1. Introduction
When conventional endocardial measurements of ejection fraction (EF) are used to assess left ventricular (LV) function, the increases in wall thickness or decreases in diameters might mask the existence of a significant impairment in systolic performance [
1,
2]. Experimental [
3,
4] and clinical studies using strain analysis [
5] have demonstrated that less fiber shortening is required to achieve a comparable EF in a thick-walled compared to a thin-walled LV. Similarly, despite comparable shortening and wall thickness, a smaller LV will have a greater EF than a larger ventricle [
1]. Therefore, in clinical practice, it is essential to have access to metrics that, unlike the assessment of EF, can identify meaningful myocardial disease in individuals with a hypertrophic phenotype [
6].
One of the most intriguing parameters in this context is the ratio of stroke volume to myocardial volume, which determines the myocardial contraction fraction (MCF). It is a measure of how much the myocardium contracts during systole (as measured by stroke volume [SV]) in comparison to its ability to contract (as measured by myocardial volume) [
7,
8].
There is ample evidence that the MCF can discriminate between pathological and normal hypertrophy [
1,
9,
10] and identify individuals with heart failure with preserved EF due to amyloidosis from those with increased wall thickness due to other conditions [
11,
12]. Prognostically, the MCF outperforms the EF when measured by cardiac magnetic resonance in patients with cardiac amyloidosis (CA) or hypertrophic cardiomyopathy (HCM) [
9,
13]. However, one notable disadvantage of MCF measurement is that it is not a standard component of transthoracic echocardiography since the LV mass quantification using the standard linear diameter measures is frequently inaccurate in hearts with regional heterogeneity [
14]. Furthermore, the systematic underestimation of the LV volumes assessment by 2-dimensional echocardiography (2DE) compared to cardiac magnetic resonance further complicates the routine use of MCF [
15].
Yet, many of these issues are now solved by automated three-dimensional echocardiography (3DE) [
16]. Recently, a further improvement in 3DE technology provided a new algorithm for LV analysis, which is based on the principles of machine learning dynamic heart model ([DHM], Philips Healthcare, Andover, MA, USA) using a training set of over a thousand studies [
17], allowing for a feasible, fast, accurate, and reproducible automated quantification of LV mass [
18] and volumes [
19] in one single output. Therefore, applying machine learning techniques to 3DE has great potential to enhance physician familiarity with the MCF metric in clinical practice. However, despite the high accuracy, a DHM measure of MCF has not been described yet.
To address this, we describe the measure of MCF by DHM and compare it in normal subjects in patients with isolated hypertension, CA, and HCM.
2. Materials and Methods
2.1. Study Subjects
The study population comprised patients aged ≥18 who underwent standard transthoracic Doppler echocardiography for any indication from 14 September 2020 to 9 November 2021 at Modena University Hospital’s echocardiography laboratory. Criteria for enrollment included age ≥18 years, complete resting 2D and 3D echocardiographic assessment, and EF ≥ 50%. We excluded patients with unsatisfactory images—the margins were not seen well and thus deemed untraceable, patients on dialysis or end-stage liver failure, since large fluid shifts in these patients may cause significant extemporaneous differences in LA and LV measurements, patients with moderate or severe valvular heart disease, pregnant women and those who are in the six months following childbirth, and patients with morbid obesity or leanness (BMI ≥ 30 kg/m2, BMI < 18.5 kg/m2, respectively).
Then, we identify four groups of subjects (
Figure 1): (1) healthy adults (absence of diabetes, hypertension, previous or current heart disease, cardiac implantable electronic devices, stroke, COPD, venous thromboembolism, cancer, previous or current systemic diseases that may have an impact on the cardiovascular system, drug therapy or other treatments with cardiovascular effects, normal cardiovascular physical examination, normal ECG at rest) without clinical indication on DHM, (2) isolated hypertension (same requirements as for normal group, but with only a history of systemic arterial hypertension), (3) patients with HCM, diagnosed according to current guidelines [
20,
21] (4) patients with CA, diagnosed according to the position statement of the European Society of Cardiology Working Group on Myocardial and Pericardial Diseases [
22].
Age, sex, height, weight, body surface area (BSA), cardiac rhythm, clinical indications, and history of cardiovascular diseases were recorded at the time of the echocardiography. The study protocol followed the ethical guidelines of the 1975 Declaration of Helsinki and was approved by the local ethic committee (Protocol Code: 234-2021, date of approval: 11 May 2021).
2.2. Echocardiographic Data
A complete 2D and 3D transthoracic echocardiographic examination was performed, according to current guidelines [
23,
24], using a commercial ultrasound system (EPIQ CVx, Philips Healthcare) equipped with an X5-1 transducer. We used a single-beat acquisition mode and multiple cardiac cycles (3–5 beats) in patients with atrial fibrillation. Analysis of DHM methodology was described in detail in our recent publication [
25]. Briefly, after setting gain, time-gain compensation, and depth on 2D images, a single-beat acquisition mode from the apical four-chamber view was used to acquire 3D wide-angle datasets. By changing sector width and image depth, the 3D frame rate was optimized. All the acquisitions were performed by operators fully trained in echocardiography with long-standing experience with the 3D technique and trained on echocardiographic datasets focusing on what constitutes adequate automated analysis. The novel vendor software simultaneously detects LV and left atrial (LA) endocardial surfaces using an adaptive analytics algorithm, which uses knowledge-based identification to orient and locate cardiac chambers and patient-specific adaptation of endocardial borders from which LV and LA volumes are derived directly without geometrical assumptions.
