (RO). Therefore, various scientists have tried to improve the productivity of the solar-based system owing to its cost-effectiveness, timeliness, and friendliness to the environment.
Elmutasim et al. [
5] modified the closed-air open-water (CAOW) humidification and dehumidification (HD) system by incorporating recovery options that depend on heat. The option is made possible through the following two steps: a mixing chamber step and a heat exchanger step. To be able to assess the efficiency of the system, scientists have designed a scale (low, moderate, and high) to measure the effectiveness. Other scholars, such as Tariq et al. [
6], came up with another technique based on innovativeness. In their model, the Maisotsenko cycle-based air saturator was used to increase air humidity. In their new model, Tariq et al. were able to increase the rate at which desalination took place by up to 30%. In the same model, the recovery ratio increased by 46%, while the gain output ratio increased by 11%. The gain output ratio was compared with that of other sophisticated methods that had been used previously.
Further studies on the modification of solar-based desalination were done by Narayan et al. [
7]. They designed and tested different versions of the system to check which modification would do better so that it would be adopted. After their experiments, the authors suggested that the modification that worked well was the solar-based system with a closed-air open-water design (CAOW) [
3,
8].
Moreover, Narayan et al. [
8] introduced another parameter in the solar-based system, which they referred to as the enthalpy pinch. The new variable was designed to balance the system with random numbers in its stages [
9]. On the basis of the results, the authors concluded that pinches increased the effectiveness of the system by 55%.
A couple of authors consolidated the solar-based system with a heat pump to increase its effectiveness in desalination [
10,
11,
12,
13,
14]. In the new system, heat is preserved because heat lost in one stage is used in the next stage. Zhang et al. [
11] investigated the performance of the desalination method coupled with a thermal pump. The authors found that the combined system had an efficiency of 22.26 kg/h. This value was higher than that of the single solar-based system. Similarly, research conducted by another group of researchers, Ayatiet al. [
15], involves coupling the SBS with a heat pump in a random manner, yielding positive results. They employed the HYSYS
® simulator software to conclude that, when the SBS is integrated with the heat pump, the system’s efficiency is enhanced.
Thus, as shown by this brief literature review, a few improvement methods and techniques were adopted by investigators to boost the performance of HD solar desalination systems. In this study, to further develop HD technology, three functioning configurations, together with a controlling algorithm, are designed so that they can be used to show how the efficiency of the SBS can be utilized to improve the overall performance.
2. Materials and Methods
2.1. Different Configurations of the HD System
In the first stages of configuring the SBS for efficiency, the system is checked with an HD system, as shown in
Figure 1. The design was set so that the effectiveness of the freshwater output of the solar multiple condensation evaporation cycle (SMCEC) can be improved [
16,
17]. In the first stages, the system is altered by accommodating the following segments:
Each component had its unique purpose in the system. The system based on the first configuration is shown in
Figure 1. The seawater is preheated in the system, which in turn reduces the overall heat usage in the system, one of the reasons that it is improved. Therefore, the system can be used when the thermal energy can be limited, and thepreheating heat is recovered in other stages of the system. The water heating process follows several processes so that the final product can be collected with the utmost efficiency. The existing and incoming hot and cold air balance the working of the system so that the water heating and the collection process are successful.
The first configuration is characterized by the use of collectors of water and air for the respective heating of water and air simultaneously so that the performance of the system in terms of thermal efficiency can be increased. Moreover, the system operates under reduced pressure to lower the evaporation temperature and thus limit the fouling and corrosion phenomena, which increase with the temperature. In all designs, the fresh water is gathered from the base of the buildup tower, while the saline solution at the base of both the humidifier and dissipation tower will be either reused and joined with the input solution at the section point or dismissed if there should be an occurrence of increment of saltiness rates.
The flexibility of the first configuration of the HD solar desalination system allows us to derive two other settings (operating scenarios) depending on weather conditions and the season of the year:
For days with low sunshine intensity and to avoid condensation of water vapor at the solar air collectors, the second configuration of the solar desalination system, presented in
Figure 2, is recommended. This scenario includes a field of the collectors of solar water with a humidifying module and the distillation module. In this scenario, all the energy needed for evaporation is provided by solar water collectors.
For days with high solar radiation intensity, the first, second, and third configurations presented in
Figure 1,
Figure 2 and
Figure 3, respectively, can be used. In this case, the amount of thermal energy required for evaporation is supplied by the field of solar water collectors (second configuration) or by the field of solar air collectors (third configuration) or by both (first configuration).
2.2. Mathematical Models
2.2.1. Water Solar Collector
The system for the water solar collector represents a multivariate model that consists of multiple inputs and outputs, as shown in
Figure 4. The structure of the collector makes it possible to visualize the variables of the system and map them against time. The external factors that may affect the efficiency of the system are also shown so that the sources of error can be traced. The different variables in the collector are
I (
t),
Tamb (
t),
mw (
t),
Twi (
t), and
Two (
t).
The model is constructed on the basis of the following assumptions:
The following equation illustrates how the thermal balancing of the system is achieved:
where
;
2.2.2. Air Solar Collector
Similarly, the air solar collector represents a multivariate model with multiple inputs and multiple outputs, as shown below in
Figure 5. The display is structured in a way that the different components of the system can be shown as a function of time. The various components are similar to those in the water solar collector.
The system works on the following assumptions:
The exchange coefficient is very high to the extent that the absorber can be assumed to be a flat plate;
The temperatures of the air and the absorber plate are considered equal throughout the absorber;
The air moves with uniform velocity, and it is dependent on only one side x;
There is a difference between the areas of the air, the absorber, and the glass cover.
The model makes use of the following equations:
where
is the coefficient of the net thermal transfer.
2.2.3. The Humidifier
Figure 6 shows the input/output block diagram of the humidifier. The input is made possible at the upper side where saline water is fed. The temperature at the top is denoted by
TL2 (
t), which is interpreted as the humidifying temperature. The saline water leaves the system at the bottom of the model at temperature
TL1 (
t). The movement of the air and the humidity is as shown by the humidifier’s diagram in
Figure 6.
The humidifier operates on the following assumptions:
The system does not transfer heat from one mass to the other;
The flows of the air and water are in a counter-current and a one-dimensional space;
The heat of the water remains invariant throughout the process;
The flow equation shows energy transfer from air to water.
Mathematically, the system works based on the following fluid equations:
2.2.4. Evaporation Tower Modeling
The evaporation tower in the desalination process separates the fresh water from the saline water. During the extraction process, the air is allowed to flow at the lower part of the tower, and its temperatureat that point is
Tgl,ev (
t) and its humidity is
Wg1,ev (
t). Besides, the air has a mass velocity of
mg,ev (
t). When the air exits the tower, its temperature is
Tg2,ev (
t), while its moisture is
Wg2,ev (
t). Moreover, there is hot water that flows from the collector. The water is adjusted to temperature
Tl2,ev (
t).
Figure 7 shows how the tower operates as a multivariate system.
Similarly, the evaporation tower works on the following assumptions:
The system does not transfer heat from one mass to the other;
The flows of the air and water are in a counter-current and a one-dimensional space;
The heat of the water remains invariant throughout the process;
The flow equation shows energy transfer from the air to the water.
The following system of equations represents the flow of fluids that takes place in the evaporation tower.
2.2.5. Condensation Tower Modeling
The other component is the condensation tower. The working of this tower is shown in
Figure 8. The moisturized air coming from the evaporation tower enters the condensation stage at the top with temperature
Tgc2 (
t); the humidity of the air is
Wgc2(t), and it flows with a flow rate of
mgt (
t). As it moves through the condenser, the air is momentarily cooled, and upon reaching the exit point, the air is at temperature
Te1 (
t), while its flow rate per mass changes to
De (
t).
The condensation tower operates on the following assumptions:
Air–condensate interphase
and
2.3. Regulation Algorithm
Asthe SBS is dependent on the availability of sunshine, the system is further modified to enable it to serve its purpose even in periods when the sunlight is not sufficient. The modification will increase the reliability of the system as it will be able to preserve energy and operate normally during times when there is no sunshine. The improvement makes use of numerical mathematical models that are established to control the working of the model. The effectiveness of developing a mathematical model wastested, and it was shown that an algorithm could be used to improve the reliability of the model.
The model is designed to change the features of the water and air in the different chambers. By controlling the temperature of the water and air that enter and leave the towers, it is possible to recycle hot water and keep the temperature of the air and the water below that in the system, which preserves the overall energy usage. The result is that energy will be conserved. During times when there is no sunshine, the system can still work because there is some conserved energy. However, the system should have an alternative way because conserved energy cannot work for a prolonged time [
19].
The energy evolution and preservation process in the system is shown by the following equation:
where
at the water solar collector outlet.
We set
. The adopted formula serves the purpose of forcing
to follow the set-point
for satisfying the desired dynamic. We consider the dynamics of a closed loop given by the following linear equation:
Using Equations (17) and (18), we deduce the following command equation:
3. Results and Discussion
The HD solar desalination system is modified in three ways to test the effectiveness of each modification, as well as testing which modification best suits the required purpose of the system. To check the policy, we ran simulations with a C++ program. The results describe the variation in the production of fresh water under each modification. The working of the system and the simulated results for the three modifications are shown in
Figure 9. The graph illustrates that the maximum mass of fresh water presented by any of the three modifications is about 18 kg/day. Specifically, the highest mass is received from the third modification. The order of preference of the three modifications is from the third to the first. The second modification is more efficient than the first modification, whereas the third is more efficient than the first andthesecond. Therefore, the third modification was chosen to be the most efficient and reliable modification.
Given the complexity of the process and the practical impossibility of varying one parameter, the system requires several modifications. Furthermore, setting the others because of meteorological fluctuations and having an optimal flow rate of water as it enters the evaporation tower with the highest possible temperature and better air flow rate is required for leveraging the production. Besides, the third configuration is essential if a law that controls the variation in the solar flux (I) and that controls the flow rate of the water into the water solar collector (mw) is put in place. Finally, the amount of water to be recycled (mrecy) should always respect the optimal operating temperature (Tl1,ev) as well as the water flow rate (ml,ev) in the evaporation tower. The regulation consists of setting the set-points of the temperature of the water at the solar collector outlet (Twset), the temperature of the water at the evaporation tower (Tl1set), and the water flow rates (mw and mrecy), as follows:
Set-point of the outlet of the temperature of water:
Set-point of the inlet of the temperature of water in the evaporation tower:
To adjust the high water temperature set-points, the rate of flow of the water ranges between 0.01 and 0.5 kg/s.
Figure 10 and
Figure 11 describe the variation in the rate of flow of water in the water solar collector and the quantity of recycled water for a given solar radiation model, respectively. The amount of recycled water satisfies the desired condition imposed on the water flow rate in the evaporation tower,
mrecy. For a water flow rate higher than 0.2 kg/s in the water solar collector, the amount of water to be recycled is equal to zero. When the water flow rate drops below 0.2 kg/s,
mrecy takes a nonzero value to compensate for the decrease in the water flow rate.
Figure 12 illustrates the behavior of the water temperature at the outlet of the collector and that at the inlet of the evaporation tower.
Two follows its desired value carefully. Likewise,
Tl1,ev retains the assigned value.
The estimated amount of fresh water produced during eight hours of operation using the algorithm established for the regulation of the third configuration of the HD solar desalination system is shown in
Figure 13. The same figure shows the amount of fresh water obtained under the same working conditions, but without regulation. The difference between the two estimated quantities to be collected is apparent, suchthat the gain derived using regulation is around 33%. Concerning the daily fresh water production amounts for the managed system when compared with other HD solar systems [
20,
21,
22], their volume run from 6 to 15.2 L/day, is a promising rate.
4. Cost Analysis
Production is designed to ensure that maximum profits are realized, while at the same time, costs are minimized. Besides, different approaches appear to be desirable, forcing one to conduct a cost analysis and to evaluate the weaknesses and strengths associated with each alternative. Given the costs and benefits of different production components, it is possible to create different production paths and then assess their profitability. The option with the lowest cost becomes desirable as it may be used to achieve maximum profit.
Table 1 shows the components of production investment and their respective costs.
The total cost of the system is arrived at by totaling the fabrication costs, repair and maintenance costs, and the cost of operation. The investment’s main aim is to recover the total costs. Initially, the amount laid as the investment cost is 10,775 €. Besides, the system is estimated to have a lifetime of 20 years, which must be taken into consideration while arriving at the most effective alternative.
Assumptions:
Analysis:
The total litres of water that will be produced = production rate per day × total period of production × lifetime = .
The total cost of production (water per litre) = = .
The daily cost of production (water in litres per day) = cost of production of water per litre × productivity = .
The cost of maintenance = 0.01 €/day.
Net income = cost of production of water − the cost of maintenance = 1.62 − 0.01 = 1.61 €.
Period for effective payback = .
As the system will take approximately 18 years, which is less than its lifetime, to repay itself, the investment is worth the cost.
5. Conclusions
To make the solar desalination system more effective, scientists have made several changes to the solar desalination model. The novelty of the current study is to obtain a higher production rate of daily fresh water in the HD solar desalination system through developing and simulating three design configurations of the process and integrating into the optimal configuration a regulation algorithm to further optimize its freshwater production. The results obtained indicate that the maximum freshwater output of about 18 kg/day is obtained with the third configuration, and this value is also increased by nearly 33% with the implementation of the proposed regulation algorithm.The atomization of such a type of solar desalination system, together with the development of a regulating algorithm for the removal of minerals and salts in the system, is an extension of the current study.
Author Contributions
Conceptualization, K.Z.; completed literature review, K.Z. and K.A.A.; investigation, K.Z.; formal analysis, K.Z. and K.A.A.; software, K.Z. and K.A.A.; cost analysis, K.A.A.; writing—review and editing, K.Z. and K.A.A. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Acknowledgments
The authors wish to express their deep gratitude to Habib Ben Bacha, Kamel Zarzoum, and Engineer Sami Mejbri for their help in comprehensively realizing this research and discussing the obtained results.
Conflicts of Interest
The authors declare no conflict of interest.
List of Symbols
A | air–water exchanger area in the condensation tower (m2) |
a | air–water exchanger area (m2) |
b | width of air solar collector |
C | specific heat (J/(kg·K)) |
De | water mass velocity in the condensation tower (kg/(m2·s)) |
h | heat transfer coefficient (J/(kg·K)) |
hg | air heat transfer coefficient at the air–water interface(W/(m2·K)) |
he | water heat transfer coefficient at the air–water interface(W/(m2·K)) |
l | widthof water solar collector (m) |
L | length of air solar collector (m) |
I | solar flux (W/m2) |
K | thermal conductivity (W/(m·K)) |
Km | water vapor mass transfer coefficient at the air–water interface (kg/(m2·s)) |
M | mass (kg) |
m | mass flow rate (kg/s) |
mc | fresh water production (kg/s) |
mgt | total mass velocity of moist air in the condenser (kg/(m2·s)) |
S | absorber surface (m2) |
T | temperature (K) |
Ti | temperature at the air–water interface (K) |
U | overall heat transfer coefficient in the condensation tower (W/ (m2·K)) |
Uloss | overall energy loss from the absorber to outside (W/ (m2·K)) |
W | air humidity (kg water/kg dry air) |
Wi | saturation humidity (kg water/kg dry air) |
z | coordinate in the flow direction (m) |
x | coordinate in the flow direction (m) |
Greek | |
α | absorptance of the collector absorber surface |
λo | latent heat of water evaporation (J/kg) |
τ | transmittance |
Subscripts | |
1 | tower bottom |
2 | tower top |
a | air |
amb | ambient |
c | condensation tower |
con | convection |
e | cooling water |
v | glass cover |
ev | evaporation tower |
g | moist air |
h | humidifier |
loss | loss to ambient |
pl | absorber plate |
rad | radiation |
References
- Li, C.; Goswami, Y.; Stefanakos, E. Solar assisted sea water desalination: A review. Renew. Sustain. Energy Rev. 2013, 19, 136–163. [Google Scholar] [CrossRef]
- Dehghani, S.; Date, A.; Akbarzadeh, A. An experimental study of brine recirculation in humidification-dehumidification desalination of seawater. Case Stud. Therm. Eng. 2019, 14, 100463. [Google Scholar] [CrossRef]
- Giwa, A.; Akther, N.; Al Housani, A.; Haris, S.; Hasan, S.W. Recent advances in humidification dehumidification (HDH) desalination processes: Improved designs and productivity. Renew. Sustain. Energy Rev. 2016, 57, 929–944. [Google Scholar] [CrossRef]
- Srithar, K.; Rajaseenivasan, T. Recent freshwater augmentation techniques in solar still and HDH desalination—A review. Renew. Sustain. Energy Rev. 2018, 82, 629–644. [Google Scholar] [CrossRef]
- Elmutasim, S.M.; Ahmed, M.A.; Antar, M.A.; Gandhidasan, P.; Zubair, S.M. Design strategiesof conventional and modified closed-air open-water humidification dehumidificationsystems. Desalination 2018, 435, 114–127. [Google Scholar] [CrossRef]
- Tariq, R.; Sheikh, N.; Xamán, J.; Bassam, A. An innovative air saturator for humidification-dehumidification desalination application. Appl. Energy 2018, 228, 789–807. [Google Scholar] [CrossRef]
- Narayan, G.P.; Sharqawy, M.H.; Summers, E.K.; Lienhard, J.H.; Zubair, S.M.; Antar, M.A. The potential of solar-driven humidification–dehumidification desalinationfor small-scale decentralized water production. Renew. Sustain. Energy Rev. 2010, 14, 1187–1201. [Google Scholar] [CrossRef]
- Narayan, G.P.; Chehayeb, K.M.; McGovern, R.K.; Thiel, G.P.; Zubair, S.M.; Lienhard, J.H. Thermodynamic balancing of the humidification dehumidification desalinationsystem by mass extraction and injection. Int. J. Heat Mass Transf. 2013, 57, 756–770. [Google Scholar] [CrossRef] [Green Version]
- Narayan, G.P.; John, M.G.S.; Zubair, S.M.; Lienhard, J.H. Thermal design of the humidificationdehumidification desalination system: An experimental investigation. Int. J. Heat Mass Transf. 2013, 58, 740–748. [Google Scholar] [CrossRef]
- Shafii, M.B.; Jafargholi, H.; Faegh, M. Experimental investigation of heat recovery ina humidification dehumidification desalination system via a heat pump. Desalination 2018, 437, 81–88. [Google Scholar] [CrossRef]
- Zhang, Y.; Zhu, C.G.; Zhang, H.; Zheng, W.D.; You, S.J.; Zhen, Y.H. Experimental studyof a humidification dehumidification desalination system with heat pump unit. Desalination 2018, 442, 108–117. [Google Scholar] [CrossRef]
- He, W.F.; Han, D.; Ji, C. Investigation on humidification dehumidification desalinationsystem coupled with heat pump. Desalination 2018, 436, 152–160. [Google Scholar] [CrossRef]
- Lawal, D.U.; Antar, M.; Khalifa, A.; Zubair, S.; Al-Sulaiman, F. Humidification dehumidificationdesalination system operated by a heat pump. Energy Convers. Manag. 2018, 161, 128–140. [Google Scholar] [CrossRef]
- Lawal, D.U.; Zubair, S.M.; Antar, M.A. Exergo-economic analysis of humidification-dehumidification (HDH) desalination systems driven by heat pump (HP). Desalination 2018, 443, 11–25. [Google Scholar] [CrossRef]
- Ayati, E.; Rahimi-Ahar, Z.; Hatamipour, M.S.; Ghalavand, Y. Water productivity enhancement in variable pressure humidification dehumidification (HDH) desalination systems using heat pump. Appl. Therm. Eng. 2019, 160, 114. [Google Scholar] [CrossRef]
- Zhani, K.; Ben Bacha, H. Experimental investigation of a new solar desalination prototype using the humidification dehumidification principle. Renew. Energy 2010, 35, 2610–2617. [Google Scholar] [CrossRef]
- Zhani, K.; Ben Bacha, H. Modeling and simulation of a new design of the SMCEC desalination unit using solar energy. Desalin. Water Treat. 2010, 21, 346–356. [Google Scholar] [CrossRef]
- Zhani, K.; Ben Bacha, H.; Damak, T. Modeling and experimental validation of a humidification–dehumidification desalination unit solar part. Energy 2011, 36, 3159–3169. [Google Scholar] [CrossRef]
- Damak, T. Modeling, Estimation and Control of Biotechnological Processes of the Hyperbolic Type. Ph.D. Thesis, Paul Sabatier University, Toulouse, France, 1994. [Google Scholar]
- Farida, M.; Al-hajaj, A.W. Solar desalination with a humidification-dehumidification cycle. Desalination 1996, 106, 427–429. [Google Scholar] [CrossRef]
- El-Shazly, A.; Al-Zahrani, A.; Al-Hamed, Y.; Nosier, S. Effect of fixed bed characteristics on the performance of pulsed water flow humidification-dehumidification solar desalination unit. Desalin. Water Treat. 2013, 51, 863–871. [Google Scholar] [CrossRef]
- Hamed, M.H.; Kabeel, A.; Omara, Z.; Sharshir, S. Mathematical and experimental investigation of a solar humidification–dehumidification desalination unit. Desalination 2015, 358, 9–17. [Google Scholar] [CrossRef]
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).