Next Article in Journal
Preeclampsia Management and Maternal Ophthalmic Artery Doppler Measurements between 19 and 23 Weeks of Gestation
Previous Article in Journal
Impact of Cardiac Magnetic Resonance on the Diagnosis of Left Ventricular Noncompaction—A 15-Year Experience
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Concentrations of Cobalt, Chromium and Titanium and Immunological Changes after Primary Total Knee Arthroplasty—A Cohort Study with an 18-Year Follow-Up

Orthopaedics—Department of Surgical Sciences, Uppsala University, SE-751 85 Uppsala, Sweden
*
Author to whom correspondence should be addressed.
J. Clin. Med. 2024, 13(4), 951; https://doi.org/10.3390/jcm13040951
Submission received: 28 December 2023 / Revised: 2 February 2024 / Accepted: 5 February 2024 / Published: 7 February 2024
(This article belongs to the Section Orthopedics)

Abstract

:
Background: Total knee arthroplasty (TKA) generates elevated metal ion concentrations, but long-term changes in the concentrations of cobalt (Co), chromium (Cr) and titanium (Ti) after primary TKA and potential subsequent immune system activation—not limited to the joint but systemically—are not known. Patients and Methods: We conducted a cohort study on 26 patients with TKA (19 women; 16 with metal-backed and 10 with all-polyethylene tibial components) 18.3 years (min. 16.7, max. 20.5) after index TKA. A total of 69% of patients additionally underwent subsequent arthroplasty of the contralateral knee or either hip after the index surgery. Blood samples were analysed by inductively coupled plasma–mass spectrometry, and leukocytes were characterised by flow cytometry. Patients were clinically assessed using the Knee Society score and by plain radiography of the knee. Results: The median metal ion concentrations were 0.7 (0.1–13.0) µg/L for Co, 0.9 (0.4–5.0) µg/L for Cr, and 1.0 (0.2–13.0) µg/L for Ti. There was no relevant difference in systemic metal ion concentrations between patients exposed to single and multiple arthroplasties. The absolute count and proportion of CD3+CD4+CD8+ T cells was inversely correlated with both Co (rho −0.55, p = 0.003) and Cr concentrations (rho −0.59, p = 0.001). Conclusions: Between the first and second decades after primary TKA, in most patients, the concentrations of Co, Cr and Ti in blood samples were below the thresholds that are considered alarming. The negative correlation of Co and Cr concentrations with a subset of lymphocytes that commonly increases during immune activation is reassuring. This represents a worst-case scenario, underscoring that the investigated metal ions remain within reasonable ranges, even after additional hardware exposure.

1. Introduction

Patients with metal-on-metal hip arthroplasty can be asymptomatic despite elevated metal ion concentrations; thus, the active monitoring of exposed patients by conducting measurements of whole blood concentrations of cobalt (Co) and chromium (Cr) is recommended [1]. Several national guidelines, including the Swedish ones, define thresholds between 2 and 3 μg/L as the upper limit for these ions [2]. Implants designed for primary total knee arthroplasty (TKA) usually have no metal-on-metal articulation, and guidelines for the follow-up of TKA do not regularly include the measurements of metal ion concentrations. However, the classification of Co as potentially carcinogenic by the European Union has instigated renewed interest in the possible consequences of exposure to Co in TKA patients [3].
Elevated metal ion concentrations are described in the early years after primary TKA. Co and Cr concentrations of 0.3 μg/L and 0.6 μg/L were found one year after the insertion of standard metal-backed TKA, with no Co measurement above 1 μg/L [4]. In a different study including baseline data, Co concentrations are described to be unchanged when compared with pre-operative measurements one year after conventional TKA [5]. In the short term, the reported concentrations after primary TKA are, thus, far below those found after hip resurfacing, and below the safety thresholds that have been defined in the context of metal-on-metal hip arthroplasty.
No long-term investigation of metal ion concentrations after TKA and no analysis of immune system alterations after the insertion of a TKA is known to us. The present study therefore aims to (1) analyse the blood concentrations of Co, Cr and Ti, the three major metals constituting alloys commonly used in TKA designs, at least one decade after index surgery, and (2) to assess whether changes in lymphocyte subsets as a sign of any systemic immunological activation are correlated with blood metal ion concentrations.

2. Patients and Methods

2.1. Study Design and Participants

This is an observational cohort study on patients who underwent a cemented TKA between the years 1994 and 1997 and who were included in three different randomised studies. The first cohort (40 patients) received a Freeman–Samuelson (FS) knee prosthesis with either all-polyethylene (n = 20) or metal-backed (n = 20) tibial components, all cemented with Palacos (Heraeus, Hanau, Germany). The second cohort (40 patients) received an AGC (Anatomical Graduated Component) knee prosthesis with either all-polyethylene (n = 20) or metal-backed (n = 20) tibial components, using Palacos bone cement. The remaining 51 patients (the third cohort) received an AMK (Anatomic Modular Knee) prosthesis with a metal-backed tibial component; in this subgroup, half the prostheses were cemented with CMW-1 (DePuy Synthes, Raynham, MA, USA, n = 26) and the other half with Palacos (n = 25). The primary outcome of all studies was implant migration, as measured by radiostereometry. At the time of this long-term follow-up, 52 patients were still alive, of whom a total of 26 patients were available for clinical examination; the remaining 26 declined to participate or were unfit to attend outpatient visits. Thus, of the twenty-six patients attending follow-up, nine patients had received an AGC TKA (four all-polyethylene, five metal-backed tibial components), ten patients had received an FS TKA (six all-polyethylene, four metal-backed tibial components), and the remaining seven patients had received the AMK TKA (only metal-backed tibial components).

2.2. Metal Ion Analysis

Blood samples were collected in two 10 mL EDTA anti-coagulated trace-metal-free tubes by a registered nurse using an 18-gauge intravenous cannula, with the central stainless-steel needle removed. The first tube was used for immunological analysis, and the second for determining the metal ion concentration in order to reduce the potential for metal ion contamination, but no further measures were undertaken to control for contamination. The vial for the metal analysis ion was sent to an accredited external laboratory specialising in trace metal analysis (ALS AB, Luleå, Sweden). The samples were dissolved in HNO3 in a microwave oven. They were then analysed for Cr, Co and Ti using inductively coupled plasma—mass spectrometry (ICP-MS) according to SS EN ISO17294-1, 2. The detection limits for the individual elements were 0.05 µg/L for Co, 0.2 µg/L for Cr, and 0.05 µg/L for titanium, all measurements below the detection limit were set equal to the detection limit, and all ion concentrations are presented in μg/L.

2.3. Immunological Analysis

Immunological analysis was performed by flow cytometry at Uppsala University Hospital using commercially available antibodies (CD3, CD8, CD45, CD4: Tetrachrome Beckman Coulter, Bromma, Sweden, cat. No. 6607013; CD3, CD 16/56, CD45, CD19: Tetrachrome, cat. No. 332779; HLA DR: Becton Dickinson, cat. No. 6604366; CD4: Becton-Dickinson, cat. No. 345768; CD8: Dako, cat. No. C7079). Results are given as numbers per nL, as percentages or as ratios where applicable.

2.4. Clinical and Radiographic Assessment

All analysed patients were evaluated according to the clinical scoring systems of the Knee Society [6]. This assessment consists of two parts: the knee score assessing knee function with respect to pain, stability and range of motion, and the function score assessing maximum walking distance, the ability to climb stairs and the need for walking aids. Plain radiography of the knee with anterior–posterior and lateral views was performed, and these were assessed for aseptic loosening. These evaluations were independently performed by two observers (A.G. and N.P.H.).

2.5. Ethics

Uppsala Ethics Committee approved both the three original randomised trials that the study participants were originally included in (approval number 104/93) and the long-term follow-up of the cohort described here (approval number 2012/013, date of approval: 14 May 2012). An additional approval was requested and granted by the Swedish Ethical Review Authority to perform a medical chart review of all included patients in order to ascertain the presence or absence of additional TKA or total hip arthroplasty (approval number: 2022-00905-02, date of approval: 2 March 2022). The research described here followed the updated version of the Helsinki declaration.

2.6. Statistical Analysis

Data distributions were visualised using histograms and analysed for normality through visual inspection of the histograms and density functions. Metal ion measurements, lymphocyte counts and proportions, and knee scores deviated considerably from normal distributions; therefore, medians, ranges and interquartile ranges (IQR) were used to describe these data. The non-parametric Wilcoxon–Mann–Whitney U-test was used to compare groups, and Spearman’s rho statistic was calculated to investigate correlations. R version 3.6.1 statistical software was used for analysis, p-values < 0.05 were considered indicative of statistical significance, and due to the exploratory nature of our study, no multiplicity correction was performed.

3. Results

3.1. Characteristics of the Study Population

The study population consisted of 26 patients (19 women) with a mean age at surgery of 65.3 years (SD 5.3; Table 1). This cohort of 26 patients was derived from two separate randomised controlled trials that compared metal-backed with all-polyethylene designs (either of the AGC or FS brand), or from a third randomised controlled trial from the same decade that compared two types of cement used in TKA surgery (CMW-1 with Palacos; see Section 2). The presence of both metal-backed (n = 16) and all-polyethylene tibial components (n = 10) permitted us to perform subgroup analyses on patients, comparing these two different tibial component designs with respect to metal ion concentrations. Eighteen patients (69%) had received either a contralateral TKA (n = 2) or a conventional total hip arthroplasty (THA) with a metal head articulating with a polyethylene liner.

3.2. Metal Ion Concentrations

The median Co concentration in the entire cohort was 0.7 (IQR: 0.89, range: 0.1–13.0) µg/L. When divided by the type of tibial component, the median Co concentrations were slightly lower among patients with all-polyethylene than among those with metal-backed tibial components, but the difference was not statistically significant (Table 2).
The median Cr concentration in the entire cohort was 0.9 (IQR: 0.85, range: 0.4–5) µg/L. As for Co concentrations, the median Cr concentrations were slightly but not statistically significantly lower among patients with all-polyethylene than among those with metal-backed tibial components (Table 2).
The median concentration of Ti in the pooled cohort was 1 (IQR: 0.63, range: 0.2–13) µg/L. The median Ti concentration in patients with all-polyethylene tibial components was slightly lower than in those with metal-backed, although the maximal Ti concentration (13 µg/L) was found in a patient with an all-polyethylene component. There was no statistically significant difference in Ti concentrations between these two groups (Table 2).
The concentrations of Co and Cr correlated strongly with each other (rho 0.69, p < 0.001). In contrast, we observed no correlations between Co and Ti (rho −0.073, p = 0.7) or between Cr and Ti (rho 0.1, p = 0.6).
Since the majority of patients had received additional arthroplasties in other joints, we compared metal ion concentrations in those with singular and those with multiple arthroplasties, but found no statistically significant differences for any of the investigated ions. However, the maximum Co and Ti concentrations were found in the group of patients with multiple arthroplasties (Table 3).

3.3. Immunological Analyses

The counts and relative proportions of the measured lymphocyte subsets were within the normal ranges, according to local reference values (Table 4). When analysing potential correlations between lymphocyte counts or concentrations and metal ion concentrations, we found a statistically significant, negative correlation between the absolute count and the proportion of CD3+CD4+CD8+ cells with Co concentration (rho −0.55, p = 0.0034 for the absolute count). Similarly, we observed a negative correlation of the absolute count and the proportion of CD3+CD4+CD8+ cells with Cr concentrations (rho −0.59, p = 0.0014 for the absolute count). There were some other statistically significant negative correlations between lymphocyte subsets, on the one hand, and Co concentrations on the other hand (Table 3). We then investigated whether the subsets of lymphocytes differed between patients with all-polyethylene and metal-backed tibial components, and found some with statistically significant differences between groups (absolute leukocyte count, CD3+, CD3+CD4+, CD3+CD4+CD8+, CD45+, DR/CD4+; Table 5).

3.4. Clinical and Radiographic Findings

The median knee score was 83.5 (50–100; IQR 12) and the median function score was 75.0 (0–100; IQR 45). When divided by the type of tibial component, no statistically significant differences between groups were seen. Radiographic signs of loosening in the form of radiolucent lines under the tibial component were found in only one patient, but this patient was asymptomatic.

4. Discussion

4.1. Principal Findings

Our main finding is that Co and Cr concentrations in the blood are slightly—yet not harmfully—elevated almost two decades after TKA, regardless of exposure to subsequent arthroplasties in the hip or knee. With very few exceptions, the concentrations of these ions are well below the thresholds that have been defined as potentially dangerous in the context of metal-on-metal hip arthroplasty. Ti concentrations are also slightly elevated, but lower than the concentrations that are found a decade after cementless total hip arthroplasty. No signs of immune cell activation are observed in our cohort.

4.2. Agreement and Disagreement with Other Studies

The increased concentration of Co and Cr in patients with metal-on-metal articulations in the short term is a known phenomenon [7]. Even a decade after metal-on-metal hip arthroplasty, Co concentrations seem to remain unchanged, whereas Cr concentrations may slightly decline [8]. In some metal-on-metal hip devices, however, Co also declines after ten years [9]. By definition, our cross-sectional study design provides no longitudinal data, but extrapolation from studies on metal ion concentrations after TKA measured at short-term follow-up [4,5] indicates that there is no gross accumulation of metal ions in the long term after TKA.
The pathogenesis of elevated metal ion concentrations after TKA is a combination of corrosion and wear, as found in a study of about 50 CoCr-alloy femoral TKA components retrieved after a mean period of 18 years after index surgery [10]. Almost all investigated implants from five major manufacturers showed signs of abrasive third body wear, and hence, most metal ion release can be considered to be due to third-body wear, but other mechanisms such as electrolysis may contribute as well.
Some hinged TKA designs that are used in revision surgery have a hinge mechanism that includes a metal-on-metal bearing. Co and Cr concentrations far above the commonly agreed threshold of 2 μg/L are described around two years after the use of certain hinged TKA, with maximal values up to 69 μg/L [11]. In a different study on hinged TKA, Co concentrations above 5 μg/L are reported to be present in the majority of investigated patients at a mean follow-up of three years, and Cr levels are also elevated [12].
The development of local or systemic Ti concentrations after TKA is much less investigated, although contemporary TKA designs contain Ti in the tibial baseplate. In studies both on cementless and cemented TKA, median Ti concentrations around 1 μg/L are reported one year after index surgery [4,13]. This can be compared to one of very few studies following Ti concentrations after total hip arthroplasty, where peak values of almost 3 µg/L are described three years after index surgery [14]. Another study on a small cohort of patients with various Ti implants, but no TKA, describes Ti concentrations ranging from 2 to 6 µg/L [15]. Exceptionally high Ti concentrations in the context of TKA are only described in a study including a small subgroup of patients with failed patellar components [16]. The median Ti concentrations found in our cohort are thus at the lower end of the previously described concentration ranges. Of note, compared to Co or Cr, Ti is generally considered relatively inert, but in the context of total hip arthroplasty with CoCr modular neck junctions and bearings other than metal-on-metal, Ti particles seem to be colocalised with Co and Cr nanoparticles [17]. Importantly, the use of all-polyethylene tibial components in TKA avoids exposure to Ti, and this concept has proven to be fairly successful, as indicated by a large Swedish arthroplasty register study [18].
An adverse reaction to metal debris (ARMD) is a common phenomenon after hip resurfacing or total hip arthroplasty using large metal-on-metal articulations. Elevated metal ion concentrations can affect the immune system, which may explain some of the local, peri-articular phenomena observed in the context of metal-on-metal devices in the hip, including the development of ARMD and pseudotumours [19,20]. ARMD associated with the corrosion of modular TKA has been reported [21], and the development of ARMD or even local pseudotumours has been described in a large series of revision TKAs [22]. However, these authors did not report on potential systemic immune reactions related to the development of peri-articular ARMD.
As in the occurrence of ARMD after hip resurfacing, the basic pathophysiological principle of systemic immune activation should be applicable even after TKA, and our study seems to be the first to investigate this topic of systemic immune cell activation after TKA. We fail to detect said activation, yet observe some statistically significant differences in lymphocyte subpopulations between patients with all-polyethylene and metal-backed tibial components. Given the multiplicity of tests performed in this study, this finding may represent a Type-I error. Considering the relatively small numbers of patients in each subgroup, we refrain from speculating as to whether the presence or absence of Ti may have affected lymphocyte subsets. Nonetheless, the finding is interesting and merits further investigations on larger cohorts.
The classification of Co as potentially carcinogenic to humans that was issued by the European commission in 2021 has raised world-wide concerns related to the risk of developing cancer after exposure to orthopaedic implants. However, large-scale register studies indicate no increased overall risk of cancer in patients exposed to total hip arthroplasty [23,24,25], and meta-analyses including occupational exposure to Co also fail to uncover increased risks of cancer [26]. While this is reassuring to both patients with implanted hip and knee replacements and their care givers, it does not exclude the possibility of effects on the immunological or nervous system in vivo. Hence, studies such as the present work are of importance to investigate any possible association between elevated metal ion concentrations and systemic effects.

4.3. Strengths and Weaknesses of This Study

Our study is limited by numerous weaknesses. First of all, measurements of metal ion concentrations and immunological alterations were not part of the primary or secondary outcome measures of the original trial designs, and the sample sizes were consequently not adequate to investigate these research questions. We also lack baseline data on metal ion concentrations, further limiting our conclusions. The availability of only 26 of the original 116 patients raises concerns related to selection bias, and the deceased patients and those not willing or able to attend clinical follow-up who were excluded from our analyses might have had the highest metal ion concentrations. The absence of biopsies, and hence, the inability to perform histological examinations in our study, prevents us from drawing conclusions on the absence or presence of a lymphocytic infiltrate in the local tissue reaction to wear debris.
The presence of multiple arthroplasties in about two thirds of our patients is a considerable limitation. Nonetheless, with a minimum follow-up of 17 years after the index TKA, this is not entirely surprising when considering the systemic character of osteoarthritis [27]. Only two of the patients in our cohort were exposed to another TKA, and the remaining 16 had THA implants; however, they were only metal-on-polyethylene articulations. We recognise that this may distort our metal ion measurements and the correlated changes in lymphocyte subsets. Yet, we consider the influence of additional hip implants to be of minor influence. Co and Cr concentrations in patients with metal-on-polyethylene THA are low 16 years after THA, with Co measured at 0.4 µg/L and Cr at 1.0 µg/L [28]. One may also argue that our findings represent a worst-case scenario: two thirds of our patients were exposed to an arthroplasty, mostly THA, in addition to the TKA that was our primary interest. Nonetheless, their metal ion concentrations are far from the range of those found in patients exposed to metal-on-metal THA or hinged revision TKA.
Our assessment of Ti concentrations using ICP-MS rather than inductively coupled plasma–optical emission spectroscopy (ICP-OES) is in accordance with current recommendations [29]. Our data description uses medians and statistical inference is based on non-parametric methods, which also complies with recommendations on the interpretation of Ti measurements that are referred to above.
An important strength of our study is the long-term follow-up of both metal ion concentrations and immunological parameters in a well-defined population of primary TKA patients. None of the cited studies on the topic of metal ion exposure after TKA addresses this issue that is well characterised after THA, both in patients with conventional metal-on-polyethylene articulations and in those with metal-on-metal devices.