Using the automated DHM program, which automatically detects LV endo- and epicardial borders at the end-diastole, 3D-LV mass was analyzed, enabling direct LV mass thickness. Although it is possible to correct the LV and LA endocardial–epicardial borders at the end-diastole and and-systole, manual border adjustments were performed when deemed indicated by the operator. We considered the following DHM measures: LV end-diastolic volume indexed to BSA (EDVi), LV end-systolic volume indexed to BSA (ESVi), EF, SV, LA maximum volume indexed to BSA (LAVi max), LA minimum volume indexed to BSA (LAVi min), LA ejection fraction (LAEF), automatically calculated as LA maximum volume-LA minimum volume/LA maximum volume), LV mass, LV mass indexed to BSA, LV mass: LV end-diastolic volume ratio (LVM/LVEDV). We considered the MCF as an additional measure of the LV function as LV stroke volume/LV myocardial volume × 100. The myocardial volume was assessed by directly measuring the LV mass between the epicardium and endocardium by DHM and calculated by dividing the LV mass by 1.05 (the density of myocardial tissue). When correctly performed, the calculation of LV myocardial volume is the same whether performed during systole or diastole because myocardial tissue, being not compressible, does not change during contraction [
26]. All 3D echocardiography images were analyzed online using the larger default boundary detection sliders (end-diastolic position = 60/60; end-systolic position = 30/30). This setting defines diastolic and systolic contour positions within the myocardial wall ranging from 0 to 100, 0 being the most inner endocardial contour toward the LV cavity and 100 being the most outer endocardial contour towards the myocardial wall. To our knowledge, there are no specific recommendations about this feature, and the decision is left to the single image laboratory. We deliberately decided to apply these fixed threshold borders settings because they were the ones used in previous validation studies, and they are closer to the settings of CMR [
27]. All measurements were entered into an electronic database during the echocardiographic examination. No modification from the original database was applied, and no 3D measurement was made offline. Hence, the study consisted of a retrospective analysis of data prospectively included in the electronic echocardiographic database.
3. Statistical Analysis
Data are shown as counts and percentages or median and interquartile range (IQR). Categorical variables were compared with the Chi-square test (or Fisher’s exact test if appropriate). For continuous variables, a comparison was made with the Mann–Whitney U test. Linear regression analysis was used to compare MCF and LVEF. The quality standards for correlations were defined as: very good: 0.8 < R2 < 1.0; good: 0.6 < R2 < 0.8; moderate: 0.4 < R2 < 0.6; or poor: R2 < 0.4. The discriminatory performance of the MCF for each study subgroup was explored using receiver-operating characteristic (ROC) curves and the area under the curve (AUC) analysis; the Youden index was used to determine the best cut-off values. A p-value < 0.05 was considered to be statistically significant in all the analyses. Analyses were performed using SPSS® version 26 (IBM Corp, Armonk, NY, USA).
4. Results
The original dataset consisted of 1349 consecutive patients. Among them, we identified 54 healthy adults, 87 patients affected by isolated hypertension, 36 by HCM, and 10 by CA. Median age was 49 (37–69) years, 61 (52–75) years, 63 (56–69) years, and 81 (79–82) years, respectively. Females accounted for 51.9% of healthy adults, 55.2% of isolated hypertension, 32.4% of HCM, and 10% of CA. Of note, 10.8% of HCM patients and 50% of CA patients had a history of atrial fibrillation. Most healthy adults (90.7%) and isolated hypertension (87.4%) showed an MCF ≥ 50%, while this finding was observed only in 41.7% of HCM patients and 10% of CA patients. Patients with MCF ≥ 50% were younger as compared with patients with MCF < 50% (57 (46–70) vs. 72 (59–81) years,
p < 0.001), they were more frequently female (53.9% vs. 26.1%;
p < 0.001) and less frequently had a history of coronary artery disease (0.7% vs. 8.7%,
p = 0.014). A detailed description of the patient’s demographic and clinical characteristics according to their baseline MCF value is shown in
Table 1.
Echocardiographic parameters are shown in
Table 2. Interestingly, LVEDVi and LVESVi were not different between patients with MCF ≥ 50% and <50% (72.3 (62.9–81.8) vs. 68.2 (59.7–82.1) mL/m
2;
p = 0.469 and 28.6 (23.0–35.8) vs. 32.0 (24.6–38.7) mL/m
2;
p = 0.154, respectively). On the other hand, patients with MCF ≥ 50% showed a significantly lower LAVi max (34.4 (28.4–42.7) vs. 54.0 (41.3–65.3) mL/m
2;
p < 0.001) and LAVi min (12.7 (9.4–17.1) vs. 30.3 (17.7–40.2) mL/m
2;
p < 0.001) and a higher LAEF (62.0% (56.0–68.0) vs. 45% (29.0–59.0);
p < 0.001). The median MCF in the overall cohort was 57.34 (50.1–64.9). Healthy adults showed higher MCF values than HCM (
p < 0.001) and CA patients (
p = 0.002), while they did not differ as compared with isolated hypertension (
p = 0.756) (
Figure 2).
MCF showed a weak level of correlation with LVEF in the overall cohort (R
2 = 0.136) and the four study subgroups as well (healthy adults, R
2 = 0.039; isolated hypertension, R
2= 0.089; HCM, R
2 = 0.225; CA, R
2 = 0.102). ROC analyses showed that MCF had a high capability to differentiate between healthy adults and HCM patients (sensitivity 75.9%, specificity 77.8%, AUC 0.814) and between healthy adults and CA patients (sensitivity 87.0%, specificity 100%, AUC 0.959), but not between healthy adults and isolated hypertension (sensitivity 50.0%, specificity 65.5%, AUC 0.575). The best cut-off values were 55.37, 52.86, and 62.24, respectively (
Figure 3).
5. Discussion
The MCF is a dimensionless index with a clear, simple definition supported by proof of a predictive value when calculated by cardiac magnetic resonance [
9,
12,
28,
29,
30]. The primary finding of this study was that in patients with normal EF, the MCF by DHM clearly distinguishes the groups of normal subjects and patients with isolated hypertension from the groups of patients with HCM and CA. Despite similar degrees of hypertrophy between isolated hypertensive and HCM groups, we found that the MCF was significantly different. The MCF decreased in patients with HCM and even more in patients with CA, reflecting a relatively greater increase in SV than myocardial volume (
Figure 4). Of note, in our cohort, patients with abnormal MCF (<50%) demonstrated a higher hemodynamic burden (increased LAVi max, LAVi min, decreased LAEF) compared with patients with normal MCF, which strengthens our evidence even more. Thus, the MCF by DHM appears as an additional appealing echocardiographic parameter in patients with hypertrophic phenotypes.
The differentiation of pathologic hypertrophy is challenging in patients with mild forms of hypertrophy and normal EF. We showed that the MCF was not significantly different among normal subjects and isolated hypertensive patients. The lack of statistically significant difference may be due to the small sample size in combination with nonadvanced hypertensive heart disease and the lack of the superimposition of clinical heart failure in the group with isolated hypertension. A previous study showed that the MCF by manual 3DE could differentiate subjects with hypertensive hypertrophy and heart failure from endurance athletes with hypertrophy [
7].
Echocardiography is a first-line screening tool for patients with LV hypertrophy and normal EF. In both HCM and CA, both the SV and LVEDV are reduced. Therefore, the calculated ratio of SV to LVEDV (i.e., the EF) typically falls into the normal or near-normal range even though myocardial shortening and systolic function are significantly hampered [
31]. As a result, cardiomyocyte function abnormalities should be detected using measurements of myocardial shortening (i.e., MCF and strain) [
9,
10,
11,
12]. Pagourelias et al. showed that the deformation parameters differentiate better CA from other hypertrophic substrates than MCF calculated by 2DE [
11]. However, it is worth noting that the MCF requires precise SV and myocardial volume measurement. Therefore, its use in clinical practice should be restricted to 3DE since estimates of these parameters obtained by 2DE techniques are neither sufficiently accurate nor reproducible to be comparable to 3DE results [
32,
33]. Conversely, DHM provides a multiparametric output quickly at the same time (i.e., volume and function), in conjunction with the proven accuracy and reproducibility of LV mass and volumes [
18,
19], allowing for the broadly reliable MCF application in clinical practice.
6. Limitations
Our study was retrospective in design, and the sub-analysis of the patients with HCM and CA was restricted to a small group. However, all our groups were strictly defined, and the number of patients included is similar compared with other studies investigating LV hypertrophy differential diagnosis.
The healthy sedentary subjects and those involved in competitive sports were not differentiated. Indeed, the MCF is increased in subjects with physiologic hypertrophy, reflecting a relatively greater increase in SV than myocardial volume [
7].
We do not account for LV global longitudinal strain because it was not feasible in a non-negligible percentage of the sample analyzed. However, conceptually, the MCF is comparable to myocardial strain because it is a generalized measure of myocardial shortening [
5]. Yet, the MCF combines information on shortening from all domains (longitudinal, radial, and circumferential) into a single value [
8], whereas strain quantifies shortening in a particular section of the heart [
31]. Nevertheless, more data are required to assess their reciprocal diagnostic benefit.
A more appropriately powered study examining associations would allow for a more granular disease-specific sub-analysis highlighting eventual variations of the MCF concerning HCM phenotypes, different stages of CA, and hypertensive heart disease. This issue may contribute to future studies on disease stages and risk stratification. Indeed, the probability of MCF becoming abnormal gradually increases across the spectrum of CA deposition [
2].
The MCF by DHM was not performed on top of conventional 2DE evaluation for comparative analysis [
34,
35,
36,
37]. However, since the DHM has been available, our echo lab has stopped performing 2DE volumetric analysis regularly. Moreover, our group recently showed that the LV mass assessment by DHM showed systematic differences and wide limits of agreements compared with the standard 2DE quantification [
38].
We were unable to gather more detailed information on the history and severity of hypertension since this was a retrospective analysis of a group that had transthoracic echocardiography.
Finally, although easy to calculate, MCF by DHM is still a derived parameter. Therefore, postprocessing algorithms should hopefully be developed quickly to estimate MCF within an even shorter time delay regarding transferability to the clinical practice.
7. Conclusions
The present data suggested that the quantification of the MCF by DHM can refine our echocardiographic discrimination capacity in patients with hypertrophic phenotype and normal EF. The following steps will require assessing its utility in other groups and different clinical scenarios for more general application in clinical practice.
Author Contributions
Conceptualization, A.B.; Methodology, A.B., J.F.I., M.B. and G.B.; Formal analysis, A.B., J.F.I., M.B. and M.V.; Investigation, A.B., J.F.I., M.B., N.B., V.L., L.T.T., S.C., M.S., C.M., F.M., I.R., L.G., M.M., D.A.M. and M.V.; Data curation, A.B., J.F.I. and M.B.; Writing—original draft, A.B., J.F.I., M.B., N.B., V.L., L.T.T., S.C., M.S., C.M., F.M., I.R., L.G., M.M., D.A.M., M.V. and G.B.; Writing—review & editing, A.B., J.F.I. and G.B.; Supervision, A.B. and G.B.. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
The study protocol followed the ethical guidelines of the 1975 Declaration of Helsinki and was approved by the local ethic committee (Protocol Code: 234-2021, date of approval: 11 May 2021).
Informed Consent Statement
Informed consent was obtained from all subjects involved in the study whenever feasible given the retrospective, observational nature of the study and data were anonymized.
Data Availability Statement
The data presented in this study are available on reasonable request from the corresponding author.
Conflicts of Interest
G.B. received small speaker’s fees from Bayer, Boston, Boehringer, Daiichi Sankyo, Janssen, and Sanofi, outside of the submitted work. The other authors declare no conflict of interest.
References
- Stokke, T.M.; Hasselberg, N.E.; Smedsrud, M.K.; Sarvari, S.I.; Haugaa, K.H.; Smiseth, O.A.; Edvardsen, T.; Remme, E.W. Geometry as a Confounder When Assessing Ventricular Systolic Function: Comparison Between Ejection Fraction and Strain. J. Am. Coll. Cardiol. 2017, 70, 942–954. [Google Scholar] [CrossRef]
- Knight, D.S.; Zumbo, G.; Barcella, W.; Steeden, J.A.; Muthurangu, V.; Martinez-Naharro, A.; Treibel, T.A.; Abdel-Gadir, A.; Bulluck, H.; Kotecha, T.; et al. Cardiac Structural and Functional Consequences of Amyloid Deposition by Cardiac Magnetic Resonance and Echocardiography and Their Prognostic Roles. JACC Cardiovasc. Imaging 2019, 12, 823–833. [Google Scholar] [CrossRef] [PubMed]
- Capasso, J.M.; Strobeck, J.E.; Sonnenblick, E.H. Myocardial mechanical alterations during gradual onset long-term hypertension in rats. Am. J. Physiol. 1981, 241, H435–H441. [Google Scholar] [CrossRef]
- Mann, D.L.; Urabe, Y.; Kent, R.L.; Vinciguerra, S.; Cooper, G. Cellular versus myocardial basis for the contractile dysfunction of hypertrophied myocardium. Circ. Res. 1991, 68, 402–415. [Google Scholar] [CrossRef] [PubMed]
- Maciver, D.H. The relative impact of circumferential and longitudinal shortening on left ventricular ejection fraction and stroke volume. Exp. Clin. Cardiol. 2012, 17, 5–11. [Google Scholar]
- Borlaug, B.A.; Sharma, K.; Shah, S.J.; Ho, J.E. Heart Failure with Preserved Ejection Fraction: JACC Scientific Statement. J. Am. Coll. Cardiol. 2023, 81, 1810–1834. [Google Scholar] [CrossRef]
- King, D.L.; El-Khoury Coffin, L.; Maurer, M.S. Myocardial contraction fraction: A volumetric index of myocardial shortening by freehand three-dimensional echocardiography. J. Am. Coll. Cardiol. 2002, 40, 325–329. [Google Scholar] [CrossRef]
- Matthews, S.D.; Rubin, J.; Cohen, L.P.; Maurer, M.S. Myocardial Contraction Fraction: A Volumetric Measure of Myocardial Shortening Analogous to Strain. J. Am. Coll. Cardiol. 2018, 71, 255–256. [Google Scholar] [CrossRef]
- Arenja, N.; Fritz, T.; Andre, F.; Riffel, J.H.; aus dem Siepen, F.; Ochs, M.; Paffhausen, J.; Hegenbart, U.; Schönland, S.; Müller-Hennessen, M.; et al. Myocardial contraction fraction derived from cardiovascular magnetic resonance cine images-reference values and performance in patients with heart failure and left ventricular hypertrophy. Eur. Heart J. Cardiovasc. Imaging 2017, 18, 1414–1422. [Google Scholar] [CrossRef]
- Shimada, Y.J.; Hoeger, C.W.; Latif, F.; Takayama, H.; Ginns, J.; Maurer, M.S. Myocardial Contraction Fraction Predicts Cardiovascular Events in Patients with Hypertrophic Cardiomyopathy and Normal Ejection Fraction. J. Card. Fail. 2019, 25, 450–456. [Google Scholar] [CrossRef]
