Next Article in Journal
Non-Linear Creep-Relaxation Constitutive Damage Model for Aging Concrete
Previous Article in Journal
AdvancingTire Safety: Explainable Artificial Intelligence-Powered Foreign Object Defect Detection with Xception Networks and Grad-CAM Interpretation
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Research on a Neutron Detector with a Boron-Lined Multilayer Converter

School of Physics and Electronic Engineering, Sichan University of Science and Engineering, Zigong 643000, China
*
Author to whom correspondence should be addressed.
Appl. Sci. 2024, 14(10), 4269; https://doi.org/10.3390/app14104269
Submission received: 24 April 2024 / Revised: 11 May 2024 / Accepted: 14 May 2024 / Published: 17 May 2024
(This article belongs to the Section Applied Physics General)

Abstract

3He is a splendid neutron detection material due to its high neutron reaction cross section, gaseous state, and nonelectronegative and nonpoisonous nature. With the worldwide problem of the “3He supply crisis” arising, boron-lined gaseous neutron detectors are being widely used in neutron detection to replace 3He neutron detectors. In this work, to reduce the scattering neutron background coming from the substrate of a boron-lined neutron detector in the application of neutron scattering, a new design of the boron-lined gaseous neutron detector composed of a boron-lined multichip converter and a multiwire proportional chamber was proposed. The electron drift efficiency matrix simulated by Garfield++ (Version 2023.4) and the values and positions of electron energy deposition simulated by Geant4 were obtained. The α, 7Li, and total charged particle energy deposition spectra were acquired via coupling calculations of the electron drift efficiency matrix and the values and positions of electron energy deposition, and the width of the slit was selected as 3 mm. The boron-lined multilayer converter neutron detector (BMCND) was tested using a 241Am–239Pu mixture α source, and the total count rate of α charged particles was measured as 599.5 s−1, which is 89% of the theoretical α particle emission rate of 672.9 s−1. The drift voltage experiments showed that 1200 V is enough to acquire a relatively ideal count, and a 2500 V drift voltage was confirmed, considering the higher count and instrument safety. We also performed the neutron detection experiments using a photo-neutron source, and a characteristic spectrum shape of “two stairs” was measured. When borated polyethylene was used to shield the BMCND, the detected total count decreased while keeping the characteristic spectrum shape, demonstrating that the BMCND was equipped with the ability to detect neurons, indicating that BMCNDs have the potential to be an outstanding 3He alternative neutron detector.
Keywords: boron-lined neutron detector; BMCND; electron drift efficiency; energy deposition spectrum; neutron detection efficiency boron-lined neutron detector; BMCND; electron drift efficiency; energy deposition spectrum; neutron detection efficiency

Share and Cite

MDPI and ACS Style

Deng, C.; Hu, Q.; Li, P.; Wang, Q.; Xie, B.; Yang, J.; Tuo, X. Research on a Neutron Detector with a Boron-Lined Multilayer Converter. Appl. Sci. 2024, 14, 4269. https://doi.org/10.3390/app14104269

AMA Style

Deng C, Hu Q, Li P, Wang Q, Xie B, Yang J, Tuo X. Research on a Neutron Detector with a Boron-Lined Multilayer Converter. Applied Sciences. 2024; 14(10):4269. https://doi.org/10.3390/app14104269

Chicago/Turabian Style

Deng, Chao, Qin Hu, Pengcheng Li, Qibiao Wang, Bo Xie, Jianbo Yang, and Xianguo Tuo. 2024. "Research on a Neutron Detector with a Boron-Lined Multilayer Converter" Applied Sciences 14, no. 10: 4269. https://doi.org/10.3390/app14104269

APA Style

Deng, C., Hu, Q., Li, P., Wang, Q., Xie, B., Yang, J., & Tuo, X. (2024). Research on a Neutron Detector with a Boron-Lined Multilayer Converter. Applied Sciences, 14(10), 4269. https://doi.org/10.3390/app14104269

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop