Compressed-Sensing-Based Time–Frequency Representation for Disturbance Characterization of Maglev On-Board Distribution Systems

Electronics 2020, 9(11), 1909; https://doi.org/10.3390/electronics9111909
by Lu Xing 1,2, Yinghong Wen 1,2, Shi Xiao 3, Jinbao Zhang 1,2 and Dan Zhang 1,2,*
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Electronics 2020, 9(11), 1909; https://doi.org/10.3390/electronics9111909
Submission received: 18 October 2020 / Revised: 7 November 2020 / Accepted: 11 November 2020 / Published: 13 November 2020
(This article belongs to the Special Issue Advances in Low-Frequency Noise Measurements)

Round 1

Reviewer 1 Report

Good day,

I am glad that I could review this article. My only comment is about Figure 3, where the experimental setup has been shown. In my opinion the image is too small and the resolution is also low so it is hard to analyze. I suggest to increase both the resolution and the size. I think that individual image of the "On-board distribution system controlling unit" would be helpfull too.

In my oppinion the paper is well prepared and it can be published in its current form. However, I would be very glad if Authors thought over my comment about figure 3.

Best Regards

Author Response

Dear Reviewer,

Thanks for your review and kindly comments on our paper. We've replace Figure 3 in the revised version. An individual image of on-board distribution system controlling unit is added and the figure is presented with an enlarged size. We are sorry that the image resolution may not be increased due to the camera performance. We hope this revision would be helpful for a deeper insight of the experimental platform.

Best Regards,

Lu Xing

Reviewer 2 Report

  1. Can you add a conclusion?
  2. In page 2 end of line 65, names missing?  xyz et al.
  3. Page 10, Figure 7(b) x-axis label missing. It is Frequency (Hz)
  4. For normalised voltages, what were the maximum values and are they acceptable for insulations of practical systems?
  5. What conclusions you have generally for power quality on both side of the circuit in transition times?
  6. Line 42 has  not have
  7. Line 47, space before [18]
  8. Line 57 space before [22-24]
  9. Many places need comma, especially after However,

Author Response

Dear Sir/Madam,

Thanks a lot for your reviewing and valuable comments. We've revised our paper according to your comments and answered your questions, please find the response letter in attachment.

Regards,

Lu Xing