Next Article in Journal
Study on the Shear and Bending Mechanical Properties of Millet Stem
Previous Article in Journal
Experimental Warming Reduces the Grain Yield and Nitrogen Utilization Efficiency of Double-Cropping indica Rice in South China
Previous Article in Special Issue
Multi-Scenario Variable-State Robust Fusion Algorithm for Ranging Analysis Framework
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Raising the Drying Unit for Fruits and Vegetables Energy Efficiency by Application of Thermoelectric Heat Pump

Federal Scientific Agroengineering Center VIM, 109428 Moscow, Russia
*
Author to whom correspondence should be addressed.
Agriculture 2024, 14(6), 922; https://doi.org/10.3390/agriculture14060922
Submission received: 23 April 2024 / Revised: 7 June 2024 / Accepted: 9 June 2024 / Published: 11 June 2024
(This article belongs to the Special Issue New Energy-Powered Agricultural Machinery and Equipment)

Abstract

:
Drying food stuffs and other materials belongs to one of the most commonly used feedstock processing techniques, featuring rather high energy consumption. The major disadvantage of conventional electric convective-type household dryers is substantial thermal energy emission into the environment with a wet exhaust, worked-out drying agent. Among other principal disadvantages common to all dryers of this type, the following have to be mentioned: spatial inhomogeneity of heating a product under processing and that of drying agent distribution due to its temperature reduction and relative humidity growth as it moves upwards. A block diagram and a breadboard model of a convective-type thermoelectric dryer employing a thermoelectric heat pump have been designed. In our approach, a product is treated with the help of a drying agent (normally, heated air) with partial exhaust-air recirculation and heat recovery. Laboratory studies of the drying process have been carried out using apple fruits as a test material in order to evaluate the power consumed for evaporation of 1 kg of water in the newly developed convective-type thermoelectric drying unit. Physical parameters of apple fruits before and after drying both in the thermoelectric drying unit and in a conventional series-produced convective-type domestic dryer have been reported. The energy efficiency of the newly designed drying unit has been compared with that of some series-produced samples. It has been found out that, unlike conventional convective-type dryers, the breadboard model of the developed thermoelectric drying unit features a smoother product drying process owing to the presence of side air channels and more effective drying agent path organization in the processing chamber. This conclusion was supported by the results of the carried out tests. Application of thermoelectric heat pumps with the function of the exhaust drying agent heat recovery will make it possible to reduce the drying agent heater installed capacity and the power consumed by the newly designed convective-type thermoelectric drying unit by up to 20% in the course of the drying process, compared to series-produced household convective-type dryers.

1. Introduction

Thermal drying of products and materials is an integral stage of many agricultural production technologies and belongs to the most energy-demanding processes [1]. Dried vegetables, fruits, and berries can be stored in rather good condition and easily transported. Their storage does not require large area sizes, and they are widely used in the food industry as feed stocks for manufacturing various products [2]. Theoretical studies have been made to define the time and heating rate for cut-up apples in the radiant-heat drying method. Experimental studies of the drying process in a radiant-heat dryer for wild fruits and vegetables have been carried out as well [3,4].
In paper [5], an algorithm of energy-saving optimization for grain-cleaning-drying technological complex was described, making it possible to reduce both the direct energy intensity and power consumption of flow processing lines, and a method was proposed for calculating the potential of direct energy savings in the frames of existing technical-technological limits and financial stringencies. An energy-saving operation mode of a conductive-convective mini-grain dryer was suggested that partially uses the heat of solar radiation captured with the help of a solar collector, as well as that stored in a heat accumulator, with the addition of thermal energy received by recirculation of the exhaust drying agent [6]. An automated agricultural feedstock drying system was designed to ensure biotechnological heating conditions for particular product types, making it possible to retain the properties of its essential biological components [7]. Theoretical and experimental studies were performed in order to evaluate the effectiveness of thermoelectric cooler use for collecting water in the process of outdoor air dehumidification, including the case when they are applied in combination with solar photoelectric panels [8,9]. Jaber et al. [10] carried out theoretical studies of a thermoelectric cogeneration drying unit for heating air and water and electric energy production equipped with a multistep flue gas heat utilization system. Thermoelectric units for air cooling and heating were proposed to be integrated in the air duct system on premises, and the corresponding theoretical and experimental studies were made [11,12]. Design options of air dehumidification thermoelectric units were proposed and studied [13,14,15]. Malik et al. [16] carried out theoretical studies of the efficiency of solar photoelectric panels for the case of their application in combination with thermoelectric units in order to reduce the temperature of the solar cells, thus reducing the power loss of the entire photoelectric system. The results of studies on raising the efficiency of heat utilization by thermoelectric converters aimed at electric power production growth were reported [17,18,19].
The possibility of heat pumps being used in the drying process was considered in papers [20,21]. Junior et al. [22] proposed a design of a convective-type dryer with a thermoelectric heat pump equipped with a recuperative heat exchanger. A mathematical model describing the designed dryer operation was proposed in order to evaluate its productivity. A design for the vacuum freeze dryer was developed by employing thermoelectric units whose parameters and operation modes were substantiated [23].
Theoretical and experimental studies were performed in order to evaluate the operation efficiency of the designed thermoelectric dryer for clothes [24,25]. The experimental study results for thermoelectric heat pumps designed for drying green crops [26] and for a solar thermoelectric generator for drying grapes [27] were reported.
In household dryers, as well as in industrial dryer units of small productivity, the convective method for heating a product under processing is normally applied. In the majority of series-produced convective-type household electric units designed for drying vegetables and fruits, in the process of drying food stuffs, thermal energy generated by an electric heater, in the course of heating the air, is released into the environment along with the wet air. On the other hand, even partial wet air recirculation around a closed path without dehumidification will make the drying process go on for a long time, thus degrading the quality of a product under processing and not bringing a significant energy-saving effect [28].
Therefore, the major disadvantage of convective-type electric dryers is thermal energy loss with moisture-laden air released into the environment. One more drawback of dryers having similar designs is the nonuniformity of the heating product under processing and the decrease in the temperature of the drying agent as it moves up through the pallets in the dryer housing. As a result, products placed on the bottom pallets dried faster compared to those placed on the upper ones. As a result, to ensure uniform drying of food products, it is necessary to periodically swap the bottom and lower pallets of the dryer. From the literature review, it can be concluded that the main areas of thermoelectric heat pump and Peltier elements application are ventilation systems for buildings where supply air is processed (dehumidification, heating, and cooling), as well as units using renewable energy sources. At the same time, very few works are devoted to applied research on increasing the drying process efficiency by improving the design of convection household dryers and assessing the energy-saving potential when drying food products using a thermoelectric heat pump.
The aim of our research is to carry out experimental studies of the apple fruit drying process for evaluating the specific amount of power consumed in the course of evaporation of 1 kg of water in the newly designed convective-type thermoelectric drying unit in order to compare its energy efficiency with that of the series-produced samples.

2. Materials and Methods

One of the effective methods to improve the energy efficiency of technological processes in agro-industrial complexes is the application of thermoelectric units and assemblies based on Peltier elements in various technological cycles, such as air dehumidification and heating [29,30], pasteurization and cooling milk [31], and young animals local heating [32]. In paper [33], the application of a thermoelectric heat pump designed to heat a drying agent in drying units was substantiated, providing a considerable reduction of power consumption and maintaining high quality indicators of a final product in drying processes compared to conventional convective-type household dryers mainly employing a tubular electric heater as a drying agent heating device.
The operating principle of a thermoelectric heat pump is as follows: the cold circuit of the thermoelectric assembly absorbs some part of thermal energy from the exhaust air in the drying unit and transfers it to the hot circuit, thus increasing thermal energy production on the hot side of the thermoelectric unit. This thermal energy is used for heating air to reduce the power consumed from the electric grid.
The newly designed thermoelectric assembly represents a thermoelectric heat pump on the basis of Peltier elements TEC1-22818 performing the drying agent heating function (see Figure 1). Specifications of Peltier elements are presented in Table 1.
Based on the carried out theoretical and experimental studies, the block diagram and a laboratory sample of the convective-type thermoelectric dryer comprising a thermoelectric assembly have been designed.
The function principle of the newly designed thermoelectric drying unit operating in the heat pump mode is shown in Figure 2 [34].
A product under processing is heated by the hot air with partial recirculation and exhaust-air heat recovery. The drying agent is additionally heated as it passes through thermoelectric assembly 5, and then it is transported into drying chamber 11 via air supply duct 10. Then, the drying agent flow coming from air exhaust chamber 12 gets divided. One of its parts is transported into air exhaust channel 14, while the other is directed into circulation air duct 13. Outdoor air enters mixing chamber 9 through air intake damper 8 and air supply channel 7, wherefrom it is directed to hot-junction radiator 5 of the thermoelectric heat pump with the use of circulation fan 6. From exhaust-air channel 14, the drying agent is transported onto cold-junction radiator 3 of the thermoelectric heat pump, where exhaust agent heat recovery takes place. Then, the air is put out into the environment with the help of exhaust-air fan 2 via exhaust-air channel 1. Outdoor air is captured via intake damper 8. Outdoor air passes the casing of the main power supply unit (220VAC/24VDC), where it is previously heated by cooling internal electric circuit components.

3. Results and Discussion

Based on the newly designed block diagram, a physical model of the thermoelectric drying unit was manufactured for studying the drying process parameters.
Figure 3 shows the block diagram of the thermoelectric drying unit with air temperature and humidity sensors positions along with the laboratory sample layout.

3.1. Laboratory Tests of the Newly Designed Thermoelectric Drying Unit

Laboratory tests of the drying process with apple fruits grade “Gala” subject to processing were performed on five pallets in both the thermoelectric drying unit and household convective-type dryer ROTOR SH-002 with the following parameters: initial values of moisture content were 80%, ambient air temperature was 20 ± 1 °C, and relative humidity was 45 ± 2%. Temperature and humidity values met the requirements of [35]. Temperature measurements were carried out with Chromel–Kopel thermocouples connected to temperature metering and control unit TRM138 at several control points inside the body of the dryers under study. Relative air humidity was recorded by sensors at the supply opening for the intake of outside air and at the outlet for exhaust spent drying agent. The total energy consumption during the drying process was recorded using a single-phase electric energy meter with accuracy class 1.
The residual moisture content determination in the dried product (using the example of apples) was carried out by an indirect method, according to the recommendations given in [36].
Averaged parameters of apples before and after drying in the thermoelectric drying unit obtained in the course of laboratory tests are presented in Table 2.
Averaged parameters of the apple fruit drying process in convective-type dryer ROTOR SH-002 obtained in the course of laboratory tests are presented in Table 3.
Figure 4 shows the layout of convective-type dryer ROTOR SH-002 with the air temperature and humidity sensors in the course of laboratory tests.
Table 4 presents the estimation results of power consumption for 1 kg of evaporated water in a newly designed thermoelectric dryer in comparison with some of its series-produced analogues.
The specific energy consumption calculation for evaporation of 1 kg from the dried product is carried out according to the following formula Wi:
W i = W agg ( m 1 m 2 ) ,
where Wagg is the aggregate electricity consumption for the entire drying period, kW·h/kg; m1 is the initial mass of the wet product, kg; and m2 is the final mass of the dried product, kg.
Calculated data were reported for series-produced samples No. 2–6 (see Table 4), while for samples No. 1 and No. 7, experimental data obtained in conditions identical to those of laboratory sample No. 8 are presented.
The readings of the studied values were taken at least five times. A sample of experimental data was used as the resulting values for further statistical processing, and their arithmetic averages were taken. Also, as a result of statistical processing, random variables, lower and upper confidence limits were found, forming a confidence interval.
In the final drying mode, after 5 h of basic drying (see Figure 5), pallets with apples were weighed every 20–30 min on laboratory analytical balances. When the moisture content normative in apples was reached (20–22%) the drying process was completed [35].
Figure 5 shows drying process temperature diagrams for measuring points of the newly designed laboratory sample of the thermoelectric drying unit.
Figure 6 shows the change in drying agent relative humidity depending on time, in the intake and in the output of the drying unit. Sharp growth of the air relative humidity in the output from the drying unit (φa2) in the initial drying process period can be attributed to intensive water evaporation from the surface of the product under processing.
In Figure 5, cyclic change in the air temperature (checkpoints T1–T6) and that in the air relative humidity (φa2), in the output from the drying unit, has to be associated with the operation of the air temperature and relative humidity metering and control module integrated into the drying unit (see Figure 3b).

3.2. Calculating the Thermal Flow Qc Supplied to the Cold-Junction Radiator of the Thermoelectric Heat Pump

In order to calculate the energy efficiency of the thermoelectric heat pump application, let us define the amount of heat Qc absorbed by the cold-junction radiator of the thermoelectric heat pump. This heat is extracted from the exhaust drying agent in the drying unit. The amount of heat was estimated by both theoretical calculations and in experiments with the application of statistical repeating procedures and data reduction processes.
Theoretical calculations were based on determining the thermal EMF of the thermoelectric module cold circuit.
The thermal EMF value ( ε T , c ) for the thermoelectric module cold junctions can be calculated from the following equation [37]:
ε T , c = E t c N j ,
where ε T , c is the thermal EMF of the module cold side (V); E is the thermal EMF coefficient (Seebeck coefficient), for the thermoelectric junction, equal to 96 (µV·K–1); Nj is the number of junctions in a module (one 50 × 50 mm Peltier module comprises 228 junctions); and tc is the average temperature value of the cold-junction radiator of the thermoelectric heat pump, equal to 38 °C (this value was determined experimentally on the drying unit laboratory sample).
By substituting numerical values, we obtain ε T , c = 6.8 V. Based on the results of the performed experiments on the product subject to drying, it was found out that the average current value of the thermoelectric module was 8.2 ± 0.4 A. Wherefrom the theoretical thermal energy flow Qc absorbed by the cold circuit of the thermoelectric pump from the exhaust drying agent is 55.8 W.
The following equation was applied to determine the experimental value of the heat flow rate Qc supplied to the cold-junction radiator of the thermoelectric heat pump with the account of the above-mentioned parameter values:
Q c = c a L a Δ t ,
where ca is air specific heat capacity (assumed to be equal to 1.3 kJ·m–3·°C–1); La is air flow rate (m3/s); and ∆t is drying agent (air) temperature difference in the input and in the output of the cold-circuit radiator of the thermoelectric assembly (°C).
The airflow rate of the exhaust drying agent in the outlet duct (Foc = 0.00232 m2) was measured in the course of the drying process with the use of the thermal anemometer TKA-RKM60 equipped with an external probe (wa,oc = 2.2–2.5 m/s).
For wet air specific heat capacity value 1.3 kJ·m–3·°C–1, average heat flow rate Qc absorbed from the exhaust drying agent and supplied to the cold-junction radiator of the thermoelectric heat pump is 52.8 W, for the average value of temperature drop between points T4 and T5 equal to 7.3 °C in the drying process (see Figure 5), which corresponds to ~20% of the aggregate power (~240 W) consumed by the thermoelectric drying unit from the electric grid (see Table 5).
The technical parameters of the thermoelectric drying unit laboratory sample are presented in Table 5.
Values of heat absorbed by the cold junction of the thermoelectric heat pump obtained by calculations are in rather good correlation with those measured in experiments, which can be considered a proof of the heat pump operating mode of the thermoelectric assembly. A laboratory sample of the newly designed thermoelectric drying unit features a smoother product drying process owing to the presence of side air channels and effective drying agent path organization in the process chamber (see Figure 2). This conclusion is supported by the results of the carried out tests (see Table 3). In the case of drying various products in conventional series-produced household convective-type dryers (see Table 5), one has to swap periodically locations of pallets in the upper and lower parts of the unit in order to maintain a more homogeneous product drying process. Thermoelectric dryers for vegetables and fruits have to comply with the requirements of particular drying process technology, making it possible to set drying agent temperature modes within its optimal range.

3.3. Calculating the Heat Balance of the Thermoelectric Drying Unit

The equation for the internal heat balance of the drying unit under study has the following form:
q c + q e = q m + q h + k q a c liq θ 1 ,
where qc is the specific amount of heat absorbed from the exhausted drying agent that is further supplied to the cold-junction radiator of the thermoelectric module (kJ per 1 kg water); qe is the specific amount of heat produced by electric current in the thermoelectric module (kJ per 1 kg water); cliq is the specific heat capacity of the fluid component within a wet product under processing for initial product temperature (supposed to be equal to that of environment) θ1 (kJ·kg–1·°C–1) in the dryer input; qm is the specific heat consumption in the dryer, used for heating a product under processing (kJ per 1 kg water); qh is the specific heat emission from the drying unit casing surface into the environment (kJ per 1 kg water); qa is the specific heat loss with the exhaust drying agent (air) (kJ per 1 kg water); and k is the coefficient taking account of the share of heat absorbed by the cold-junction radiator of the thermoelectric module from the exhaust drying agent (equals to 0.80–0.88).
The aggregate value of the specific heat qc absorbed from the exhaust drying agent and supplied to the cold-junction radiator of the thermoelectric module, along with the specific amount of heat qe produced by electric current in the thermoelectric module, gives the total value qhot of specific heat absorbed by a drying agent from the hot-junction radiator of the thermoelectric heat pump.
Specific heat flow into the drying unit consumed for heating a product under processing can be defined from the following expression:
q m = G 2 c m ( θ 2 θ 1 ) W + c liq ( θ 2 θ 1 ) ,
where G2 is drying unit productivity expressed in final (dried) product weight (kg/s); cm is specific heat capacity of dried product (kJ·kg–1·°C–1), we assume that the average value cm = 3.88 kJ·kg–1·°C–1, for apple fruits; W is amount of water extracted from a product under processing (kg/s); and θ2 is product temperature in the output from the dryer (°C).
Therefore, the drying unit performance in terms of dried product outcome equals to the following:
G 2 = G 1 W = G 1 φ 1 φ 2 1 φ 2 = G 1 1 φ 1 1 φ 2 ,
where G1 is drying unit performance measured in initial (wet) product weight (kg/s), and φ1 and φ2 are values of moisture content (%) in the initial product and in that that has passed the dying procedure, respectively.
The amount of water W extracted from the material under processing can be defined from the following expression:
W = G 1 φ 1 φ 2 1 φ 2 = G 2 φ 1 φ 2 1 φ 1 .
We assume the product temperature in the output from the dryer θ2 to be equal to that of the wet-bulb thermometer t2w. In a theoretical approach, the drying process is assumed to comply with the adiabatic relationship, in which case t2w can be determined from the i-d diagram for wet air conditions and for specified initial drying agent parameters (temperature t1 and moisture content d1).
Dried product-specific heat capacity can be calculated using the following formula:
c m = c d 100 + c liq φ 2 100 + φ 2 ,
where cd is specific heat capacity of moisture-free material (KJ·kg–1·°C–1), and φ2 is final moisture content in product after the drying process completion (%).
Specific heat loss qh from the dryer casing surface into the environment is assumed to be in the range from 125 kJ to 420 kJ per 1 kg of evaporated water, depending on the moisture content of the particular material (for apple fruits, the lower value has to be selected). Alternatively, the value of this parameter can be selected in the range from 10% to 12% of specific heat qm absorbed in the drying unit for heating a product under processing [38]. Specific heat emission from the dryer casing surface into the environment can also be determined with the help of expression, provided that the value of coefficient Kh for heat transfer through the casing walls has been defined [28].
Specific heat loss with the exhaust drying agent (air) qB is determined from the following formula:
q a = G a c a ( t 2 t 0 ) W ,
where Ga is the drying agent flow rate during the drying process (kg/s); ca is the drying agent’s (air) specific heat capacity (kJ·kg–1·°C–1); t2 is the exhaust drying agent temperature (°C); and t0 is the ambient air temperature (°C).
The drying agent’s flow rate in the process of drying equals to the following:
  G a = W d 2 d 1 ,
where d1 = d0 is air moisture content (kg/kg) in the dryer input (air is heated in the dryer as it passes through the hot-junction radiator of the thermoelectric assembly in conditions of constant moisture content d = const), and d2 is moisture content of air in the dryer output (kg/kg).

3.4. Calculating the Hot-Junction Radiator Design Parameters of the Thermoelectric Drying Unit Heat Pump

Calculations were carried out with the purpose of defining the design parameters of an air radiator (see Figure 7), making it possible to transfer heat from the hot side of the thermoelectric module to the drying agent (air) with minimal loss.
The following initial design parameters were defined while calculating air radiator (see Figure 7) design parameters: ΣQ is the thermal performance of the thermoelectric assembly (W); λr is the radiator material thermal conductivity coefficient (W·m–1·°C–1); λa is the air thermal conductivity coefficient (W·m–1·°C–1) for specified temperature values.
We considered an option with forced radiator air cooling. The value of drying agent (air) velocity wa in the space between the air radiator fins was assumed to be from 2 m/s to 4 m/s, based on the typical parameters of similar unit design options [39].
In order to define heat transfer coefficient αr, one has to select appropriate values of air velocity wa and of kinematic viscosity νa depending on the temperature of air flowing about the radiator fins. Reynolds number Re has to be determined as well. Depending on the Reynolds number calculated value Re (whether laminar or turbulent air flow mode takes place), Nusselt number Nu is calculated with the use of a formula (either 11 or 12) [40].
For a laminar (air) flow mode, we have the following:
Nu L = 0.57 Re L 0.5 .
For a turbulent (air) flow mode, the following expression is valid:
Nu L = 0.032 Re L 0.8 .
For a given velocity of air flowing about the radiator fins, the convective heat transfer exchange coefficient αr can be calculated with the use of Reynolds (Re) and Nusselt (Nu) numbers as follows:
α r = Nu λ a L .
The air radiator overall dimensions can be defined from the following expression, insuring the most reasonable relationship between fin thickness b and its height H when the maximum heat exchange is achieved for an acceptable specific quantity of metal required for radiator fin fabrication [39]:
H = 1.419 b 2 2 λ r α r b .
The area of a single radiator fin Fr′ supplying thermal energy to a drying agent is as follows:
F r = 2 H L .
Drying agent contacts with the radiator, whose total heat exchange surface area Fr can be deduced from the following heat flow rate equation:
Q = K t F r Δ t a ,
where ΣQ is heat flow rate of the thermoelectric assembly (heat pump) hot circuit (W) (normally defined based on particular type of thermoelectric module specifications); Fr is the surface area of all radiator fins (m2); Δta = ta1ta2 is the specified temperature difference for air in radiator input and output (°C); and K t = 1 1 / α r + A / λ r is heat exchange rate for heat transfer from the thermoelectric module surface to a drying agent (W·m–2·°C–1).
The number of radiator fins N is calculated as follows:
N = F r F r .
With the account of the selected value of drying agent velocity wa, the cross-section fc of the air channel in which the thermoelectric module air radiator has to be installed can be defined as follows:
f c = G a w a

4. Conclusions

In accordance with the newly designed block diagram, a laboratory sample of a thermoelectric drying unit has been manufactured for studying the drying process parameters. Laboratory studies of the apple fruit drying process have been carried out in order to evaluate specific power consumption for evaporating 1 kg of water in the newly designed convective-type thermoelectric drying unit. The values of this indicator were compared with those of some series-produced household dryers.
The drying process was performed with partial recirculation and heat recovery of the exhaust drying agent heat. The diagrams for temperature change in the reference points and for the drying agent relative humidity in both the input and the output of the thermoelectric drying unit have been presented, making it possible to characterize the drying process in its dynamic development. The properties of apple fruits before and after processing in the thermoelectric drying unit have been reported along with those of ones dried with the use of conventional series-produced convective-type dryers.
It has been found out that application of a thermoelectric heat pump ensuring exhaust agent heat recovery makes it possible to reduce both the capacity of the drying agent heater and the electric power consumption in the course of drying in the newly designed convective-type thermoelectric drying unit by 20% compared to conventional series-produced household dryers.
A laboratory sample of the thermoelectric drying unit ensures more homogeneous drying product process conditions owing to the presence of side air channels and a more effective drying agent path structure in the processing chamber compared to conventional convective-type dryers. This conclusion was confirmed by the results of the carried out studies.
In the newly designed thermoelectric unit, the difference in the amount of evaporated water in different pallets did not exceed 2.5% by the end of the apple fruit drying process. For conventional convective-type dryers, the value of this parameter is more than 12.5%.
Mathematical expressions for calculating the dimensions of the hot-junction radiator of the thermoelectric heat pump (type “air-to-air”) have been presented that form the core of substantiating basic parameters of the thermoelectric assemblies of various performance for drying units of the proposed design.
Further research will be focused on optimizing the operating modes of convective-type thermoelectric drying units with the account of current values of moisture content in a product under processing, amount of recirculation air, and amount of exhaust air from the drying unit and sent for recovery to a thermoelectric heat pump, as well as the amount of mixed-in outdoor air in during the drying process to automatically regulate the supply air intake damper position.

Author Contributions

Conceptualization, D.T. and A.K. (Aleksei Khimenko); methodology, A.K. (Aleksei Kuzmichev), D.T. and A.K. (Aleksey Khimenko); validation, D.T. and A.K. (Aleksei Khimenko); formal analysis, A.K. (Aleksei Khimenko) and D.B.; investigation, D.T., A.K. (Aleksei Khimenko) and A.K. (Aleksey Kuzmichev); resources, A.K. (Aleksei Khimenko); data curation, D.T., A.K. (Aleksei Khimenko) and V.B.; writing—original draft preparation, D.T. and A.K. (Aleksei Khimenko); writing—review and editing, A.K. (Aleksei Khimenko), D.T. and D.B.; visualization, A.K. (Aleksei Khimenko) and D.T.; supervision, D.B. and V.B. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data are contained within the article.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Kudryashev, G.S.; Tretyakov, A.N.; Batishchev, S.V.; Bochkarev, V.A.; Ochirov, V.D. Characteristics of the Cost of Electricity Consumption in Agricultural Production. IOP Conf. Ser. Earth Environ. Sci. 2021, 677, 032087. [Google Scholar] [CrossRef]
  2. Neverov, E.N.; Korotkiy, I.A.; Gorelkina, A.K.; Zadesenets, A.E. Investigation of the Parameters of the Dehydrator for the Implementation of Convective Drying of Moisture-Containing Foods. Izv. Low. Volga Agro-Univ. Complex 2023, 2, 466–479. (In Russian) [Google Scholar] [CrossRef]
  3. Ochirov, V.D.; Fedotov, V.A. The Determination of Time and Speed of Chopped Apples Heating during Thermal and Radiation Drying Process. Bull. KrasGAU 2018, 1, 89–95. (In Russian) [Google Scholar]
  4. Altukhov, I.V.; Ochirov, V.D.; Fedotov, V.A. Experimental IR Installation for Drying Fruits and Vegetables. VestnikIrGSHA 2017, 81–82, 90–96. (In Russian) [Google Scholar]
  5. Sap’yan, Y.N.; Kolos, V.A.; Suleymanov, M.I.; Kabakova, E.N. Assessing and Reducing Energy Consumption of Grain Cleaning and Drying Equipment. Agric. Mach. Technol. 2019, 13, 51–55. (In Russian) [Google Scholar] [CrossRef]
  6. Gasanov, U.R.; Magerramova, S.A. Performance Efficiency of an Energy-Saving Mini Dryer with a Combined Heat Supply System. Agric. Mach. Technol. 2018, 12, 9–14. (In Russian) [Google Scholar] [CrossRef]
  7. Altukhov, I.V.; Bykova, S.M.; Lukina, G.V.; Ochirov, V.D. Automation of the Drying Process of Agricultural Raw Materials to Obtain Products of High Nutritional Value. IOP Conf. Ser. Earth Environ. Sci. 2020, 421, 032019. [Google Scholar] [CrossRef]
  8. Milani, D.; Abbas, A.; Vassallo, A.; Chiesa, M.; Bakri, D. Evaluation of Using Thermoelectric Coolers in a Dehumidification System to Generate Freshwater from Ambient Air. Chem. Eng. Sci. 2011, 66, 2491–2501. [Google Scholar] [CrossRef]
  9. Jradi, M.; Ghaddar, N.; Ghali, K. Experimental and Theoretical Study of an Integrated Thermoelectric–Photovoltaic System for Air Dehumidification and Fresh Water Production. Int. J. Energy Res. 2012, 36, 963–974. [Google Scholar] [CrossRef]
  10. Jaber, H.; Khaled, M.; Lemenand, T.; Murr, R.; Faraj, J.; Ramadan, M. Domestic Thermoelectric Cogeneration Drying System: Thermal Modeling and Case Study. Energy 2019, 170, 1036–1050. [Google Scholar] [CrossRef]
  11. Yilmazoglu, M.Z. Experimental and Numerical Investigation of a Prototype Thermoelectric Heating and Cooling Unit. Energy Build. 2016, 113, 51–60. [Google Scholar] [CrossRef]
  12. Irshad, K.; Habib, K.; Thirumalaiswamy, N.; Saha, B.B. Performance Analysis of a Thermoelectric Air Duct System for Energy-Efficient Buildings. Energy 2015, 91, 1009–1017. [Google Scholar] [CrossRef]
  13. Irshad, K.; Almalawi, A.; Habib, K.; Zahir, M.H.; Ali, A.; Islam, S.; Saha, B.B. Experimental Study of a Thermoelectric Air Duct Dehumidification System for Tropical Climate. Heat Transf. Eng. 2021, 42, 1159–1171. [Google Scholar] [CrossRef]
  14. Yao, Y.; Sun, Y.; Sun, D.; Sang, C.; Sun, M.; Shen, L.; Chen, H. Optimization Design and Experimental Study of Thermoelectric Dehumidifier. Appl. Therm. Eng. 2017, 123, 820–829. [Google Scholar] [CrossRef]
  15. Vián, J.G.; Astrain, D.; Domínguez, M. Numerical Modelling and a Design of a Thermoelectric Dehumidifier. Appl. Therm. Eng. 2002, 22, 407–422. [Google Scholar] [CrossRef]
  16. Malik, M.S.; Arbab, M.N.; Khan, M.O.; Malik, M.A.; Asghar, M.U. Simulation Study to Evaluate the Hybrid Photovoltaic—Thermoelectric Energy Generation System with Heat Recovery Mechanism. Energy Sources Part A Recover. Util. Environ. Eff. 2021, 11, 6. [Google Scholar] [CrossRef]
  17. Jaber Abdulhamed, A.; Al-Akam, A.; Abduljabbar, A.A.; Alkhafaji, M.H. Waste Heat Recovery from a Drier Receiver of an A/C Unit Using Thermoelectric Generators. Energy Eng. 2023, 120, 1729–1746. [Google Scholar] [CrossRef]
  18. Lu, X.; Yu, X.; Qu, Z.; Wang, Q.; Ma, T. Experimental Investigation on Thermoelectric Generator with Non-Uniform Hot-Side Heat Exchanger for Waste Heat Recovery. Energy Convers. Manag. 2017, 150, 403–414. [Google Scholar] [CrossRef]
  19. Rabari, R.; Mahmud, S.; Dutta, A.; Biglarbegian, M. Effect of Convection Heat Transfer on Performance of Waste Heat Thermoelectric Generator. Heat Transf. Eng. 2015, 36, 1458–1471. [Google Scholar] [CrossRef]
  20. Romanova, E.V.; Orlov, A.Y. Possibilities of Using Heat Pumps in Drying Process. Trans. TSTU 2008, 14, 591–596. (In Russian) [Google Scholar]
  21. Konovalov, V.I.; Romanova, E.V.; Gatapova, N.C. Drying with Heat Pumps in Chemical Industry: Opportunities and Experimental Techniques. Trans. TSTU 2011, 17, 153–178. (In Russian) [Google Scholar]
  22. Junior, C.; Chen, G.; Koehler, J. Modeling of a New Recuperative Thermoelectric Cycle for a Tumble Dryer. Int. J. Heat Mass Transf. 2012, 55, 1536–1543. [Google Scholar] [CrossRef]
  23. Barykin, R.A.; Poymanov, V.V.; Shakhov, S.V. Development of Vacuumsublimation Dryers Using Thermoelectric Modules. Proc. Vor. State Univ. Eng. Technol. 2014, 1, 47–50. (In Russian) [Google Scholar]
  24. Patel, V.K.; Gluesenkamp, K.R.; Goodman, D.; Gehl, A. Experimental Evaluation and Thermodynamic System Modeling of Thermoelectric Heat Pump Clothes Dryer. Appl. Energy 2018, 217, 221–232. [Google Scholar] [CrossRef]
  25. Liu, D.; Zhao, F.Y.; Tang, G.F. Modeling and Performance Investigation of a Closed-Type Thermoelectric Clothes Dryer. Dry. Technol. 2008, 26, 1208–1216. [Google Scholar] [CrossRef]
  26. Wongsim, K.; Jamradloedluk, J.; Lertsatitthanakorn, C.; Siriamornpun, S.; Rungsiyopas, M.; Soponronnarit, S. Experimental Performance of a Thermoelectric Heat-Pump Drying System for Drying Herbs. J. Electron. Mater. 2015, 44, 2142–2145. [Google Scholar] [CrossRef]
  27. Singh, A.P.; Gupta, A.; Biswas, A.; Das, B. Experimental Study of a Novel Photovoltaic-Thermal-Thermoelectric Generator-Based Solar Dryer for Grapes Drying. Int. J. Green Energy 2023, 21, 1161–1173. [Google Scholar] [CrossRef]
  28. Tikhomirov, D.; Trunov, S.; Kuzmichev, A.; Lamonov, N. The Principle of Building an Energy-Saving Drying Plant Using Thermoelectricity. Elektrotekhnologii I Elektrooborud. V APK 2021, 68, 16–22. (In Russian) [Google Scholar] [CrossRef]
  29. Tikhomirov, D.A.; Trunov, S.S.; Kuzmichev, A.V.; Rastimeshin, S.A.; Shepovalova, O.V. Energy-Efficient Thermoelectric Unit for Microclimate Control on Cattlebreeding Premises. Energy Rep. 2020, 6, 293–305. [Google Scholar] [CrossRef]
  30. Venkatesan, K.; Venkataramanan, M. Experimental and Simulation Studies on Thermoelectric Cooler: A Performance Study Approach. Int. J. Thermophys. 2020, 41, 38. [Google Scholar] [CrossRef]
  31. Kirsanov, V.V.; Kravchenko, V.N.; Filonov, R.F. Use of Thermoelectric Modules in Pasteurization and Cooling Plants for the Processing of Liquid Products; FGBOU VPO MGAU Publishing: Moscow, Russia, 2011. (In Russian) [Google Scholar]
  32. Tikhomirov, D.; Khimenko, A.; Kuzmichev, A.; Bolshev, V.; Samarin, G.; Ignatkin, I. Local Heating through the Application of a Thermoelectric Heat Pump for Prenursery Pigs. Agriculture 2023, 13, 948. [Google Scholar] [CrossRef]
  33. Tikhomirov, D.A.; Yashin, I.S.; Khimenko, A.V.; Kuzmichev, A.V. Physical Modeling of the Drying Process Using Thermoelectric Heat Pump. Mach. Equip. Rural Area 2023, 1, 40–45. (In Russian) [Google Scholar] [CrossRef]
  34. Trunov, S.S.; Tikhomirov, D.A.; Kuzmichev, A.V.; Lamonov, N.G. Thermoelectric Dryer. Application. No. 2019125012, 21 December 2020. RU Patent 2749682 C1, 16 June 2021. (In Russian). [Google Scholar]
  35. GOST 32896-2014; Dried Fruits. General Specifications. Standardinform: Moscow, Russia, 2015. (In Russian)
  36. GOST R 54607.4-2015; Methods for Laboratory Control of Public Food Products. Part 4. Methods for Determining Moisture and Dry Substances. Standardinform: Moscow, Russia, 2016. (In Russian)
  37. Pokorny, E.G.; Shcherbina, A.G. Calculation of Semiconductor Cooling Devices; Nauka: Leningrad, Russia, 1969. (In Russian) [Google Scholar]
  38. Dytnersky, Y.I. Processes and Apparatus of Chemical Technology. Part 2. Mass Transfer Processes and Apparatus; Ximiya: Moscow, Russia, 1995. (In Russian) [Google Scholar]
  39. Kaplya, V.I.; Burtsev, A.G.; Soboleva, E.K.; Andriyanov, S.A. The Calculation of Peltier Working Mode Using as a Cooler in Air Drying Module. Eng. J. Don 2017, 2, 70. (In Russian) [Google Scholar]
  40. Mikheev, M.A.; Mikheeva, I.M. Fundamentals of Heat Transfer; Energia: Moscow, Russia, 1977. (In Russian) [Google Scholar]
Figure 1. Overall view of the thermoelectric assembly based on Peltier elements: 1—cold-circuit fan; 2, 6—heat-insulating liner; 3—cold-circuit air radiator; 4—Peltier element; 5—hot-circuit air radiator; 7—hot-circuit fan; and 8—Peltier element power terminal block.
Figure 1. Overall view of the thermoelectric assembly based on Peltier elements: 1—cold-circuit fan; 2, 6—heat-insulating liner; 3—cold-circuit air radiator; 4—Peltier element; 5—hot-circuit air radiator; 7—hot-circuit fan; and 8—Peltier element power terminal block.
Agriculture 14 00922 g001
Figure 2. Block diagram of the drying unit using a thermoelectric assembly operating in the heat pump mode: 1—outlet duct; 2—exhaust-air fan; 3—cold-junction radiator; 4—Peltier elements; 5—hot-junction radiator; 6—circulation fan; 7—air supply channel; 8—air intake damper; 9—mixing chamber; 10—air supply duct; 11—drying chamber; 12—exhaust-air chamber; 13—circulation air duct; and 14—exhaust-air channel.
Figure 2. Block diagram of the drying unit using a thermoelectric assembly operating in the heat pump mode: 1—outlet duct; 2—exhaust-air fan; 3—cold-junction radiator; 4—Peltier elements; 5—hot-junction radiator; 6—circulation fan; 7—air supply channel; 8—air intake damper; 9—mixing chamber; 10—air supply duct; 11—drying chamber; 12—exhaust-air chamber; 13—circulation air duct; and 14—exhaust-air channel.
Agriculture 14 00922 g002
Figure 3. Air temperature T1–T6 and humidity sensor (φa1 and φa2) positions in the drying chamber (a): T1—hot radiator surface; T2—air supplied into the drying chamber after heating; T3—air in the drying chamber; T4—air leaving the drying chamber; T5—exhaust air removed from the drying unit; T6—ambient air; φa1 is air relative humidity in the intake of drying unit; and φa2 is air relative humidity in the output from the drying unit; layout of the thermoelectric drying unit with the air temperature and humidity sensors (b): 1—temperature and humidity control meter; 2—outlet for exhaust drying agent; and 3—air intake damper control.
Figure 3. Air temperature T1–T6 and humidity sensor (φa1 and φa2) positions in the drying chamber (a): T1—hot radiator surface; T2—air supplied into the drying chamber after heating; T3—air in the drying chamber; T4—air leaving the drying chamber; T5—exhaust air removed from the drying unit; T6—ambient air; φa1 is air relative humidity in the intake of drying unit; and φa2 is air relative humidity in the output from the drying unit; layout of the thermoelectric drying unit with the air temperature and humidity sensors (b): 1—temperature and humidity control meter; 2—outlet for exhaust drying agent; and 3—air intake damper control.
Agriculture 14 00922 g003
Figure 4. Overall view of the convective-type dryer ROTOR SH-002 with temperature and humidity sensors.
Figure 4. Overall view of the convective-type dryer ROTOR SH-002 with temperature and humidity sensors.
Agriculture 14 00922 g004
Figure 5. Drying process temperature diagram for characteristic points of the thermoelectric drying unit: T1—hot radiator surface; T2—air supplied into the drying chamber after heating; T3—air in the drying chamber; T4—air leaving the drying chamber; T5—exhaust air removed from the drying unit; and T6—ambient air.
Figure 5. Drying process temperature diagram for characteristic points of the thermoelectric drying unit: T1—hot radiator surface; T2—air supplied into the drying chamber after heating; T3—air in the drying chamber; T4—air leaving the drying chamber; T5—exhaust air removed from the drying unit; and T6—ambient air.
Agriculture 14 00922 g005
Figure 6. Change in the drying agent’s (air) relative humidity during the product drying process, in the intake (φa1) and in the output (φa2) of the drying unit.
Figure 6. Change in the drying agent’s (air) relative humidity during the product drying process, in the intake (φa1) and in the output (φa2) of the drying unit.
Agriculture 14 00922 g006
Figure 7. Diagram of an air-to-air thermoelectric heat pump: 1—Peltier thermoelectric element; 2—hot-circuit air radiator fins; and 3—cold-circuit air radiator fins; A is radiator base thickness; B is air radiator size in the direction perpendicular to the fin plane; b is the fin thickness; H is the fin height; h is the distance between the adjacent fins; L is air radiator size in the line of the fin plane.
Figure 7. Diagram of an air-to-air thermoelectric heat pump: 1—Peltier thermoelectric element; 2—hot-circuit air radiator fins; and 3—cold-circuit air radiator fins; A is radiator base thickness; B is air radiator size in the direction perpendicular to the fin plane; b is the fin thickness; H is the fin height; h is the distance between the adjacent fins; L is air radiator size in the line of the fin plane.
Agriculture 14 00922 g007
Table 1. Thermoelectric module specifications.
Table 1. Thermoelectric module specifications.
Module TypeInput Voltage, VInput Current, AMax. Temperature Difference of the Two Sides, °CMax. Power Consumption, WDimensions, mmWeight, g
TEC1-2281824167036050 × 50 × 435
Table 2. Parameters of apples before and after drying in the thermoelectric drying unit.
Table 2. Parameters of apples before and after drying in the thermoelectric drying unit.
Before DryingAfter Drying
Pallet No.Weight of Pallet and Apples, gPallet Weight, gWeight of Apples, gWeight of Pallet and Apples, gWeight of Apples, gWeight of Evaporated Water, gAmount of Evaporated Water, %
1446.4171.6274.8235.764.1210.776.67
2438.5170.4268.1233.362.9205.276.54
3420.1173.4246.7225.351.9194.878.96
4462.3172.4289.9236.464225.977.92
5444.6175.4269.2233.858.4210.878.31
Total:2211.9863.21348.71167.23041044.7
Table 3. Parameters of apples before and after drying in convective-type dryer ROTOR SH-002.
Table 3. Parameters of apples before and after drying in convective-type dryer ROTOR SH-002.
Before DryingAfter Drying
Pallet No.Weight of Pallet and Apples, gPallet Weight, gWeight of Apples, gWeight of Pallet and Apples, gWeight of Apples, gWeight of Evaporated Water, gAmount of Evaporated Water, %
1623.1252.6370.435198.427273.43
2593.2252.4340.6353100.624070.46
3634.0252.0382.037712525767.28
4618.9252.3366.7387134.723263.27
5583.1251.9331.1381129.120261.01
Total:30521261.21790.81849587.81203
Table 4. Comparison of household convective-type dryers in terms of energy consumption per 1 kg of evaporated water for the apple fruit drying process.
Table 4. Comparison of household convective-type dryers in terms of energy consumption per 1 kg of evaporated water for the apple fruit drying process.
Household DryerPower Consumed from the Electric Grid, WNumber of PalletsEnergy Consumption, kW·h per 1 kg Evaporated Moisture (Calculated Data)
1Veterok-260052.6
2Hyundai HYFD-S1202500122.5
3Vitek VT 505430052.6
4Redmond RFD-015925052.5
5Kitfort KT-190325052.6
6Masterica15052.8
7ROTOR SH-00252052.8
8Laboratory sample24052.2
Table 5. Specifications of the thermoelectric drying unit.
Table 5. Specifications of the thermoelectric drying unit.
ParameterUnitIndicator Values
Theoretical ValuesTest Data
Max. power consumed from the electrical gridW240237
Heat returned by the unit, at leastW55.852.8
Input voltageV220219
Input voltage of one thermoelectric Peltier elementV2019
Number of thermoelectric Peltier elementspc11
Material (product) volume to be driedl109.6
Drying agent (air) max. temperature°C7067
Average product (apple fruits) processing time for initial and final moisture content of 85% and ~22%, respectivelyh87.5
Overall unit dimensionsm1.0 × 0.7 × 0.061.0 × 0.7 × 0.06
Max. unit weightkg76.7
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Tikhomirov, D.; Khimenko, A.; Kuzmichev, A.; Budnikov, D.; Bolshev, V. Raising the Drying Unit for Fruits and Vegetables Energy Efficiency by Application of Thermoelectric Heat Pump. Agriculture 2024, 14, 922. https://doi.org/10.3390/agriculture14060922

AMA Style

Tikhomirov D, Khimenko A, Kuzmichev A, Budnikov D, Bolshev V. Raising the Drying Unit for Fruits and Vegetables Energy Efficiency by Application of Thermoelectric Heat Pump. Agriculture. 2024; 14(6):922. https://doi.org/10.3390/agriculture14060922

Chicago/Turabian Style

Tikhomirov, Dmitry, Aleksei Khimenko, Aleksey Kuzmichev, Dmitry Budnikov, and Vadim Bolshev. 2024. "Raising the Drying Unit for Fruits and Vegetables Energy Efficiency by Application of Thermoelectric Heat Pump" Agriculture 14, no. 6: 922. https://doi.org/10.3390/agriculture14060922

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop