Next Article in Journal
Effect of Hypercholesterolemia, Systemic Arterial Hypertension and Diabetes Mellitus on Peripapillary and Macular Vessel Density on Superficial Vascular Plexus in Glaucoma
Next Article in Special Issue
A Comparative Study of Temporomandibular Joints in Adults with Definite Sleep Bruxism on Magnetic Resonance Imaging and Cone-Beam Computer Tomography Images
Previous Article in Journal
Stage IV Colorectal Cancer Management and Treatment
Previous Article in Special Issue
A CBCT Investigation of the Sella Turcica Dimension and Sella Turcica Bridging in Different Vertical Growth Patterns
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Impact of Acrylic and Silicone-Based Soft-Liner Materials on Biting Force and Quality of Life of the Complete Denture Wearers: A Randomized Clinical Trial

by
Ahmed Yaseen Alqutaibi
1,2,*,
Ahmad A. Alnazzawi
1,
Ahmed E. Farghal
1,
Ramy M. Bakr
3 and
Ihab Ismail Mahmoud
4
1
Substitutive Dental Sciences Department, College of Dentistry, Taibah University, Al Madinah 41311, Saudi Arabia
2
Prosthodontics Department, College of Dentistry, Ibb University, Ibb 70270, Yemen
3
Removable Prosthodontics Department, Future University, Cairo 11835, Egypt
4
Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo 11884, Egypt
*
Author to whom correspondence should be addressed.
J. Clin. Med. 2023, 12(5), 2073; https://doi.org/10.3390/jcm12052073
Submission received: 19 January 2023 / Revised: 28 February 2023 / Accepted: 1 March 2023 / Published: 6 March 2023
(This article belongs to the Special Issue Clinical Updates in Oral Rehabilitation)

Abstract

:
This rerandomized clinical trial evaluated the influence of soft liners (SL) on biting force, pain perception, and the oral health-related quality of life (OHRQoL) of complete denture wearers. Twenty-eight completely edentulous patients complaining of ill-fitting lower complete dentures were selected to participate in the study from the Dental Hospital, College of Dentistry, Taibah University. All patients received new complete maxillary and mandibular dentures; then they were randomly divided into two groups (14 patients in each group): the acrylic-based SL group, in which the mandibular denture was lined with an acrylic-based soft liner, and the silicone-based SL group, in which the mandibular denture was lined with a silicone-based soft liner. OHRQoL and maximum bite force (MBF) were assessed in this study before denture relining (baseline), then at one month and three months after relining. The finding showed that both treatment modalities significantly improved the OHRQoL of included patients at one-month and three-month periods compared to baseline records (i.e., dentures before relining) with a statistically significant difference (p < 0.05). However, there is no statistical difference between groups at the baseline, one-, and three-month follow-up periods. Regarding maximum biting force, when acrylic-based SL is compared to silicone-based SL, there is no statistical difference between groups at baseline (75 ± 31 and 83 ± 32 N) and one-month follow-up periods (145 ± 53 and 156 ± 49 N); however, after three months of function, the silicone-based group recorded 166 ± 57 N statistically significant high biting force compared to the acrylic-based group that recorded 116 ± 47 N (p < 0.05). Permanent soft denture liners positively affect maximum biting force, pain perception, and OHRQoL more than conventional dentures. After three months, silicone-based SL outperformed acrylic-based soft liners in maximum biting force, which may indicate better long-term results.

1. Introduction

With increased life expectancy, the effective demand and need for complete dentures continue to grow [1]. Nonetheless, wearing complete dentures may have negative consequences for the health of oral and denture-supporting tissues. One of the issues that complete denture wearers face is significant changes in masticatory function compared to dentate subjects. Furthermore, the complete denture wearer experiences more pain in the supporting mucosa and a reduction in the bite force, increasing the risk of masticatory muscle atrophy, which may lead to changes in dietary habits and an impaired nutritional status, resulting in a low-quality life [2]. These patients’ functional difficulties can be reduced using dental implants [3,4] or soft denture liners [5].
Even though dental implants are highly effective in supporting mandibular dentures, as reported in several trials [6,7,8], they are not feasible for all cases because of insufficient underlying bone or the presence of medical and financial restrictions [9]. Alternatively, soft denture liners have several advantages, including no need for surgical intervention and a low treatment cost. Besides, the resilient denture liner materials’ flexibility, resiliency, and shock absorbency help reduce and distribute the masticatory load to the ridge [10,11,12,13].
Denture liners can be either hard [14,15], usually made of polymethylmethacrylate [16,17,18], or soft liner (SL) (i.e., resilient) [19,20,21,22]. Acrylic-based SL is produced by adding plasticizers to the acrylic resin, and silicone-based SL is a mixture of siloxane and silica that remains “soft” after cross-linking/setting [20,22,23]. SL materials have been used in dental fields for over a century as resilient substances attached to the fitting surface of a denture to reduce localized point pressures. Due to their elastic nature, soft liners have a cushion effect as they absorb energy [20], so they can help heal the inflamed mucosa [24,25,26], distribute the functional load in the support area of the prostheses [27,28], and improve their adaptation and retention [29].
Because acrylic-based SL and silicone-based SL have different mechanical properties, their clinical effects differ [30]. In several trials [31,32], the acrylic-based SL’s clinical efficacy and patient satisfaction were compared to conventional dentures. It found that the patients who received dentures with SL were more satisfied with chewing and comfort and had less pain. However, when acrylic-based SL was compared to silicone-based SL, there were conflicting results in the published research on what was better. Some studies [33,34] reported that silicone-based SL was preferred over acrylic ones. Other studies [12,35] revealed that acrylic-based SL is more effective as a denture lining material in terms of durability. Unfortunately, most of the published literature that compared acrylic-based SL and silicone-based SL were in vitro studies or nonrandomized clinical trials.
As a result, solid research based on a well-conducted randomized clinical trial regarding the effect of different permanent soft denture liners is currently lacking. This study aimed to evaluate the impact of acrylic- and silicone-based soft liners on pain perception, maximum biting force (MBF), and oral health-related quality of life (OHRQoL) in complete denture wearers. The research question is: in patients with ill-fitting mandibular complete dentures, will the acrylic-based SL improve OHRQoL, biting force, and pain perception compared to the silicone-based SL?
The null hypothesis was that the improvement in OHRQoL, biting force, and pain perception would be the same for complete denture wearers with acrylic or silicone-based soft liners.

2. Materials and Methods

2.1. Trial Design

A double-blind, randomized clinical trial was carried out, with design and reporting following the CONSORT guidelines. The research was carried out at Taibah University Dental Hospital in Madinah, a city in Saudi Arabia’s western region.
A signed, written, informed consent was taken from patients before starting any procedures. The Research Ethics Committee at Taibah University approved the proposal for this study (approval # 11012020).

2.2. Participants

The study population consisted of those completely edentulous patients complaining of ill-fitting lower complete dentures and wishing to construct new dentures. They were selected to participate in this study. The inclusion criteria include participants being able to follow simple instructions and sign informed consent. They had enough inter-arch distance to accommodate, and with a class I jaw relationship (i.e., the maxillary alveolar ridge crest is directly above the mandibular ridge). On the other hand, bruxers and those with temporomandibular disorders, uncontrolled systemic disease, severe oral manifestations, xerostomia, or psychological or psychiatric disturbances that would affect treatment were excluded.
The size estimation was calculated using the OHRQoL rating as the primary outcome for this trial to determine the appropriate sample size. To fulfill the criteria of 80% power with a two-sided alpha level of 5% and to factor in potential participant dropouts, 24 subjects were enrolled in this study. The difference in means of OHIP between the two groups is set at 22. Based on the mean ± standard deviation of the overall OHIP score obtained in a previous study [36] (silicone-based SL: 25.8 ± 6.2, acrylic-based SL: 32.4 ± 5.9). However, assuming that 10% of participants drop out, the target number of participants is 28.

2.3. Interventions

All participants received new complete upper and lower dentures constructed according to a standard protocol, and the dentures were inserted following adequate adjustments. Patients are allowed to use the denture for three months; the baseline records were taken at the end of this period. Patients were randomly divided into two groups (14 patients in each group): the acrylic-based SL group, in which the mandibular denture was lined with an acrylic-based soft liner (VertexTMSoft, Vertex-Dental, Zeist, The Netherlands); and the silicone-based SL group, in which the mandibular denture was lined with a silicone-based soft liner (Molloplast-BTM DETAX). The mandibular dentures were relined following the manufacturer’s recommendations. The soft liner’s thickness was controlled using a vacuum-formed spacer constructed on a mandibular duplicated cast used to create a space of 2 mm for soft liners.

2.4. Outcomes

The primary outcome was the oral health-related quality of life (OHRQoL), and the secondary outcomes were the maximum bite force (MBF) and pain perception.
OHRQoL and maximum bite force (MBF) were assessed in this study before denture relining (baseline), then at one month and three months after relining. The pain perception during baseline and the first adjustment session following the initial fitting of the denture.
This study used the Arabic version of the OHIP-EDENT questionnaire [37]. The original questions were grouped according to seven subscales, or domains. Patients responded by rating how frequently oral health problems interfered with their daily activities (4: very often, 3: fairly often, 2: occasionally, 1: rarely, and 0: never). The OHIP-EDENT scores range from 0 to 76, with lower scores indicating better OHRQoL. Care providers were counseled to avoid making comments about treatment possibilities to subjects and were not present when subjects completed the OHIP questionnaires. The pain perception during the first adjustment session was assessed using a 100-mm VAS scale.
The biting force was recorded using an occlusal force meter (GM10; Nagano Keiki, Tokyo, Japan). An occlusal force meter measured the MBF bilaterally at the first molar region. The patient was asked to sit upright, and the instrument was positioned in the first molar region. At maximum intercuspation, the patient was directed to bite as hard as possible three times per side, with a two-minute rest period. The mean maximum biting occlusal force (N) for the three readings was calculated using the patient’s MBF, and the mean of two sides was taken [38]. The MBF was assessed by an independent assessor, unaware of the nature of the interventions.

2.5. Randomization

2.5.1. Sequence Generation

The random sequence was generated using a particular website concerned with the randomization process known as Research Randomizer (https://www.randomizer.org/) (accessed on 2 April 2021), where the patients were randomly divided into two groups (14 patients in each group).