5. Conclusions

Our study indicates that patients who have been exposed to TKA for almost two decades have low blood concentrations of Co, Cr and Ti, even when exposed to additional arthroplasties in the hip or knee joint. This is an important finding since the classification of Co as a potentially cancerogenic substance has raised concerns, both among patients and orthopaedic surgeons, related to potential cancer risks after TKA. Secondly, a note of caution remains around a few patients with Co and Cr concentrations above the reference values defined for hip arthroplasty patients. Thirdly, patients in our cohort fail to show signs of immunological activation that have been previously described in the context of metal ion exposure after hip arthroplasty, which is also a reassuring finding.

Author Contributions

A.B.: Data Curation; Formal Analysis; Investigation; Methodology; Software; Visualisation; Writing—Review and Editing. N.P.H.: Conceptualisation; Funding Acquisition; Investigation; Methodology; Project Administration; Resources; Supervision; Writing—Original Draft, Review and Editing. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by grants from the Swedish Research Council [grant number 2021-00980] and “Stiftelsen Promobilia” [grant number A23003] to N.P.H.

Institutional Review Board Statement

Uppsala Ethics Committee approved both the three original randomised trials that the study participants were originally included in (approval number 104/93) and the long-term follow-up of the cohort described here (approval number 2012/013, date of approval: 14 May 2012). An additional approval was requested and granted by the Swedish Ethical Review Authority to perform a medical chart review of all included patients in order to ascertain the presence or absence of additional TKA or total hip arthroplasty (approval number: 2022-00905-02, date of approval: 2 March 2022). The research described here followed the updated version of the Helsinki declaration.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Due to Swedish legislation data on individual patients may not be shared. Upon reasonable request and approval by the Ethical Review Authority aggregated data may be shared.

Acknowledgments

Gunnar Adalberth is acknowledged for conducting the original clinical trials in which the patients investigated in this long-term follow-up were enrolled. Asgeir Gudnason and Elias Jaenson are acknowledged for their help in conducting the long-term follow-up of the study cohort.

Conflicts of Interest

Nils P. Hailer has received institutional grants and lecturer’s fees from Waldemar Link GmbH, Zimmer Biomet and Heraeus Medical, and institutional grants from Zimmer Biomet.

References

  1. Scientific Committee on Emerging and Newly Identified Health Risks (CENIHR). The Safety of Metal-on-Metal Joint Replacements with a Particular Focus on Hip Implants; European Commission: Luxembourg, 2014.
  2. Knäföreningen, S.H.-O. Uppföljning Av Metall-Mot-Metall-Proteser I Sverige. 2023. Available online: https://slf.se/sof/app/uploads/2020/11/shkf-ytis-riktlinjer-120516001.pdf (accessed on 10 June 2023).
  3. European Union. Medical Device Regulation. In Europeiska Unionens Officiella Tidning; European Union: Brussel, Belgium, 2017. [Google Scholar]
  4. Reiner, T.; Sorbi, R.; Müller, M.; Nees, T.; Kretzer, J.P.; Rickert, M.; Moradi, B. Blood Metal Ion Release after Primary Total Knee Arthroplasty: A Prospective Study. Orthop. Surg. 2020, 12, 396–403. [Google Scholar] [CrossRef]
  5. Postler, A.; Beyer, F.; Lutzner, C.; Tille, E.; Lutzner, J. Similar outcome during short-term follow-up after coated and uncoated total knee arthroplasty: A randomized controlled study. Knee Surg. Sports Traumatol. Arthrosc. 2018, 26, 3459–3467. [Google Scholar] [CrossRef]
  6. Insall, J.N.; Dorr, L.D.; Scott, R.D.; Scott, W.N. Rationale of the Knee Society clinical rating system. Clin. Orthop. Relat. Res. 1989, 248, 13–14. [Google Scholar] [CrossRef]
  7. Dahlstrand, H.; Stark, A.; Anissian, L.; Hailer, N.P. Elevated Serum Concentrations of Cobalt, Chromium, Nickel, and Manganese After Metal-On-Metal Alloarthroplasty of the Hip: A Prospective Randomized Study. J. Arthroplast. 2009, 24, 837–845. [Google Scholar] [CrossRef] [PubMed]
  8. Pietilainen, S.; Smedberg, E.; Laaksonen, I.; Venalainen, M.S.; Lankinen, P.; Makela, K.T. Repeated metal ion measurements and long-term outcome of Durom/MMC total hip arthroplasty. Acta Orthop. 2022, 93, 241–248. [Google Scholar] [CrossRef] [PubMed]
  9. Pietilainen, S.; Linnovaara, A.; Venalainen, M.S.; Mäntymäki, H.; Laaksonen, I.; Lankinen, P.; Mäkelä, K.T. Median 10-year whole blood metal ion levels and clinical outcome of ReCap-M2a-Magnum metal-on-metal total hip arthroplasty. Acta Orthop. 2022, 93, 444–450. [Google Scholar] [CrossRef] [PubMed]
  10. Arnholt, C.M.; MacDonald, D.W.; Malkani, A.L.; Klein, G.R.; Rimnac, C.M.; Kurtz, S.M.; Kocagoz, S.B.; Gilbert, J.L. Corrosion Damage and Wear Mechanisms in Long-Term Retrieved CoCr Femoral Components for Total Knee Arthroplasty. J. Arthroplast. 2016, 31, 2900–2906. [Google Scholar] [CrossRef] [PubMed]
  11. Gramlich, Y.; Hofmann, L.; Kress, S.; Ruckes, C.; Kemmerer, M.; Klug, A.; Hoffmann, R.; Kremer, M. Critically high metal ion levels found in metal-on-metal modular hinged knee arthroplasty: A comparison of two different systems. Bone Jt. J. 2022, 104, 376–385. [Google Scholar] [CrossRef] [PubMed]
  12. Laitinen, M.; Nieminen, J.; Reito, A.; Pakarinen, T.-K.; Suomalainen, P.; Pamilo, K.; Parkkinen, J.; Lont, T.; Eskelinen, A. High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements. Acta Orthop. 2017, 88, 269–274. [Google Scholar] [CrossRef] [PubMed]
  13. Swiatkowska, I.; Martin, N.G.; Henckel, J.; Apthorp, H.; Hamshere, J.; Hart, A.J. Blood and plasma titanium levels associated with well-functioning hip implants. J. Trace Elem. Med. Biol. 2019, 57, 9–17. [Google Scholar] [CrossRef] [PubMed]
  14. Levine, B.R.; Hsu, A.R.; Skipor, A.K.; Hallab, N.J.; Paprosky, W.G.; Galante, J.O.; Jacobs, J.J. Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: A concise follow-up of a previous report. J. Bone Jt. Surg. Am. 2013, 95, 512–518. [Google Scholar] [CrossRef] [PubMed]
  15. Balcaen, L.; Bolea-Fernandez, E.; Resano, M.; Vanhaecke, F. Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS. Anal. Chim. Acta 2014, 809, 1–8. [Google Scholar] [CrossRef] [PubMed]
  16. Jacobs, J.J.; Silverton, C.; Hallab, N.J.; Skipor, A.K.; Patterson, L.; Black, J.; Galante, J.O. Metal release and excretion from cementless titanium alloy total knee replacements. Clin. Orthop. Relat. Res. 1999, 358, 173–180. [Google Scholar] [CrossRef]
  17. Xia, Z.; Ricciardi, B.F.; Liu, Z.; von Ruhland, C.; Ward, M.; Lord, A.; Hughes, L.; Goldring, S.R.; Purdue, E.; Murray, D.; et al. Nano-analyses of wear particles from metal-on-metal and non-metal-on-metal dual modular neck hip arthroplasty. Nanomedicine 2017, 13, 1205–1217. [Google Scholar] [CrossRef] [PubMed]
  18. Gudnason, A.; Hailer, N.P.; Annette, W.; Sundberg, M.; Robertsson, O. All-Polyethylene Versus Metal-Backed Tibial Components—An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register. J. Bone Jt. Surg. Am. 2014, 96, 994–999. [Google Scholar] [CrossRef]
  19. Hailer, N.P.; Blaheta, R.A.; Dahlstrand, H.; Stark, A. Elevation of circulating HLA DR+ CD8+ T-cells and correlation with chromium and cobalt concentrations 6 years after metal-on-metal hip arthroplasty. Acta Orthop. 2011, 82, 6–12. [Google Scholar] [CrossRef]
  20. Hallab, N.J.; Caicedo, M.; McAllister, K.; Skipor, A.; Amstutz, H.; Jacobs, J.J. Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J. Orthop. Res. 2013, 31, 173–182. [Google Scholar] [CrossRef]
  21. Christiner, T.; Pabbruwe, M.B.; Kop, A.M.; Parry, J.; Clark, G.; Collopy, D. Taper Corrosion and Adverse Local Tissue Reactions in Patients with a Modular Knee Prosthesis. JBJS Open Access 2018, 3, e0019. [Google Scholar] [CrossRef]
  22. Kurmis, A.P.; Herman, A.; McIntyre, A.R.; Masri, B.A.; Garbuz, D.S. Pseudotumors and High-Grade Aseptic Lymphocyte-Dominated Vasculitis-Associated Lesions Around Total Knee Replacements Identified at Aseptic Revision Surgery: Findings of a Large-Scale Histologic Review. J. Arthroplast. 2019, 34, 2434–2438. [Google Scholar] [CrossRef]
  23. Hailer, N.P.; Garland, A.; Gordon, M.; Kärrholm, J.; Sköldenberg, O.; Eriksson, N.; Garmo, H.; Holmberg, L. No generally increased risk of cancer after total hip arthroplasty performed due to osteoarthritis. Int. J. Cancer 2020, 147, 76–83. [Google Scholar] [CrossRef]
  24. Hailer, Y.D.; Karrholm, J.; Eriksson, N.; Holmberg, L.; Hailer, N.P. Similar risk of cancer in patients younger than 55 years with or without a total hip arthroplasty (THA): A population- based cohort study on 18,771 exposed to THA and 87,683 controls. Acta Orthop. 2022, 93, 317–326. [Google Scholar] [CrossRef] [PubMed]
  25. Deere, K.; Matharu, G.S.; Ben-Shlomo, Y.; Wilkinson, J.M.; Blom, A.W.; Sayers, A.; Whitehouse, M.R. The risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders with cobalt-chrome-containing total hip arthroplasty implants: An analysis of the National Joint Registry. Bone Jt. J. 2022, 104, 359–367. [Google Scholar] [CrossRef] [PubMed]
  26. Holy, C.E.; Zhang, S.; Perkins, L.E.; Hasgall, P.; Katz, L.B.; Brown, J.R.; Orlandini, L.; Fessel, G.; Nasseri-Aghbosh, B.; Eichenbaum, G.; et al. Site-specific cancer risk following cobalt exposure via orthopedic implants or in occupational settings: A systematic review and meta-analysis. Regul. Toxicol. Pharmacol. 2021, 129, 105096. [Google Scholar] [CrossRef] [PubMed]
  27. Hunter, D.J.; Bierma-Zeinstra, S. Osteoarthritis. Lancet 2019, 393, 1745–1759. [Google Scholar] [CrossRef]
  28. Dahlstrand, H.; Stark, A.; Wick, M.C.; Anissian, L.; Hailer, N.P.; Weiss, R.J. Comparison of metal ion concentrations and implant survival after total hip arthroplasty with metal-on-metal versus metal-on-polyethylene articulations. Acta Orthop. 2017, 88, 490–495. [Google Scholar] [CrossRef]
  29. Yao, J.J.; Lewallen, E.A.; Thaler, R.; Dudakovic, A.; Wermers, M.; Day, P.; Eckdahl, S.; Jannetto, P.; Bornhorst, J.A.; Larson, A.N.; et al. Challenges in the Measurement and Interpretation of Serum Titanium Concentrations. Biol. Trace Elem. Res. 2020, 196, 20–26. [Google Scholar] [CrossRef]
Table 1. Characteristics of the study population, first divided by those who received all-polyethylene or metal-backed tibial components, and then, summarised (Overall). Numbers indicate n and percentages (in parentheses) unless otherwise stated.
Table 1. Characteristics of the study population, first divided by those who received all-polyethylene or metal-backed tibial components, and then, summarised (Overall). Numbers indicate n and percentages (in parentheses) unless otherwise stated.
All-Poly
(N = 10)
Metal-Backed
(N = 16)
Overall
(N = 26)
Sex
Male1 (10.0%)6 (37.5%)7 (26.9%)
Female9 (90.0%)10 (62.5%)19 (73.1%)
Side
Right5 (50.0%)12 (75.0%)17 (65.4%)
Left5 (50.0%)4 (25.0%)9 (34.6%)
Age at Surgery
Mean (range)64 (53–73)66 (57–75)65 (53–75)
Follow up [years]
Mean (range)18 (17–19)18 (17–21)18 (17–21)
Table 2. Metal ion measurements performed by ICP-MS (all concentrations in µg/L). Measurements are first divided by patients who received all-polyethylene or metal-backed tibial components, and then, summarised (Overall). * Standard deviation.
Table 2. Metal ion measurements performed by ICP-MS (all concentrations in µg/L). Measurements are first divided by patients who received all-polyethylene or metal-backed tibial components, and then, summarised (Overall). * Standard deviation.
All-Poly
(N = 10)
Metal-Backed
(N = 16)
Overall
(N = 26)
Cobalt
Median (IQR *; range)0.56 (0.35; 0.13–3.2)0.89 (1.1; 0.14–13)0.71 (0.89; 0.13–13)
Chrome
Median (IQR; range)0.62 (0.51; 0.37–1.9)1.0 (1.0; 0.37–5.0)0.91 (0.85; 0.37–5.0)
Titanium
Median (IQR; range)0.42 (0.61; 0.16–13)1.0 (0.38; 0.22–1.7)1.0 (0.63; 0.16–13)
Table 3. Metal ion measurements performed by ICP-MS (all concentrations in µg/L), comparing metal ion concentrations in patients with single vs. multiple arthroplasties. * Total knee arthroplasty; ** interquartile range.
Table 3. Metal ion measurements performed by ICP-MS (all concentrations in µg/L), comparing metal ion concentrations in patients with single vs. multiple arthroplasties. * Total knee arthroplasty; ** interquartile range.
Singular TKA *
(N = 8)
Multiple Arthroplasties
(N = 18)
Overall
(N = 26)
Cobalt
Median (IQR **; range)1.1 (0.49; 0.53–2.7)0.59 (0.50; 0.13–13)0.71 (0.89; 0.13–13)
Chrome
Median (IQR; range)1.3 (0.60; 0.44–5.0)0.62 (0.53; 0.37–3.9)0.91 (0.85; 0.37–5.0)
Titanium
Median (IQR; range)0.46 (0.72; 0.22–1.2)1.0 (0.54; 0.16–13)1.0 (0.63; 0.16–13)
Table 4. Lymphocyte counts per nL, or percentages (%), or ratios, given as medians with ranges, and correlations of these values with cobalt, chromium and titanium concentrations. Rho and p-values are derived from Spearman’s rank correlation.
Table 4. Lymphocyte counts per nL, or percentages (%), or ratios, given as medians with ranges, and correlations of these values with cobalt, chromium and titanium concentrations. Rho and p-values are derived from Spearman’s rank correlation.
Correlations
CobaltChromeTitanium
MedianMin.Max.RhopRhopRhop
Leukocyte count7.654.813−0.180.37−0.260.2−0.320.11
CD3 (%)72.654183−0.040.85−0.050.8−0.120.56
CD31099.53901906−0.360.07−0.230.25−0.30.14
CD3CD8 (%)18.755.138.10.150.470.080.7−0.080.68
CD3CD8341.547.3716−0.070.73−0.070.73−0.070.73
CD3CD4 (%)51.5525.967.3−0.310.12−0.260.2−0.090.66
CD3CD4782.52461446−0.470.02−0.320.11−0.290.15
CD3CD4CD8 (%)1.0150.184.6−0.50.01−0.590.002−0.150.48
CD3CD4CD815.551.7103−0.550.003−0.590.001−0.160.44
CD16CD56 (%)16.857.342.30.140.490.140.49−0.080.68
CD16CD56272.5112609−0.050.820.070.72−0.140.49
CD19 (%)9.12.223−0.080.68−0.120.560.240.24
CD19165.528305−0.330.1−0.280.170.060.77
CD4514969372716−0.390.05−0.250.23−0.280.17
Ratio CD4/CD82.770.9511.13−0.240.23−0.170.41−0.040.84
DR/CD4 (%)3.81.7240.450.030.370.070.370.07
DR/CD8 (%)1.40.1140.210.320.140.50.310.14
Table 5. Differences in lymphocyte populations between patients who received all-polyethylene or metal-backed tibial components. Mann–Whitney U statistics and two-tailed p-values derived from Wilcoxon–Mann–Whitney rank sum test.
Table 5. Differences in lymphocyte populations between patients who received all-polyethylene or metal-backed tibial components. Mann–Whitney U statistics and two-tailed p-values derived from Wilcoxon–Mann–Whitney rank sum test.
VariableMann–Whitney U Statisticp
Leukocyte count1220.03
CD3 (%)1060.18
CD31260.01
CD3CD8 (%)99.50.3
CD3CD81110.1
CD3CD4 (%)98.50.34
CD3CD41210.03
CD3CD4CD8 (%)1140.07
CD3CD4CD81240.02
CD16CD56 (%)730.73
CD16CD561020.26
CD19 (%)540.18
CD19780.94
CD451240.02
Ratio CD4/CD8710.66
DR/CD4 (%)190.002
DR/CD8 (%)520.2
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Brüggemann, A.; Hailer, N.P. Concentrations of Cobalt, Chromium and Titanium and Immunological Changes after Primary Total Knee Arthroplasty—A Cohort Study with an 18-Year Follow-Up. J. Clin. Med. 2024, 13, 951. https://doi.org/10.3390/jcm13040951

AMA Style

Brüggemann A, Hailer NP. Concentrations of Cobalt, Chromium and Titanium and Immunological Changes after Primary Total Knee Arthroplasty—A Cohort Study with an 18-Year Follow-Up. Journal of Clinical Medicine. 2024; 13(4):951. https://doi.org/10.3390/jcm13040951

Chicago/Turabian Style

Brüggemann, Anders, and Nils P. Hailer. 2024. "Concentrations of Cobalt, Chromium and Titanium and Immunological Changes after Primary Total Knee Arthroplasty—A Cohort Study with an 18-Year Follow-Up" Journal of Clinical Medicine 13, no. 4: 951. https://doi.org/10.3390/jcm13040951

APA Style

Brüggemann, A., & Hailer, N. P. (2024). Concentrations of Cobalt, Chromium and Titanium and Immunological Changes after Primary Total Knee Arthroplasty—A Cohort Study with an 18-Year Follow-Up. Journal of Clinical Medicine, 13(4), 951. https://doi.org/10.3390/jcm13040951

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop