Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (8)

Search Parameters:
Keywords = adjustable transobturator male system

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 756 KB  
Article
Results of Adjustable Trans-Obturator Male System for Stress Urinary Incontinence after Transurethral Resection or Holmium Laser Enucleation of the Prostate: International Multicenter Study
by Carlos Téllez, Rodrigo Diego, Juliusz Szczesniewski, Alessandro Giammò, Carmen González-Enguita, Sandra Schönburg, Fabian Queissert, Antonio Romero, Andreas Gonsior, Francisco E. Martins, Francisco Cruz, Keith Rourke and Javier C. Angulo
J. Clin. Med. 2024, 13(16), 4628; https://doi.org/10.3390/jcm13164628 - 7 Aug 2024
Cited by 1 | Viewed by 1937
Abstract
Background: Male stress urinary incontinence (SUI) after surgical treatment of benign prostatic enlargement (BPE) is an infrequent but dreadful complication and constitutes a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS®) in these patients is [...] Read more.
Background: Male stress urinary incontinence (SUI) after surgical treatment of benign prostatic enlargement (BPE) is an infrequent but dreadful complication and constitutes a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS®) in these patients is rather unknown, mainly due to the rarity of this condition. We aimed to assess the results of ATOMS to treat SUI after transurethral resection (TURP) or holmium laser enucleation (HoLEP) of the prostate. Methods: Retrospective multicenter study evaluating patients with SUI after TURP or HoLEP for BPE primarily treated with silicone-covered scrotal port (SSP) ATOMS implants in ten different institutions in Europe and Canada between 2018 and 2022. Inclusion criteria were pure SUI for >1 year after endoscopic treatment for BPE and informed consent to receive an ATOMS. The primary endpoint of the study was a dry rate (pad test ≤ 20 mL/day after adjustment). The secondary endpoints were: the total continence rate (no pads and no leakage), complication rate (Clavien–Dindo classification) and self-perceived satisfaction (Patient Global Impression of Improvement (PGI-I) scale 1 to 3). Descriptive analytics, Wilcoxon’s rank sum test and Fisher’s exact test were performed. Results: A total of 40 consecutive patients fulfilled the inclusion criteria, 23 following TURP and 17 HoLEP. After ATOMS adjustment, 32 (80%) patients were dry (78.3% TURP and 82.4% HoLEP; p = 1) and total continence was achieved in 18 (45%) patients (43.5% TURP and 47% HoLEP; p = 0.82). The median pad test was at a 500 (IQR 300) mL baseline (648 (IQR 650) TURP and 500 (IQR 340) HoLEP; p = 0.62) and 20 (IQR 89) mL (40 (IQR 90) RTUP and 10 (IQR 89) HoLEP; p = 0.56) after adjustment. Satisfaction (PGI-I ≤ 3) was reported in 37 (92.5%) patients (95.6% TURP and 88.2% HoLEP; p = 0.5). There were no significant differences between patients treated with TURP or HoLEP regarding the patient age, radiotherapy and number of adjustments needed. After 32.5 (IQR 30.5) months, median follow-up postoperative complications occurred in seven (17.5%) cases (two grade I and five grade II; three after TURP and four HoLEP) and two devices were removed (5%, both HoLEP). Conclusions: ATOMS is an efficacious and safe alternative to treat SUI due to sphincteric damage produced by endoscopic surgery for BPE, both TURP and HoLEP. Future studies with a larger number of patients may identify predictive factors that would allow better patient selection for ATOMS in this scenario. Full article
(This article belongs to the Section Nephrology & Urology)
Show Figures

Figure 1

10 pages, 274 KB  
Article
Factors Influencing Postoperative Overactive Bladder after Adjustable Trans-Obturator Male System Implantation for Male Stress Incontinence following Prostatectomy
by Miguel Virseda-Chamorro, Carlos Téllez, Jesus Salinas-Casado, Juliusz Szczesniewski, Sonia Ruiz-Grana, Ignacio Arance and Javier C. Angulo
J. Clin. Med. 2023, 12(24), 7505; https://doi.org/10.3390/jcm12247505 - 5 Dec 2023
Cited by 1 | Viewed by 1499
Abstract
We aimed to determine the risk factors for postoperative overactive bladder (OAB) in patients treated with an adjustable trans-obturator male system (ATOMS) for stress incontinence after radical treatment of prostate cancer. A prospective study was performed on 56 patients implanted with an ATOMS [...] Read more.
We aimed to determine the risk factors for postoperative overactive bladder (OAB) in patients treated with an adjustable trans-obturator male system (ATOMS) for stress incontinence after radical treatment of prostate cancer. A prospective study was performed on 56 patients implanted with an ATOMS for PPI. Clinical and urodynamic information was recorded before and after ATOMS implantation. We built a multivariate model to find out the clinical and urodynamic factors that independently influenced postoperative OAB and the prognostic factors that influenced the efficacy of medical treatment of OAB. We found that the clinical risk factors were the preoperative intensity of urinary incontinence (number of daily pads used and amount of urinary leakage), International Consultation on Incontinence Questionnaire (ICIQ) score, postoperative number of ATOMS adjustments, final cushion volume, and incontinence cure. The urodynamic data associated with OAB were cystometric bladder capacity, voided volume, volume at initial involuntary contraction (IC), maximum flow rate, bladder contractility index (BCI), and urethral resistance (URA). The prognostic factors for the efficacy of oral treatment of OAB were the volume at the first IC (direct relationship) and the maximum abdominal voiding pressure (inverse relationship). The multivariate model showed that the independent clinical risk factors were the daily pad count before the implantation and the ICIQ score at baseline and after treatment. The independent urodynamic data were the volume at the first IC (inverse relationship) and the URA value (direct relationship). Both predictive factors of treatment efficacy were found to be independent. Detrusor overactivity plays an important role in postoperative OAB, although other urodynamic and clinical factors such as the degree of urethral resistance and abdominal strength may influence this condition. Full article
(This article belongs to the Section Nephrology & Urology)
14 pages, 2341 KB  
Article
Results of Adjustable Trans-Obturator Male System in Patients with Prostate Cancer Treated with Prostatectomy and Radiotherapy: A Multicenter Study
by Javier C. Angulo, Carlos Téllez, Alessandro Giammò, Carmen González-Enguita, Sandra Schoenburg, Fabian Queissert, Juliusz Szczesniewski, Raquel González, Antonio Romero, Andreas Gonsior, Francisco E. Martins, Tiago Antunes-Lopes, Francisco Cruz and Keith Rourke
J. Clin. Med. 2023, 12(14), 4721; https://doi.org/10.3390/jcm12144721 - 17 Jul 2023
Cited by 5 | Viewed by 1867
Abstract
(1) Background: Treatment of male stress incontinence in patients with prostate cancer treated with radical prostatectomy and adjuvant pelvic radiation is a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS) in these patients is not well established, despite [...] Read more.
(1) Background: Treatment of male stress incontinence in patients with prostate cancer treated with radical prostatectomy and adjuvant pelvic radiation is a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS) in these patients is not well established, despite the general belief that outcomes are worse than in patients without radiation. (2) Methods: Retrospective multicenter study evaluating patients treated with silicone-covered scrotal port (SSP) ATOMS implant after radical prostatectomy and radiotherapy in nine different institutions between 2016 and 2022. The primary endpoint was dry patient rate, defined as pad-test ≤ 20 mL/day. The secondary endpoints were complication rate (defined using Clavien–Dindo classification), device removal and self-perceived satisfaction using the Patient Global Impression of Improvement (PGI-I) scale. Wilcoxon rank-sum test, Fisher’s exact test and logistic regression were performed using stepwise method with a 0.15 entry and 0.1 stay criteria. (3) Results: 223 patients fulfilled the criteria for inclusion and 12 (5.4%) received salvage prostatectomy after radiation and 27 (12.1%) previous devices for stress incontinence. After ATOMS adjustment, 95 patients (42.6%) were dry and 36 (16.1%) had complications of any grade (grade I, n = 20; grade II, n = 11; grade III, n = 5) during the first 3 months postoperatively. At a mean of 36 ± 21 months follow-up, the device was explanted in 26 (11.7%) patients. Regarding self-perceived satisfaction with the implant, 105 of 125 patients (84%) considered themselves satisfied (PGI-I 1 to 3). In the univariate analysis, dryness was associated to younger age (p = 0.06), primary prostatectomy (p = 0.08), no previous incontinence surgery (p = 0.02), absence of overactive bladder symptoms (p = 0.04), absence of bladder neck stricture (p = 0.001), no need of surgical revision (p = 0.008) and lower baseline incontinence severity (p = 0.0003). Multivariate analysis identified absence of surgical revision (p = 0.018), absence of bladder neck stricture (p = 0.05), primary prostatectomy (p = 0.07) and lower baseline incontinence severity (p < 0.0001) were independent predictors of dryness. A logistic regression model was proposed and internally validated. (4) Conclusions: ATOMS is an efficacious and safe alternative to treat male incontinence after radical prostatectomy and adjuvant radiotherapy. Factors predictive of dryness are identified in this complex scenario to allow for better patient selection. Full article
(This article belongs to the Special Issue Prostate Cancer Treatment Options and Its Complications)
Show Figures

Figure 1

13 pages, 1788 KB  
Review
Update on Adjustable Trans-Obturator Male System (ATOMS) for Male Incontinence after Prostate Cancer Surgery
by Carlos Téllez, Juliusz Szczesniewski, Miguel Virseda-Chamorro, Ignacio Arance and Javier C. Angulo
Curr. Oncol. 2023, 30(4), 4153-4165; https://doi.org/10.3390/curroncol30040316 - 12 Apr 2023
Cited by 8 | Viewed by 3931
Abstract
(1) Background: The adjustable trans-obturator male system (ATOMS) is a surgical device developed to treat post-prostatectomy incontinence (PPI) after prostate cancer treatment. We review the current literature on this anti-incontinence device with the intention of assessing the effectiveness, safety and duration of the [...] Read more.
(1) Background: The adjustable trans-obturator male system (ATOMS) is a surgical device developed to treat post-prostatectomy incontinence (PPI) after prostate cancer treatment. We review the current literature on this anti-incontinence device with the intention of assessing the effectiveness, safety and duration of the silicone-covered scrotal port (SSP) ATOMS, the only generation of the device that is currently available. (2) Material and Methods: Non-systematic literature review is performed. Forty-eight full-text articles are assessed for eligibility. Case reports, expert opinions or commentaries without specific data reported (n = 6), studies with patients who underwent intervention before 2014 (IP or SP ATOMS; n = 10), and studies with incontinence after transurethral resection of the prostate (TUR-P; n = 2) are excluded for analysis. Thirty studies with SSP ATOMS are included in a qualitative synthesis that incorporates systematic reviews (n = 3), articles partially overlapping with other previously published studies (e.g., follow-up or series updates; n = 9), and studies focusing on specific populations (n = 8). Only articles revealing outcomes of SSP ATOMS were included in the quantitative synthesis of results (n = 10). (3) Results: the pooled data of 1515 patients from the 10 studies with SSP ATOMS confirmed very satisfactory results with this device after adjustment: dry rate: 63–82%, improved rate: 85–100%, complication rate: 7–33%, device infection rate: 2.7–6.2% and explant rate: 0–19%. The durability of the device is reassuring, with 89% of devices in place 5 years after implantation. (4) Conclusion: Despite the absence of randomized controlled studies, the literature findings confirm results of SSP ATOMS appear equivalent to those of artificial urinary sphincters (AUSs) in terms of continence, satisfaction and complications, but with a lower rate of revision in the long-term. A prospective study identified that patients with daily pad test results <900 mL and a Male Stress Incontinence Grading Scale (MSIGS) of not 4 (i.e., early and persistent stream or urine loss) are the best candidates. Future studies centered on the elder population at higher risk of impaired cognitive ability and in patients including radiation as prostate cancer treatment are needed. Full article
(This article belongs to the Special Issue Surgery for Prostate Cancer: Recent Advances and Future Directions)
Show Figures

Figure 1

11 pages, 1670 KB  
Article
ATOMS (Adjustable Trans-Obturator Male System) in Patients with Post-Prostatectomy Incontinence and Previously Treated Urethral Stricture or Bladder Neck Contracture
by Ane Ullate, Ignacio Arance, Miguel Virseda-Chamorro, Sonia Ruiz, Juliusz Szczesniewski, Carlos Téllez, Fabian Queissert, Juan F. Dorado and Javier C. Angulo
J. Clin. Med. 2022, 11(16), 4882; https://doi.org/10.3390/jcm11164882 - 19 Aug 2022
Cited by 9 | Viewed by 2203
Abstract
(1) Background: Male stress incontinence in patients with previously treated urethral or bladder neck stricture is a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS) in these patients is unknown. (2) Methods: All patients with primary ATOMS implants [...] Read more.
(1) Background: Male stress incontinence in patients with previously treated urethral or bladder neck stricture is a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS) in these patients is unknown. (2) Methods: All patients with primary ATOMS implants in our institution between 2014 and 2021 were included. The outcomes of patients with previously treated urethral or bladder neck stricture (≥6 months before ATOMS implant) and stable 16Ch urethral caliber were compared to those without a history of stricture. The primary endpoint was the dry patient rate, defined as the pad test ≤ 20 mL/day, and complication rate, including device removal. The secondary variable was self-perceived satisfaction using the Patient Global Impression of Improvement (PGI-I) scale. Wilcoxon rank sum test, Fisher’s exact test and logistic regression were performed. (3) Results: One hundred and forty-nine consecutive patients were included, twenty-one (14%) previously treated for urethral or bladder neck stricture (seven urethroplasty, nine internal urethrotomy and five bladder neck incision). After ATOMS adjustment, 38% of the patients with treated stricture were continent compared to 83% of those without (p < 0.0001). After weighted matched observations using propensity score pairing, the proportion of continent patients without a previous stricture was 56% (p = 0.236). Complications occurred in 29% of the patients with stricture and in 20% of those without (p = 0.34). The severity of the complications was distributed evenly among the groups (p = 0.42). Regarding self-perceived satisfaction with the implant, 90% of the patients with stricture perceived the results satisfactorily (PGI-I 1–3) compared to 97% of the rest (p = 0.167). Stricture was associated with radiotherapy (p < 0.0001) and time from prostatectomy to implantation (p = 0.012). There was a moderate correlation between previous stricture and the severity of incontinence, both evaluated according to the 24-h pad test (Rho = 0.378; p < 0.0001) and the ICIQ-SF questionnaire (Rho = 0.351; p < 0.0001). Multivariate analysis for the factors predictive of failure after ATOMS adjustment revealed previous stricture (OR 4.66; 95% CI 1.2–18.87), baseline 24-h pad test (per 100 mL, OR 1.28; 95% CI 1.09–1.52) and final cushion volume (per mL, OR 1.34; 95% CI 1.19–1.55). This model predicted dryness with an AUC of 92%. After the PSMATCH procedure using a propensity score, the model remained unchanged, with the previous stricture (OR 8.05; 95% CI 1.08–110.83), baseline 24-h pad test (per 100 mL, OR 1.53; 95% CI 1.15–2.26) and final cushion volume (per mL, OR 1.45; 95% CI 1.17–2) being independent predictors and an AUC of 93%. (4) Conclusions: ATOMS can be used to treat male stress incontinence in patients with a history of stricture, although the effectiveness of the device is reduced. On the other hand, the security and perceived satisfaction were equivalent for both groups. Full article
(This article belongs to the Special Issue New Trends in Urethral Reconstruction)
Show Figures

Figure 1

12 pages, 1439 KB  
Article
Refined Nomogram Incorporating Standing Cough Test Improves Prediction of Adjustable Trans-Obturator Male System (ATOMS) Success to Treat Post-Prostatectomy Male Stress Incontinence
by Juan F. Dorado and Javier C. Angulo
J. Pers. Med. 2022, 12(1), 94; https://doi.org/10.3390/jpm12010094 - 12 Jan 2022
Cited by 6 | Viewed by 2484
Abstract
(1) Background: The adjustable transobturator male system (ATOMS) device serves to treat post-prostatectomy incontinence, as it enhances residual urinary sphincteric function by dorsal compression of the bulbar urethra. We investigated the clinical parameters affecting continence recovery using this device and developed a decision [...] Read more.
(1) Background: The adjustable transobturator male system (ATOMS) device serves to treat post-prostatectomy incontinence, as it enhances residual urinary sphincteric function by dorsal compression of the bulbar urethra. We investigated the clinical parameters affecting continence recovery using this device and developed a decision aid to predict success. (2) Methods: We reviewed consecutive men treated with first-time ATOMS for post-prostatectomy incontinence from 2014 to 2021 at our institution. Patient demographics, reported pads per day (PPD), 24-h pad-test and Standing Cough Test (SCT), results’ grades 1–4, according to Male Stress Incontinence Grading Scale (MSIGS), and the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) questionnaire were assessed. Treatment success was defined as no pads or a single PPD with ≤20-mL 24-h pad-test. Logistic regression was performed using a stepwise model (entry 0.15 and stay criterium 0.1) to evaluate independent variables’ determinant of dryness. Receiver-operating characteristic (ROC) curves for predictive variables were evaluated and their area under curve (AUC) was compared. A nomogram was generated and internally validated to predict probability of treatment success. (3) Results: Overall, 149 men (median age 70 years, IQR 7) were evaluated with a median follow-up of 45 months (IQR 26). Twelve patients (8%) had previous devices for incontinence, and 21 (14.1%) had pelvic radiation. Thirty-five men (23.5%) did not achieve continence after ATOMS adjustment (use of no or one security PPD with ≤20-mL 24-h pad-test). In univariate analysis, Charlson comorbidity index (p = 0.0412), previous urethroplasty (p = 0.0187), baseline PPD (p < 0.0001), 24-h pad-test (p < 0.0001), MSIGS (p < 0.0001), and ICIQ-SF questionnaire score (p < 0.0001) predicted ATOMS failure. In a multivariable model, 24-h pad-test (p = 0.0031), MSIGS (p = 0.0244), and radiotherapy (p = 0.0216) were independent variables, with AUC 0.8221. The association of MSIGS and 24-h pad-test was the superior combination (AUC 0.8236). A nomogram to predict the probability of ATOMS failure using the independent variables identified was proposed. (4) Conclusions: Several variables were identified as predictive of success for ATOMS using clinical history, physical examination (MSIGS), and factors that evaluate urine loss severity (PPD, 24-h pad-test, and ICIQ-SF questionnaire). MSIGS adds prognostic value to 24-h pad-test in assessing success of ATOMS device to treat post-prostatectomy incontinence. A nomogram was proposed to calculate the risk of ATOMS failure, which could be of interest to personalize the decision to use this device or not in the individual patient. Full article
(This article belongs to the Special Issue Advances in Urogenital Pathology)
Show Figures

Figure 1

11 pages, 1126 KB  
Article
ATOMS (Adjustable Transobturator Male System) Is an Effective and Safe Second-Line Treatment Option for Recurrent Urinary Incontinence after Implantation of an AdVance/AdVance XP Fixed Male Sling? A Multicenter Cohort Analysis
by Fabian Queissert, Keith Rourke, Sandra Schönburg, Alessandro Giammò, Andreas Gonsior, Carmen González-Enguita, Antonio Romero, Andres J. Schrader, Francisco Cruz, Francisco E. Martins, Juan F. Dorado and Javier C. Angulo
J. Clin. Med. 2022, 11(1), 81; https://doi.org/10.3390/jcm11010081 - 24 Dec 2021
Cited by 6 | Viewed by 3559
Abstract
(1) Background: This study examined outcomes of second-line ATOMS implantation after failure of the fixed male sling (FMS) AdVance/AdVance XP. (2) Methods: A retrospective multicenter cohort analysis was carried out in men implanted with an ATOMS between 2011 and 2020 after failure of [...] Read more.
(1) Background: This study examined outcomes of second-line ATOMS implantation after failure of the fixed male sling (FMS) AdVance/AdVance XP. (2) Methods: A retrospective multicenter cohort analysis was carried out in men implanted with an ATOMS between 2011 and 2020 after failure of an AdVance/AdVance XP. Success was assessed on the basis of objective (dryness, 0–1 pad/24 h or >20 g/24 h pad test) and subjective results (PGI-I). We performed the Wilcoxon rank sum test, Fisher’s exact test, logistic regression, and multivariate analysis. (3) Results: The study included 88 patients from 9 centers with a mean age of 71.3 years. No Clavien–Dindo > II complications occurred within the first 3 months after ATOMS implantation. A total of 10 cases (9%) required revision in the ensuing clinical course. After a mean follow-up of 42.5 months, 76.1% achieved social continence, and 56.8% used no pads at all. Mean urine leakage/24 h dropped from 422 g (3.9 pads) to 38 g (0.69 pads) and the mean ICIQ-SF decreased from 16.25 to 5.3 (p < 0.0001). PROMs (patient-reported outcome measures) showed improvement in 98.9% of cases, and 63.6% gave a “very much better” PGI-I rating. Multivariate analysis identified a lower probability of achieving maximum satisfaction for the following factors: the AdVance XP as first-line therapy (OR 0.35), a lower ICIQ-SF question 1 (OR 0.26), status post-irradiation (OR 0.14), and more severe pain prior to ATOMS implantation (OR 0.51). (4) Conclusions: Implantation of an ATOMS is an effective and safe second-line treatment option for recurrent urinary incontinence after implantation of an AdVance/AdVance XP sling. High patient satisfaction was demonstrated in a long-term follow-up. Full article
(This article belongs to the Section Nephrology & Urology)
Show Figures

Figure 1

9 pages, 3822 KB  
Article
The Mode of Action of Adjustable Transobturator Male System (ATOMS): Intraoperative Urethral Pressure Measurements
by Sonia Ruiz, Miguel Virseda-Chamorro, Fabian Queissert, Andrés López, Ignacio Arance and Javier C. Angulo
Uro 2021, 1(2), 45-53; https://doi.org/10.3390/uro1020007 - 8 Jun 2021
Cited by 8 | Viewed by 3561
Abstract
(1) Background: The Adjustable Transobturator Male System (ATOMS) device is increasingly used to treat post-prostatectomy incontinence as it enhances residual urinary sphincteric function and allows continence recovery or improvement by dorsal compression of the bulbar urethra through a fixed transobturator mesh passage. The [...] Read more.
(1) Background: The Adjustable Transobturator Male System (ATOMS) device is increasingly used to treat post-prostatectomy incontinence as it enhances residual urinary sphincteric function and allows continence recovery or improvement by dorsal compression of the bulbar urethra through a fixed transobturator mesh passage. The mode of action and the profile of the patients with best results are not totally understood. (2) Methods: Intraoperative urethral pressure measurements at different filling levels of the ATOMS device show increased urethral resistance and enhanced residual sphincteric activity. We evaluated whether the pattern of urethral pressure change secondary to serial progressive intraoperative filling of the cushion can predict postoperative results after ATOMS placement. (3) Results: The regression analysis showed a significant direct relationship between cushion volume and intraurethral pressure (p = 0.000). The median intraurethral pressure at atmospheric pressure was 51 ± 22.7 cm H2O, and at atmospheric pressure plus 4 mL was 80 ± 23.1 cm H2O). Cluster analyses defined a group of patients (n = 6) formed by patients with a distensible urethra and 100% continence after adjustment in contrast to another group (n = 3) with rigid urethras and 33% continence after adjustment. (4) Conclusions: As a part of its continence mechanism, the ATOMS device leads to continence by increasing intraurethral pressure owing to the stretching effect on the urethral wall caused by cushion filling that increases urethral resistance. Full article
Show Figures

Figure 1

Back to TopTop