- Pagourelias, E.D.; Mirea, O.; Duchenne, J.; Van Cleemput, J.; Delforge, M.; Bogaert, J.; Kuznetsova, T.; Voigt, J.-U. Echo Parameters for Differential Diagnosis in Cardiac Amyloidosis: A Head-to-Head Comparison of Deformation and Nondeformation Parameters. Circ. Cardiovasc. Imaging 2017, 10, e005588. [Google Scholar] [CrossRef] [PubMed]
- Rubin, J.; Steidley, D.E.; Carlsson, M.; Ong, M.L.; Maurer, M.S. Myocardial Contraction Fraction by M-Mode Echocardiography Is Superior to Ejection Fraction in Predicting Mortality in Transthyretin Amyloidosis. J. Card. Fail. 2018, 24, 504–511. [Google Scholar] [CrossRef] [PubMed]
- Arenja, N.; Andre, F.; Riffel, J.H.; aus dem Siepen, F.; Hegenbart, U.; Schönland, S.; Kristen, A.V.; Katus, H.A.; Buss, S.J. Prognostic value of novel imaging parameters derived from standard cardiovascular magnetic resonance in high risk patients with systemic light chain amyloidosis. J. Cardiovasc. Magn. Reson. 2019, 21, 53. [Google Scholar] [CrossRef] [PubMed]
- Armstrong, A.C.; Gidding, S.; Gjesdal, O.; Wu, C.; Bluemke, D.A.; Lima, J.A. LV mass assessed by echocardiography and CMR, cardiovascular outcomes, and medical practice. JACC Cardiovasc. Imaging 2012, 5, 837–848. [Google Scholar] [CrossRef] [PubMed]
- Dorosz, J.L.; Lezotte, D.C.; Weitzenkamp, D.A.; Allen, L.A.; Salcedo, E.E. Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: A systematic review and meta-analysis. J. Am. Coll. Cardiol. 2012, 59, 1799–1808. [Google Scholar] [CrossRef]
- Nolan, M.T.; Thavendiranathan, P. Automated Quantification in Echocardiography. JACC Cardiovasc. Imaging 2019, 12, 1073–1092. [Google Scholar] [CrossRef]
- Tsang, W.; Salgo, I.S.; Medvedofsky, D.; Takeuchi, M.; Prater, D.; Weinert, L.; Yamat, M.; Mor-Avi, V.; Patel, A.R.; Lang, R.M. Transthoracic 3D Echocardiographic Left Heart Chamber Quantification Using an Automated Adaptive Analytics Algorithm. JACC Cardiovasc. Imaging 2016, 9, 769–782. [Google Scholar] [CrossRef]
- Volpato, V.; Mor-Avi, V.; Narang, A.; Prater, D.; Gonçalves, A.; Tamborini, G.; Fusini, L.; Pepi, M.; Patel, A.R.; Lang, R.M. Automated, machine learning-based, 3D echocardiographic quantification of left ventricular mass. Echocardiography 2019, 36, 312–319. [Google Scholar] [CrossRef]
- Wu, V.C.; Kitano, T.; Chu, P.H.; Takeuchi, M. Left ventricular volume and ejection fraction measurements by fully automated 3D echocardiography left chamber quantification software versus CMR: A systematic review and meta-analysis. J. Cardiol. 2023, 81, 19–25. [Google Scholar] [CrossRef]
- Ommen, S.R.; Mital, S.; Burke, M.A.; Day, S.M.; Deswal, A.; Elliott, P.; Evanovich, L.L.; Hung, J.; Joglar, J.A.; Kantor, P.; et al. 2020 AHA/ACC Guideline for the Diagnosis and Treatment of Patients with Hypertrophic Cardiomyopathy: Executive Summary: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation 2020, 142, e533–e557. [Google Scholar] [CrossRef]
- Elliott, P.M.; Anastasakis, A.; Borger, M.A.; Borggrefe, M.; Cecchi, F.; Charron, P.; Hagege, A.A.; Lafont, A.; Limongelli, G.; Mahrholdt, H.; et al. 2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy: The Task Force for the Diagnosis and Management of Hypertrophic Cardiomyopathy of the European Society of Cardiology (ESC). Eur. Heart J. 2014, 35, 2733–2779. [Google Scholar] [CrossRef] [PubMed]
- Garcia-Pavia, P.; Rapezzi, C.; Adler, Y.; Arad, M.; Basso, C.; Brucato, A.; Burazor, I.; Caforio, A.L.P.; Damy, T.; Eriksson, U.; et al. Diagnosis and treatment of cardiac amyloidosis. A position statement of the European Society of Cardiology Working Group on Myocardial and Pericardial Diseases. Eur. J. Heart Fail. 2021, 23, 512–526. [Google Scholar] [CrossRef]
- Lang, R.M.; Badano, L.P.; Mor-Avi, V.; Afilalo, J.; Armstrong, A.; Ernande, L.; Flachskampf, F.A.; Foster, E.; Goldstein, S.A.; Kuznetsova, T.; et al. Recommendations for cardiac chamber quantification by echocardiography in adults: An update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J. Am. Soc. Echocardiogr. 2015, 28, 1–39.e14. [Google Scholar] [CrossRef] [PubMed]
- Mitchell, C.; Rahko, P.S.; Blauwet, L.A.; Canaday, B.; Finstuen, J.A.; Foster, M.C.; Horton, K.; Ogunyankin, K.O.; Palma, R.A.; Velazquez, E.J. Guidelines for Performing a Comprehensive Transthoracic Echocardiographic Examination in Adults: Recommendations from the American Society of Echocardiography. J. Am. Soc. Echocardiogr. 2019, 32, 1–64. [Google Scholar] [CrossRef]
- Barbieri, A.; Albini, A.; Chiusolo, S.; Forzati, N.; Laus, V.; Maisano, A.; Muto, F.; Passiatore, M.; Stuani, M.; Torlai Triglia, L.; et al. Three-Dimensional Automated, Machine-Learning-Based Left Heart Chamber Metrics: Associations with Prevalent Vascular Risk Factors and Cardiovascular Diseases. J. Clin. Med. 2022, 11, 7363. [Google Scholar] [CrossRef] [PubMed]
- King, D.L.; Coffin, L.E.-K.; Maurer, M.S. Noncompressibility of myocardium during systole with freehand three-dimensional echocardiography. J. Am. Soc. Echocardiogr. 2002, 15, 1503–1506. [Google Scholar] [CrossRef] [PubMed]
- Italiano, G.; Tamborini, G.; Fusini, L.; Mantegazza, V.; Doldi, M.; Celeste, F.; Gripari, P.; Muratori, M.; Lang, R.M.; Pepi, M. Feasibility and Accuracy of the Automated Software for Dynamic Quantification of Left Ventricular and Atrial Volumes and Function in a Large Unselected Population. J Clin. Med. 2021, 10, 5030. [Google Scholar] [CrossRef]
- Chuang, M.L.; Gona, P.; Salton, C.J.; Yeon, S.B.; Kissinger, K.V.; Blease, S.J.; Levy, D.; O’Donnell, C.J.; Manning, W.J. Usefulness of the left ventricular myocardial contraction fraction in healthy men and women to predict cardiovascular morbidity and mortality. Am. J. Cardiol. 2012, 109, 1454–1458. [Google Scholar] [CrossRef] [PubMed]
- Abdalla, M.; Akwo, E.A.; Bluemke, D.A.; Lima, J.A.C.; Shimbo, D.; Maurer, M.S.; Bertoni, A.G. Association between reduced myocardial contraction fraction and cardiovascular disease outcomes: The Multi-Ethnic Study of Atherosclerosis. Int. J. Cardiol. 2019, 293, 10–16. [Google Scholar] [CrossRef]
- Hou, X.; Xiong, X.; Li, X.; Bi, J.; Xu, G.; Wang, Y.; Jiang, S. Predictive value of cardiac magnetic resonance mechanical parameters for myocardial fibrosis in hypertrophic cardiomyopathy with preserved left ventricular ejection fraction. Front. Cardiovasc. Med. 2022, 9, 1062258. [Google Scholar] [CrossRef]
- Maurer, M.S.; Packer, M. How Should Physicians Assess Myocardial Contraction?: Redefining Heart Failure With a Preserved Ejection Fraction. JACC Cardiovasc. Imaging 2020, 13, 873–878. [Google Scholar] [CrossRef] [PubMed]
- Patel, H.N.; Miyoshi, T.; Addetia, K.; Henry, M.P.; Citro, R.; Daimon, M.; Gutierrez Fajardo, P.; Kasliwal, R.R.; Kirkpatrick, J.N.; Monaghan, M.J.; et al. Normal Values of Cardiac Output and Stroke Volume According to Measurement Technique, Age, Sex, and Ethnicity: Results of the World Alliance of Societies of Echocardiography Study. J. Am. Soc. Echocardiogr. 2021, 34, 1077–1085.e1. [Google Scholar] [CrossRef] [PubMed]
- Addetia, K.; Miyoshi, T.; Amuthan, V.; Citro, R.; Daimon, M.; Gutierrez Fajardo, P.; Kasliwal, R.R.; Kirkpatrick, J.N.; Monaghan, M.J.; Muraru, D.; et al. Normal Values of Left Ventricular Size and Function on Three-Dimensional Echocardiography: Results of the World Alliance Societies of Echocardiography Study. J. Am. Soc. Echocardiogr. 2022, 35, 449–459. [Google Scholar] [CrossRef] [PubMed]
- Tendler, A.; Helmke, S.; Teruya, S.; Alvarez, J.; Maurer, M.S. The myocardial contraction fraction is superior to ejection fraction in predicting survival in patients with AL cardiac amyloidosis. Amyloid 2015, 22, 61–66. [Google Scholar] [CrossRef]
- Castaño, A.; Narotsky, D.L.; Hamid, N.; Khalique, O.K.; Morgenstern, R.; DeLuca, A.; Rubin, J.; Chiuzan, C.; Nazif, T.; Vahl, T.; et al. Unveiling transthyretin cardiac amyloidosis and its predictors among elderly patients with severe aortic stenosis undergoing transcatheter aortic valve replacement. Eur. Heart J. 2017, 38, 2879–2887. [Google Scholar] [CrossRef]
- Milani, P.; Dispenzieri, A.; Scott, C.G.; Gertz, M.A.; Perlini, S.; Mussinelli, R.; Lacy, M.Q.; Buadi, F.K.; Kumar, S.; Maurer, M.S.; et al. Independent Prognostic Value of Stroke Volume Index in Patients with Immunoglobulin Light Chain Amyloidosis. Circ. Cardiovasc. Imaging 2018, 11, e006588. [Google Scholar] [CrossRef]
- Siepen, F.A.D.; Bauer, R.; Voss, A.; Hein, S.; Aurich, M.; Riffel, J.; Mereles, D.; Röcken, C.; Buss, S.J.; Katus, H.A.; et al. Predictors of survival stratification in patients with wild-type cardiac amyloidosis. Clin. Res. Cardiol. 2018, 107, 158–169. [Google Scholar] [CrossRef]
- Barbieri, A.; Bursi, F.; Camaioni, G.; Maisano, A.; Imberti, J.F.; Albini, A.; De Mitri, G.; Mantovani, F.; Boriani, G. Echocardiographic Left Ventricular Mass Assessment: Correlation between 2D-Derived Linear Dimensions and 3-Dimensional Automated, Machine Learning-Based Methods in Unselected Patients. J. Clin. Med. 2021, 10, 1279. [Google Scholar] [CrossRef]
Figure 1.
Flowchart depicting the patient selection process. * Absence of diabetes, hypertension, previous or current heart disease, cardiac implantable electronic devices, stroke, chronic obstructive pulmonary disease, venous thromboembolism, cancer, previous or current systemic diseases that may have an impact on the cardiovascular system, drug therapy, or other treatments with cardiovascular effects, normal cardiovascular physical examination, normal ECG at rest) without clinical indication of DHM. 2DE: bidimensional echocardiography; DHM: Dynamic Heart Model; LVEF: left ventricular ejection fraction; VHD: valvular heart disease; BMI: body mass index; IHT: isolated arterial hypertension; HCM: hypertrophic cardiomyopathy; CA: cardiac amyloidosis.
Figure 1.
Flowchart depicting the patient selection process. * Absence of diabetes, hypertension, previous or current heart disease, cardiac implantable electronic devices, stroke, chronic obstructive pulmonary disease, venous thromboembolism, cancer, previous or current systemic diseases that may have an impact on the cardiovascular system, drug therapy, or other treatments with cardiovascular effects, normal cardiovascular physical examination, normal ECG at rest) without clinical indication of DHM. 2DE: bidimensional echocardiography; DHM: Dynamic Heart Model; LVEF: left ventricular ejection fraction; VHD: valvular heart disease; BMI: body mass index; IHT: isolated arterial hypertension; HCM: hypertrophic cardiomyopathy; CA: cardiac amyloidosis.
Figure 2.
Myocardial contraction fraction values across patients’ subgroups CA, cardiac amyloidosis; HCM, hypertrophic cardiomyopathy; IHT, isolated hypertension; MCF, myocardial contraction fraction.
Figure 2.
Myocardial contraction fraction values across patients’ subgroups CA, cardiac amyloidosis; HCM, hypertrophic cardiomyopathy; IHT, isolated hypertension; MCF, myocardial contraction fraction.
Figure 3.
Performance of myocardial contraction fraction for detecting hypertrophic phenotypes. (Panel A) Receiver-operating characteristics (ROC) curve showing the performance of myocardial contraction fraction for detecting hypertrophic cardiomyopathy. (Panel B) ROC curve showing the performance of myocardial contraction fraction for detecting Cardiac amyloidosis. (Panel C) ROC curve showing the performance of myocardial contraction fraction for detecting isolated hypertension. AUC, area under the curve; CA, cardiac amyloidosis; HCM, hypertrophic cardiomyopathy; IHT, isolated hypertension.
Figure 3.
Performance of myocardial contraction fraction for detecting hypertrophic phenotypes. (Panel A) Receiver-operating characteristics (ROC) curve showing the performance of myocardial contraction fraction for detecting hypertrophic cardiomyopathy. (Panel B) ROC curve showing the performance of myocardial contraction fraction for detecting Cardiac amyloidosis. (Panel C) ROC curve showing the performance of myocardial contraction fraction for detecting isolated hypertension. AUC, area under the curve; CA, cardiac amyloidosis; HCM, hypertrophic cardiomyopathy; IHT, isolated hypertension.
Figure 4.
Example of 3D measurements (LV volumes and LV mass) obtained from automated DHM in a patient with cardiac amyloidosis and normal EF (54%). This advanced echocardiography allows for accurate, automated measurements of chamber volumes and function providing larger, more accurate LV volumes with good agreement with cardiac magnetic resonance when analyzed using the default settings of the boundary detection sliders (end-diastolic default position = 60/60; end-systolic default position = 30/30). LV myocardial mass (233 g) divided by the mean density of myocardium of 1.05 g/mL presents LV myocardial volume (221 mL). The ratio of SV (88 mL) to myocardial volume calculated the Myocardial Contraction Fraction (39%), significantly lower than the EF. LV: left ventricular; DHM: Dynamic Heart Model, Philips Healthcare, Andover, MA, USA; SV: stroke volume; EF: ejection fraction. DHM automatically measures chamber volumes throughout the cardiac cycle, resulting in LV time curve (yellow).
Figure 4.
Example of 3D measurements (LV volumes and LV mass) obtained from automated DHM in a patient with cardiac amyloidosis and normal EF (54%). This advanced echocardiography allows for accurate, automated measurements of chamber volumes and function providing larger, more accurate LV volumes with good agreement with cardiac magnetic resonance when analyzed using the default settings of the boundary detection sliders (end-diastolic default position = 60/60; end-systolic default position = 30/30). LV myocardial mass (233 g) divided by the mean density of myocardium of 1.05 g/mL presents LV myocardial volume (221 mL). The ratio of SV (88 mL) to myocardial volume calculated the Myocardial Contraction Fraction (39%), significantly lower than the EF. LV: left ventricular; DHM: Dynamic Heart Model, Philips Healthcare, Andover, MA, USA; SV: stroke volume; EF: ejection fraction. DHM automatically measures chamber volumes throughout the cardiac cycle, resulting in LV time curve (yellow).
Table 1.
Baseline characteristics of the overall cohort according to myocardial contraction fraction values.
Table 1.
Baseline characteristics of the overall cohort according to myocardial contraction fraction values.
| MCF ≥ 50% (n = 141) | MCF < 50% (n = 46) | Total (n = 187) | p-Value |
---|
Age, years | 57.00 (46.0–70.0) | 71.50 (59.0–81.0) | 61.00 (48.3–72.8) | <0.001 |
Female | 76 (53.9) | 12 (26.1) | 88 (47.1) | <0.001 |
Heart rate, bpm | 69.00 (62.0–77.0) | 67.50 (60.8–81.5) | 69.00 (62.0–78.0) | 0.791 |
Hypertension | 78 (55.3) | 21 (45.7) | 99 (52.9) | 0.308 |
Diabetes | 0.0 (0.0) | 2 (4.3) | 2 (1.1) | 0.060 |
CAD | 1 (0.7) | 4 (8.7) | 5 (2.7) | 0.014 |
ACS | 1 (0.7) | 2 (4.3) | 3 (1.6) | 0.150 |
Stroke/TIA | 1 (0.7) | 1 (2.2) | 2 (1.1) | 0.432 |
Heart failure | 0 (0.0) | 0 (0.0) | 0 (0.0) | NA |
Atrial fibrillation | 1 (0.7) | 8 (17.4) | 9 (4.8) | <0.001 |
CIED | 2 (1.4) | 5 (10.9) | 7 (3.7) | 0.004 |
Pulmonary embolism | 0 (0.0) | 1 (2.2) | 1 (0.5) | 0.246 |
Healthy adults | 49 (90.7) | 5 (9.3) | 54 (100) | <0.001 |
Isolated hypertension | 76 (87.4) | 11 (12.6) | 87 (100) |
Hypertrophic cardiomyopathy | 15/36 (41.7) | 21/36 (58.3) | 36736 (100) |
Cardiac amyloidosis | 1 (10.0) | 9 (90.0) | 10 (100) |
Table 2.
Baseline characteristics of the overall cohort according to myocardial contraction fraction values.
Table 2.
Baseline characteristics of the overall cohort according to myocardial contraction fraction values.
| MCF ≥ 50% (n = 141) | MCF < 50% (n = 46) | Total (n = 187) | p-Value |
---|
EDD, mm | 48.00 (44.00–51.00) | 44.00 (40.75–49.25) | 47.00 (44.00–51.00) | 0.006 |
LV Mass-i (2D), g | 73.96 (62.60–90.81) | 114.49 (75.18–141.48) | 76.65 (63.17–99.92) | <0.001 |
LV Mass-i, g/m2 | 73.81 (63.63–82.93) | 93.25 (84.11–109.14) | 77.37 (67.05–89.47) | <0.001 |
LV EDVi (2D), mL/m2 | 53.99 (53.18–58.62) | 54.79 (50.27–60.47) | 53.99 (53.31–58.05) | 0.967 |
LV EDVi, mL/m2 | 72.27 (62.88–81.78) | 68.20 (59.72–82.12) | 71.82 (62.32–81.66) | 0.469 |
LV ESVi, mL/m2 | 28.60 (22.96–35.81) | 31.97 (24.60–38.70) | 28.71 (23.49–36.04) | 0.154 |
SVi, g/m2 | 42.71 (37.46–48.87) | 39.69 (33.94–44.48) | 42.06 (36.66–48.32) | 0.006 |
LVEF, % | 60.00 (56.00–63.50) | 56.00 (51.75–60.25) | 58.50 (55.00–63.00) | <0.001 |
MCF | 60.43 (55.28–66.44) | 44.99 (40.11–47.94) | 57.34 (50.06–64.88) | <0.001 |
LAVi Max, mL/m2 | 34.37 (28.35–42.66) | 54.01 (41.25–65.25) | 37.13 (29.52–48.59) | <0.001 |
LAVi Min, mL/m2 | 12.72 (9.43–17.06) | 30.25 (17.74–40.24) | 14.33 (10.10–23.34) | <0.001 |
LAEF, % | 62.00 (56.00–68.00) | 45.00 (29.00–59.00) | 60.00 (51.00–66.00) | <0.001 |
| Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).