Next Article in Journal
HIF-1α as a Potential Target for Pharmacologic Correction after Prenatal Hypoxia
Previous Article in Journal
Human Gut Commensal-Derived Exopolysaccharide-Mediated Short-Chain Fatty Acid Production by In Vitro Gastrointestinal Digestion and Its Enzymatic Inhibitory Mechanism Targeting the Microbial Composition of Irritable Bowel Disease (IBD)
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Amperometric Determination of Serotonin Exocytosis in Human Platelets with BDD-on-Quartz MEA Devices †

by
Rosalía González-Brito
1,*,
Pablo Montenegro
1,
Alicia Méndez
1,
Ramtin E. Shabgahi
2,
Alberto Pasquarelli
2 and
Ricardo Borges
1,*
1
Pharmacology Unit, Medical School, Universidad de La Laguna, 38200 La Laguna, Spain
2
Institute of Electron Devices and Circuits, Ulm University, 89069 Ulm, Germany
*
Authors to whom correspondence should be addressed.
Presented at the 3rd International Electronic Conference on Biomolecules, 23–25 April 2024; Available online: https://sciforum.net/event/IECBM2024.
Proceedings 2024, 103(1), 54; https://doi.org/10.3390/proceedings2024103054
Published: 12 April 2024
(This article belongs to the Proceedings of The 3rd International Electronic Conference on Biomolecules)

1. Introduction

Amperometry is arguably the most widely used technique for studying the exocytosis of biological amines, allowing the study of the dynamics and kinetics of this cellular mechanism in real time. In recent decades, multielectrode array (MEA) devices have been developed and increase the efficiency and speed of amperometric measurements. Platelets are the most accessible cells to study the exocytosis of amines as they have 90% of blood serotonin included in their granules, which is avidly uptaken from the blood and released by exocytosis. Furthermore, platelets are not able to synthesize this amine.

2. Methods

We have optimized boron-doped diamond (BDD) MEA systems that allow the detection of amperometric recordings from the quantum release of serotonin from human platelets. With this technique, exocytotic release phenomena are recorded as a succession of discrete signals in the form of spikes that result from electric current intensities measured during the oxidation of the released serotonin. Our initial results were carried out with 16 microelectrode devices on silicon substrate (BDD-on-silicon MEA) [1]. In this conference, we present transparent MEA devices with 16 microelectrodes that allow microscopy observation too.

3. Results

BDD-on-quartz MEA. BDD-on-quartz MEA devices exhibit the same excellent electrochemical properties as BDD-on-silicon MEA: we present a comparative study of quantum and kinetics data obtained with both MEA chips from unloaded platelets and after loading the platelets with 10 µM serotonin for 2 h. And finally, we show examples of the different types of spikes detected.

4. Conclusions

We demonstrate the effectiveness of BDD-on-quartz MEA devices for amperometric studies of serotonin exocytosis from human platelets.

Author Contributions

Conceptualization, R.B. and A.P.; methodology, R.G.-B., P.M. and A.M.; formal analysis, R.G.-B., P.M. and A.M.; software and validation, R.E.S.; review and editing, R.G.-B., R.B. and AP. All authors have read and agreed to the published version of the manuscript.

Funding

This work was partially supported by the Spanish Ministry of Ciencia e Innovación, grant No. PID2020-116589GB-I00, to R.B.

Institutional Review Board Statement

This study was conducted in accordance with the Declaration of Helsinki and was approved by the Ethical Committee at the University of La Laguna (CEIBA2017-0244) and by the Ethical Committee at the Canary Islands Health Services (CHUC_2020_80) for the use of human samples.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The data presented in this study are available in the references.

Conflicts of Interest

The authors declare no conflict of interest.

Reference

  1. González Brito, R.; Montenegro, P.; Méndez, A.; Carabelli, V.; Tomagra, G.; Shabgahi, R.E.; Pasquarelli, A.; Borges, R. Multielectrode Arrays as a Means to Study Exocytosis in Human Platelets. Biosensors 2023, 13, 86. [Google Scholar] [CrossRef] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

González-Brito, R.; Montenegro, P.; Méndez, A.; Shabgahi, R.E.; Pasquarelli, A.; Borges, R. Amperometric Determination of Serotonin Exocytosis in Human Platelets with BDD-on-Quartz MEA Devices. Proceedings 2024, 103, 54. https://doi.org/10.3390/proceedings2024103054

AMA Style

González-Brito R, Montenegro P, Méndez A, Shabgahi RE, Pasquarelli A, Borges R. Amperometric Determination of Serotonin Exocytosis in Human Platelets with BDD-on-Quartz MEA Devices. Proceedings. 2024; 103(1):54. https://doi.org/10.3390/proceedings2024103054

Chicago/Turabian Style

González-Brito, Rosalía, Pablo Montenegro, Alicia Méndez, Ramtin E. Shabgahi, Alberto Pasquarelli, and Ricardo Borges. 2024. "Amperometric Determination of Serotonin Exocytosis in Human Platelets with BDD-on-Quartz MEA Devices" Proceedings 103, no. 1: 54. https://doi.org/10.3390/proceedings2024103054

APA Style

González-Brito, R., Montenegro, P., Méndez, A., Shabgahi, R. E., Pasquarelli, A., & Borges, R. (2024). Amperometric Determination of Serotonin Exocytosis in Human Platelets with BDD-on-Quartz MEA Devices. Proceedings, 103(1), 54. https://doi.org/10.3390/proceedings2024103054

Article Metrics

Back to TopTop