Next Article in Journal
Neutron Stars in the Symmetron Model
Next Article in Special Issue
Digging into Axion Physics with (Baby)IAXO
Previous Article in Journal
Underground Measurements of Nuclear Reaction Cross-Sections Relevant to AGB Stars
Previous Article in Special Issue
NuFIT: Three-Flavour Global Analyses of Neutrino Oscillation Experiments
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Design of New Resonant Haloscopes in the Search for the Dark Matter Axion: A Review of the First Steps in the RADES Collaboration

by
Alejandro Díaz-Morcillo
1,*,
José María García Barceló
1,
Antonio José Lozano Guerrero
1,
Pablo Navarro
1,
Benito Gimeno
2,
Sergio Arguedas Cuendis
3,
Alejandro Álvarez Melcón
1,
Cristian Cogollos
4,
Sergio Calatroni
3,
Babette Döbrich
3,
Juan Daniel Gallego-Puyol
5,
Jessica Golm
3,6,
Igor García Irastorza
7,
Chloe Malbrunot
3,
Jordi Miralda-Escudé
4,8,
Carlos Peña Garay
9,10,
Javier Redondo
7,11 and
Walter Wuensch
3
1
Department of Information and Communications Technologies, Universidad Politécnica de Cartagena, 30202 Cartagena, Spain
2
Instituto de Física Corpuscular (IFIC), CSIC-University of Valencia, 46071 Valencia, Spain
3
European Organization for Nuclear Research (CERN), 1211 Geneva, Switzerland
4
Institut de Ciències del Cosmos, Universitat de Barcelona (UB-IEEC), 08028 Barcelona, Spain
5
Yebes Observatory, National Centre for Radioastronomy Technology and Geospace Applications, 19080 Guadalajara, Spain
6
Institute for Optics and Quantum Electronics, Friedrich Schiller University Jena, 07743 Jena, Germany
7
Center for Astroparticle and High Energy Physics (CAPA), Departamento de Física Teórica, Universidad de Zaragoza, 50009 Zaragoza, Spain
8
Institució Catalana de Recerca i Estudis Avançats, 08028 Barcelona, Spain
9
Institute for Integrative Systems Biology (I2SysBio), CSIC-University of Valencia, 46071 Valencia, Spain
10
Laboratorio Subterráneo de Canfranc, 22880 Canfranc Estacion, Spain
11
Max-Planck-Institut für Physik (Werner-Heisenberg-Institut), 80805 Munich, Germany
*
Author to whom correspondence should be addressed.
Universe 2022, 8(1), 5; https://doi.org/10.3390/universe8010005
Submission received: 27 November 2021 / Revised: 18 December 2021 / Accepted: 19 December 2021 / Published: 23 December 2021
(This article belongs to the Special Issue Studying the Universe from Spain)

Abstract

:
With the increasing interest in dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of developing very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years: from the first designs—based on the multi-cavity concept, aiming to increase the haloscope volume, and thereby improve sensitivity—to their evolution, data acquisition design, and finally, the first experimental run. Moreover, the envisaged work within RADES for both dipole and solenoid magnets in the short and medium term is also presented.

1. Introduction

Since Peccei and Queen established a mechanism to solve the strong Charge–Parity (CP) problem [1,2], and subsequently Weinberg [3] and Wilczek [4] predicted the existence of a new particle, the axion, the defining and execution of different experimental setups in order to detect this proposed particle have gained an increasing interest. In addition, soon after their proposal, axions were acknowledged to be ideal dark matter (DM) candidates, due to non-thermal production channels in the early Universe that are directly expected from the very Peccei–Quinn mechanism [5,6,7]. More recently, due in part to the persistently negative outcomes of the many worldwide efforts to detect weakly interacting massive particles (WIMPs), the favorite DM candidate for the last three decades, the axion DM hypothesis, has been attracting more interest in the experimental community.
Apart from their gravitational interaction with normal matter, axions are also expected to have a weak electromagnetic (photons) and Dirac fermionic (e.g., nucleons or electrons) coupling. In this work, we focus on the axion coupling into two photons given by
L a γ γ g a γ a E · B e ,
where g a γ = α g γ / 2 π f a is the axion–photon coupling coefficient, α the fine structure constant, f a the axion decay constant, and g γ a model dependent dimensionless coupling constant. E · B e is the scalar product of the electric field and an externally applied magnetic field, and a the axion field.
In the last thirty years, the search based on axion–photon coupling has been developed following three different detection techniques, depending on the sources of these particles and their expected masses. Two of them, based on the inverse Primakoff effect [8], the so called axion helioscopes and haloscopes, were proposed by Sikivie [9] in the mid-80s. The other one, known as Light Shining through Walls (LSW) [10,11,12] is based on both direct and inverse Primakoff effects. Helioscopes and haloscopes detect axions from external sources (the sun or relic axions), whereas LSW generates axions by itself.
The LSW uses two Fabry–Perot cavities separated by an optical barrier. Axions are generated in the first cavity and detected in the second. Both generation and detection are through the coupling between photons and axions.
Helioscope experiments look for axions produced in the Sun through the Primakoff effect from plasma photons in the solar inner layers. After initial experiments at Brookhaven National Laboratory (BNL) in 1992 [13] and in Japan in the SUMICO experiment [14,15,16], the third-generation CAST experiment at CERN obtained the best results in this kind of detection up to now, with limits for axion–photon coupling < 6.6 × 10 11 GeV 1 in the mass range <0.02 eV [17], and < 2.3 × 10 10 GeV 1 for 0.02 eV < m a < 0.64 eV [18]. The future of solar axion searching will star IAXO [19].
The quest for dark matter in the form of axions brings up the idea of a haloscope experiment. In 2016, the RADES (Relic Axion Detector Exploratory Setup) collaboration started, joining research groups from universities and research institutes of Spain and researchers at CERN. A detailed state-of-the-art report of the different axion detection experiments, finished or under development and execution, can be found in [20]. Updated and comprehensive reviews can be found in [21,22,23]. The aim of the collaboration was the detection of the axion in our galactic halo, which is, in fact, a candidate for constituting dark matter [6,7]. Therefore, the experiment should be clearly based on a haloscope setup. Haloscope experiments intend to detect axions in the galactic halo by promoting the axion–photon conversion under a strong magnetic field. The intensity of the electromagnetic field is boosted when this conversion occurs in a resonant device, such as a microwave resonant cavity. Additionally, due to the expected extremely low axion–photon coupling, and thus the electromagnetic power to be detected, it is mandatory to work in cryogenic conditions in order to minimize the thermal noise, and thus to increase the signal to noise ratio ( S N ).
At the beginning of the RADES collaboration, the successful experiment ADMX had already completed the exploration in the 1.9–3.65 μeV mass range (460–890 MHz) with exclusion limits that reached those of the KSVZ model [24]. It benefited from the experience of two pioneering experiments at BNL [25] and the University of Florida [26], respectively. The prospects for the new version of the experiment (ADMX-Gen2) reach even DFSZ sensitivity in the 1.4–25 μeV mass range [24].
Since the RADES project began, the research with resonant cavity haloscopes has greatly increased, with a large number of new cavity concepts, such as the KLASH proposal [27] at lower masses than ADMX; and HAYSTACK [28], ORGAN [29], QUAX [30], and CAPP experiments [31] at higher ones. RADES [32] is among this latter group.

2. General Principles in Resonant Haloscope Design

As described in [32] for the RADES case, a resonant haloscope experiment consists of a resonant cavity immersed in a high and static magnetic field at very low temperatures (few K or even mK), and connected to a receiver or data acquisition system (DAQ) which must amplify/filter/down-convert the detected signal without introducing too much noise and perform the A/D conversion and subsequent fast Fourier transform (FFT) for a proper offline data analysis.
We can summarize the main goals in the design of an axion detection experiment in (1) maximizing the electromagnetic power detected from the axion–photon coupling, (2) optimizing the sensitivity of the experiment, and (3) maximizing the scanning rate along the mass range of interest. It is of key interest, thus, to know the relations of these three parameters with the experimental variables.

2.1. Detected Power

In a resonant cavity haloscope experiment, the power generated in the axion–photon conversion can be obtained as [33]
P g = g a γ 2 ρ a m a B e 2 C V m i n ( Q c , Q a ) ,
or more accurately [34],
P g = g a γ 2 ρ a m a B e 2 C V Q c Q a Q c + Q a
where g a γ is the unknown axion–photon coupling in (1); ρ a the axion dark matter density; m a the axion mass; B e the static magnetic field; V the cavity volume; Q a and Q c the quality factors of the axion and cavity resonances, respectively; and C the form or geometric factor, a normalized parameter that quantifies the coupling between the static magnetic field B e and the dynamic electric field E induced by the axion–photon conversion:
C = | V E · B e d V | 2 V | | B e | | 2 d V V ε r | | E | | 2 d V
where simple bars | · | indicate the magnitude of a complex number, double bars | | · | | are the standard vector norm defined in the 3D complex vector space, and ε r is the dielectric constant inside the cavity.
This generated power will be in part dissipated in the lossy material of the cavity (metallic walls if there are no lossy dielectric materials) and in part extracted from the cavity with a proper probe. This coupling, for frequencies below the millimetric wave range, will be normally a monopole or loop antenna, depending on the mode to be extracted, connected to a coaxial line which, in turn, transmits the signal to the receiver. The power detected at the coaxial port is
P d = κ g a γ 2 ρ a m a B e 2 C V Q l Q a Q l + Q a
where κ is the coupling factor at the extraction point, and Q l is the loaded quality factor, that is, the quality factor of the cavity taking into account the coupling effect. Maximum power transfer is obtained in a critical coupling regime, that is, for κ = 0.5 . Although critical coupling can be designed, it is very sensitive to slight mechanical or temperature changes. Therefore, it is very convenient to develop mechanical or electromagnetic systems for modifying the coupling in situ.
Moreover, if Q l is much lower than Q a (∼ 10 6 ), (5) becomes
P d = κ g a γ 2 ρ a m a B e 2 C V Q l

2.2. Axion Coupling Sensitivity

The complete experiment, using a source (resonant haloscope) and a receiver, has a signal to noise ratio given by Dicke’s radiometer equation:
S N = P d P N = P d k B T s y s Δ v Δ t
where k B is the Boltzmann constant, T s y s the noise temperature of the system, Δ t the observation time, and Δ v the reception bandwidth, which should coincide with the bandwidth of the axion resonance:
Δ v a = m a Q a
By introducing (6) and (8) into (7) we can obtain the expression for the axion–photon coupling:
g a γ = S N k B T s y s κ ρ a C V Q l 1 2 1 B e m a 3 Q a Δ t 1 4
An alternative parameter to g a γ is the dimensionless axion–photon coupling C a γ , related to g a γ through
C a γ = 5 × 10 15 g a γ G e V 1 m a μ e V
Introducing (9) into (10) yields
C a γ = 5 × 10 15 S N k B T s y s κ ρ a C V Q l 1 2 1 B e 1 Q a m a Δ t 1 4
As seen in (5), the detected power only depends on intrinsic parameters of the axion ( g a γ , ρ a , m a , and Q a ) and experimental parameters in the cavity subsystem ( B e 2 , C, V, and Q l ), but the sensitivity also relies on receiver experimental parameters ( S N , T s y s , and Δ t ).

2.3. Scanning Rate

Despite its high-Q resonant behavior, the final aim of a cavity haloscope is exploring the largest possible mass range and doing it quickly. The mass sweeping can be performed by adequate moving mechanisms or tuning materials that modify the cavity’s resonant frequency, and the scanning rate d m a d t is usually referred to as a figure of merit of the haloscope.
For a measurement with the cavity resonance centered at m a , the mass range explored is the bandwidth of the cavity:
d m a = m a Q l
and the time needed for that measurement in order to get a prescribed S N is, from (7),
d t = Δ v a S N k B T s y s P d 2 = m a Q a S N k B T s y s P d 2
Therefore,
d m a d t = Q a Q l P d S N k B T s y s 2 = Q a Q l κ 2 g a γ 4 ρ a m a 2 B e 4 C 2 V 2 S N k B T s y s 2

3. Motivation and Constraints of the RADES Project

As a summary of the last section, the experimental parameters that optimize the detected power, the sensitivity, and the scanning rate can be identified in (6), (11) and (14), respectively. On the cavity side, it is evident that the most important parameter is the external magnetic field B e , followed by the volume and the loaded quality factor of the cavity, the form factor for the axion-coupling electromagnetic mode, and the noise temperature of the system, which, due to the Friis formula [35], is mainly determined by the physical temperature of the cavity and the noise temperature of the first amplifier.
A figure of merit for the magnet in this kind of experiment is the magnetic volume B e 2 V . However, it is usually difficult to design a haloscope that fills completely the available volume, so the potential of the magnet is underused. This was the main motivation of the RADES project. Taking into account the upper limit for the ADMX prospects in the next few years [24], RADES aimed to explore higher masses, but these lead to smaller resonant cavities, since the resonant frequency depends, in general, inversely on the dimensions of the cavity.
For instance, continuing with the ADMX case, the resonant frequency of a circular cavity for TM modes is given by
f T M n l q = c 2 π p n l a 2 + q d 2
where n, l, and q are the numbers of variations in azimuthal, radial, and axial coordinates, respectively; c is the speed of light; p n l is the l-th root of the first-kind Bessel function of order n; and a and d are the radius and length of the cavity, respectively. For the T M 010 mode used in the ADMX experiment and an expected exploration mass of 30 μeV (7.25 GHz) the cavity diameter should be 3.17 cm, which would underuse the available 60 cm bore.
Most haloscope experiments, such as ADMX and HAYSTACK, use solenoid magnets. These magnets produce an axial ( z ^ ) magnetic field (Figure 1 right), and therefore, the usual configuration for the cavity is a circular cavity with its axis parallel to the magnet bore axis. In this way, a TM mode, whose electric field is also axial, yields an optimal form factor. In the case of the RADES project, strong accelerator dipole magnets (Figure 1 left) were available in the initial stages, concretely the CAST magnet, which yields a 8.8 T transverse ( y ^ ) magnetic field. A more convenient cavity for this kind of magnet is the rectangular cavity, where T E m 0 p modes have vertical polarization for the electric field.
For a rectangular cavity, the resonant frequencies for both TE and TM modes are given by
f m n p = c 2 m a 2 + n b 2 + p d 2
where m, n, and p are the sinusoidal variations of the mode in the x, y, and z dimensions, respectively; a is the width, b the height, and d the length of the cavity.
In this case, for the mode with a maximum form factor, that is, the T E 101 mode, a mass goal of 30 μeV, and to get the maximum volume ( a = b = d ), the cavity should be a hexahedron with a = 29.3 mm. This fits with the 42.5 mm diameter of the bore in the CAST magnet [36], but the magnet is greatly underused if we compare the length of the cavity with the 9.3 m of the bore. Additionally, in order to separate degenerate modes, a and b must be sensibly different (let us assume a 2 b ). This reduces the cross-section of the cavity, and with it, its volume.
Taking this into account, and despite the fact that a rectangular cross-section is not the best way to maximize the use of a circular cross-section, the RADES project driving motivation was increasing the volume of the cavity in the axial direction without modifying the resonant frequency and other associated parameters, such as Q l and C.

3.1. First Attempt: Increasing the Length of the Cavity

Obviously, after a quick glimpse to (16), the first idea for increasing the volume without modifying the resonant frequency is increasing the cavity length. For the T E 101 mode, (16) is simplified to
f T E 101 = c 2 1 a 2 + 1 d 2
Thus, if a d the length can be increased without modifying the resonant frequency, since f T E 101 c 2 a . This approach has a minor drawback: the reduction in a (and, obviously in b to keep a 2 b ) reduces the cavity cross-section, and this contributes to a reduction of part of the volume gained with the larger d. Anyway, this reduction is small compared with the increase due to d increment, as the following example shows.
Let us assume arbitrarily a goal exploration mass of 34.76 μeV (8.4 GHz). For the T E 101 mode, fixing a = d in (17) leads to a = 22.86 mm, and fixing d = 10 a yields a = 17.95 mm. Increasing d up to 500 a just decreases the resonant frequency by less than 0.5 % and increases the volume by a factor 242 with respect to the a = d case. This long cavity ( 17.95 × 8.97 × 8975 mm) can be operated in one of the two CAST magnet bores (43 mm in diameter and 9.3 m in length).
The great drawback of this length increment is the clustering of higher resonant modes T E 10 p close to the chosen axion-coupling mode ( T E 101 ) [37]. Figure 2 shows the spectrum of the cavity around 8.4 GHz for different lengths. If the nearest higher mode ( T E 102 ) is too close to T E 101 , it can hinder the characterization of Q l of the constructed cavity, as well as the coupling factor κ .

3.2. The Alternative: Multi-Cavity Concept

Multi-cavity structures are widely used in filtering for telecommunication applications in the range of microwaves and millimeter waves. In that context, the aim is realizing a band pass filter with a given mask which prescribes the pass band, the stop band, the pass ripple, and the stop band attenuation. Different references [38,39] deal with the analysis and design of this kind of structure.
In our context, the objective is the design of a very selective filter (high Q l ), centered on the resonant frequency of interest, with a large volume and with a mode that couples optimally with the external magnetic field in order to maximize the form factor. The mathematical formalism for the analysis and design of this kind of multi-cavity device is presented in [32].
As explained there, roughly speaking, if the cavities have the same dimensions, the resonant frequency of the haloscope is that of the cell cavity, whilst the volume is the sum of volumes of the cell cavities. This means that, by designing properly a haloscope of N cavities, the volume is multiplied by N whilst the resonant frequency remains that of a single cavity. Moreover, as explained in [32], the quality factor of the haloscope must be approximately the same as that of the unit cavity, and the optimal external coupling factor κ = 1 2 can be obtained by extracting the signal from any of the cavities.
Assuming that other modes are sufficiently far from the T E 101 mode, all cavities will resonate in that mode, but the whole device can have different mode configurations, depending on the couplings between neighboring cavities. The chosen mode configuration will be that which maximizes the form factor, which will be the configuration with all positive (or all negative) electric fields in the cavities. This allows a constructive sum in the term | E · B e d v | 2 of the factor form (4). In fact, it is expected that the total form factor will be approximately the same as one of the unit cavities, which for the T E 101 can be obtained analytically from (4) as
C T E 101 = | sin π x a sin π z d d x d y d z | 2 V sin 2 π x a sin 2 π z d d x d y d z = 64 π 4
This multi-cavity concept is very close to the idea of coherently summing N signals extracted from N identical cavities, but with only one compact device and avoiding the difficulty of conserving the coherence (in-phase signals) in the combining device. Other multi-cavity concepts for axion detection have been published in the last few years [40,41].
Figure 2. Cavity (17.95 × 8.97 cross-section) spectrum around 8.4 GHz for d = 10 a (blue) and d = 100 a (red). Simulation results from CST Studio Suite [42].
Figure 2. Cavity (17.95 × 8.97 cross-section) spectrum around 8.4 GHz for d = 10 a (blue) and d = 100 a (red). Simulation results from CST Studio Suite [42].
Universe 08 00005 g002
In RADES, the coherent construction of the all-positive electric field configuration is obtained through the proper design of the internal couplings. These couplings between neighboring cavities can be realized, in the simplest way, with rectangular irises, such as those shown in Figure 3. Due to the vertical polarization of the T E 101 electric field, irises invariant in y (Figure 3 left) have an inductive behavior, whilst those invariant in x (Figure 3 right) have a capacitive behavior.

4. First Multi-Cavity Haloscopes

4.1. All Inductive 5-Cavity Haloscope

During 2017, the first RADES haloscope was designed, manufactured, characterized, and finally used in the 2018 data-taking campaign in CAST. It was the fivefold cavity shown in Figure 4 and presented in [32]. Dimensions, as described in Figure 4, are listed in Table 1.
This device was designed first through the formalism in [32], and was finally optimized with CST Studio [42]. Figure 5 shows the five different configurations of the mode T E 101 for the final five-cavity structure, and the corresponding form factors.
Occasional quenches produced in the CAST magnet made necessary a strong material for the haloscope in order to avoid deformations in the device. For that reason, the base material was not copper, but non-magnetic stainless steel 316LN, plated with a 30 μm of copper layer for reducing the losses. The transmission coefficient magnitude, both simulated and measured at the operation temperature of 2 K, is depicted in Figure 6.

4.2. Alternate Coupling

Although the multicavity concept alleviates the mode clustering, it has also a limit. N cavities produce N different configuration patterns for T E 101 mode. Therefore, when the number of cavities increases, the same concentration of resonances is observed. Figure 7 shows the 30 configurations of a 30-cavity haloscope with a similar design to the 5-cavity one, i.e., inductive irises. Figure 8 shows the spectrum of this device with these resonances.
As observed, the first (axion one) and the second T E 101 mode configurations are very similar. This situation worsens with the manufactured device and data-taking conditions, leading normally to an overlapping of both resonances, which makes it impossible to obtain the quality factor or the coupling factor from measurements.
For an all-capacitive coupling, the patterns and spectrum are shown in Figure 9 and Figure 10, respectively. In both spectrums, thirty modes can be seen (not by eye due to numerical accuracy from the software). However, there is a main difference between them: for the all-inductive structure, the axion mode is the first peak, whereas for the all-capacitive structure, the axion mode is the last one (30th mode). Note that in both cases, the axion mode is at the same frequency (∼8.43 GHz). The reason comes from the design parameters employed to set such an axion search at that specific frequency.
The solution to avoid the mode-mixing close to the axion mode is to apply alternated couplings: capacitive + inductive irises [43]. In this configuration the axion mode is at the middle of the band, where greater mode separation exists. The first haloscope designed and manufactured with this alternating concept was a 6-cavity structure (Figure 11 (top)), followed by a 30-cavity structure based on the same idea (Figure 11 (bottom)). Figure 12 shows the thirty E-field patterns of this last haloscope, the sixteenth configuration being the most adequate for the axion–photon coupling, that is, with maximum form factor. The spectrum of this structure in the frequency range of interest is shown in Figure 13, where an improvement regarding the mode-mixing can be observed. Concretely, the alternate coupling allows a 32-fold greater separation between the axion mode and the closest neighbor (from Δ f a l l i n d u c t i v e = 470 KHz to Δ f a l t e r n a t e d = 15.34 MHz).

5. Data Acquisition System

The setup for the experiment is shown in Figure 14. The cavity was placed inside one of the bores of the Large Hadron Collider (LHC) ring section prototype placed at CAST. A low noise amplifier (LNA) TXA4000 from TTI Norte [44] provided a 40 dB gain in the 8–9 GHz frequency band and was placed inside a copper vessel in the cryogenic section limited by flange 1. Then a thermal transition required thermal plates to adapt the cables from the cryogenic section to room temperature. Port 1 of the haloscope was designed to obtain critical coupling while port 2, which was weakly coupled, provided information at the calibration stage about the working frequency and the correct operation of the amplifier, which needed a special bias. Temperature and bias cables were made of phosphor bronze from Lake Shore Cryotronics [45] to avoid thermal leakages. Radiofrequency (RF) cables were 3.5 mm semirigid coaxial copper from Micro-coax [46]. Connectors were SubMiniature version A (SMA).
The signal from port 1 was the input of the analog acquisition module, which was a heterodyne receiver that down-converted the input RF signal to the intermediate frequency (IF) output frequency band. The main functional blocks of the analog acquisition module were (see Figure 15):
  • RF LNA: It amplified the input RF signal. It worked from 8 GHz to 9 GHz and provided a gain around 55 dB and 30 dB input return loss.
  • Single pole double through (SPDT) RF switch: This device allowed us to visualize the amplified RF signal at the test output port, or to directly check the down converter circuit.
  • Down converter: It down-converted the input signal from X band to a frequency band around 140 MHz. It was an image rejection mixer (IRM) which provided 26 dB of image band rejection.
  • Local oscillator (LO): It provided the frequency signal to convert the RF input signal to the 140 MHz band. Its working power level was 0 dBm working from 7860 to 8860 MHz.
  • IF filtering: This section filtered the desired IF signal from 134 MHz to 146 MHz. It consisted of two filters in series: a low pass filter (LPF) to reject the LO leakage from the IRM, and a surface acoustic wave (SAW) band pass filter (BPF) to select the wanted IF frequency band.
  • IF signal conditioning: This module amplified or attenuated the IF signal to provide the desired IF output level. Its function was to bring the IF signal to the best input level for the digital acquisition module. The amplification or attenuation level depended on the input RF signal power.
  • Power supply unit: This unit fed all the modules that formed the analog acquisition module.
The LO frequency was chosen to satisfy (19), taking into account the radio-frequency (frequency of the first appearing mode of the cavity).
IF ( MHz ) = RF ( MHz ) LO ( MHz )
(for instance, 140 MHz = 8400 MHz − 8260 MHz)
The digital acquisition module represented in Figure 16 was especially designed to process the IF signal to obtain the power spectra with an adequate dynamic range and frequency resolution. This is achieved by digitizing the signal with a 14 bit A/D converter and processing the data with a FPGA. The unit analyzes a total instantaneous bandwidth of 12 MHz around a central frequency of 140 MHz. This is performed by sampling with a clock frequency of 37.5 MHz and using an antialiasing filter centered in the eighth Nyquist zone (bandpass sampling). Then, the FFT is calculated with 8192 samples, obtaining a frequency resolution of 4577.6 Hz. The system is designed to integrate (average) a number of the power spectra internally to avoid unnecessary large data rates and file storage requirements in the external computer. A pre-integrated spectrum is sent every 0.44739 seconds to be further integrated by the data acquisition software.

6. First Results

In 2018 the 5-cavity haloscope described in Section 4.1 and the associated receiver were installed in the CAST magnet. The data-taking period went from the 30 October 2018 to the 20 December 2018. During this time, 432 h of magnet-on and 141 h of magnet-off data at different LO frequencies were taken. The reason for taking different LO frequencies will be explained later on in this section.
A typical power spectrum consisted of data integrated for 90.37278 s and is labeled a 90s spectrum. For the first results, two sets of magnet-on and two sets of magnet-off data were used. The magnet-on sets were taken at LO frequencies, l 1 = 8.240 GHz and l 2 on = 8.247 GHz, and contained 4093 and 2446 spectra, respectively. The magnet-off sets were taken at LO frequencies l 1 and l 2 off = 8.248 GHz, and contained 1047 and 702 spectra, respectively.
These 90s spectra (see Figure 17a) are combinations of the electronic background, the cavity resonance peak structure, thermal noise, and any possible axion signal. The unwanted electronic background and the cavity resonance structure were removed following these steps:
  • Dividing each 90s spectrum taken at l 1 by the average spectrum of l 2 on . This was a first-order correction to the electronic background introduced by the DAQ (see Figure 17b).
  • Limiting the frequency region of the analysis to a range of ∼ 0.87 MHz around the resonance peak (see Figure 17b). This range covered more than the full width at half maximum of the Lorentzian peak.
  • Applying a Savitzky-Golay (SG) filter [47,48] to the average spectrum of the 90s spectra taken at l 1 . The filter produced a fit labeled SG-fit (see Figure 17c).
  • Normalized spectra were created by dividing each 90s spectrum by the SG-fit (see Figure 17d).
  • Due to drifts in the receiver chain, the normalized spectra still had unwanted structure remaining within the spectra. A second SG-fit (SG*) was created for each normalized 90s spectrum. The spectra were divided by the SG*-fits, and the result was subtracted by 1 to create unit-less normalized power spectra (see Figure 17e).
  • The unit-less normalized power spectra were combined into a grand unified spectrum.
  • The previous steps were repeated for the magnet-off data sets.
  • The final spectrum was the difference of the magnet-on and magnet-off grand unified spectra (see Figure 17f).
In step 1, by changing the LO frequency, the resonance peak was displaced in the IF frequencies introduced in (19). However, the intrinsic background structure introduced by the DAQ remained qualitatively similar. The SG-fit of step 3 was constructed to remove large frequency scale features, such as the resonance peak; and the SG*-fits of step 5 removed time scale variations, such as the one produced by gain drifts.
Spectra produced after step 5 should be a combination of thermal noise and a possible axion signal. Thermal noise follows a Gaussian distribution, and the expected fluctuation of these spectra is given by:
σ = 1 t · Δ ν ,
where Δ ν is the resolution bandwidth of the DAQ (4577 Hz) and t is the integrated time of the power spectra. For t = 90 s, the theoretical σ = 0.001554 . The expected values of the pull distribution of a Gaussian distributed value are a mean value μ = 0 and a width of σ = 1 . The histogram of the pull distribution of the unit-less normalized power spectra was created, and a Gaussian distribution was fitted to it. The fit gave a mean value μ = 0.0002 ± 0.0009 and a width of σ = 1.0048 ± 0.0009 , which proved that at the 90 s fluctuation level, the background structure was removed. After combining the 103 h of magnet-on together, the pull distribution of the histogram of the grand unified spectrum showed an unexpected non-Gaussian structure with μ = 0.0 ± 0.2 and σ = 1.7 ± 0.2 .
This structure was identified as a systematic residual, which also appeared in the magnet-off data. Step 8 was done to remove this structure without affecting a possible axion signal. The fitted Gaussian function to the final spectrum yielded μ = 0.00 ± 0.08 and σ = 1.07 ± 0.08 . An axion search was done to this spectrum.
To perform the search, the axion line shape was created using the velocity distribution based of the standard isothermal spherical halo model [49]. The two SG-fits were applied to the line shape to replicate the effects of the background removal, steps 3 to 5. A signal attenuation of 20% and a distortion of the line shape were the results of applying the SG-filters. The resulting distorted line shape (which had a range of 16 frequency bins) was fitted through the 190 frequency bins of the final spectrum. The amplitude A given by the fit function represented the axion power deposited at each frequency. After applying the look-elsewhere effect [50], the highest A excess yielded a global significance of σ = 3.05 . Thus no significant signal above statistical fluctuations was observed.
Figure 17. Removal procedure of the electronic background. (a): The initial raw spectra taken by the DAQ are combinations of electronic background, the cavity resonance peak, white noise, and a possible axion signal. The electronic background and cavity resonance were removed by (b): dividing the spectra at different LO frequencies and (c,d): applying two SG filters. (e): The unit-less normalized spectra were combined into a grand unified spectrum. (f): The magnet-on and off grand unified spectra were subtracted to remove the systematic residual structure and create the final spectrum. Figures taken from [51].
Figure 17. Removal procedure of the electronic background. (a): The initial raw spectra taken by the DAQ are combinations of electronic background, the cavity resonance peak, white noise, and a possible axion signal. The electronic background and cavity resonance were removed by (b): dividing the spectra at different LO frequencies and (c,d): applying two SG filters. (e): The unit-less normalized spectra were combined into a grand unified spectrum. (f): The magnet-on and off grand unified spectra were subtracted to remove the systematic residual structure and create the final spectrum. Figures taken from [51].
Universe 08 00005 g017
The Bayesian method [50] was used to compute the upper limit (UL). The fact that a possible axion signal would appear as a positive A value on the fit function was used as the prior for the posterior function. The likelihood function of the normalized power excess values of the final spectrum can be expressed with a χ 2 distribution because the variable was Gaussian distributed. The UL of A ( A U L ) was computed integrating over the posterior function, as shown in the following equation:
1 N 0 A UL e ( χ 2 / 2 ) d A = 1 α ,
where 1 − α is the credibility level (CL) of the UL. For these results a 95% CL was used. The unit-less A U L can be converted back to power units with:
P d = A UL · P N = A UL k b T sys Δ ν ,
and with (6) one can compute the exclusion limit to axion–photon coupling g a γ of this measurement.
To evaluate (6) and (22), the external parameters of the system were measured. For the T sys , the Y-method [52] was followed: the loaded Q-value was computed using Q l = f / Δ f where f was the resonant frequency of the cavity’s first mode and Δ f was the resonance width. The cavity coupling was measured using the reflection coefficient S 11 1. The geometric factor and volume were taken from simulations. The resolution bandwidth was determined by the DAQ specifications described in Section 5; the standard dark matter density value used by other axion haloscope experiments was used to enable comparisons with other results. The magnetic field was provided by the CAST collaboration. Finally, an attenuation factor ( η ) had to be included to account for the losses between the cavity and the LNA.
Table 2 lists the values for all the parameters needed to compute g a γ . An exclusion limit with a 95% credibility level on the axion–photon coupling constant of g a γ 4 × 10 13 GeV−1 over a mass range of 34.6738 μeV < m a < 34.6771 μeV was achieved. This constitutes a significant improvement over the current strongest limit set by CAST at this mass. A detailed description of the first results can be found in [51]. Figure 18 compares the CAST-RADES results with other haloscopes experiments and CAST’s solar axion results.

7. Envisaged Work

After the encouraging results of these first few years, the collaboration is currently and will be in the next years focusing on increasing the sensitivity of the experiment, on increasing the mass range by means of tuning mechanisms or materials, on developing new haloscopes for other mass regions, and on developing computational techniques which can efficiently obtain an accurate solution for the electromagnetic field induced by the axion–photon interaction. Next, these future goals are briefly described.

7.1. Increasing the Experiment’s Sensitivity

As said before, the experiment’s sensitivity, in terms of the haloscope parameters, depends on its volume, its quality factor, and its coupling to the line which extracts the signal generated by the axion–photon conversion.
The volume can be greatly increased if many cavities are used. Since our operation mode is the T E 101 , the detection frequency is independent of the cavity height, depending only on its width and length. In this way, the haloscope height can be increased until it reaches the magnet bore diameter. However, mode clustering around the T E 101 mode will appear due to the new resonant T E 1 n 1 and T M 1 n 1 modes (with n = 1 , 2 , 3 , . . ) for very large numbers of cavities. We are now studying the proper combination of different ports of the haloscope that can alleviate this clustering and make possible this increase in volume without distorting the mode T E 101 resonance.
Moreover, the multi-cavity concept can be used in other dimension, creating 2D multi-cavities, which not only increase their volume and exploit the magnet’s bore room, but also are able to introduce transmission zeros into the haloscope response for the rejection of unwanted cavity modes.
Regarding the improvement of the quality factor, a considerable increase in the experiment sensitivity is expected from the use of superconductive materials, and we recently manufactured a few cavities with the specific purpose of verifying the potential of this technology. The design of these new cavities is specifically tailored to allow soldering high-temperature superconductor (HTS) coated tapes of commercial production on the cavity surface. These tapes are optimized for magnetic flux pinning and are thus ideal for operation in a strong magnetic field. Measurement of a first prototype covered with such HTS tapes has shown a more than 50% improvement in quality factor compared to copper, when tested at 4.2 K in a magnetic field up to 11.5 T [53]. Further improvements in the soldering process have already been identified and are under testing, which should allow reaching even higher performance.
Finally, as remarked before, the sensitivity of the coaxial cavity coupling with the position, dimensions, and shape of the probe makes it advisable to develop mechanical systems for modifying this coupling in situ and get the desired critical coupling. This moving coupling system is mandatory when a frequency range is explored by tuning the haloscope properly. The collaboration is currently designing the moving coupling system with nanopositioners. For the tuning system, both mechanical and electromagnetic mechanisms, based on ferroelectric and ferromagnetic materials, are being studied.

7.2. Haloscopes for Other Frequencies

As described above, the first four years of the RADES collaboration have been focused on developments for the 34–35 μeV mass range (8.2–10.6 GHz frequency range). However, the possibility of operation in future magnets has meant that part of the work of the collaboration is nowadays devoted to the design of haloscopes in two far regions regarding this.
First, the future BabyIAXO magnet [54,55], a first step of the IAXO experiment [19], with two bores of 70 cm in diameter and 10 meter in length, allows one to test new bi-dimensional multi-cavity concepts in order to increase the volume in other dimensions. Additionally, even more importantly, this magnet has enough volume to even host single cavities for searching in the 1–2 μeV mass range (240–480 MHz, the lower limit of UHF band). These masses are just below the region explored by ADMX currently. With a 2 T magnetic field, BabyIAXO will be able to not only develop helioscope searches, but also haloscope experiments with a figure of merit ( B 2 V ) of 15.5 T2m3, a great leap from 0.014 T2m3 in CAST. Currently, RADES is designing these new cavities that profit from the large volume in BabyIAXO.
Second, the Canfranc Underground Laboratory (LSC) will have at the end of 2022 a dilution cryostat working at 10 mK with a 10 T solenoid magnet, and this opens up possibilities of continuing with the development of multicavities in X band, adapted to a solenoid magnetic field direction, with an improved noise temperature, and additionally, working on haloscopes in a theoretically well motivated region for searching the axion, the 310–455 μeV (75–110 GHz, W band). Both experiments will need detection devices that exploit the ultra-low temperatures and go beyond the standard quantum limit, such as Josephson parametric amplifiers (JPA), superconducting qubit-based single photon counters, or for higher frequencies, kinetic inductor devices (KID).

7.3. Developments in Numerical Simulation: Application of the BI-RME 3D Method to Axion-Photon Coupling in Resonant Cavities

The Boundary Integral Resonant Mode Expansion 3D (BI-RME 3D) [56,57] is a full-wave modal method based on classical numerical techniques used for electromagnetic analysis. The BI-RME 3D method, developed during the eighties and nineties, provides an exact formulation which allows one to calculate the electromagnetic field existing in a lossy microwave resonator in terms of the electric and magnetic charge and current densities.
By applying the BI-RME 3D method to the axion field, it is possible to obtain the complete information of the extracted signal from the cavity while taking into account not only the cavity shape, but also metallic and dielectric materials. This knowledge could be useful for further experiments or analysis in which the axion phase plays an important role, in particular when several waveguide ports are included in the analysis, avoiding the typical Cauchy–Lorentz approximation [33].
In summary, we envisage a new approach to calculate the extracted and dissipated power using a semi-analytical solution through the BI-RME 3D method, obtaining the frequency spectrum of the electromagnetic axion field generated inside the cavity. This rigorous broadband result could be of special interest in the cases where neighboring modes are quite close to the axion resonant mode and might interfere.

8. Conclusions

The RADES collaboration joined in 2016 the international quest for dark matter axion detection, and during the last five years has developed a new kind of resonant haloscope based on the multi-cavity concept. The multi-cavity technology increases the volume without introducing clustering of higher resonant modes near the signal mode, and thus increases the detection power and sensitivity to the axion–photon coupling constant. The multi-cavity concept was manufactured and tested for both inductive and alternated internal coupling, showing an improvement in the isolation of the axion mode in the second case. Based on data collected by RADES between the 30th of October and the 20th of December of 2018, the hypothesis of the axion–photon coupling constant of g a γ 4 × 10 13 GeV−1 is rejected at a significance of 95% over a mass range of 34.6738 μeV < m a < 34.6771 μeV. The future is full of new research possibilities for increasing the sensitivity of the experiment and for designing new haloscopes in lower (1–2 μeV) and higher (310–455 μeV) mass ranges, or for developing new computational techniques for obtaining rigorous electromagnetic solutions for the axion–photon coupling in resonant cavities.

Author Contributions

This review is a brief description of the work developed by the RADES researchers in the last five years. A.D.-M., A.J.L.G., B.G., A.Á.M., J.M.G.B. and P.N. have contributed to the haloscopes’ design, manufacturing and characterization, and the development of a computational technique, based on BIRME-3D, to model the axion-photon interaction in a resonant cavity; S.A.C., J.D.G.-P. and J.M.-E. to the data acquisition system and data analysis; I.G.I., B.D., C.P.G., C.C. and C.M. to the theoretical principles of the axion—photon interaction, the experiment definition and management at CERN; J.R. to the mathematical formalism for the multi-cavity concept; J.G. and S.C. to the characterization of high thermal superconducting cavities. and W.W. to haloscopes’ design, data analysis and experiment management. All authors have read and agreed to the published version of the manuscript.

Funding

This work has been funded by the Spanish Agencia Estatal de Investigación (AEI) and Fondo Europeo de Desarrollo Regional (FEDER) under projects FPA-2016-76978-C3-2-P (supported by the grant FPI BES-2017-079787) and PID2019-108122GB-C33, and was supported by the CERN Doctoral Studentship programme. The research leading to these results has received funding from the European Research Council under grant ERC-2018-StG-802836 (AxScale project). IGI acknowledges support from the European Research Council (ERC) under grant ERC-2017-AdG-788781 (IAXO+ project).

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Note

1
To measure the cavity coupling, an RF switch was installed after the data taking. Bypassing the LNA was thus not possible during data taking. The Q l measured after the installation of the switch was similar to the one computed during the data-taking period. From this result it can be assumed that the coupling measured before and after the data-taking period were the same.

References

  1. Peccei, R.D.; Quinn, H.R. CP conservation in the presence of pseudoparticles. Phys. Rev. Lett. 1977, 38, 1440–1443. [Google Scholar] [CrossRef] [Green Version]
  2. Peccei, R.D.; Quinn, H.R. Constraints imposed by CP conservation in the presence of pseudoparticles. Phys. Rev. D 1977, 16, 1791–1797. [Google Scholar] [CrossRef]
  3. Weinberg, S. A new light boson? Phys. Rev. Lett. 1978, 40, 223–226. [Google Scholar] [CrossRef]
  4. Wilczek, F. Problem of strong P and T invariance in the presence of instantons. Phys. Rev. Lett. 1978, 40, 279–282. [Google Scholar] [CrossRef]
  5. Preskill, J.; Wise, M.B.; Wilczek, F. Cosmology of the Invisible Axion. Phys. Lett. B 1983, 120, 127–132. [Google Scholar] [CrossRef] [Green Version]
  6. Abbott, L.F.; Sikivie, P. A Cosmological Bound on the Invisible Axion. Phys. Lett. B 1983, 120, 133–136. [Google Scholar] [CrossRef]
  7. Dine, M.; Fischler, W. The Not So Harmless Axion. Phys. Lett. B 1983, 120, 137–141. [Google Scholar] [CrossRef]
  8. Primakoff, H. Photoproduction of neutral mesons in nuclear electric fields and the mean life of the neutral meson. Phys. Rev. 1951, 81, 899. [Google Scholar] [CrossRef]
  9. Sikivie, P. Experimental Tests of the Invisible Axion. Phys. Rev. Lett. 1983, 51, 1415–1417, Erratum in Phys. Rev. Lett. 1984, 52, 695. [Google Scholar] [CrossRef]
  10. Bibber, K.V.; Dagdeviren, N.R.; Koonin, S.E.; Kerman, A.K.; Nelson, H.N. Proposed experiment to produce and detect light pseudoscalars. Phys. Rev. Lett. 1987, 59, 759–762. [Google Scholar] [CrossRef] [Green Version]
  11. Fukuda, Y.; Kohmoto, T.; Nakajima, S.; Kunitomo, M. Production and detection of axions by using optical resonators. Prog. Cryst. Growth Charact. Mater. 1996, 33, 363–366. [Google Scholar] [CrossRef]
  12. Sikivie, P.; Tanner, D.B.; Bibber, K. Resonantly enhanced axion-photon regeneration. Phys. Rev. Lett. 2007, 98, 172002. [Google Scholar] [CrossRef] [Green Version]
  13. Lazarus, D.M.; Smith, G.C.; Cameron, R.; Melissinos, A.C.; Ruoso, G.; Semertzidis, Y.K.; Nezrick, F.A. Search for solar axions. Phys. Rev. Lett. 1992, 69, 2333–2336. [Google Scholar] [CrossRef] [PubMed]
  14. Inoue, Y.; Namba, T.; Moriyama, S.; Minowa, M.; Takasu, Y.; Horiuchi, T.; Yamamoto, A. Search for sub-electronvolt solar axions using coherent conversion of axions into photons in magnetic field and gas helium. Phys. Lett. B 2002, 536, 18–23. [Google Scholar] [CrossRef] [Green Version]
  15. Moriyama, S.; Minowa, M.; Namba, T.; Inoue, Y.; Takasu, Y.; Yamamoto, A. Direct search for solar axions by using strong magnetic field and X-ray detectors. Phys. Lett. B 1998, 434, 147–152. [Google Scholar] [CrossRef] [Green Version]
  16. Inoue, Y.; Akimoto, Y.; Ohta, R.; Mizumoto, T.; Yamamoto, A.; Minowa, M. Search for solar axions with mass around 1 eV using coherent conversion of axions into photons. Phys. Lett. B 2008, 668, 93–97. [Google Scholar] [CrossRef] [Green Version]
  17. Anastassopoulos, V.; Aune, S.; Barth, K.; Belov, A.; Bräuninger, H.; Cantatore, G.; Carmona, J.M.; Castel, J.F.; Cetin, S.A.; Christensen, F.; et al. New CAST limit on the axion–photon interaction. Nat. Phys. 2017, 13, 584–590. [Google Scholar] [CrossRef]
  18. Arik, M.; Aune, S.; Barth, K.; Belov, A.; Borghi, S.; Bräuninger, H.; Cantatore, G.; Carmona, J.M.; Cetin, S.A.; Collar, J.I.; et al. Search for Sub-eV Mass Solar Axions by the CERN Axion Solar Telescope with 3He Buffer Gas. Phys. Rev. Lett. 2011, 107, 261302. [Google Scholar] [CrossRef] [Green Version]
  19. Armengaud, E.; Attie, D.; Basso, S.; Brun, P.; Bykovskiy, N.; Carmona, J.M.; Castel, J.F.; Cebrián, S.; Cicoli, M.; Civitani, M.; et al. Physics potential of the International Axion Observatory (IAXO). J. Cosmol. Astropart. Phys. 2019, 047. [Google Scholar] [CrossRef] [Green Version]
  20. Graham, P.W.; Irastorza, I.G.; Lamoreaux, S.K.; Lindner, A.; Bibber, K.A. Experimental Searches for the Axion and Axion-Like Particles. Annu. Rev. Nucl. Part. Sci. 2015, 65, 485–514. [Google Scholar] [CrossRef] [Green Version]
  21. Irastorza, I.G.; Redondo, J. New experimental approaches in the search for axion-like particles. Prog. Part. Nucl. Phys. 2018, 102, 89–159. [Google Scholar] [CrossRef] [Green Version]
  22. Luzio, L.D.; Giannotti, M.; Nardi, E.; Visinelli, L. The landscape of QCD axion models. Phys. Rep. 2020, 870, 1–117. [Google Scholar] [CrossRef]
  23. Sikivie, P. Invisible axion search methods. Rev. Mod. Phys. 2021, 93, 015004. [Google Scholar] [CrossRef]
  24. Stern, I. ADMX Status. In Proceedings of the Science, 38th International Conference on High Energy Physics, Chicago, IL, USA, 3–10 August 2016. [Google Scholar]
  25. Wuensch, W.; De Panfilis-Wuensch, S.; Semertzidis, Y.K.; Rogers, J.T.; Melissinos, A.C.; Halama, H.J.; Moskowitz, B.E.; Prodell, A.G.; Fowler, W.B.; Nezrick, F.A. Results of a laboratory search for cosmic axions and other weakly coupled light particles. Phys. Rev. D 1989, 40, 3153. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  26. Hagmann, C.; Sikivie, P.; Sullivan, N.S.; Tanner, D.B. Results from a search for cosmic axions. Phys. Rev. D 1990, 42, 1297. [Google Scholar] [CrossRef]
  27. Alesini, D.; Babusci, D.; Di Gioacchino, D.; Gatti, C.; Lamanna, G.; Ligi, C. The KLASH Proposal. arXiv 2017, arXiv:1707.06010. [Google Scholar]
  28. Kenany, S.A.; Anil, M.A.; Backes, K.M.; Brubaker, B.M.; Cahn, S.B.; Carosi, G.; Gurevich, Y.V.; Kindel, W.F.; Lamoreaux, S.K.; Lehnert, K.M.; et al. Design and operational experience of a microwave cavity axion detector for the 20–100 μeV range. Nucl. Instrum. Meth. A 2017, 854, 11–24. [Google Scholar] [CrossRef] [Green Version]
  29. McAllister, B.T.; Flower, G.; Ivanov, E.N.; Goryachev, M.; Bourhill, J.; Tobar, M.E. The ORGAN Experiment: An axion haloscope above 15 GHz. Phys. Dark Universe 2017, 18, 67–72. [Google Scholar] [CrossRef] [Green Version]
  30. Alesini, D.; Braggio, C.; Carugno, G.; Crescini, N.; D’Agostino, D.; Di Gioacchino, D.; Di Vora, R.; Falferi, P.; Gambardella, U.; Gatti, C.; et al. Search for invisible axion dark matter of mass ma = 43 μeV with the QUAX–aγ experiment. Phys. Rev. D 2021, 103, 102004. [Google Scholar] [CrossRef]
  31. Jeong, J.; Youn, S.; Ahn, S.; Kim, J.E.; Semertzidis, Y.K. Concept of multiple-cell cavity for axion dark matter search. Phys. Lett. B 2018, 777, 412–419. [Google Scholar] [CrossRef]
  32. Melcón, A.Á.; Arguedas Cuendis, S.; Cogollos, C.; Díaz-Morcillo, A.; Döbrich, B.; Gallego, J.D.; Gimeno, B.; Irastorza, I.G.; Lozano-Guerrero, A.J.; Malbrunot, C.; et al. Axion searches with microwave filters: The RADES project. J. Cosmol. Astropart. Phys. 2018, 2018, 040. [Google Scholar] [CrossRef] [Green Version]
  33. Kim, Y.; Kim, D.; Jeong, J.; Kim, J.; Shin, Y.C.; Semertzidis, Y.K. Effective approximation of electromagnetism for axion haloscope searches. Phys. Dark Universe 2019, 26, 100362. [Google Scholar] [CrossRef] [Green Version]
  34. Kim, D.; Jeong, J.; Youn, S.; Kim, Y.; Semertzidis, Y.K. Revisiting the detection rate for axion haloscopes. J. Cosmol. Astropart. Phys. 2020, 2020, 100362. [Google Scholar] [CrossRef] [Green Version]
  35. Pozar, D.M. Microwave Enginnering, 2nd ed.; Wiley: Hoboken, NJ, USA, 1998. [Google Scholar]
  36. Zioutas, K.; Aalseth, C.E.; Abriola, D.; Avignone, F.T., III; Brodzinski, R.L.; Collar, J.I.; Creswick, R.; Di Gregorio, D.E.; Farach, H.; Gattone, A.O.; et al. A decommissioned LHC model magnet as an axion telescope. arXiv 1999, arXiv:astro-ph/9801176v2. [Google Scholar] [CrossRef] [Green Version]
  37. Baker, O.K.; Betz, M.; Caspers, F.; Jaeckel, J.; Lindner, A.; Ringwald, A.; Semertzidis, Y.; Sikivie, P.; Zioutas, K. Prospects for searching axion-like particle dark matter with dipole, toroidal and wiggler magnets. arXiv 2011, arXiv:1110.2180v1. [Google Scholar]
  38. Matthaei, G.L.; Young, L.; Jones., E.M.T. Microwave Filters, Impedance-Matching Networks, and Coupling Structures; Artech House: Norwood, MA, USA, 1980. [Google Scholar]
  39. Cameron, R.J.; Kudsia, C.M.; Mansour, R.R. Microwave Filters for Communication Systems: Fundamentals, Design, and Applications, 2nd ed.; Wiley: Hoboken, NJ, USA, 2018. [Google Scholar]
  40. Goryachev, M.; McAllister, B.T.; Tobar, M.E. Axion detection with negatively coupled cavity arrays. Phys. Lett. A 2018, 382, 2199–2204. [Google Scholar] [CrossRef] [Green Version]
  41. Jeong, J.; Youn, S.; Bae, S.; Kim, J.; Seong, T.; Kim, J.E.; Semertzidis, Y.K. Search for Invisible Axion Dark Matter with a Multiple-Cell Haloscope. Phys. Rev. Lett. 2020, 125, 221302. [Google Scholar] [CrossRef]
  42. CST Studio Suite. Electromagnetic Field Simulation Software. Available online: www.3ds.com/products-services/simulia/products/cst-studio-suite/ (accessed on 22 December 2021).
  43. Melcón, A.Á.; Arguedas Cuendis, S.; Cogollos, C.; Díaz-Morcillo, A.; Döbrich, B.; Gallego, J.D.; García Barceló, J.M.; Gimeno, B.; Golm, J.; Irastorza, I.G.; et al. Scalable haloscopes for axion dark matter detection in the 30 μeV range with RADES. J. High Energy Phys. 2020, 84. [Google Scholar]
  44. Radiofrequency and Antenna Solutions. Available online: www.ttinorte.es (accessed on 22 December 2021).
  45. Lake Shore Cryotronics. Available online: www.lakeshore.com (accessed on 22 December 2021).
  46. Micro-Coax, a Carlisle Brand. Available online: www.carlisleit.com/brands/micro-coax/ (accessed on 22 December 2021).
  47. Savitzky, A.; Golay, M.J.E. Smoothing and Differentiation of Data by Simplified Least Squares Procedures. Anal. Chem. 1964, 36, 1627–1639. [Google Scholar] [CrossRef]
  48. Schafer, R.W. On the frequency-domain properties of Savitzky-Golay filters. In Proceedings of the 2011 Digital Signal Processing and Signal Processing Education Meeting (DSP/SPE), Sedona, AZ, USA, 4–7 January 2011. [Google Scholar]
  49. Jimenez, R.; Verde, L.; Peng Oh, S. Dark halo properties from rotation curves. Mon. Not. Roy. Astron. Soc. 2003, 339, 243–259. [Google Scholar] [CrossRef] [Green Version]
  50. Lista, L. Statistical Methods for Data Analysis in Particle Physics; Springer: Berlin/Heidelberg, Germany, 2017. [Google Scholar]
  51. Melcón, A.Á.; Arguedas Cuendis, S.; Baier, J.; Barth, K.; Bräuniger, H.; Calatroni, S.; Cantatore, G.; Caspers, F.; Castel, J.F.; Cetin, S.A.; et al. First results of the CAST-RADES haloscope search for axions at 34.67 μeV. J. High Energy Phys. 2021, 75. [Google Scholar]
  52. Keysight Technologies Application Note 5952-3706E 2019. Available online: www.keysight.com/es/en/assets/7018-06829/application-notes/5952-3706.pdf (accessed on 22 December 2021).
  53. Golm, J.; Arguedas Cuendis, S.; Calatroni, S.; Cogollos, C.; Döbrich, B.; Gallego, J.D.; García Barceló, J.M.; Granados, X.; Gutierrez, J.; Irastorza, I.G.; et al. Thin Film (High Temperature) Superconducting Radiofrequency Cavities for the search of axion dark matter. arXiv 2021, arXiv:2110.01296. [Google Scholar]
  54. The IAXO Collaboration; Abeln, A.; Altenmüller, K.; Arguedas Cuendis, S.; Armengaud, E.; Attié, D.; Aune, S.; Basso, S.; Bergé, L.; Biasuzzi, B.; et al. Conceptual design of BabyIAXO, the intermediate stage towards the International Axion Observatory. J. High Energy Phys. 2021, 137, 1–80. [Google Scholar]
  55. Dafni, T.; Galán, J. Digging into axion physics with (Baby)IAXO (submitted to Universe, Special Issue: Studying the Universe from Spain. In review process). arXiv 2021, arXiv:2112.02286. [Google Scholar]
  56. Arcioni, P.; Bressan, M.; Perregrini, L. A New Boundary Integral Approach to the Determination of Resonant Modes of Arbitrarily Shaped Cavities. IEEE Trans. Microw. Theory Tech. 1995, 43, 1848–1856. [Google Scholar] [CrossRef]
  57. Conciauro, G.; Guglielmi, M.; Sorrentino, R. Advanced Modal Analysis. CAD Techniques for Waveguide Components and Filters; John Wiley and Sons, Ltd.: Hoboken, NJ, USA, 2000. [Google Scholar]
Figure 1. Dipole (left) and solenoid (right) magnets with transversal and axial magnetic fields, respectively.
Figure 1. Dipole (left) and solenoid (right) magnets with transversal and axial magnetic fields, respectively.
Universe 08 00005 g001
Figure 3. Rectangular irises for coupling between neighboring cavities: inductive (left) and capacitive (right). The pictures show the symmetric half of each one.
Figure 3. Rectangular irises for coupling between neighboring cavities: inductive (left) and capacitive (right). The pictures show the symmetric half of each one.
Universe 08 00005 g003
Figure 4. RADES 5-cavity haloscope: scheme and dimensions, and device before copper plating.
Figure 4. RADES 5-cavity haloscope: scheme and dimensions, and device before copper plating.
Universe 08 00005 g004
Figure 5. Electric field pattern (vertical polarization) for the five different configurations of mode T E 101 for the 5-cavity haloscope, with the associated form factors. The red fields denote positive levels, the green fields zero, and the blue fields negative. Taken and modified from [32].
Figure 5. Electric field pattern (vertical polarization) for the five different configurations of mode T E 101 for the 5-cavity haloscope, with the associated form factors. The red fields denote positive levels, the green fields zero, and the blue fields negative. Taken and modified from [32].
Universe 08 00005 g005
Figure 6. Transmission coefficient magnitude at 2 K: simulated (black) and measured (green), where measurements include the effects of cables from and to the VNA. Taken and modified from [32].
Figure 6. Transmission coefficient magnitude at 2 K: simulated (black) and measured (green), where measurements include the effects of cables from and to the VNA. Taken and modified from [32].
Universe 08 00005 g006
Figure 7. Electric field pattern (vertical polarization) for the thirty different configurations of mode T E 101 for the all-inductive 30-cavites haloscope. Numbers on left side refer to the order of the configuration resonances with the frequency. The red regions denote positive E-fields, and the blue regions negative ones.
Figure 7. Electric field pattern (vertical polarization) for the thirty different configurations of mode T E 101 for the all-inductive 30-cavites haloscope. Numbers on left side refer to the order of the configuration resonances with the frequency. The red regions denote positive E-fields, and the blue regions negative ones.
Universe 08 00005 g007
Figure 8. Simulated transmission coefficient magnitude of an all-inductive 30-cavity haloscope at 2 K.
Figure 8. Simulated transmission coefficient magnitude of an all-inductive 30-cavity haloscope at 2 K.
Universe 08 00005 g008
Figure 9. Electric field pattern (vertical polarization) for the thirty different configurations of mode T E 101 along the all-capacitive 30-cavites haloscope. Numbers on the left side refer to the order of the configuration resonances with the frequency. The red regions denote positive E-fields, and the blue regions negative ones.
Figure 9. Electric field pattern (vertical polarization) for the thirty different configurations of mode T E 101 along the all-capacitive 30-cavites haloscope. Numbers on the left side refer to the order of the configuration resonances with the frequency. The red regions denote positive E-fields, and the blue regions negative ones.
Universe 08 00005 g009
Figure 10. Simulated transmission coefficient magnitude of an all-capacitive 30-cavity haloscope at 2 K.
Figure 10. Simulated transmission coefficient magnitude of an all-capacitive 30-cavity haloscope at 2 K.
Universe 08 00005 g010
Figure 11. Manufactured 6cav and 30cav structures with alternated couplings.
Figure 11. Manufactured 6cav and 30cav structures with alternated couplings.
Universe 08 00005 g011
Figure 12. Electric field pattern (vertical polarization) for the thirty different configurations of mode T E 101 for the alternating 30-cavites haloscope. Numbers on the left refer to the order of the configuration resonances with the frequency. The red regions denote positive E-fields, and the blue regions negative ones.
Figure 12. Electric field pattern (vertical polarization) for the thirty different configurations of mode T E 101 for the alternating 30-cavites haloscope. Numbers on the left refer to the order of the configuration resonances with the frequency. The red regions denote positive E-fields, and the blue regions negative ones.
Universe 08 00005 g012
Figure 13. Simulated transmission coefficient magnitude of an alternating 30-cavity haloscope at 2 K.
Figure 13. Simulated transmission coefficient magnitude of an alternating 30-cavity haloscope at 2 K.
Universe 08 00005 g013
Figure 14. Measurement setup. The cavity was placed in the cold bore at near 2 K. The signal was amplified by a cryogenic LNA. Thermal contacts were employed to adapt the cryogenic and room temperatures for both the calibration and signal ports between flanges 1 and 2.
Figure 14. Measurement setup. The cavity was placed in the cold bore at near 2 K. The signal was amplified by a cryogenic LNA. Thermal contacts were employed to adapt the cryogenic and room temperatures for both the calibration and signal ports between flanges 1 and 2.
Universe 08 00005 g014
Figure 15. Block diagram of the analog acquisition module.
Figure 15. Block diagram of the analog acquisition module.
Universe 08 00005 g015
Figure 16. Block diagram of the digital acquisition module.
Figure 16. Block diagram of the digital acquisition module.
Universe 08 00005 g016
Figure 18. Axion–photon coupling vs. axion mass phase-space. In red is the CAST-RADES axion–photon coupling exclusion limit compared to other haloscope results and the CAST solar axion results. Inset: Zoom-in of the parameter range probed in the first CAST-RADES results (34.6738 μeV <ma < 34.6771 μeV), where the green region represents the uncertainty of the measurement. Figure taken from [51].
Figure 18. Axion–photon coupling vs. axion mass phase-space. In red is the CAST-RADES axion–photon coupling exclusion limit compared to other haloscope results and the CAST solar axion results. Inset: Zoom-in of the parameter range probed in the first CAST-RADES results (34.6738 μeV <ma < 34.6771 μeV), where the green region represents the uncertainty of the measurement. Figure taken from [51].
Universe 08 00005 g018
Table 1. Physical dimensions of the 5-cavity haloscope at 2 K and at 298 K.
Table 1. Physical dimensions of the 5-cavity haloscope at 2 K and at 298 K.
Dimensions (mm) T = 2 K T = 298 K
Cavity width (a)22.8622.99
Cavity height (b)10.1610.25
Length external cavities ( L 1 = L 5 )26.6826.82
Length internal cavities ( L 2 = L 3 = L 4 )25.0025.14
Iris width ( W 1 = W 2 = W 3 = W 4 )8.008.14
Iris thickness (t)2.001.95
Table 2. Parameter used to compute the exclusion limit of the axion–photon coupling.
Table 2. Parameter used to compute the exclusion limit of the axion–photon coupling.
ParameterValue
Δ ν 4577 Hz
T sys (7.8 ± 2.0) K
Q l 11,009 ± 483
κ 0.33 ± 0.05
B e (8.8 ± 0.0088) T
ρ a 0.45 GeVcm−3
C0.65
Volume0.03 l
η 0.83
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Díaz-Morcillo, A.; García Barceló, J.M.; Lozano Guerrero, A.J.; Navarro, P.; Gimeno, B.; Arguedas Cuendis, S.; Álvarez Melcón, A.; Cogollos, C.; Calatroni, S.; Döbrich, B.; et al. Design of New Resonant Haloscopes in the Search for the Dark Matter Axion: A Review of the First Steps in the RADES Collaboration. Universe 2022, 8, 5. https://doi.org/10.3390/universe8010005

AMA Style

Díaz-Morcillo A, García Barceló JM, Lozano Guerrero AJ, Navarro P, Gimeno B, Arguedas Cuendis S, Álvarez Melcón A, Cogollos C, Calatroni S, Döbrich B, et al. Design of New Resonant Haloscopes in the Search for the Dark Matter Axion: A Review of the First Steps in the RADES Collaboration. Universe. 2022; 8(1):5. https://doi.org/10.3390/universe8010005

Chicago/Turabian Style

Díaz-Morcillo, Alejandro, José María García Barceló, Antonio José Lozano Guerrero, Pablo Navarro, Benito Gimeno, Sergio Arguedas Cuendis, Alejandro Álvarez Melcón, Cristian Cogollos, Sergio Calatroni, Babette Döbrich, and et al. 2022. "Design of New Resonant Haloscopes in the Search for the Dark Matter Axion: A Review of the First Steps in the RADES Collaboration" Universe 8, no. 1: 5. https://doi.org/10.3390/universe8010005

APA Style

Díaz-Morcillo, A., García Barceló, J. M., Lozano Guerrero, A. J., Navarro, P., Gimeno, B., Arguedas Cuendis, S., Álvarez Melcón, A., Cogollos, C., Calatroni, S., Döbrich, B., Gallego-Puyol, J. D., Golm, J., Irastorza, I. G., Malbrunot, C., Miralda-Escudé, J., Peña Garay, C., Redondo, J., & Wuensch, W. (2022). Design of New Resonant Haloscopes in the Search for the Dark Matter Axion: A Review of the First Steps in the RADES Collaboration. Universe, 8(1), 5. https://doi.org/10.3390/universe8010005

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop