Experimental Study on an Optimized-Section Precast Slab with Structural Aesthetics
Abstract
:1. Introduction
2. Test Program
2.1. Specimen Details
2.2. Test Setup and Measurement
3. Test Results and Discussion
3.1. Load Deflection Responses and Failure Patterns
3.2. Strain Measured from the Longitudinal and Shear Reinforcement
3.3. Comparison of the Test and Analysis Results
4. Conclusions
- The OPS has an optimized cross-section that can effectively resist both positive and negative moments with the flange positioned on the top in the center and on the bottom at the end portion of the PC unit and is a member that has been developed to introduce a curved shape into the variable cross-section and thus, to highlight the structural aesthetics.
- According to the test results, no damage was observed at the interface between the PC unit and the topping concrete, and the composite specimens exhibited full-composite behavior.
- In the PC unit shear specimens, critical cracks progressed near the variable cross-section and shear cracks were formed at an angle that was higher than that of the typical horizontal members. On the other hand, in the composite PC shear specimens, the flexural performance was improved due to the topping concrete and shear dominant failure modes were more apparent as the influence of the variable cross-section was relatively small compared with that of the PC unit specimens.
- The current design codes were found to provide a very accurate evaluation of the flexural capacities of the PC unit and the composite PC members and, in particular, could also properly evaluate the negative moment resistance capacity at the continuous ends. However, it should be mentioned that to secure the required negative moment resistance capacity, the location of the variable cross-section and the cutting point of the tensile reinforcement that was placed at the continuous ends should be properly determined considering the applied loads and the flexural moment distribution.
- It is expected that the OPS can be utilized to long span structures, such as underground parking lots and logistics warehouses which require high load carrying capacities with economic feasibility and structural aesthetics.
Author Contributions
Acknowledgments
Conflicts of Interest
References
- Elliot, K.S.; Colin, K.J. Multi-Storey Precast Concrete Framed Structures, 2nd ed.; Wiley Blackwell: Hoboken, NJ, USA, 2013. [Google Scholar]
- Lee, D.H.; Park, M.K.; Oh, J.Y.; Kim, K.S.; Im, J.H.; Seo, S.Y. Web-Shear Capacity of Prestressed Hollow-Core Slab Unit with Consideration on the Minimum Shear Reinforcement Requirement. Comput. Concr. 2014, 14, 211–231. [Google Scholar] [CrossRef]
- Ghosh, S.K. Shear Reinforcement Requirements for Precast Prestressed Double-Tee Member. Struct. J. 1987, 84, 287–292. [Google Scholar] [CrossRef]
- Industry Hand Book Committee. PCI Design Handbook, 7th ed.; Precast/Prestressed Concrete Institute: Chicago, IL, USA, 2010. [Google Scholar]
- Anderson, A.R. Composite Designs in Precast and Cast-in-Place Concrete. Progress. Archit. 1960, 41, 172–179. [Google Scholar]
- Ju, Y.K.; Kim, S.D. Structural Behavior of Alternative Low Floor Height System using Structural “Tee,” Half Precast Concrete, and Horizontal Stud. Can. J. Civ. Eng. 2005, 32, 329–338. [Google Scholar] [CrossRef]
- Yang, L. Design of Prestressed Hollow-Core Slabs with Reference to Web-Shear Failure. J. Struct. Eng. 1994, 120, 2675–2696. [Google Scholar] [CrossRef]
- Park, R.; Gamble, W.L. Reinforced Concrete Slab, 2nd ed.; Wiley: Hoboken, NJ, USA, 2000. [Google Scholar]
- Palmer, K.D.; Schultz, A.E. Factors Affecting Web-shear Capacity of Deep Hollow-Core Units. PCI J. 2010, 55, 123–146. [Google Scholar] [CrossRef]
- Palmer, K.D.; Schultz, A.E. Experimental Investigation of the Web-Shear Strength of Deep Hollow-Core Units. PCI J. 2011, 56, 83–104. [Google Scholar] [CrossRef]
- Arockiasamy, M.; Badve, A.P.; Rao, B.V.; Reddy, D.V. Fatigue Strength of Joints in a Precast Prestressed Concrete Double Tee Bridge. PCI J. 1991, 36, 84–99. [Google Scholar] [CrossRef]
- Naito, C.J.; Cao, L.; Peter, W. Precast Concrete Double-tee Connections, Part I: Tension Behavior. PCI J. 2009, 54, 49–66. [Google Scholar] [CrossRef]
- Mejia-McMaster, J.C.; Park, R. Test on special reinforcement for the end support of hollow-core slabs. PCI J. 1994, 39, 90–105. [Google Scholar] [CrossRef]
- Rosenthal, I. Full scale test of continuous prestressed hollow-core slab. PCI J. 1978, 23, 74–81. [Google Scholar] [CrossRef]
- Tan, K.H.; Zheng, L.X.; Paramasivam, P. Designing hollow-core slabs for continuity. PCI J. 1996, 41, 82–91. [Google Scholar] [CrossRef]
- ACI Committee 318. Building Code Requirements for Reinforced Concrete and Commentary; (ACI 318-14); American Concrete Institute: Farmington Hills, MI, USA, 2014. [Google Scholar]
- Korea Concrete Institute. Concrete Design Code; Kimoondang Publishing Company: Seoul, Korea, 2012. [Google Scholar]
- Collins, M.P.; Mitchell, D. Prestressed Concrete Structures; Prentice-Hall: Upper Saddle River, NJ, USA, 1991. [Google Scholar]
- MacGregor, J.G.; Wight, J.K. Reinforced Concrete Mechanics and Design, 4th ed.; Prentice-Hall: Upper Saddle River, NJ, USA, 2006. [Google Scholar]
- Bentz, E.C. Sectional Analysis of Reinforced Concrete Members. Ph.D. Dissertation, University of Toronto, Toronto, ON, Canada, 2000. [Google Scholar]
- Vecchio, F.J.; Collins, M.P. Modified Compression-Field Theory for Reinforced Concrete Elements Subjected to Shear. ACI J. 1986, 83, 219–231. [Google Scholar] [CrossRef]
- Vecchio, F.J.; Collins, M.P. Predicting the Response of Reinforced Concrete Beams Subjected to Shear Using Modified Compression Field Theory. ACI Struct. J. 1988, 85, 258–268. [Google Scholar] [CrossRef]
- Bentz, E.C.; Vecchio, F.J.; Collins, M.P. Simplified Modified Compression Field Theory for Calculating Shear Strength of Reinforced Concrete Elements. ACI Mater. J. 2006, 103, 614–624. [Google Scholar] [CrossRef]
Specimen | Compressive Strength of the Concrete, | Longitudinal Reinforcement in the Top | Longitudinal Reinforcement in the Bottom | Shear Reinforcement | ||||
---|---|---|---|---|---|---|---|---|
PC | Topping | Rebar | Tendon | Rebar | Tendon | |||
UF | 47 | - | - | (110) | (397) | (280) | ||
USa and USb | 47 | - | - | (110) | (794) | (280) | ||
CF | 47 | 34 | (143) | (110) | (397) | (280) | ||
CSa ans CSb | 47 | 34 | (143) | (110) | (970) | (280) | ||
NFW and NFE * | 47 | 34 | Center (143) | End (1575) | (110) | (397) | (280) |
Diameter of Rebar | Yield Strength, | Yield Strength, |
---|---|---|
D10 | 505 | 628 |
D13 | 472 | 590 |
D16 | 462 | 575 |
D19 | 473 | 636 |
D25 | 529 | 661 |
Type | Code Equation * |
---|---|
Flexural strength | |
Shear strength | (contribution of concrete) (contribution of stirrup) |
Specimen (Flexure) | (kN·m) | (kN·m) | Specimen (Shear) | (kN) | (kN) | ||
---|---|---|---|---|---|---|---|
LSA * | Code | R2K * | Code | ||||
UF | 198 | 198 | 190 | USa | 165 | 137 | 189 |
CF | 277 | 305 | 275 | USb | 150 | 137 | 189 |
NFW | 94 | 94 | 92 | CSa | 229 | 216 | 237 |
NFE | 403 | 409 | 398 | CSb | 242 | 216 | 231 |
© 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Ju, H.; Han, S.-J.; Choi, I.S.; Choi, S.; Park, M.-K.; Kim, K.S. Experimental Study on an Optimized-Section Precast Slab with Structural Aesthetics. Appl. Sci. 2018, 8, 1234. https://doi.org/10.3390/app8081234
Ju H, Han S-J, Choi IS, Choi S, Park M-K, Kim KS. Experimental Study on an Optimized-Section Precast Slab with Structural Aesthetics. Applied Sciences. 2018; 8(8):1234. https://doi.org/10.3390/app8081234
Chicago/Turabian StyleJu, Hyunjin, Sun-Jin Han, Il Sup Choi, Seokdong Choi, Min-Kook Park, and Kang Su Kim. 2018. "Experimental Study on an Optimized-Section Precast Slab with Structural Aesthetics" Applied Sciences 8, no. 8: 1234. https://doi.org/10.3390/app8081234
APA StyleJu, H., Han, S.-J., Choi, I. S., Choi, S., Park, M.-K., & Kim, K. S. (2018). Experimental Study on an Optimized-Section Precast Slab with Structural Aesthetics. Applied Sciences, 8(8), 1234. https://doi.org/10.3390/app8081234