Next Article in Journal
Evaluation of Chemical Compounds in Local Garlic Genotypes from Southwestern Romania
Previous Article in Journal
An Audio Watermarking Algorithm Based on Adversarial Perturbation
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Communication

Study on Thermal Reflection Characteristics of Composite Inorganic Coatings

Tianjin Chengjian University, Tianjin 300192, China
*
Author to whom correspondence should be addressed.
Appl. Sci. 2024, 14(16), 6898; https://doi.org/10.3390/app14166898
Submission received: 4 July 2024 / Revised: 1 August 2024 / Accepted: 3 August 2024 / Published: 7 August 2024
(This article belongs to the Section Applied Thermal Engineering)

Abstract

:
This study examined the thermal reflective properties of composite inorganic coatings applied to various wall types. It evaluated the influence of these coatings on the thermal insulation and reflectivity of the walls. The findings indicate that coating application markedly enhances a wall’s thermal insulation capabilities and increases its heat flux reflection ratio. These results offer crucial theoretical backing and practical guidance for the future use of coating technologies in construction. By refining the coating formulations and application processes, the thermal insulation properties of walls can be further enhanced, thus making a significant contribution to building energy efficiency and environmental protection. Consequently, this research provides essential references and insights for advancing coating technology in the construction industry.

1. Introduction

Energy scarcity and environmental deterioration pose significant challenges to humanity, necessitating a focus on energy conservation and emission reduction in architecture. This study explores thermal reflective insulation coatings for buildings, which involve placing low thermal conductivity air between layers of highly reflective aluminum films to form a composite material with superior insulation properties. These materials, particularly focused on barrier, reflective, and radiation insulation, are widely used in building walls and other applications [1,2,3,4,5,6,7,8,9,10,11,12,13,14,15]. Organic thermal insulation materials, such as polyurethane foam, expanded polystyrene, and phenolic foam, are recognized for their light weight and ease of processing [16,17,18,19,20,21,22,23]. Conversely, inorganic thermal insulation materials are increasingly valued for their excellent thermal stability and eco-friendly characteristics [24,25,26]. Previous research has shown that different substrates and novel nano-composite inorganic materials vary in terms of their effects on sunlight reflection. ElȦbieta Malewska et al. performed extensive tests on new heat-reflecting coatings, assessing their suitability as substrates with anti-corrosion, alkaline resistance, and self-quenching properties at temperatures below 200 °C [27]. Marwan M. developed a novel composite material, CLC brick, for use in building wall design, examining its potential to reduce energy costs [28]. Lin et al. created terbium-doped cerium oxide nanocomposites with a near-infrared solar reflectivity of 85.54% using a green synthesis method, ball milling, and high-temperature calcination [29]. Luo et al. devised a method to prepare radiation-cooled coatings that enhance the sunlight scattering efficiency by randomly distributing Y2O3 nanoparticles in PDMS [30]. Yuan et al. explored the effects of applying DHR and RR materials to building facades on the outdoor thermal environment [31]. Currently, other research on new inorganic coatings primarily focuses on aspects such as corrosion resistance, alkaline resistance, and preparation technology.
This study investigates the reflection characteristics of thermal reflective coatings on different walls, systematically assessing the impact of the wall composition, light source irradiation angle, light source irradiation duration, and other factors on the efficacy of the thermal reflection. The aim is to thoroughly explore the mechanisms of thermal reflection.

2. Experimental Section

2.1. Control of Powder

The powder is a proprietary blend internally developed. Latex paint, as the binder used in the test, is applied to the wall before the coating material, which can improve the adhesion of the paint. The powder is mainly composed of calcium silicate, calcium carbonate, calcium hydroxide, and binders. These components are combined in specific proportions to form a coating mixture. As shown in Figure 1a, the mixing process begins with adding water at a speed of 1000 rpm, and the mass ratio of dry powder to water (M (dry powder)/M (water)) is about 1:0.7 until a uniform paste is obtained, as shown in Figure 1b. After the mixture is left to stand for 15 min, the slurry is stirred again for 5 min. The amount of water added can be slightly adjusted according to the actual viscosity of the mixture.
In this study, three different wall materials commonly used in construction were selected for experimentation: block brick walls (hereafter referred to as block walls), clay brick walls (brick walls), and adobe brick walls (earth walls), as shown in Figure 2a–c. Investigating the effects of thermal reflective coatings on these walls has significant representational value.

