Investigation on the Influence of Solvents on MWCNT-PDMS Nanocomposite Pressure Sensitive Films †

Technische Universität Chemnitz, Reichenhainer Straße 70, 09126 Chemnitz, Germany
*
Author to whom correspondence should be addressed.
Presented at the Eurosensors 2017 Conference, Paris, France, 3–6 September 2017.
Proceedings 2017, 1(4), 384; https://doi.org/10.3390/proceedings1040384
Published: 16 August 2017
(This article belongs to the Proceedings of Proceedings of Eurosensors 2017, Paris, France, 3–6 September 2017)

Abstract

:
Nanocomposites based on Multi-Walled Carbon Nanotubes (MWCNT)—Polydimethylsiloxane (PDMS) polymer achieve pressure sensors sensitive even at very low pressure less than 5 N. For film homogeneity and sensitivity, fabrication procedure and especially the dispersion quality are decisive. Because of high viscosity of PDMS, a solvent is necessary. Solvents exhibit themselves different dispersion quality and in turn different piezoresistive response of the films under pressure. In this paper, the influence of solvents in fabricating the nanocomposite is investigated considering dispersion quality and stability. The best dispersion stability was achieved with isopropanol and the nanocomposite show better results considering sensitivity and hysteresis behavior under pressure.

1. Introduction

In the process of fabricating a polymer nanocomposite based pressure sensor, effective dispersion of MWCNT in the polymer matrix is of great importance as it influences the percolation threshold and therefore the mechanical sensitivity of the sensor and its measurement range. The viscosity of PDMS base polymer is 5.1 Pa-sec [1], exceeding the nominal limit of ultra-sonication for direct dispersion of MWCNTs. A silicone thinner could reduce the viscosity of PDMS but will also reduce the self-life and sensitivity of the nanocomposite senor. Hence, to decrease the viscosity and establish a stable dispersion of MWCNTs in PDMS solvents could be used as solvents can be easily evaporated from the nanocomposite. Dispersion of MWCNTs in solvents is well studied in literature and some strong organic solvents like chloroform, tetrahydrofuran (THF), dimethylformamide (DMF), n-methyl-2-pyrrolidone (NMP) has shown good and stable dispersion quality for MWCNTs [2].
In this paper, in addition to the above-mentioned solvents, isopropanol is also being investigated for its dispersion property, as it is comparatively less hazardous. Solvents could exhibit different dispersion qualities with MWCNTS but miscibility of the solvent to PDMS is more important for the nanocomposite. An immiscible solvent could retain the MWCNTs within the solvent rather than distributing them into the polymer matrix. Solvents like DMF and NMP exhibit lack of compatibility with PDMS as they show vigorous reaction upon mixing with PDMS, forming dense white gel like structure. Hence, DMF and NMP are not considered for this investigation in-spite of their excellent dispersion properties [2]. Isopropanol on the other hand shows miscibility with PDMS up to 36 h and could be considered for short term stable nanocomposites.

2. Materials and Methods

To study the dispersing quality of the solvents, an optimum concentration of 0.1 mg/mL of pristine MWCNT form Sigma Aldrich with relative purity >95%, outer diameter 6–9 nm and length > 1 μm was chosen. Any higher concentration could adversely degrade the dispersion quality and stability. 0.5 mg of MWCNTs was sonicated in 5 g of solvent at 15% amplitude for 30 min using a horn sonicator (Sonoplus HD 7300, horn diameter 3 mm, Bandelin electronic GmbH, Berlin, Germany). The dispersions are then diluted in the corresponding solvents in the ratio 1:50 to obtain the necessary transparency for UV-vis analysis. The dispersions are stored in standard conditions for long-term analysis.
For a cost-effective pressure sensor, less concentration of MWCNTs like 0.8 wt.%, 0.6 wt.% and 0.4 wt.% in PDMS were chosen. A measurable DC resistance approx. 40 MΩ was obtained for a concentration of 0.6 wt.%. Hence, this concentration was mixed with the solvents and dispersed using horn sonicator for 30 min at 15% amplitude. Then the dispersions were stirred in 5 g of PDMS using the magnetic stirrer CAT-M26 for 60 min at 1600 rpm at 70 °C. After cooling, curing agent was mixed gently to the nanocomposites in the ratio 10:1. Later, the nanocomposites were placed in the degassing chamber for 30 min to aid solvent evaporation and eliminate trapped air bubbles. The nanocomposites are then casted PTFE molds of 20 mm diameter and 0.5 mm height and cured in the oven for 10 h at 60 °C.

3. Results and Discussion

3.1. Visual Inspection

At a sonication amplitude of 15% for 30 min a good dispersion of MWCNTs in solvents were obtained. After sonication, no visible agglomerations were seen with homogenously dispersed MWCNTs. The dispersion stability degrades over time across all solvents, with toluene to be the most unstable up to 10 h and isopropanol to most stable over 6 days. Figure 1 shows few agglomerations in isopropanol dispersion after 10 days. Figure 2 shows the degree of dispersion stability in all the solvents after 10 days and it can be observed that, toluene exhibits very poor dispersion stability compared to other solvents. The stability in other solvents cannot be visually determined and hence a UV-vis spectroscopy analysis is required.

3.2. UV Visible Spectroscopy Analysis

UV-vis analysis was performed using Perkin Elmer-Lambda 900 on all the dispersions with wavelength ranging from 350 nm to 1000 nm. Figure 2 shows the characteristic absorbance curves for solvents without MWCNTs (light blue curve) and for dispersions from the day of sonication until 8 days. It can be seen from Figure 2d, as the MWCNT agglomerations increases the absorbance curve moves towards the solvent’s absorbance curve, indications of poor stability. Based on this analysis the degree of dispersion stability over days can be represented as shown in Figure 3 and is in the order: isopropanol > THF > chloroform > toluene.

3.3. Performance Under Pressure

The initial resistance of the fabricated sensors ranges from 12 MΩ to 43 MΩ depending on the solvents, small for good dispersion and large for bad dispersion as few conductive paths are established with the same concentration. All sensors were subjected to a maximum load of 10 N and was applied using a custom-built pressure test bench at a rate of 0.1 N/s. Under pressure, the dispersed MWCNTs in the polymer matrix are brought closer forming more conduction paths as the tunneling gap between MWCNTs are greatly reduced. This behavior can be clearly seen in Figure 4 as a negative relative change in resistance. Figure 4 shows the pressure response for all the sensors and it can be observed that a maximum relative change in resistance of up to 80% at 5 N is obtained for all the samples which is factor of the concentration of MWCNTs. It can also be inferred that, nanocomposites with good dispersion quality exhibits less hysteresis and better sensitivity. Hysteresis and pressure sensing range of the sensors is directly proportional to the quality and stability of the dispersion. Isopropanol and THF exhibit similar hysteresis compared to chloroform and toluene. Toluene on the other hand, due to the poor dispersion quality MWCNTs might be settled down in the sensor film and exhibits a switch response under applied load.

4. Conclusions

In this work the influence of solvents in MWCNT-PDMS based pressure sensors have been investigated. Toluene based sensors exhibited poor dispersion quality and stability, which resulted in poor pressure sensing behavior. Isopropanol and THF bears nearly the same dispersion qualities and good sensitivity to pressure, isopropanol based sensors exhibits less hysteresis compared to that of THF based sensors. Chloroform based sensors are in-between the above two with moderate dispersion stability and good sensitivity to pressure but large hysteresis.

Acknowledgments

The research work is being funded by “Europäischer Sozialfonds” in the form of scholarship for the Ph.D. The Professorship of Electrical Measurements and Sensor Technology, Chemnitz University of Technology under the guidance of Olfa Kanoun, provides the research facility as well as the cost for conference and open access publication.

Conflicts of Interest

The founding sponsor “Europäischer Sozialfonds”, had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results.

References

  1. Hong, J.; Lee, J.; Hong, C.K.; Shim, S.E. Effect of dispersion state of carbon nanotube on the thermal conductivity of polydimethyl siloxane composites. Curr. Appl. Phys. 2010, 10, 359–363. [Google Scholar] [CrossRef]
  2. Liu, C.-X.; Choi, J.-W. Improved Dispersion of Carbon Nanotubes in Polymers at High Concentrations. Nanomaterials 2012, 2, 329–347. [Google Scholar] [CrossRef] [PubMed]
  3. Bauhofer, W.; Kovacs, J.Z. A review and analysis of electrical percolation in carbon nanotube polymer composites. Compos. Sci. Technol. 2009, 69, 1486–1498. [Google Scholar] [CrossRef]
Figure 1. Visual inspection of the dispersion quality: (a) Formation of agglomerations after few days of dispersion; (b) Settling down of MWCNTs in Toluene compared to other solvents.
Figure 1. Visual inspection of the dispersion quality: (a) Formation of agglomerations after few days of dispersion; (b) Settling down of MWCNTs in Toluene compared to other solvents.
Proceedings 01 00384 g001
Figure 2. Absorbance curves obtained with UV-visible spectroscopy up to 8 days from dispersion: (a) Isopropanol; (b) THF; (c) Chloroform; (d) Toluene.
Figure 2. Absorbance curves obtained with UV-visible spectroscopy up to 8 days from dispersion: (a) Isopropanol; (b) THF; (c) Chloroform; (d) Toluene.
Proceedings 01 00384 g002
Figure 3. Stability analysis-absorbance obtained with UV-visible spectroscopy at 350 nm wavelength for all the solvents and dispersions up to 8 days.
Figure 3. Stability analysis-absorbance obtained with UV-visible spectroscopy at 350 nm wavelength for all the solvents and dispersions up to 8 days.
Proceedings 01 00384 g003
Figure 4. Influence of solvent on pressure sensing property of the nanocomposite sensors: (a) Isopropanol; (b) THF; (c) Chloroform; (d) Toluene.
Figure 4. Influence of solvent on pressure sensing property of the nanocomposite sensors: (a) Isopropanol; (b) THF; (c) Chloroform; (d) Toluene.
Proceedings 01 00384 g004

Share and Cite

MDPI and ACS Style

Ramalingame, R.; Chandraker, P.; Kanoun, O. Investigation on the Influence of Solvents on MWCNT-PDMS Nanocomposite Pressure Sensitive Films. Proceedings 2017, 1, 384. https://doi.org/10.3390/proceedings1040384

AMA Style

Ramalingame R, Chandraker P, Kanoun O. Investigation on the Influence of Solvents on MWCNT-PDMS Nanocomposite Pressure Sensitive Films. Proceedings. 2017; 1(4):384. https://doi.org/10.3390/proceedings1040384

Chicago/Turabian Style

Ramalingame, Rajarajan, Pritha Chandraker, and Olfa Kanoun. 2017. "Investigation on the Influence of Solvents on MWCNT-PDMS Nanocomposite Pressure Sensitive Films" Proceedings 1, no. 4: 384. https://doi.org/10.3390/proceedings1040384

APA Style

Ramalingame, R., Chandraker, P., & Kanoun, O. (2017). Investigation on the Influence of Solvents on MWCNT-PDMS Nanocomposite Pressure Sensitive Films. Proceedings, 1(4), 384. https://doi.org/10.3390/proceedings1040384

Article Metrics

Back to TopTop