Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (97)

Search Parameters:
Keywords = QTF

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 3116 KB  
Article
Dual-Component Beat-Frequency Quartz-Enhanced Photoacoustic Spectroscopy Gas Detection System
by Hangyu Xu, Yiwen Feng, Zihao Chen, Zhenzhao Zhuang, Jinbao Xia, Yiyang Zhao and Sasa Zhang
Photonics 2025, 12(8), 747; https://doi.org/10.3390/photonics12080747 - 24 Jul 2025
Viewed by 447
Abstract
This study designed and validated a dual-component beat-frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) gas detection system utilizing time-division multiplexing (TDM). By applying TDM to drive distributed feedback lasers, the system achieved the simultaneous detection of acetylene and methane. Its key innovation lies in exploiting [...] Read more.
This study designed and validated a dual-component beat-frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) gas detection system utilizing time-division multiplexing (TDM). By applying TDM to drive distributed feedback lasers, the system achieved the simultaneous detection of acetylene and methane. Its key innovation lies in exploiting the transient response of the quartz tuning fork (QTF) to acquire gas concentrations while concurrently capturing the QTF resonant frequency and quality factor in real-time. Owing to the short beat period and rapid system response, this approach significantly reduces time-delay constraints in time-division measurements, eliminating the need for periodic calibration inherent in conventional methods and preventing detection interruptions. The experimental results demonstrate minimum detection limits of 5.69 ppm for methane and 0.60 ppm for acetylene. Both gases exhibited excellent linear responses over the concentration range of 200 ppm to 4000 ppm, with the R2 value for methane being 0.996 and for acetylene being 0.997. The system presents a viable solution for the real-time, calibration-free monitoring of dissolved gases in transformer oil. Full article
(This article belongs to the Special Issue Advances in Optical Fiber Sensing Technology)
Show Figures

Figure 1

10 pages, 1296 KB  
Article
High-Sensitivity Dynamic Detection of Dissolved Acetylene in Transformer Oil Based on High-Power Quartz-Enhanced Photoacoustic Spectroscopy Sensing System
by Yuxiang Wu, Tiehua Ma, Chenhua Liu, Yashan Fan, Shuai Shi, Songjie Guo, Yu Wang, Xiangjun Xu, Guqing Guo, Xuanbing Qiu, Zhijin Shang and Chuanliang Li
Photonics 2025, 12(7), 713; https://doi.org/10.3390/photonics12070713 - 16 Jul 2025
Viewed by 390
Abstract
To enable the highly sensitive detection of acetylene (C2H2) dissolved in transformer oil, a high-power quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing system is proposed. A standard 32.7 kHz quartz tuning fork (QTF) was employed as an acoustic transducer, coupled with [...] Read more.
To enable the highly sensitive detection of acetylene (C2H2) dissolved in transformer oil, a high-power quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing system is proposed. A standard 32.7 kHz quartz tuning fork (QTF) was employed as an acoustic transducer, coupled with an optimized acoustic resonator to enhance the acoustic signal. The laser power was boosted to 150 mW using a C-band erbium-doped fiber amplifier (EDFA), achieving a detection limit of 469 ppb for C2H2 with an integration time of 1 s. The headspace degassing method was utilized to extract dissolved gases from the transformer oil, and the equilibrium process for the release of dissolved C2H2 was successfully monitored using the developed high-power QEPAS system. This approach provides reliable technical support for the real-time monitoring of the operational safety of power transformers. Full article
(This article belongs to the Section Lasers, Light Sources and Sensors)
Show Figures

Figure 1

16 pages, 8177 KB  
Article
Study and Characterization of Silicon Nitride Optical Waveguide Coupling with a Quartz Tuning Fork for the Development of Integrated Sensing Platforms
by Luigi Melchiorre, Ajmal Thottoli, Artem S. Vorobev, Giansergio Menduni, Angelo Sampaolo, Giovanni Magno, Liam O’Faolain and Vincenzo Spagnolo
Sensors 2025, 25(12), 3663; https://doi.org/10.3390/s25123663 - 11 Jun 2025
Viewed by 1146
Abstract
This work demonstrates an ultra-compact optical gas-sensing system, consisting of a pigtailed laser diode emitting at 1392.5 nm for water vapor (H2O) detection, a silicon nitride (Si3N4) optical waveguide to guide the laser light, and a custom-designed, [...] Read more.
This work demonstrates an ultra-compact optical gas-sensing system, consisting of a pigtailed laser diode emitting at 1392.5 nm for water vapor (H2O) detection, a silicon nitride (Si3N4) optical waveguide to guide the laser light, and a custom-designed, low-frequency, and T-shaped Quartz Tuning Fork (QTF) as the sensitive element. The system employs both Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) and Light-Induced Thermoelastic Spectroscopy (LITES) techniques for trace gas sensing. A 3.8 mm-wide, S-shaped waveguide path was designed to prevent scattered laser light from directly illuminating the QTF. Both QEPAS and LITES demonstrated comparably low signal-to-noise ratios (SNRs), ranging from 1.6 to 3.2 for a 1.6% indoor H2O concentration, primarily owing to the reduced optical power (~300 μW) delivered to the QTF excitation point. These results demonstrate the feasibility of integrating photonic devices and piezoelectric components into portable gas-sensing systems for challenging environments. Full article
(This article belongs to the Special Issue Feature Papers in Optical Sensors 2025)
Show Figures

Figure 1

68 pages, 5470 KB  
Article
Does Quantum Mechanics Breed Larger, More Intricate Quantum Theories? The Case for Experience-Centric Quantum Theory and the Interactome of Quantum Theories
by Alireza Tavanfar, Sahar Alipour and Ali T. Rezakhani
Universe 2025, 11(5), 162; https://doi.org/10.3390/universe11050162 - 16 May 2025
Viewed by 751
Abstract
We pose and address the radical question of whether quantum mechanics, known for its firm internal structure and enormous empirical success, carries in itself the genomes of larger quantum theories that have higher internal intricacy and phenomenological versatility. In other words, we consider, [...] Read more.
We pose and address the radical question of whether quantum mechanics, known for its firm internal structure and enormous empirical success, carries in itself the genomes of larger quantum theories that have higher internal intricacy and phenomenological versatility. In other words, we consider, at the basic level of closed quantum systems and regardless of interpretational aspects, whether standard quantum theory (SQT) harbors quantum theories with context-based deformed principles or structures, having definite predictive power within much broader scopes. We answer this question in the affirmative following complementary evidence and reasoning arising from quantum-computation-based quantum simulation and fundamental, general, and abstract rationales within the frameworks of information theory, fundamental or functional emergence, and participatory agency. In this light, as we show, one is led to the recently proposed experience-centric quantum theory (ECQT), which is a larger and richer theory of quantum behaviors with drastically generalized quantum dynamics. ECQT allows the quantum information of the closed quantum system’s developed state history to continually contribute to defining and updating the many-body interactions, the Hamiltonians, and even the internal elements and “particles” of the total system. Hence, the unitary evolutions are continually impacted and become guidable by the agent system’s experience. The intrinsic interplay of unitarity and non-Markovianity in ECQT brings about a host of diverse behavioral phases, which concurrently infuse closed and open quantum system characteristics, and it even surpasses the theory of open systems in SQT. From a broader perspective, a focus of our investigation is the existence of the quantum interactome—the interactive landscape of all coexisting, independent, context-based quantum theories that emerge from inferential participatory agencies—and its predictive phenomenological utility. Full article
(This article belongs to the Section Foundations of Quantum Mechanics and Quantum Gravity)
Show Figures

Figure 1

12 pages, 16116 KB  
Article
All-Fiber LITES Sensor Based on Hollow-Core Anti-Resonant Fiber and Self-Designed Low-Frequency Quartz Tuning Fork
by Xiaorong Sun, Weipeng Chen, Ying He, Haiyue Sun, Shunda Qiao and Yufei Ma
Sensors 2025, 25(9), 2933; https://doi.org/10.3390/s25092933 - 6 May 2025
Viewed by 589
Abstract
In this paper, an all-fiber light-induced thermoelastic spectroscopy (LITES) sensor based on hollow-core anti-resonant fiber (HC-ARF) and self-designed low-frequency quartz tuning fork (QTF) is reported for the first time. By utilizing HC-ARF as both the transmission medium and gas chamber, the laser tail [...] Read more.
In this paper, an all-fiber light-induced thermoelastic spectroscopy (LITES) sensor based on hollow-core anti-resonant fiber (HC-ARF) and self-designed low-frequency quartz tuning fork (QTF) is reported for the first time. By utilizing HC-ARF as both the transmission medium and gas chamber, the laser tail fiber was spatially coupled with the HC-ARF, and the end of the HC-ARF was directly guided onto the QTF surface, resulting in an all-fiber structure. This design eliminated the need for lens combinations, thereby enhancing system stability and reducing cost and size. Additionally, a self-designed rectangular-tip QTF with a low resonant frequency of 8.69 kHz was employed to improve the sensor’s detection performance. Acetylene (C2H2), with an absorption line at 6534.37 cm−1 (1.53 μm), was chosen as the target gas. Experimental results clearly demonstrated that the detection performance of the rectangular-tip QTF system was 2.9-fold higher than that of a standard commercial QTF system. Moreover, it exhibited an outstanding linear response to varying C2H2 concentrations, indicating its high sensitivity and reliability in detecting C2H2. The Allan deviation analysis was used to assess the system’s stability, and the results indicated that the system exhibits excellent long-term stability. Full article
Show Figures

Figure 1

14 pages, 5317 KB  
Article
LITES-Based Sensitive CO2 Detection Using 2 μm Diode Laser and Self-Designed 9.5 kHz Quartz Tuning Fork
by Junjie Mu, Jinfeng Hou, Shaoqi Qiu, Shunda Qiao, Ying He and Yufei Ma
Sensors 2025, 25(7), 2099; https://doi.org/10.3390/s25072099 - 27 Mar 2025
Viewed by 562
Abstract
A carbon dioxide (CO2) sensor based on light-induced thermoelastic spectroscopy (LITES) using a 2 μm diode laser and a self-designed low-frequency trapezoidal-head QTF is reported for the first time in this invited paper. The self-designed trapezoidal-head QTF with a low resonant [...] Read more.
A carbon dioxide (CO2) sensor based on light-induced thermoelastic spectroscopy (LITES) using a 2 μm diode laser and a self-designed low-frequency trapezoidal-head QTF is reported for the first time in this invited paper. The self-designed trapezoidal-head QTF with a low resonant frequency of 9464.18 Hz and a high quality factor (Q) of 12,133.56 can significantly increase the accumulation time and signal level of the CO2-LITES sensor. A continuous-wave (CW) distributed-feedback (DFB) diode laser is used as the light source, and the strongest absorption line of CO2 located at 2004.01 nm is chosen. A comparison between the standard commercial QTF with the resonant frequency of 32.768 kHz and the self-designed trapezoidal-head QTF is performed. The experimental results show that the CO2-LITES sensor with the self-designed trapezoidal-head QTF has an excellent linear response to CO2 concentration, and its minimum detection limit (MDL) can reach 46.08 ppm (parts per million). When the average time is increased to 100 s based on the Allan variance analysis, the MDL of the sensor can be improved to 3.59 ppm. Compared with the 16.85 ppm of the CO2-LITES sensor with the commercial QTF, the performance is improved by 4.7 times, demonstrating the superiority of the self-designed trapezoidal-head QTF. Full article
(This article belongs to the Special Issue Sensors in 2025)
Show Figures

Figure 1

11 pages, 1240 KB  
Article
Calibration of a Quartz Tuning Fork as a Sound Detector
by Judith Falkhofen and Marcus Wolff
Appl. Sci. 2025, 15(7), 3655; https://doi.org/10.3390/app15073655 - 26 Mar 2025
Viewed by 426
Abstract
This study compares the performance of a quartz tuning fork (QTF) with a highly sensitive ultrasound microphone in the context of acoustic measurements, applying the substitution calibration method. QTF sensors are increasingly used for high-precision tasks due to their sensitivity and stability, while [...] Read more.
This study compares the performance of a quartz tuning fork (QTF) with a highly sensitive ultrasound microphone in the context of acoustic measurements, applying the substitution calibration method. QTF sensors are increasingly used for high-precision tasks due to their sensitivity and stability, while microphones are still the standard in general acoustic measurements. The aim of this study is to evaluate both technologies across several key performance metrics, including linearity of response, sensitivity, noise characteristics, and acoustic detection limit. Which sensor is better suited to which acoustic and physical condition? The results show that QTFs perform exceptionally well in applications requiring high precision, especially in high-frequency and narrow-band measurements. The signal-to-noise-ratio (SNR) of the QTF at its resonance frequency is 14 dB higher than that of the microphone, whereas the detection limit and linearity are comparable. The findings suggest that QTF sensors are particularly advantageous for specialized applications like photoacoustic spectroscopy (PAS). Full article
(This article belongs to the Special Issue Application of Ultrasonic Non-destructive Testing)
Show Figures

Figure 1

10 pages, 3418 KB  
Article
Off-Beam Acoustic Micro-Resonator for QEPAS Sensor with a Custom Quartz Tuning Fork
by Yong Wang, Gang Wang, Jiapeng Wang, Chaofan Feng, Qingyuan Tian, Yifan Chen, Ruyue Cui, Hongpeng Wu and Lei Dong
Atmosphere 2025, 16(3), 352; https://doi.org/10.3390/atmos16030352 - 20 Mar 2025
Cited by 1 | Viewed by 555
Abstract
Quartz-enhanced photoacoustic spectroscopy (QEPAS) has shown great promise for monitoring greenhouse gases and pollutants with a high measurement accuracy and limit of detection. A QEPAS sensor, which can achieve high photoacoustic signal gain without requiring the laser beam to pass through the two [...] Read more.
Quartz-enhanced photoacoustic spectroscopy (QEPAS) has shown great promise for monitoring greenhouse gases and pollutants with a high measurement accuracy and limit of detection. A QEPAS sensor, which can achieve high photoacoustic signal gain without requiring the laser beam to pass through the two prongs of a quartz tuning fork (QTF), is reported. A custom QTF with a resonant frequency of 7.2 kHz and a quality factor of 8406 was employed as a sound detection element, and the parameters of the acoustic micro-resonator (AmR) in the off-beam QEPAS spectrophone were optimized. A signal-to-noise ratio (SNR) gain of 16 was achieved based on the optimal AmR dimensions compared to the bare custom QTF. Water vapor (H2O) was detected utilizing the QEPAS sensor equipped with the off-beam spectrophone, achieving a minimum detection limit (MDL) of 4 ppm with a normalized noise equivalent absorption coefficient (NNEA) of 5.7 × 10−8 cm−1·W·Hz−1/2 at an integration time of 300 ms. Full article
(This article belongs to the Special Issue New Insights into Photoacoustic Spectroscopy and Its Applications)
Show Figures

Figure 1

25 pages, 1367 KB  
Perspective
Quantum Models of Consciousness from a Quantum Information Science Perspective
by Lea Gassab, Onur Pusuluk, Marco Cattaneo and Özgür E. Müstecaplıoğlu
Entropy 2025, 27(3), 243; https://doi.org/10.3390/e27030243 - 26 Feb 2025
Cited by 1 | Viewed by 7764
Abstract
This perspective explores various quantum models of consciousness from the viewpoint of quantum information science, offering potential ideas and insights. The models under consideration can be categorized into three distinct groups based on the level at which quantum mechanics might operate within the [...] Read more.
This perspective explores various quantum models of consciousness from the viewpoint of quantum information science, offering potential ideas and insights. The models under consideration can be categorized into three distinct groups based on the level at which quantum mechanics might operate within the brain: those suggesting that consciousness arises from electron delocalization within microtubules inside neurons, those proposing it emerges from the electromagnetic field surrounding the entire neural network, and those positing it originates from the interactions between individual neurons governed by neurotransmitter molecules. Our focus is particularly on the Posner model of cognition, for which we provide preliminary calculations on the preservation of entanglement of phosphate molecules within the geometric structure of Posner clusters. These findings provide valuable insights into how quantum information theory can enhance our understanding of brain functions. Full article
(This article belongs to the Special Issue Quantum and Classical Processes in Living Systems)
Show Figures

Figure 1

13 pages, 9604 KB  
Article
A Highly Sensitive Light-Induced Thermoelastic Spectroscopy Sensor Using a Charge Amplifier to Improve the Signal-to-Noise Ratio
by Hanxu Ma, Shunda Qiao, Ying He and Yufei Ma
Sensors 2025, 25(3), 946; https://doi.org/10.3390/s25030946 - 5 Feb 2025
Viewed by 851
Abstract
A highly sensitive light-induced thermoelastic spectroscopy (LITES) sensor employing a charge amplifier (CA) is reported for the first time in this invited paper. CA has the merits of high input impedance and strong anti-interference ability. The usually used transimpedance amplifier (TA) and voltage [...] Read more.
A highly sensitive light-induced thermoelastic spectroscopy (LITES) sensor employing a charge amplifier (CA) is reported for the first time in this invited paper. CA has the merits of high input impedance and strong anti-interference ability. The usually used transimpedance amplifier (TA) and voltage amplifier (VA) were also studied under the same conditions for comparison. A standard commercial quartz tuning fork (QTF) with a resonant frequency of approximately 32.76 kHz was used as the photothermal signal transducer. Methane (CH4) was used as the target gas in these sensors for performance verification. Compared to the TA-LITES sensor and VA-LITES sensor, the reported CA-LITES sensor shows improvements of 1.83 times and 5.28 times in the minimum detection limit (MDL), respectively. When compared to the LITES sensor without an amplifier (WA-LITES), the MDL has a 19.96-fold improvement. After further optimizing the gain of the CA, the MDL of the CA-LITES sensor was calculated as 2.42 ppm, which further improved the performance of the MDL by 30.3 times compared to the WA-LITES. Additionally, long-term stability is analyzed using Allan deviation analysis. When the average time of the sensor system is increased to 50 s, the MDL of the CA-LITES sensor system can be improved to 0.58 ppm. Full article
(This article belongs to the Section Optical Sensors)
Show Figures

Figure 1

12 pages, 10559 KB  
Article
Highly Sensitive T-Shaped Quartz Tuning Fork Based CH4-Light-Induced Thermoelastic Spectroscopy Sensor with Hydrogen and Helium Enhanced Technique
by Yuanzhi Wang, Ying He, Shunda Qiao, Xiaoming Duan and Yufei Ma
Sensors 2024, 24(23), 7743; https://doi.org/10.3390/s24237743 - 4 Dec 2024
Cited by 1 | Viewed by 1926
Abstract
In this paper, a highly sensitive methane (CH4) sensor based on light-induced thermoelastic spectroscopy (LITES) and a T-shaped quartz tuning fork (QTF) with hydrogen (H2) and helium (He) enhancement techniques are reported for the first time. The low resonant [...] Read more.
In this paper, a highly sensitive methane (CH4) sensor based on light-induced thermoelastic spectroscopy (LITES) and a T-shaped quartz tuning fork (QTF) with hydrogen (H2) and helium (He) enhancement techniques are reported for the first time. The low resonant frequency self-designed T-shaped QTF was exploited for improving the energy accumulation time. H2 and He were utilized as surrounding gases for the T-shaped QTF to minimize energy loss, thereby enhancing the sensitivity of the LITES sensor. Additionally, a fiber-coupled multi-pass cell (FC-MPC) with a 40 m optical length was utilized to improve the optical absorption of CH4. The frequency response of the T-shaped QTF with different concentrations of H2 and He was investigated, and the Q factor in the H2 and He environment increased significantly. Compared to operating QTF in a nitrogen (N2) environment, the signal amplitude was enhanced by 2.9 times and 1.9 times in pure H2 and He environments, respectively. This enhancement corresponded to a minimum detection limit (MDL) of 80.3 ppb and 113.6 ppb. Under different CH4 concentrations, the T-shaped QTF-based H2-enhanced CH4-LITES sensor showed an excellent linear response. Furthermore, through Allan deviation analysis, the MDL of the T-shaped QTF-based H2-enhanced CH4-LITES can reach 38 ppb with an 800 s integration time. Full article
(This article belongs to the Special Issue Important Achievements in Optical Measurements in China 2024–2025)
Show Figures

Figure 1

11 pages, 1820 KB  
Article
Estimating Molecular Thermal Averages with the Quantum Equation of Motion and Informationally Complete Measurements
by Daniele Morrone, N. Walter Talarico, Marco Cattaneo and Matteo A. C. Rossi
Entropy 2024, 26(9), 722; https://doi.org/10.3390/e26090722 - 23 Aug 2024
Cited by 4 | Viewed by 1097
Abstract
By leveraging the Variational Quantum Eigensolver (VQE), the “quantum equation of motion” (qEOM) method established itself as a promising tool for quantum chemistry on near-term quantum computers and has been used extensively to estimate molecular excited states. Here, we explore a novel application [...] Read more.
By leveraging the Variational Quantum Eigensolver (VQE), the “quantum equation of motion” (qEOM) method established itself as a promising tool for quantum chemistry on near-term quantum computers and has been used extensively to estimate molecular excited states. Here, we explore a novel application of this method, employing it to compute thermal averages of quantum systems, specifically molecules like ethylene and butadiene. A drawback of qEOM is that it requires measuring the expectation values of a large number of observables on the ground state of the system, and the number of necessary measurements can become a bottleneck of the method. In this work, we focus on measurements through informationally complete positive operator-valued measures (IC-POVMs) to achieve a reduction in the measurement overheads by estimating different observables of interest through the measurement of a single set of POVMs. We show with numerical simulations that the qEOM combined with IC-POVM measurements ensures satisfactory accuracy in the reconstruction of the thermal state with a reasonable number of shots. Full article
(This article belongs to the Special Issue Simulation of Open Quantum Systems)
Show Figures

Figure 1

20 pages, 5239 KB  
Article
A Wave Drift Force Model for Semi-Submersible Types of Floating Wind Turbines in Large Waves and Current
by Nuno Fonseca and Fatemeh H. Dadmarzi
J. Mar. Sci. Eng. 2024, 12(8), 1389; https://doi.org/10.3390/jmse12081389 - 14 Aug 2024
Cited by 3 | Viewed by 1743
Abstract
The correct prediction of slowly varying wave drift loads is important for the mooring analysis of floating wind turbines (FWTs). However, present design analysis tools fail to correctly predict these loads in conditions with current and moderate and large waves. This paper presents [...] Read more.
The correct prediction of slowly varying wave drift loads is important for the mooring analysis of floating wind turbines (FWTs). However, present design analysis tools fail to correctly predict these loads in conditions with current and moderate and large waves. This paper presents a semi-empirical method to correct zero-current potential-flow quadratic transfer functions (QTFs) of horizontal wave drift loads in conditions with current and moderate and large waves. The method is applicable to column-stabilized types of substructures or semi-submersibles. In the first step, the potential-flow QTF is corrected for potential-flow wave–current effects by applying a heuristic method. Second, the generalized Exwave formula corrects for viscous drift effects. Viscous drift effects become important for moderate and large waves. Conditions with current in the same direction as the waves increase the viscous drift contribution further. The method is validated by comparing QTF predictions with empirical QTFs identified from model test data for the INO Windmoor semi. While potential-flow QTFs agree well with the empirical data for small seastates without current, they underestimate the wave drift loads for moderate and large seastates. Conditions with current increase the underestimation. The semi-empirical correction method significantly improves predictions. Full article
(This article belongs to the Special Issue Modelling Techniques for Floating Offshore Wind Turbines)
Show Figures

Figure 1

14 pages, 4353 KB  
Article
Anti-IgG Doped Melanin Nanoparticles Functionalized Quartz Tuning Fork Immunosensors for Immunoglobulin G Detection: In Vitro and In Silico Study
by Dilhan Gürcan, Engin Baysoy and Gizem Kaleli-Can
Sensors 2024, 24(13), 4319; https://doi.org/10.3390/s24134319 - 3 Jul 2024
Cited by 1 | Viewed by 1596
Abstract
The quartz tuning fork (QTF) is a promising instrument for biosensor applications due to its advanced properties such as high sensitivity to physical quantities, cost-effectiveness, frequency stability, and high-quality factor. Nevertheless, the fork’s small size and difficulty in modifying the prongs’ surfaces limit [...] Read more.
The quartz tuning fork (QTF) is a promising instrument for biosensor applications due to its advanced properties such as high sensitivity to physical quantities, cost-effectiveness, frequency stability, and high-quality factor. Nevertheless, the fork’s small size and difficulty in modifying the prongs’ surfaces limit its wide use in experimental research. Our study presents the development of a QTF immunosensor composed of three active layers: biocompatible natural melanin nanoparticles (MNPs), glutaraldehyde (GLU), and anti-IgG layers, for the detection of immunoglobulin G (IgG). Frequency shifts of QTFs after MNP functionalization, GLU activation, and anti-IgG immobilization were measured with an Asensis QTF F-master device. Using QTF immunosensors that had been modified under optimum conditions, the performance of QTF immunosensors for IgG detection was evaluated. Accordingly, a finite element method (FEM)-based model was produced using the COMSOL Multiphysics software program (COMSOL License No. 2102058) to simulate the effect of deposited layers on the QTF resonance frequency. The experimental results, which demonstrated shifts in frequency with each layer during QTF surface functionalization, corroborated the simulation model predictions. A modelling error of 0.05% was observed for the MNP-functionalized QTF biosensor compared to experimental findings. This study validated a simulation model that demonstrates the advantages of a simulation-based approach to optimize QTF biosensors, thereby reducing the need for extensive laboratory work. Full article
(This article belongs to the Special Issue Advances in Electrochemical Sensors for Biomedical Applications)
Show Figures

Figure 1

10 pages, 2115 KB  
Article
Quartz Enhanced Photoacoustic Spectroscopy on Solid Samples
by Judith Falkhofen, Marc-Simon Bahr, Bernd Baumann and Marcus Wolff
Sensors 2024, 24(13), 4085; https://doi.org/10.3390/s24134085 - 24 Jun 2024
Cited by 1 | Viewed by 4522
Abstract
Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) is a technique in which the sound wave is detected by a quartz tuning fork (QTF). It enables particularly high specificity with respect to the excitation frequency and is well known for an extraordinarily sensitive analysis of gaseous samples. [...] Read more.
Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) is a technique in which the sound wave is detected by a quartz tuning fork (QTF). It enables particularly high specificity with respect to the excitation frequency and is well known for an extraordinarily sensitive analysis of gaseous samples. We have developed the first photoacoustic (PA) cell for QEPAS on solid samples. Periodic heating of the sample is excited by modulated light from an interband cascade laser (ICL) in the infrared region. The cell represents a half-open cylinder that exhibits an acoustical resonance frequency equal to that of the QTF and, therefore, additionally amplifies the PA signal. The antinode of the sound pressure of the first longitudinal overtone can be accessed by the sound detector. A 3D finite element (FE) simulation confirms the optimal dimensions of the new cylindrical cell with the given QTF resonance frequency. An experimental verification is performed with an ultrasound micro-electromechanical system (MEMS) microphone. The presented frequency-dependent QEPAS measurement exhibits a low noise signal with a high-quality factor. The QEPAS-based investigation of three different solid synthetics resulted in a linearly dependent signal with respect to the absorption. Full article
(This article belongs to the Special Issue Photoacoustic Sensing, Imaging, and Communications)
Show Figures

Figure 1

Back to TopTop