2.2. Coating Preparation

Typically, civil buildings utilize three kinds of walls: block walls, brick walls, and earth walls. These walls differ in terms of their thermal conductivity, which significantly impacts their insulation performance. This study assessed the thermal reflection capabilities of these walls by applying thermal reflective coatings, with the detailed configurations displayed in Figure 2(a1–c3). The dimensions of each experimental wall were 0.6 m in length, 0.25 m in width, and 0.6 m in height. After the walls dried completely, a layer of heat-reflective coating was applied to each. In the test, we controlled the thickness of the coating, and the thickness measured by the tool was 2 mm. Testing was conducted once the coatings had fully dried.

2.3. Test Method Characterization

This study was conducted in the temperate monsoon climate of Tianjin, characterized by cold winters and hot summers, focusing on the insulation effects of coatings during winter. The experimental setup included an infrared radiometer (model HL-131, the manufacturer is Shenzhen Lianhuicheng Technology Co., Ltd., Shenzhen, Guangdong, China), a reflective indoor heater (model RSN22-S07J, rated at 700 W, 220 V, the manufacturer is Changhong Meiling Technology Co., Ltd., Zhongshan, Guangdong, China), and a thermocouple thermometer (model RE-Y2101B, the manufacturer is Kipsen Technology Industrial Co., Ltd., Guangzhou, Guangdong, China), as detailed in Figure 3b. The thermocouple thermometer recorded the temperatures on both sides of the wall, using indoor reflective heaters as the heat source. The infrared radiometer measured the infrared heat flux, which spans a wavelength range of 0.76–1000 μm.
Heat flux is defined as the heat received or reflected per unit area of the wall. It is influenced by the wall’s thickness, the temperature differential across the wall, and the wall material’s thermal conductivity. This metric is crucial for evaluating both the heat dissipation performance and the heat loss of materials. Currently, the evaluation of thermal reflective coatings in buildings primarily focuses on hemispherical emissivity and solar reflectivity. This experiment primarily examined how the wall material, the angle of heat source irradiation, and the duration of irradiation affect the insulation properties of the coatings. The photothermal and thermal reflection performance of the coating were assessed by measuring the temperature difference between the exterior wall and the room temperature, as well as the heat flux reflectance before and after coating application.
The test was structured into two primary sections: measuring the temperature and heat flux of three different walls, and monitoring the temperature data in the Earth Survey Building classroom. Prior to applying the coating, temperature sensors were installed at two equidistant points along a diagonal on the rear of each wall segment to ensure accurate data collection. These sensors were linked to thermocouple thermometers, as depicted in Figure 3. Initially, the angle (θ) between the heat source’s central axis and the vertical plane of the wall was set for various measuring points on the three walls, as illustrated in Figure 4a,b. It was necessary to log the temperature of the “bare wall” every 30 min, collecting 15 datasets, and of the “bare wall + heat source” every 30 s for a duration of 10 min. Subsequently, θ was adjusted from 10 degrees to 80 degrees in 10-degree increments to assess the changes in temperature and heat flux. Following this, the temperatures and reflected heat fluxes for the “wall after a coat of paint” were recorded every 30 min, with 15 data sets collected, and for the “wall + heat source after a coat of paint” every 30 s for 10 min. θ was similarly adjusted from 10 degrees to 80 degrees in 10-degree steps, and the measurements continued for three days to evaluate the stability.
To capture accurate and reliable data, measurements were taken from four points on each wall, with two points on each side. These points were located at the two-thirds positions along the diagonal of the wall, as shown in Figure 4c. At the start of the experiment, the following were recorded: indoor and outdoor temperatures, indoor and outdoor humidity, radiator temperature, the temperature 60 cm from the radiator, radiator heat flux, and heat flux 60 cm from the radiator. The heat source was consistently positioned 60 cm from the center of the wall. Additionally, the temperature fluctuations in the classroom were monitored before and after painting over a continuous three-day period.

3. Results and Discussion

3.1. Temperature Stability

3.1.1. Temperature Stability Test of Three Bare Walls under the Heat Source

As illustrated in Figure 5a,b, a temperature differential exists between the front and back of the wall when exposed to a heat source, confirming the wall’s inherent thermal insulation capability. For instance, with θ set at 10°, the temperature difference between the front and back of the block wall can reach 7 °C.

3.1.2. Temperature Stability Test of Bare and Coated Walls

Figure 6a details the temperature measurements for the block wall, both bare and after applying a layer of paint. Initially, the room temperature was recorded at 16.2 °C and 20.4 °C. The graph shows that one minute of heat exposure resulted in a temperature of 18.2 °C behind the bare wall, and 18.1 °C after ten minutes. The temperature at the measurement point behind the wall was consistently higher than the room temperature. With a layer of paint, the temperature behind the wall was 17.6 °C after both one minute and ten minutes of heat exposure. The temperature difference between the measurement point and the room temperature increased by −4.7 °C after painting, demonstrating the paint’s effective insulation.
Figure 6b presents the temperature measurements for the brick wall, bare and painted. The room temperatures were 16.2 °C and 20.4 °C, respectively. Initially, the temperature behind the bare wall was 17.8 °C after one minute of exposure and 18.2 °C after ten minutes, exceeding the room temperature. After applying the paint, the temperature behind the wall remained at 18.3 °C after both one minute and ten minutes of exposure. The temperature difference between the measurement point and the room temperature increased by −4.1 °C after painting, indicating a favorable insulation effect.
As depicted in Figure 6c, the temperature measurements for the bare earth wall and the painted brick wall showed initial room temperatures of 16.2 °C and 20.4 °C. One minute of exposure resulted in a temperature of 17.7 °C behind the bare wall, and 17.4 °C after ten minutes, slightly above the room temperature. Following painting, the temperature behind the wall was 19.6 °C after one minute and 19.7 °C after ten minutes of exposure, with a temperature increase of −1.9 °C compared to the room temperature, suggesting effective insulation. These findings preliminarily indicate that the insulation effectiveness is related to the wall material.

3.1.3. The Temperature of the Bare Wall and the Wall after Coating Changes

As shown in Figure 7, temperature measurements were conducted on both bare and painted block walls, with the room temperatures recorded at 16.2 °C and 20.4 °C, respectively. The data indicated that the temperatures behind the wall, both before and after painting, were similar, resulting in almost identical curves. In the temperature range of 10° to 50°, the temperature behind the bare wall was consistently above the room temperature when exposed to the heat source. However, after applying a coat of paint, the temperature behind the wall decreased by approximately 3°, with the most significant reduction observed at 60°. For the bare brick wall and painted brick wall, with room temperatures of 16.2 °C and 20.6 °C, respectively, the temperatures behind the bare wall exceeded the room temperature from 10° to 80° when exposed to the heat source. After painting, the temperature behind the wall dropped, with the largest decrease at about 20°, showing a reduction of 6.6 °C. Similarly, for the bare earth wall and painted earth wall, with room temperatures of 17.1 °C and 20.4 °C, respectively, the temperatures behind the bare wall were higher than the room temperature from 10° to 80° under heat source exposure. After painting, the temperature behind the wall fell by approximately 0.7 °C. These observations suggest that the optimal angle for applying the coating, which achieves the best insulation effect, varies among the three types of walls, indicating that the insulation effectiveness is influenced by both the wall material and the angle of the light source.

3.1.4. The Temperature Stability of the Wall after One Coat of Paint

Figure 8a illustrates the temperature measurements behind the painted block wall over three days, with room temperatures of 20.4 °C, 20.6 °C, and 20.4 °C and corresponding humidity levels of 56%, 49%, and 51%. The temperature behind the wall remained consistently about 3.0℃ lower than the room temperature. In Figure 8b, for the coated brick wall, with room temperatures over three days of 20.4 °C, 20.6 °C, and 20.4 °C and humidity levels of 56%, 49%, and 51%, the temperature behind the wall stabilized at roughly 2.4 °C below the room temperature after painting. Figure 8c shows the temperature measurements behind the coated earth wall, with room temperatures of 20.4 °C, 21.3 °C, and 20.7 °C and humidity levels of 84%, 78%, and 78%, respectively. Here, the temperature behind the wall stabilized at about 0.9 °C below the room temperature after the paint application. The preliminary conclusions suggest that the insulation effect of the coating on the block wall is superior to that on the brick wall, and the insulation effects across all three wall types appear to be relatively stable over time.

3.1.5. Temperature Stability Test before and after Coating

As shown in Figure 9, before and after painting, the indoor temperature increased, the insulation effect gradually became stable, and the indoor temperature difference reached about 4.5 °C.

3.2. Thermal Reflection Characteristic

3.2.1. Comparison of Heat Flux Reflected by Three Walls

As depicted in Figure 10, applying a layer of paint to the block wall results in an increase in the heat flux reflection by about 0.15 mw/cm2. Similarly, painting the brick wall increases its heat flux reflection by approximately 0.15 mw/cm2, while for the earth wall, this increase is about 0.06 mw/cm2. It is evident that the application of a thermal insulation coating significantly enhances the heat flux reflection of these walls.

3.2.2. The Heat Flux Reflected by the Wall after a Coat of Paint Changes

Figure 11 illustrates the test outcomes for the block wall, where the external conditions significantly influenced the heat flux measurements at 70° and 80°, leading to the omission of related data and images. The experimental records show that when the indoor reflective heater is positioned at an angle of about 10°, the heat flux reaching the wall is 0.959 mw/cm2. The highest heat flux reflection from the block wall, occurring at angles between 10° and 20°, is 0.211 mw/cm2, giving a reflection ratio of 0.22. For the brick wall, the external conditions also heavily impacted the measurements at 70° and 80°, and thus, these data points are excluded. When the heater is at an angle of about 10°, the incoming heat flux is 1.395 mw/cm2. The peak reflection, observed between 10° and 20°, is 0.258 mw/cm2, resulting in a reflection ratio of 0.18. Regarding the earth wall, the external test conditions at 70° and 80° similarly necessitated the omission of data and visuals. The heat flux reaching the wall with the heater at approximately 10° is 1.199 mw/cm2. The maximum reflection, noted between 10° and 20°, is 0.26 mw/cm2, with a reflection ratio of 0.22.
In summary, after the application of the thermal insulation coating, the heat flux reflection ratios for the three walls are relatively similar, demonstrating the pronounced effect of the coating on the heat flux reflection. The highest reflection occurs between angles of 10° and 20° for all the wall types.

3.2.3. The Change in Heat Flux Reflected for 3 Consecutive Days

As illustrated in Figure 12, there is minimal variation in the heat flux reflection by the three walls over three consecutive days. According to Table 1, the heat flux reflection ratio of the earth wall remains consistent over time, whereas the ratios for the block and brick walls show some variation, suggesting that the coating on the earth wall achieves a stable insulation effect more rapidly.

4. Conclusions

A systematic study was undertaken to examine the thermal reflection characteristics of walls with different base materials. The application of thermal reflective coatings substantially increased both the insulation temperature differential and the heat flux reflectivity of the walls. Composite inorganic coatings were found to effectively diminish both the heat absorption and the reflective radiation of the walls, thereby reducing the indoor energy consumption. In a comparative experiment conducted within a room, the indoor temperature difference was observed to reach approximately 4.5 °C before and after the application of the coating. The heat-reflective coatings demonstrated a pronounced effect on the reflective heat flux, particularly when the θ ranged from 10° to 20°, during which the heat flux reflected by the wall was at its maximum. The heat flux reflectivity among the three types of walls showed no significant differences. This coating has proven suitable for various regions and settings, ensuring its effectiveness for long-term use. Compared to other inorganic coatings mentioned in this article, the materials used in this research demonstrate excellent applicability to various areas and provide a significant insulation effect when applied to different walls.

Author Contributions

Conceptualization, J.S.; methodology, J.S. and M.W.; validation, M.W. and P.W.; resources, J.S.; data curation, M.W. and G.L.; writing—original draft, M.W. and Y.L.; writing—review and editing, M.W. and M.Y. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Ganzhou Yaoyue Construction Engineering Co., Ltd. [Approval No. KHX2023-055].

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors on request.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Zhou, Z.; Zhang, Z.; Huang, J.; Wang, Y. Water-based intumescent fire resistance coating containing organic-modified glass fiber for steel structure. J. Clean. Prod. 2024, 442, 140897. [Google Scholar] [CrossRef]
  2. Zhao, L.; Yao, S.; Nan, Y.; Qin, L.; Yi, S. Research Status and Development Trend of Sintered Solid Waste-based Wall Insulation Materials. J. Phys. Conf. Ser. 2023, 2510, 012019. [Google Scholar] [CrossRef]
  3. Zhang, Y.; Yin, S.; Mu, H.; Zhang, X.; Tan, Q.; Shao, B. Study on the performance of lightweight roadway wall thermal insulation coating containing EP-GHB mixed ceramsite. Build. Simul. 2024, 17, 785–798. [Google Scholar] [CrossRef]
  4. Zhang, Q.; Wang, Q.; Li, Y.; Li, Z.; Liu, S. Effects and Mechanisms of Ultralow Concentrations of Different Types of Graphene Oxide Flakes on Fire Resistance of Water-Based Intumescent Coatings. Coatings 2024, 14, 162. [Google Scholar] [CrossRef]
  5. Zhang, L.; Zhang, A.-N.; He, S.-M.; Zheng, G.-Q.; Zeng, F.-R.; Wang, Y.-Z.; Liu, B.-W.; Zhao, H.-B. Biomimetic Nanoporous Transparent Universal Fire-Resistant Coatings. ACS Appl. Mater. Interfaces 2024, 16, 19519–19528. [Google Scholar] [CrossRef]
  6. Tsapko, Y.; Kasianchuk, I.; Likhnyovskyi, R.; Tsapko, A.; Kovalenko, V.; Nizhnyk, V.; Bedratiuk, O.; Sukhanevych, M. Determining thermal and physical characteristics of wood polymer material for pipeline thermal insulation. East.-Eur. J. Enterp. Technol. 2023, 125, 63–72. [Google Scholar]
  7. Tokunaga, J.; Koide, H.; Mogami, K.; Hikosaka, T. Comparative studies on the aging of thermally upgraded paper insulation in palm fatty acid ester, mineral oil, and natural ester. IEEE Trans. Dielectr. Electr. Insul. 2016, 23, 258–265. [Google Scholar] [CrossRef]
  8. Seok, P.H.; Prakash, D. Development of a resilient cable joint for the insulation system of oil tanks. J. Mech. Sci. Technol. 2012, 26, 3617–3624. [Google Scholar] [CrossRef]
  9. Porzuczek, J. Comparative Study on Selected Insulating Materials for Industrial Piping. Materials 2024, 17, 1601. [Google Scholar] [CrossRef]
  10. Lipkovich, I.; Tokareva, A.; Gracheva, N.; Panchenko, S.; Ukrainians, M. Evaluation of thermal insulation of pipelines in the overhead method of laying in the climatic conditions of the South of Russia. IOP Conf. Ser. Earth Environ. Sci. 2023, 1212, 012053. [Google Scholar] [CrossRef]
  11. Guan, J.; Wei, Z.; Yan, L.; Tang, X.; Xu, Z. Construction of organophosphate-functionalized α-zirconium phosphate towards fire-resistant, weather-resistant and antibacterial reinforcement of transparent fireproof coatings applied on wood substrates. Prog. Org. Coat. 2024, 190, 108397. [Google Scholar] [CrossRef]
  12. Fang, Y.; Ma, Z.; Wei, D.; Yu, Y.; Liu, L.; Shi, Y.; Gao, J.; Tang, L.C.; Huang, G.; Song, P. Engineering Sulfur-containing Polymeric Fire-Retardant Coatings for Fire-Safe Rigid Polyurethane Foam. Macromol. Rapid Commun. 2024, 45, 2400068. [Google Scholar] [CrossRef] [PubMed]
  13. De Mets, T.; Prignon, M.; Knapen, E. Lime-hemp as Wall Insulation-Hygrothermal Performance Analysis by Validated Simulations. J. Phys. Conf. Ser. 2023, 2654, 012075. [Google Scholar] [CrossRef]
  14. Capolupo, F.; D’alessandro, C.; Strazzullo, P.; Russo, R.; Musto, M. Design and thermal test of high-vacuum insulator for heat delivery pipes. J. Phys. Conf. Ser. 2024, 2685, 012057. [Google Scholar] [CrossRef]
  15. Alsaffar, A.K.K.; Alquzweeni, S.S.; Al-Ameer, L.R.; Ali, A.H.; Mohamed, A.; Aldaihani, H.M.; Reham, A.; Al-Ansari, N.; Al-Hashimi, O.; Shubbar, A.; et al. Development of eco-friendly wall insulation layer utilising the wastes of the packing industry. Heliyon 2023, 9, e21799. [Google Scholar] [CrossRef] [PubMed]
  16. Zhuang, X.W.; Li, S.H.; Ma, Y.F.; Zhang, W.; Xu, Y.Z.; Wang, C.P.; Chu, F.X. Preparation and performance research on phenolic insulation foam used low-temperature foaming technology. Adv. Mater. Res. 2011, 250, 450–454. [Google Scholar] [CrossRef]
  17. Yu, Z.; Liang, D. Study on preparation of insulation and flame retardant building materials with inorganic compound phenolic foam. Chem. Eng. Trans. 2016, 55, 325–330. [Google Scholar]
  18. Yao, J.W.; Hou, Z.M.; Yao, Y.S. Application of phenolic foam plate in the exterior wall thermal insulation. Appl. Mech. Mater. 2012, 174, 1363–1366. [Google Scholar] [CrossRef]
  19. Tingley, D.D.; Hathway, A.; Davison, B.; Allwood, D. The environmental impact of phenolic foam insulation boards. Proc. Inst. Civ. Eng.-Constr. Mater. 2017, 170, 91–103. [Google Scholar] [CrossRef]
  20. Kowalska, B.Z.; Szajding, A.; Zakrzewska, P.; Kuźnia, M.; Stanik, R.; Gude, M. Disposal of rigid polyurethane foam with fly ash as a method to obtain sustainable thermal insulation material. Constr. Build. Mater. 2024, 417, 135329. [Google Scholar] [CrossRef]
  21. Kabundu, E.; Mbanga, S.; Botha, B.; Ayesu-Koranteng, E. Relative Comparison of Benefits of Floor Slab Insulation Methods, Using Polyiso and Extruded Polystyrene Materials in South Africa, Subject to the New National Building Energy Efficiency Standards. Energies 2024, 17, 539. [Google Scholar] [CrossRef]
  22. Jensen, N.F.; Rode, C.; Andersen, B.; Bjarløv, S.P.; Møller, E.B. Internal insulation of solid masonry walls–field experiment with Phenolic foam and lime-cork based insulating plaster. E3S Web Conf. 2020, 172, 01003. [Google Scholar] [CrossRef]
  23. Benchouia, H.E.; Boussehel, H.; Guerira, B.; Sedira, L.; Tedeschi, C.; Cucchi, M. An experimental evaluation of a hybrid bio-composite based on date palm petiole fibers, expanded polystyrene waste, and gypsum plaster as a sustainable insulating building material. Constr. Build. Mater. 2024, 422, 135735. [Google Scholar] [CrossRef]
  24. Shen, L.; Tan, H.; Ye, Y.; He, W. Using Fumed silica to develop thermal insulation cement for medium–low temperature geothermal wells. Materials 2022, 15, 5087. [Google Scholar] [CrossRef] [PubMed]
  25. Li, Q.; Chen, H.; Li, Z. Preparation and properties of silicate inorganic external wall insulation materials based on heat storage. Therm. Sci. 2023, 27 Pt A, 941–948. [Google Scholar] [CrossRef]
  26. Jian, J.; Luo, W.; Liu, H.; Jiang, Y. Numerical Simulation Verification of the Application of Inorganic Thermal Insulation Materials to the Surrounding Rock of Roadways. J. Phys. Conf. Ser. 2023, 2566, 01209. [Google Scholar] [CrossRef]
  27. Malewska, E.; Prociak, A.; Vevere, L.; Vanags, E.; Zemła, M.; Uram, K.; Kirpluks, M.; Cabulis, U.; Bryk, M. New Thermo-Reflective Coatings for Applications as a Layer of Heat Insulating Materials. Materials 2022, 15, 5642. [Google Scholar] [CrossRef] [PubMed]
  28. Marwan, M. The effect of wall material on energy cost reduction in building. Case Stud. Therm. Eng. 2020, 17, 100573. [Google Scholar] [CrossRef]
  29. Lin, Y.; Liu, Y.; Jia, G.; Wang, C.; Li, Y.; Wu, L. High heat-reflective and superhydrophobicity properties functional fabrics. Ceram. Int. 2024, 50, 13582–13590. [Google Scholar] [CrossRef]
  30. Luo, C.-L.; Zheng, L.-X.; Jiao, J.-Y.; Yan, W.-G.; Zhao, J.; Jia, G.-Z.; Liu, Z.-F.; Tian, J.-G. Enhanced passive radiative cooling coating with Y2O3 for thermal management of building. Opt. Mater. 2023, 138, 113710. [Google Scholar] [CrossRef]
  31. Yuan, J.; Shimazaki, Y.; Zhang, R.; Masuko, S.; Cao, S.-J. Can retro-reflective materials replace diffuse highly reflective materials for urban buildings’ wall to improve outdoor thermal comfort? Heliyon 2023, 9, e14872. [Google Scholar] [CrossRef] [PubMed]
Figure 1. (a) Powder paint in dry state. (b) Well-stirred paint.
Figure 1. (a) Powder paint in dry state. (b) Well-stirred paint.
Applsci 14 06898 g001
Figure 2. (a1) Block wall masonry stage. (a2) Block wall plastering stage. (a3) Block wall painting stage. (b1) Brick wall masonry stage. (b2) Brick wall plastering stage. (b3) Brick wall paint stage. (c1) Earth wall masonry stage. (c2) Earth wall plastering stage. (c3) Soil wall painting stage.
Figure 2. (a1) Block wall masonry stage. (a2) Block wall plastering stage. (a3) Block wall painting stage. (b1) Brick wall masonry stage. (b2) Brick wall plastering stage. (b3) Brick wall paint stage. (c1) Earth wall masonry stage. (c2) Earth wall plastering stage. (c3) Soil wall painting stage.
Applsci 14 06898 g002
Figure 3. (a) Gouging and embedding temperature sensors. (b) Connecting the thermocouple thermometer. (c) The temperature sensor is buried on the left view of the wall and the right view of the wall.
Figure 3. (a) Gouging and embedding temperature sensors. (b) Connecting the thermocouple thermometer. (c) The temperature sensor is buried on the left view of the wall and the right view of the wall.
Applsci 14 06898 g003
Figure 4. (a) Heat flux test to the wall. (b) Heat flux test reflected by wall. (c) Schematic diagram of temperature and heat flux test system.
Figure 4. (a) Heat flux test to the wall. (b) Heat flux test reflected by wall. (c) Schematic diagram of temperature and heat flux test system.
Applsci 14 06898 g004
Figure 5. (a) Schematic diagram of the temperature stability test. (b) Schematic diagram of the temperature stability test in front of and behind three bare walls at θ 10°.
Figure 5. (a) Schematic diagram of the temperature stability test. (b) Schematic diagram of the temperature stability test in front of and behind three bare walls at θ 10°.
Applsci 14 06898 g005
Figure 6. (a) Temperature change of the block wall before and after coating under the heat source. (b) Temperature change of the brick wall before and after coating under the heat source. (c) Temperature change of the earth wall before and after coating under the heat source (θ is 10°).
Figure 6. (a) Temperature change of the block wall before and after coating under the heat source. (b) Temperature change of the brick wall before and after coating under the heat source. (c) Temperature change of the earth wall before and after coating under the heat source (θ is 10°).
Applsci 14 06898 g006
Figure 7. The temperature of the three bare walls and the wall after one coat of paint changes with θ when the wall is illuminated by the heat source (θ is 10°~80°, step size is 10°).
Figure 7. The temperature of the three bare walls and the wall after one coat of paint changes with θ when the wall is illuminated by the heat source (θ is 10°~80°, step size is 10°).
Applsci 14 06898 g007
Figure 8. (a) Temperature change of the block wall after coating under an indoor reflective heater for 3 consecutive days. (b) Temperature change of the brick wall after coating under an indoor reflective heater for 3 consecutive days. (c) Temperature change of the earth wall after coating under an indoor reflective heater for 3 consecutive days (θ is 10°).
Figure 8. (a) Temperature change of the block wall after coating under an indoor reflective heater for 3 consecutive days. (b) Temperature change of the brick wall after coating under an indoor reflective heater for 3 consecutive days. (c) Temperature change of the earth wall after coating under an indoor reflective heater for 3 consecutive days (θ is 10°).
Applsci 14 06898 g008
Figure 9. Six consecutive days of temperature changes before and after painting in the Geodesy Building classroom.
Figure 9. Six consecutive days of temperature changes before and after painting in the Geodesy Building classroom.
Applsci 14 06898 g009
Figure 10. (a) Schematic diagram of the heat flux test. (b) The heat flux reflected by a bare wall and a coated block wall under the heat source. (c) The heat flux reflected by a bare wall and a coated brick wall under the heat source. (d) The heat flux reflected by the heat source on bare and coated earth walls (θ is 10°~60°).
Figure 10. (a) Schematic diagram of the heat flux test. (b) The heat flux reflected by a bare wall and a coated block wall under the heat source. (c) The heat flux reflected by a bare wall and a coated brick wall under the heat source. (d) The heat flux reflected by the heat source on bare and coated earth walls (θ is 10°~60°).
Applsci 14 06898 g010
Figure 11. Three walls after one coat of paint and wall reflection heat flux comparison of indoor reflective heater (θ is 10°~60°, step size is 10°).
Figure 11. Three walls after one coat of paint and wall reflection heat flux comparison of indoor reflective heater (θ is 10°~60°, step size is 10°).
Applsci 14 06898 g011
Figure 12. (a) Heat flux reflected by the heat source for 3 consecutive days by the block wall with one coat of paint. (b) Heat flux reflected by the brick wall with one coat of paint for 3 consecutive days by the heat source. (c) Heat flux reflected by the earth wall with one coat of paint for 3 consecutive days by the heat source (θ is 10°).
Figure 12. (a) Heat flux reflected by the heat source for 3 consecutive days by the block wall with one coat of paint. (b) Heat flux reflected by the brick wall with one coat of paint for 3 consecutive days by the heat source. (c) Heat flux reflected by the earth wall with one coat of paint for 3 consecutive days by the heat source (θ is 10°).
Applsci 14 06898 g012
Table 1. Heat flux reflectance ratio of three walls for three consecutive days after one coat of paint (θ is 10°).
Table 1. Heat flux reflectance ratio of three walls for three consecutive days after one coat of paint (θ is 10°).
Block WallBrick WallEarth Wall
The first day0.220.180.22
The second day0.260.220.21
The third day0.260.260.21
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Shang, J.; Wang, M.; Wang, P.; Li, G.; Yang, M.; Li, Y. Study on Thermal Reflection Characteristics of Composite Inorganic Coatings. Appl. Sci. 2024, 14, 6898. https://doi.org/10.3390/app14166898

AMA Style

Shang J, Wang M, Wang P, Li G, Yang M, Li Y. Study on Thermal Reflection Characteristics of Composite Inorganic Coatings. Applied Sciences. 2024; 14(16):6898. https://doi.org/10.3390/app14166898

Chicago/Turabian Style

Shang, Jun, Mingyang Wang, Pei Wang, Guoliang Li, Mengyao Yang, and Yang Li. 2024. "Study on Thermal Reflection Characteristics of Composite Inorganic Coatings" Applied Sciences 14, no. 16: 6898. https://doi.org/10.3390/app14166898

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics