Next Article in Journal
Improving Software Defect Prediction in Noisy Imbalanced Datasets
Previous Article in Journal
A Denoising Method for Multi-Noise on Steel Surface Detection
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect

1
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing 102206, China
2
Department of Computer Application Technology, Huazhong Electric Power Union Staff University, Wuhan 430014, China
*
Author to whom correspondence should be addressed.
Appl. Sci. 2023, 13(18), 10472; https://doi.org/10.3390/app131810472
Submission received: 14 August 2023 / Revised: 7 September 2023 / Accepted: 11 September 2023 / Published: 19 September 2023

Abstract

For investigating the relationship between the surface corona discharge of a DC wire and other influencing factors, a hybrid numerical model based on a fluid-chemical reaction was proposed to simulate the discharge process at the tip defect of the wire. Under different defect geometries and gas pressures achieved via simulation, the microscopic process of the reaction and movement of electrons and heavy particles during a positive corona discharge was studied, and characteristic parameters such as corona inception voltage and discharge current were analyzed. Furthermore, through the corona cage test, for a specific electrode configuration, corona inception voltages under different pressures were compared and verified, which showed that the model was reasonable. The results showed that the maximum electron density of the streamer head was about 1 × 1020 m−3, the rise time of the pulse current was about 10 ns, and the decay time was about 300–500 ns. The corona inception voltage decreased with an increase in the tip height and decreases in the tip curvature radius, conductor radius, and background air pressure; the amplitude of the pulse current increased with increases in the wire radius and curvature radius of the defect tip and decreases in tip height and background air pressure. The experimental results are consistent with the simulation results, which verifies the reasonability of the model.
Keywords: DC overhead line; fluid-chemical model; corona discharge; tip defect DC overhead line; fluid-chemical model; corona discharge; tip defect

Share and Cite

MDPI and ACS Style

Wang, S.; Mai, J.; Wang, L. A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect. Appl. Sci. 2023, 13, 10472. https://doi.org/10.3390/app131810472

AMA Style

Wang S, Mai J, Wang L. A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect. Applied Sciences. 2023; 13(18):10472. https://doi.org/10.3390/app131810472

Chicago/Turabian Style

Wang, Shenghui, Jiamin Mai, and Lihong Wang. 2023. "A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect" Applied Sciences 13, no. 18: 10472. https://doi.org/10.3390/app131810472

APA Style

Wang, S., Mai, J., & Wang, L. (2023). A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor’s Tip Defect. Applied Sciences, 13(18), 10472. https://doi.org/10.3390/app131810472

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop