Semiconductor Oxide Gas Sensors: Correlation between Conduction Mechanisms and Their Sensing Performances †

by
Ambra Fioravanti
1,*,
Sara Morandi
2 and
Maria Cristina Carotta
1
1
Institute of Sciences and Technologies for Sustainable Energy and Mobility (CNR–STEMS), Via Canal Bianco 28, 44124 Ferrara, Italy
2
Department of Chemistry, University of Turin, Via P. Giuria 7, 10125 Torino, Italy
*
Author to whom correspondence should be addressed.
Presented at the 1st International Electronic Conference on Chemical Sensors and Analytical Chemistry, 1–15 July 2021; Available online: https://csac2021.sciforum.net/.
Chem. Proc. 2021, 5(1), 71; https://doi.org/10.3390/CSAC2021-10472
Published: 30 June 2021

Abstract

:
In this work, a variety of semiconducting oxides were prepared and principally characterized by means of spectroscopic techniques (absorbance FT-IR, diffuse reflectance UV-Vis-NIR) to shed light on the electronic properties and defects involved at the roots of gas sensing capabilities. The thick films were obtained by screen printing technology on which electrical characterization and gas sensing measurements were performed. From the cross analysis of the results, a description of the specific sensing mechanism for each material is proposed.

1. Introduction

The adsorption of a gas on the surface of a semiconducting oxide can induce a significant change in the electrical resistance of the material. This effect is at the basis of the development of chemiresistors for gas detection [1]. Due to their high sensitivity, tunable selectivity, easy production, small dimensions, and low cost, they are successfully used in a broad range of applications (pollutant monitoring, food quality control, industrial system control, and medical diagnosis) to detect a large number of gaseous compounds. Despite this, an increasing demand of gas sensors with high performances has been documented [2]. Many actions can be made to improve the sensing performances, such as the synthesis of nanostructures with a high specific surface area and the loading with noble metals, but the first issue is to understand the sensing mechanism of the materials and their sensing properties [3,4].
The IR and the UV-Vis spectroscopies are excellent experimental tools for investigating the electronic properties and surface chemistry of a large class of metal oxides used in the fabrication of solid state devices for gas sensing [5].
This work is aimed to determine the electronic properties for a variety of semiconducting oxides (single or combined, such as SnO2 MoO3, WO3, ZnO, TiO2, Ti-Sn, W-Sn, Mn-W mixed oxides, etc.) and to correlate them with the sensing mechanism and the sensor performances.

2. Materials and Methods

A selection of semiconducting oxides (single or combined, such as SnO2 MoO3, WO3, ZnO, TiO2, Ti-Sn, W-Sn, Mn-W mixed oxides, etc.) were prepared using wet chemistry methods [6,7]. The synthesis procedures were optimized to obtain nanopowders with a single phase, and a homogenous distribution in grain size (analyzed by X-ray diffraction and scanning electron microscopy, respectively) was presented.
The powders were characterized by means of spectroscopic techniques with the aim to evaluate the electronic properties and defects involved in the sensing processes. Absorbance IR spectra were run on a Perkin–Elmer System 2000 FT-IR spectrophotometer, equipped with a Hg–Cd–Te cryodetector, working in the range of wavenumbers 7800–580 cm−1. Diffuse reflectance spectra in the UV-Vis-NIR region were run on a Varian Cary 5 spectrophotometer, working in the range of wavenumbers 53,000–4000 cm−1. The spectroscopic responses were studied in the range from room temperature to 500 °C, both for the interaction with pure gases and for mixture gas/O2 at different concentrations depending on the oxide [8,9].
For obtaining thick films for electrical characterization and gas sensing measurements, the functional materials were added to an organic vehicle together with a small percentage of glass frit. Then, they were deposited on alumina substrates with interdigitated Au contacts and a heating element, finally fired at 650 °C. The flow-through technique was used maintaining a flow rate of 0.5 L/min, using synthetic air as carrier gas in dry conditions for the: (i) conductance measurements vs. temperature (room temperature of 650 °C); (ii) surface potential barrier height measurements to determine the intergranular energy barrier (Schottky barrier) versus temperature, following the method of stimulated temperature conductance measurements, as described by Clifford and Tuma [8,10]; and (iii) dynamical responses obtained in the presence of a mixture of different gases and operating temperature from 350 to 550 °C. The sensor response was calculated as the ratio between the conductance in the presence of the gas test and the conductance in air.
Finally, a sensing mechanism was proposed for each material by combining the results of spectroscopic and electrical characterization.

3. Results and Discussion

In this section, the main findings of some single (SnO2, WO3, and TiO2) and mixed (Ti-Sn and W-Sn) oxides, considering the carbon monoxide gas test, are summarized. More detailed characterizations are reported in [8,9].
The spectroscopic measurements on single oxides show that, on the one hand, SnO2 is characterized by the presence of mono-ionized oxygen vacancies (evidence in the medium IR region); on the other hand, WO3 is characterized by the presence of polarons, i.e., electrons trapped in deep levels in the band gap (evidenced in the Vis-NIR region). TiO2 shows both mono-ionized oxygen vacancies and polarons. The amount of defects increases upon CO interaction at increasing temperatures.
As for mixed oxide Sn1-xTixO2, the spectroscopic measurements in CO reveal two different behaviors: (i) samples with x = 0.1 shows absorption related to the photo-ionization of mono-ionized oxygen vacancies, as SnO2 shows; and (ii) samples with 0.3 ≤ x ≤ 0.9 show the increase in an absorption near to the VB–CB edge, as TiO2 shows. Samples with x = 0.2 is a borderline sample, showing behavior in between those of SnO2 and TiO2. This behavior was confirmed by electrical measurements.
Combining the results of spectroscopic and electrical characterization, two detection mechanisms emerge depending on the kind of chemical reaction involved. The first occurs between ionosorbed oxygen atoms and CO, with a consequent electron transfer from surface to bulk, resulting in a conductance increase and a consequent barrier height decrease. The second occurs between surface lattice oxygen atoms and CO; the bond electrons of the surface lattice oxygen atoms do not contribute to the formation of the spatial charge region and the Schottky barrier. To conclude, the prevalent gas detection mechanism in the materials with x < 0.3 is that usually occurs through Schottky barrier modification, whilst x ≥ 0.3 is based on bond electrons which, after the reaction, enter the conduction band without affecting the barrier height, but only bulk conductance.
Concerning the CO responses, the Ti-Sn solid solutions offer higher responses than those of pristine oxides, and the solution with x = 0.25 results in the best material to detect carbon monoxide.
The spectroscopic characterization of W-Sn mixed oxides highlighted the presence of polaron levels, with a position not affected by the Sn content, for mixed oxides with Sn molar content up to 33% (as for WO3) and mono-ionized oxygen vacancies for the mixed oxide with Sn molar content of 89% (as for SnO2).
The different positions of the defect levels in the band gap cause the formation of surface potential barriers significantly lower for WO3 and for mixed oxides with Sn molar content up to 33% (WO3-like samples) than for SnO2 and for the mixed oxide with Sn molar content of 89% (SnO2-like sample). This result allows to define the correlation between the electronic levels associated with the defects and the surface potential barriers in the air and in reducing atmospheres. In particular, the electrical measurements indicate that the changes in the already-low barriers of WO3 and WO3-like samples are almost negligible in the presence of a reducing gas, such as CO; otherwise, CO significantly decreases the barriers of SnO2 and SnO2-like sample. These results are completely in agreement with the low CO sensitivity of WO3 and WO3-like samples, and with the better CO sensitivity of SnO2 and SnO2-like sample.

4. Conclusions

In the electrical characterization, the main parameter typically measured is the conductance. All the operating characteristics of the sensors are derived from this measurement, considering the strength and the weakness of semiconductor sensors. On the one hand, it is simple and easily measured, but it is a second-order parameter that, although very sensitive to some reactions at the solid surface, is not a direct indicator of the exact processes taking place. For this reason, we investigated the behavior of different oxide materials by means of IR and UV-Vis spectroscopies to enlighten surface reactions and electronic properties and coupling the results to those of electrical characterization. We demonstrate the possibility to describe the processes involved in the detection mechanism with a method which can be applied to every functional material characterized towards every gas of interest.

Author Contributions

Conceptualization, characterizations, experiments conduction and data analysis A.F., S.M. and M.C.C.; writing—original draft preparation A.F. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Neri, G. First fifty years of chemoresistive gas sensors. Chemosensors 2015, 3, 1. [Google Scholar] [CrossRef]
  2. Fioravanti, A.; Carotta, M.C. Year 2020: A snapshot of the last progress in flexible printed gas sensors. Appl. Sci. 2020, 10, 1741. [Google Scholar] [CrossRef] [Green Version]
  3. Galstyan, V. “Quantum dots: Perspectives in next-generation chemical gas sensors”—A Review. Anal. Chim. Acta 2021, 152, 238192. [Google Scholar] [CrossRef] [PubMed]
  4. Dey, A. Semiconductor metal oxide gas sensors: A review. Mater. Sci. Eng. B Solid-State Mater. Adv. Technol. 2018, 229, 206–217. [Google Scholar] [CrossRef]
  5. ViterIgor, R.; Barhoum, I. Optical Spectroscopy for Characterization of Metal Oxide Nanofibers; Springer: Cham, Switzerland, 2019; ISBN 9783319536545. [Google Scholar]
  6. Nikam, A.V.; Prasad, B.L.V.; Kulkarni, A.A. Wet chemical synthesis of metal oxide nanoparticles: A review. CrystEngComm 2018, 20, 5091–5107. [Google Scholar] [CrossRef]
  7. Fioravanti, A.; Marani, P.; Massarotti, G.P.; Lettieri, S.; Morandi, S.; Carotta, M.C. (Ti,Sn) solid solution-based gas sensors for new monitoring of hydraulic oil degradation. Materials 2021, 14, 605. [Google Scholar] [CrossRef] [PubMed]
  8. Carotta, M.C.; Fioravanti, A.; Gherardi, S.; Malagù, C.; Sacerdoti, M.; Ghiotti, G.; Morandi, S. (Ti,Sn) solid solutions as functional materials for gas sensing. Sens. Actuators B Chem. 2014, 194, 195–205. [Google Scholar] [CrossRef]
  9. Morandi, S.; Amodio, A.; Fioravanti, A.; Giacomino, A.; Mazzocchi, M.; Sacerdoti, M.; Carotta, M.C.; Skouloudis, A.N. Operational functionalities of air-quality W–Sn metal-oxide sensors correlating semiconductor defect levels and surface potential barriers. Sci. Total Environ. 2020, 706, 135731. [Google Scholar] [CrossRef] [PubMed]
  10. Clifford, P.K.; Tuma, D.T. Characteristics of semiconductor gas sensors II. transient response to temperature change. Sens. Actuators 1982, 3, 255–281. [Google Scholar] [CrossRef]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Fioravanti, A.; Morandi, S.; Carotta, M.C. Semiconductor Oxide Gas Sensors: Correlation between Conduction Mechanisms and Their Sensing Performances. Chem. Proc. 2021, 5, 71. https://doi.org/10.3390/CSAC2021-10472

AMA Style

Fioravanti A, Morandi S, Carotta MC. Semiconductor Oxide Gas Sensors: Correlation between Conduction Mechanisms and Their Sensing Performances. Chemistry Proceedings. 2021; 5(1):71. https://doi.org/10.3390/CSAC2021-10472

Chicago/Turabian Style

Fioravanti, Ambra, Sara Morandi, and Maria Cristina Carotta. 2021. "Semiconductor Oxide Gas Sensors: Correlation between Conduction Mechanisms and Their Sensing Performances" Chemistry Proceedings 5, no. 1: 71. https://doi.org/10.3390/CSAC2021-10472

APA Style

Fioravanti, A., Morandi, S., & Carotta, M. C. (2021). Semiconductor Oxide Gas Sensors: Correlation between Conduction Mechanisms and Their Sensing Performances. Chemistry Proceedings, 5(1), 71. https://doi.org/10.3390/CSAC2021-10472

Article Metrics

Back to TopTop