2.5.2. Allocation, Concealment Mechanism, and Implementation

One researcher, who was not involved in the patient selection process, was aware of the randomization procedure and had access to the randomization lists saved on a password-protected portable computer. The randomized codes were sealed in sequentially numbered, identical, and opaque envelopes. Patients were asked to pick one of the envelopes, and the investigator, aware of the randomization method, was asked about the particular group and treated appropriately.

2.6. Blinding

It was impossible to blind the dentists who made the lined dentures. However, the outcome assessor was blind to the participant’s group. Patients were also kept unaware of any information regarding their assigned group.

2.7. Statistical Methods

Statistical analysis was performed using SPSS version 21 (SPSS Inc.). Patients’ baseline characteristics for the two interventions were recorded using frequency distributions and descriptive statistics using a Student’s t-test for continuous variables and a chi-square test for categorical data. For the OHRQoL, MBF, and pain perception, mean values were compared by an independent t-test to compare the two groups and an ANOVA to compare the effect of time in each group. The significance level was set at 5% for all statistical analyses.

3. Results

A sample of 28 patients with a mean age of 59.4 years was included in this study. A total of 28 complete dentures were received.

3.1. Participant Flow

All patients (14 in acrylic-based SL and 14 in silicone-based SL) attended the three-month follow-up, as observed in the participants’ flow chart (Figure 1).

3.2. Recruitment

Between March and December 2021, the patients were recruited. 28 of the 57 patients investigated met the inclusion criteria. All of them were asked to participate and accepted.

3.3. Baseline Data

Table 1 displays the baseline demographic characteristics of the patients who participated in the study. The baseline characteristics of the patients assigned to the treatment groups (acrylic-based SL and silicone-based SL) were similar.
There were no significant variations in any baseline features between the acrylic- and silicone-based soft-liner groups regarding age, edentulous period, the height of the alveolar ridge, mucosal thickness, mucosal resiliency, and denture difficulty classification (p > 0.05), as shown in Table 1.

3.4. Numbers Analyzed

The data of 28 patients, 14 in the acrylic-based SL group and 14 in the silicone-based SL group, were analyzed.

3.5. Outcomes and Estimation

3.5.1. The Oral Health-Related Quality of Life (OHRQoL)

Both treatment modalities significantly improved the quality of life of included patients at one-month and three months periods compared to baseline records (i.e., denture before relining) with a statistically significant difference (p < 0.05). However, there is no statistical difference between groups at the baseline, one-, and three-month follow-up periods. The improvement in OHRQoL was slightly more significant in the silicone-based SL group than in the acrylic-based group; nonetheless, this difference was neither statistically nor clinically significant (Table 2).

3.5.2. The Pain Perception

The pain perception during the first adjustment session following the initial fitting of the denture was assessed using a 100 mm VAS scale. There was a significant reduction in pain rating for both SL groups compared to conventional dentures, with no difference between acrylic-based and silicone-based SL. The pain ratings are shown in Table 3.

3.5.3. Maximum Biting Force

Regarding MBF, both treatment modalities improved the biting force of included patients compared to baseline records with a statistically significant difference (p < 0.05). When acrylic-based SL is compared to silicone-based SL, there is no statistical difference between groups at baseline (75 ± 31 and 83 ± 32 N) and one-month follow-up periods (145 ± 53 and 156 ± 49 N); however, after three months of function, the silicone-based group recorded 166 ± 57 N of statistically significant high biting force compared to the acrylic-based group that recorded 116 ± 47 N (p < 0.05) as shown in Table 4.

4. Discussion

This randomized clinical trial evaluated the influence of the lining of lower conventional complete dentures with acrylic versus silicone-based SLs on OHRQoL, pain perception, and MBF. The findings revealed that edentulous individuals who wore complete mandibular dentures with SL had better OHRQoL and MBF and experienced less pain than those with conventional dentures. The bite force and patient quality of life measurements are among the outcomes reflecting complete denture satisfaction and masticatory function.
In this study, both treatment modalities significantly improved OHRQoL compared to conventional complete dentures.
Recent years have seen a shift in the focus of dentistry from valuing only clinical assessments to measuring patients’ subjective experiences. This change in approach has led to the development of an essential construct, OHQoL. The OHIP-EDENT is a shortened version of the OHIP-49, which comprises 19 items targeting edentulous patients. This tool was selected from other questionnaires as it is more suitable for our study and could detect OHRQoL changes in edentulous patients with new or different prostheses [39,40]. The OHIP-EDENT demonstrated satisfactory validity, reliability, and agreement with reported complaints in various languages. It appears valid and reliable for assessing the OHRQoL associated with oral health [41,42,43,44,45,46].
In complete denture wearers, the pain of supporting tissue is a significant concern that affects function and treatment success [47,48]. The results of this study revealed a significant reduction in pain rating for both SL groups compared to conventional dentures, with no difference between acrylic-based and silicone-based SL. The first adjustment session after the initial fitting of the denture was the most opportune moment to establish the effects of soft liners for complete denture users since difficulties impacting the mucosa during this period are possibly the most severe and bothersome for complete denture wearers, as highlighted by Kimoto et al. [47]. In agreement with our findings, Kimoto et al. [47] found that patients with acrylic-based SL experienced less pain and fewer alveolar problems during the first adjustment session than those with conventional dentures.
The relined complete mandibular denture wearers experienced lower physical pain scores compared to baseline measures (i.e., conventional dentures). Although the pain perception measurement in this study is considered subjective, the reduction of pain recorded with VAS is supported by the finding of reduced physical pain scores (OHIP-DENT). This effect could be attributed to SL’s crushing effect, which results in less discomfort and fewer sore spots in the supporting and limiting structures and is more comfortable [39,47]. Based on these responses, patients with soft-relined dentures reported less physical discomfort than those with conventional dentures. According to Beck [48], 63% of mandibular denture difficulties were caused by discomfort. As a result, pain is a crucial concern for denture users. Furthermore, another study [49] suggests that doctors should handle mandibular dentures with caution owing to their better innate responsiveness to external stimuli than the maxilla. Thus, adding SL to mandibular dentures is therapeutically advantageous for edentulous individuals.
Bite force varies depending on where it is applied in the oral cavity. It is most significant in the area of the first molar (i.e., nearly 80% of total bite force is distributed there), and it is easier and faster to measure there. A series of recordings is more reliable than a single recording [50,51]. Both acrylic and silicone-based SL had a higher mean MBF than the conventional denture. This observation was in agreement with Hayakawa et al., who showed that the MBF increased following the placement of a denture with a silicone-based SL [5]. Denture wearers had only one-fifth to one-fourth of the occlusal force and masticatory performance of normal dentition [52]. Complete denture users reach the limit of their occlusal force sooner than those with natural dentition; this might be due to pressure from the denture base on the underlying mucosa and the pain threshold being reached. Thus, the higher MBF in both SLs could be attributed to the liner’s elasticity, which reduced stress on the alveolar ridge mucosa, and the increased pain threshold, which made the alveolar ridge mucosa more resilient to stress [53].
In this study, acrylic- and silicone-based SL had comparable effects on OHRQoL and MBF records, where both groups outperformed conventional dentures. This finding could be interpreted as a result of the more evenly distributed load on the underlying mucosa reported with soft liners, which relieves the supporting structures of excessive mechanical stress [53]. Consequently, the patients experience less pain and ulcers on the ridge, resulting in a longer occluding phase of the masticatory cycle and the ability to apply more force. This can be attributed to resilient liners absorbing energy and preventing force transmission to the underlying tissues [31]. Moreover, soft denture liners used with complete mandibular dentures improved edentulous patients’ masticatory ability. Compared to the conventional hard denture base, soft liners provided patients with fewer problems affecting the alveolar ridge during the first adjustment following the denture insertion [32,54].
There is no statistical difference between groups at one-month follow-up periods when acrylic-based SL is compared to silicone-based SL regarding MBF. However, after three months of function, the silicone-based group recorded a statistically significantly higher biting force than the acrylic-based group. The low molecular weight plasticizer that leaches out into the water could explain this in acrylic materials; at the same time, the water is absorbed into the materials, resulting in viscoelastic property loss, dimensional change, and deterioration of surface conditions. Over time, the silicone products remained stable due to the components’ low water absorption and solubility [33,34].
This finding agreed with a randomized clinical study by Kimoto et al. [32]. They investigated how acrylic-based SL affected complete denture wearers’ masticatory ability and concluded that masticatory efficiency was worse several months after lined denture insertion than at the time of insertion because the material had lost its initial softness.
Murata et al. [12] compared several soft liners to hard resins one week after denture insertion. MBF, patient satisfaction, and chewing time were all clinically assessed. The results revealed that the soft liners surpassed hard dentures in all assessed variables, which agreed with our findings. However, they report better results with acrylic-based SL than with silicone-based SL. The short duration of their study could explain this result, and a more extended observation period could have influenced the results.
The similarity of participants’ baseline characteristics (i.e., age, edentulous period, the height of the alveolar ridge, mucosal thickness, mucosal resiliency, and denture difficulty classification) between the two groups demonstrated that the randomization was adequate. The results of a well-executed randomization demonstrated high internal validity. Thus, unknown interaction variables that affect the results would be controlled. However, this research has shortcomings. First, this study was conducted by a single research facility that did not cover nearly all of Saudi Arabia, resulting in poor external validity. Second, we evaluated MBF, which is considered a static parameter that reflects masticatory efficiency. Individuals who create more forces during mastication have higher masticatory efficiency, so the MBF might be used as a clinical indicator to evaluate masticatory function. A multicenter, well-designed, randomized clinical trial with a broad range of sequentially selected people evaluating dynamic parameters of masticatory efficiency should be conducted to acquire convincing evidence.

5. Conclusions

This trial reveals that edentulous individuals wearing complete mandibular dentures with SL had superior biting force and OHRQoL than individuals wearing conventional complete dentures. After three months of function, silicone-based SL outperformed acrylic-based soft liners in maximum biting force, which may indicate better long-term results.

Author Contributions

Conceptualization, A.Y.A., A.A.A. and I.I.M.; methodology, A.Y.A. and I.I.M.; validation, R.M.B. and A.E.F.; formal analysis, A.Y.A.; investigation, A.E.F. and I.I.M.; and data curation, A.Y.A., A.A.A. and I.I.M. Writing—original draft preparation, A.Y.A., A.A.A., A.E.F., R.M.B. and I.I.M.; writing—review and editing, A.Y.A., A.A.A., A.E.F., R.M.B. and I.I.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted following the Declaration of Helsinki and approved by the Ethics Committee of the College of Dentistry, Taibah University (approval # 11012020).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Data is available upon request from authors.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

OHRQoL, oral health-related quality of life; MBF, maximum bite force; SL, soft liner; SD, standard deviation.

References

  1. Douglass, C.W.; Watson, A.J. Future needs for fixed and removable partial dentures in the United States. J. Prosthet. Dent. 2002, 87, 9–14. [Google Scholar] [CrossRef]
  2. McCord, J.F.; Tyson, K.W. A conservative prosthodontic option for the treatment of edentulous patients with atrophic (flat) mandibular ridges. Br. Dent. J. 1997, 182, 469–472. [Google Scholar] [CrossRef]
  3. Zarb, G.A.; Schmitt, A. The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto Study. Part II: The prosthetic results. J. Prosthet. Dent. 1990, 64, 53–61. [Google Scholar] [CrossRef]
  4. Cardoso, R.G.; De Melo, L.A.; Barbosa, G.A.S.; Calderon, P.D.S.; Germano, A.R.; Junior, W.M.; Carreiro, A. Impact of mandibular conventional denture and overdenture on quality of life and masticatory efficiency. Braz. Oral Res. 2016, 30, e102. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Hayakawa, I.; Hirano, S.; Takahashi, Y.; Keh, E.S. Changes in the masticatory function of complete denture wearers after relining the mandibular denture with a soft denture liner. Int. J. Prosthodont. 2001, 13, 227–231. [Google Scholar]
  6. Feine, J.S.; E Carlsson, G.; A Awad, M.; Chehade, A.; Duncan, W.J.; Gizani, S.; Head, T.; Heydecke, G.; Lund, J.P.; MacEntee, M.; et al. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology 2002, 19, 3–4. [Google Scholar]
  7. Helmy, M.-D.; Alqutaibi, A.; El-Ella, A.; Shawky, A. Effect of implant loading protocols on failure and marginal bone loss with unsplinted two-implant-supported mandibular overdentures: Systematic review and meta-analysis. Int. J. Oral Maxillofac. Surg. 2018, 47, 642–650. [Google Scholar] [CrossRef] [PubMed]
  8. Alqutaibi, A.Y.; Esposito, M.; Algabri, R.; Alfahad, A.; Kaddah, A.; Farouk, M.; Alsourori, A.A.A. Single vs. two implant-retained overdentures for edentulous mandibles: A systematic review. Eur. J. Oral Implant. 2017, 10, 243–261. [Google Scholar]
  9. Alqutaibi, A.; Kaddah, A.; Farouk, M. Randomized study on the effect of single-implant versus two-implant retained overdentures on implant loss and muscle activity: A 12-month follow-up report. Int. J. Oral Maxillofac. Surg. 2017, 46, 789–797. [Google Scholar] [CrossRef]
  10. Shim, J.S.; Watts, D.C. An examination of the stress distribution in a soft-lined acrylic resin mandibular complete denture by finite element analysis. Int. J. Prosthodont. 2000, 13, 19–24. [Google Scholar]
  11. Murata, H.; Haberham, R.C.; Hamada, T.; Taguchi, N. Setting and stress relaxation behavior of resilient denture liners. J. Prosthet. Dent. 1998, 80, 714–722. [Google Scholar] [CrossRef]
  12. Murata, H.; Taguchi, N.; Hamada, T.; Kawamura, M.; McCabe, J.F. Dynamic viscoelasticity of soft liners and masticatory function. J. Dent. Res. 2002, 81, 123–128. [Google Scholar] [CrossRef] [PubMed]
  13. Williamson, R.T. Clinical application of a soft denture liner: A case report. Quintessence Int. 1995, 26, 413–418. [Google Scholar] [PubMed]
  14. Chaves, C.D.A.L.; Machado, A.L.; Carlos, I.Z.; Giampaolo, E.T.; Pavarina, A.C.; Vergani, C.E. Cytotoxicity of monomers, plasticizer and degradation by-products released from dental hard chairside reline resins. Dent. Mater. 2010, 26, 1017–1023. [Google Scholar] [CrossRef]
  15. Urban, V.M.; Machado, A.L.; Vergani, C.E.; Giampaolo, E.T.; Pavarina, A.C.; de Almeida, F.G.; Cass, Q.B. Effect of water-bath post-polymerization on the mechanical properties, degree of conversion, and leaching of residual compounds of hard chairside reline resins. Dent. Mater. 2009, 25, 662–671. [Google Scholar] [CrossRef] [PubMed]
  16. Kou, Z.; Yi, Q.; Zhi, X.; Society of Dental Materials; Chinese Stomatological Association. Summary of the seventh national conference on the science of dental materials. Zhonghua Kou Qiang Yi Xue Za Zhi 2012, 47, 567–568. [Google Scholar]
  17. Mese, A.; Guzel, K.G. Effect of storage duration on the hardness and tensile bond strength of silicone- and acrylic resin-based resilient denture liners to a processed denture base acrylic resin. J. Prosthet. Dent. 2008, 99, 153–159. [Google Scholar] [CrossRef]
  18. Atsu, S.; Keskin, Y. Effect of silica coating and silane surface treatment on the bond strength of soft denture liner to denture base material. J. Appl. Oral Sci. 2013, 21, 300–306. [Google Scholar] [CrossRef]
  19. Liao, W.-C.; Pearson, G.J.; Braden, M.; Wright, P.S. The interaction of various liquids with long-term denture soft lining materials. Dent. Mater. 2012, 28, e199–e206. [Google Scholar] [CrossRef]
  20. Bail, M.; Jorge, J.H.; Urban, V.M.; Campanha, N.H. Surface Roughness of Acrylic and Silicone-Based Soft Liners: In Vivo Study in a Rat Model. J. Prosthodont. 2013, 23, 146–151. [Google Scholar] [CrossRef]
  21. Nowakowska-Toporowska, A.; Raszewski, Z.; Wieckiewicz, W. Color change of soft silicone relining materials after storage in artificial saliva. J. Prosthet. Dent. 2015, 115, 377–380. [Google Scholar] [CrossRef] [PubMed]
  22. Valentini, F.; Luz, M.S.; Boscato, N.; Pereira-Cenci, T. Biofilm formation on denture liners in a randomised controlled in situ trial. J. Dent. 2013, 41, 420–427. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  23. Santawisuk, W.; Kanchanavasita, W.; Sirisinha, C.; Harnirattisai, C. Mechanical properties of experimental silicone soft lining materials. Dent. Mater. J. 2013, 32, 970–975. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  24. Bates, J.F.; Smith, D.C. Evaluation of Indirect Resilient Liners for Dentures: Laboratory and Clinical Tests. J. Am. Dent. Assoc. 1965, 70, 344–353. [Google Scholar] [CrossRef] [PubMed]
  25. Goll, G.; Smith, D.E.; Plein, J.B. The effect of denture cleansers on temporary soft liners. J. Prosthet. Dent. 1983, 50, 466–472. [Google Scholar] [CrossRef]
  26. Nikawa, H.; Iwanaga, H.; Hamada, T.; Yuhta, S. Effects of denture cleansers on direct soft denture lining materials. J. Prosthet. Dent. 1994, 72, 657–662. [Google Scholar] [CrossRef]
  27. Sinobad, D.; Murphy, W.; Huggett, R.; Brooks, S. Bond strength and rupture properties of some soft denture liners. J. Oral Rehabil. 1992, 19, 151–160. [Google Scholar] [CrossRef]
  28. Aydın, A.; Terzioğlu, H.; Akınay, A.; Ulubayram, K.; Hasırcı, N. Bond strength and failure analysis of lining materials to denture resin. Dent. Mater. 1999, 15, 211–218. [Google Scholar] [CrossRef]
  29. Eick, J.D.; Craig, R.G.; Peyton, F.A. Properties of resilient denture liners in simulated mouth conditions. J. Prosthet. Dent. 1962, 12, 1043–1052. [Google Scholar] [CrossRef]
  30. Hayakawa, I.; Hirano, S.; Kobayashi, S.; Nagao, M.; Masuhara, E. The creep behavior of denture-supporting tissues and soft lining materials. Int. J. Prosthodont. 1994, 7, 339–347. [Google Scholar]
  31. Mangtani, N.; Pillai, R.S.; Babu, D.; Jain, V. Effect of resilient liner on masticatory efficiency and general patient satisfaction in completely edentulous patients. J. Dent. Spec. 2015, 3, 150–155. [Google Scholar] [CrossRef]
  32. Kimoto, S.; Yamamoto, S.; Shinomiya, M.; Kawai, Y. Randomized controlled trial to investigate how acrylic-based resilient liner affects on masticatory ability of complete denture wearers. J. Oral Rehabil. 2010, 37, 553–559. [Google Scholar] [CrossRef] [PubMed]
  33. Kalachandra, S.; Minton, R.; Taylor, D.; Takamata, T. Characterization of some proprietary soft lining materials. J. Mater. Sci. Mater. Med. 1995, 6, 647–652. [Google Scholar] [CrossRef]
  34. Kazanji, M.N.; Watkinson, A.C. Soft lining materials: Their absorption of, and solubility in, artificial saliva. Br. Dent. J. 1988, 165, 91–94. [Google Scholar] [CrossRef] [PubMed]
  35. Murata, H.; Hamada, T.; Sadamori, S. Relationship between viscoelastic properties of soft denture liners and clinical efficacy. Jpn. Dent. Sci. Rev. 2008, 44, 128–132. [Google Scholar] [CrossRef] [Green Version]
  36. Elawady, A.F.; Eissa, S.M.; Esmat, A.M. Effect of soft liner on clinical implication of tooth supported overdenture. J. Arab. Soc. Med. Res. 2021, 16, 1. [Google Scholar]
  37. Fayad, M.I. Oral health impact profile in edentulous patients rehabilitated with conventional and flexible complete denture. Egypt Dent. J. 2016, 62, 1–8. [Google Scholar]
  38. Sakr, H.; Fayad, M. Bite force and oral health impact profile in completely edentulous patients rehabilitated with two different types of denture bases. Tanta Dent. J. 2017, 14, 173–180. [Google Scholar]
  39. Pisani, M.X.; Malheiros-Segundo, A.d.L.; Balbino, K.L.; Souza, R.d.F.; Paranhos, H.d.F.O.; Lovato da Silva, C.H. Oral health related quality of life of edentulous patients after denture relining with a silicone-based soft liner. Gerodontology 2012, 29, 474–480. [Google Scholar] [CrossRef]
  40. Sutton, A.F.; Glenny, A.M.; McCord, J.F. Interventions for Replacing Missing Teeth: Denture Chewing Surface Designs in Edentulous People; The Cochrane Library: London, UK, 2005. [Google Scholar]
  41. Bural, C.; Geckili, O.; Erdogan, O.; Bektas-Kayhan, K.; Dayan, S.C. Reliability and validity of the Turkish version of oral health impact profile for edentulous subjects. Eur. Oral Res. 2021, 55, 67–73. [Google Scholar] [CrossRef]
  42. Larsson, P.; List, T.; Lundström, I.; Marcusson, A.; Ohrbach, R. Reliability and validity of a Swedish version of the Oral Health Impact Profile (OHIP-S). Acta Odontol. Scand. 2004, 62, 147–152. [Google Scholar] [CrossRef] [PubMed]
  43. Lu, H.; He, F.-M. Reliability and validity of the Chinese version of the 5-item oral health impact profile]. Hua Xi Kou Qiang Yi Xue Za Zhi 2020, 38, 145–148. [Google Scholar] [PubMed]
  44. Motallebnejad, M.; Hadian, H.; Mehdizadeh, S.; Hajiahmadi, M. Validity and reliability of the Persian version of the oral health impact profile (OHIP)-14. Caspian J. Intern. Med. 2011, 2, 314–320. [Google Scholar]
  45. Sato, Y.; Kaiba, Y.; Yamaga, E.; Minakuchi, S. Reliability and validity of a Japanese version of the Oral Health Impact Profile for edentulous subjects. Gerodontology 2011, 29, e1033–e1037. [Google Scholar] [CrossRef] [Green Version]
  46. Shrestha, B.; Niraula, S.R.; Parajuli, P.K.; Suwal, P.; Singh, R.K. Reliability and Validity of a Nepalese Version of the Oral Health Impact Profile for Edentulous Subjects. J Prosthodont. 2018, 27, 416–420. [Google Scholar] [CrossRef] [PubMed]
  47. Kimoto, S.; Kimoto, K.; Gunji, A.; Kawai, Y.; Murakami, H.; Tanaka, K.; Syu, K.; Aoki, H.; Toyoda, M.; Kobayashi, K. Clinical effects of acrylic resilient denture liners applied to mandibular complete dentures on the alveolar ridge. J. Oral Rehabil. 2007, 34, 862–869. [Google Scholar] [CrossRef] [PubMed]
  48. Beck, C.; Bates, J.; Basker, R.; Gutteridge, D.; Harrison, A. A survey of the dissatisfied denture patient. Eur. J. Prosthodont. Restor. Dent. 1993, 2, 73–78. [Google Scholar]
  49. Kimoto, S.; Furuse, N.; Ogawa, T.; Nakashima, Y.; Furokawa, S.; Okubo, M.; Yamaguchi, H.; Kawai, Y. Receptivity of the mandible versus the maxilla to external stimuli in patients with complete dentures. J. Prosthodont. Res. 2019, 63, 299–302. [Google Scholar] [CrossRef]
  50. Shinogaya, T.; Sodeyama, A.; Matsumoto, M. Bite force and occlusal load distribution in normal complete dentitions of young adults. Eur. J. Prosthodont. Restor. Dent. 1999, 7, 65–70. [Google Scholar]
  51. Tortopidis, D.; Lyons, M.F.; Baxendale, R.H.; Gilmour, W.H. The variability of bite force measurement between sessions, in different positions within the dental arch. J. Oral Rehabil. 1998, 25, 681–686. [Google Scholar] [CrossRef] [PubMed]
  52. Fontijn-Tekamp, F.A.; Slagter, A.P.; Van Der Bilt, A.; Van’T Hof, M.A.; Witter, D.J.; Kalk, W.J.J.A.; Jansen, J.A. Biting and chewing in overdentures, full dentures, and natural dentitions. J. Dent. Res. 2000, 79, 1519–1524. [Google Scholar] [CrossRef] [PubMed]
  53. Furokawa, S.; Kimoto, S.; Furuse, N.; Furuya, Y.; Ogawa, T.; Nakashima, Y.; Okubo, M.; Yamaguchi, H.; Kawai, Y. The effects of silicone-based resilient denture liners on pain: A randomized controlled trial. J. Prosthodont. Res. 2020, 64, 417–423. [Google Scholar] [CrossRef] [PubMed]
  54. Kimoto, S.; So, K.; Yamamoto, S.; Ohno, Y.; Shinomiya, M.; Ogura, K.; Kobayashi, K. Randomized controlled clinical trial for verifying the effect of silicone-based resilient denture liner on the masticatory function of complete denture wearers. Int. J. Prosthodont. 2006, 19, 593–600. [Google Scholar] [PubMed]
Figure 1. Participants’ flow chart of the study.
Figure 1. Participants’ flow chart of the study.
Jcm 12 02073 g001
Table 1. Baseline characteristics of the study participants.
Table 1. Baseline characteristics of the study participants.
VariableAcrylic-Based SL Group
(n = 14)
Silicone-Based SL Group
(n = 14)
Age (years), mean ± SD60.1 ± 12.458.7 ± 13.1
Edentulous period (mandible) (years), mean ± SD5.9 ± 2.36.4 ± 1.8
Height of alveolar ridge (mm), mean ± SD 16.9 ± 4.217.6 ± 3.3
Mucosal thickness (mm), mean ± SD1.9 ± 0.72.2 ± 0.2
Mucosal resiliency (firm, resilient, flappy)(10, 4, 0)(9, 5, 0)
Denture difficulty classification (I, II, III, IV)(6, 7, 1, 0)(7, 6, 1, 0)
SL, soft liner; SD, standard deviation; mm, millimeter.
Table 2. The overall oral health-related quality of life (Mean ± SD) at baseline and one and three months after denture reline.
Table 2. The overall oral health-related quality of life (Mean ± SD) at baseline and one and three months after denture reline.
InterventionsBaselineOne MonthThree Months
Acrylic-Based SL56.3 ± 8.2 Aa34.6 ± 7.8 Bb29.4 ± 5.9 Bb
Silicone-Based SL53.1 ± 12.8 Aa31.9 ± 7.4 Bb25.8 ± 6.2 Bb
MD (CI)−3.2 (−11.5 to 5.1)−2.7 (−8.6 to 3.2)−3.6 (−8.3 to 1.1)
A, B: significant statistical differences can be found in values with dissimilar capital letters in columns (between groups). a, b: significant statistical differences exist between values with dissimilar small letters in rows (between time intervals); MD, mean difference; CI, confidence interval.
Table 3. Pain perception (Mean ± SD) rating on the 100-mm VAS.
Table 3. Pain perception (Mean ± SD) rating on the 100-mm VAS.
InterventionsBaseline (Before Relining)At the Time of the Initial Adjustment
Acrylic-Based SL63.5 ± 29.8 Aa47.1 ± 34.9 Bb
Silicone-Based SL61.1 ± 31.1 Aa45.9 ± 36.1 Bb
MD (CI)−2.4 (−26.1 to 21.2)−1.2 (−28.8 to 26.3)
A, B; significant statistical differences can be found in values with dissimilar capital letters in columns (between groups). a, b; significant statistical differences exist between values with dissimilar small letters in rows (between time intervals); MD, mean difference; CI, confidence interval.
Table 4. Maximum bite force in Newtons (Mean ± SD) at baseline; 1, 2, and 3 months after denture adjustment.
Table 4. Maximum bite force in Newtons (Mean ± SD) at baseline; 1, 2, and 3 months after denture adjustment.
InterventionsBaselineOne MonthThree Months
Acrylic-Based SL75 ± 31 Aa145 ± 53 Bb116 ± 47 Bc
Silicone-Based SL83 ± 32 Aa156 ± 49 Bb166 ± 57 Cb
MD (CI)8 (−16.4 to 32.4)11 (−28.6 to 50.6)50 (9.4 to 60.5)
A, B, and C: significant statistical differences can be found in values with dissimilar capital letters in columns (between groups); a, b, and c: significant statistical differences exist between values with dissimilar small letters in rows (between time intervals); MD, mean difference; CI, confidence interval.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Alqutaibi, A.Y.; Alnazzawi, A.A.; Farghal, A.E.; Bakr, R.M.; Mahmoud, I.I. Impact of Acrylic and Silicone-Based Soft-Liner Materials on Biting Force and Quality of Life of the Complete Denture Wearers: A Randomized Clinical Trial. J. Clin. Med. 2023, 12, 2073. https://doi.org/10.3390/jcm12052073

AMA Style

Alqutaibi AY, Alnazzawi AA, Farghal AE, Bakr RM, Mahmoud II. Impact of Acrylic and Silicone-Based Soft-Liner Materials on Biting Force and Quality of Life of the Complete Denture Wearers: A Randomized Clinical Trial. Journal of Clinical Medicine. 2023; 12(5):2073. https://doi.org/10.3390/jcm12052073

Chicago/Turabian Style

Alqutaibi, Ahmed Yaseen, Ahmad A. Alnazzawi, Ahmed E. Farghal, Ramy M. Bakr, and Ihab Ismail Mahmoud. 2023. "Impact of Acrylic and Silicone-Based Soft-Liner Materials on Biting Force and Quality of Life of the Complete Denture Wearers: A Randomized Clinical Trial" Journal of Clinical Medicine 12, no. 5: 2073. https://doi.org/10.3390/jcm12052073

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop