Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (14)

Search Parameters:
Keywords = color doppler signs

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 1258 KB  
Article
Color Doppler Patterns’ Recognition Indicative of Congenital Heart Defects at the First-Trimester Referral Scan
by Valentina De Robertis, Mariachiara Bosco, Ilaria Fantasia, Claudiana Olivieri, Tiziana Fanelli and Paolo Volpe
Diagnostics 2025, 15(16), 2088; https://doi.org/10.3390/diagnostics15162088 - 20 Aug 2025
Viewed by 308
Abstract
Background/Objectives: First-trimester referral scans in high-risk pregnancies are performed by expert fetal medicine operators using an extended protocol that includes direct fetal heart assessment. This study evaluated inter-operator agreement in characterizing the four-chamber view (4CV) and three vessels and trachea view (3VTV) [...] Read more.
Background/Objectives: First-trimester referral scans in high-risk pregnancies are performed by expert fetal medicine operators using an extended protocol that includes direct fetal heart assessment. This study evaluated inter-operator agreement in characterizing the four-chamber view (4CV) and three vessels and trachea view (3VTV) using color Doppler during such scans in both normal and abnormal cases. Methods: Two independent operators and a fetal cardiologist, all blinded to final diagnoses, retrospectively reviewed 2D images and video clips of the 4CV and 3VTV in 90 fetuses (45 with congenital heart disease [CHD] and 45 controls). The 4CV was classified into four patterns: (1) two atrioventricular (A-V) inflows of similar size, (2) one A-V inflow filling two ventricles, (3) one A-V inflow filling one ventricle, and (4) two A-V inflows with disproportion. The 3VTV was assessed for (1) normal V-sign, (2) abnormal vessel number, (3) abnormal vessel dimension, (4) abnormal spatial relationships, and (5) ductal dependence. Agreement was measured using Cohen’s Kappa. Results: Perfect agreement (K = 1) was seen in normal cases. In CHD cases, inter-operator and operator–cardiologist agreement was almost perfect for 4CV (K = 0.83–0.96) and substantial for 3VTV (K = 0.77–0.80). The lowest agreement occurred with ventricular disproportion in 4CV and abnormalities in vessel number and size in 3VTV. Conclusions: Expert operators show strong agreement in interpreting 4CV and 3VTV patterns in first-trimester scans using color Doppler. However, certain abnormalities—particularly ventricular disproportion and vessel anomalies—remain challenging to consistently interpret. Full article
(This article belongs to the Special Issue Insights into Perinatal Medicine and Fetal Medicine—2nd Edition)
Show Figures

Figure 1

7 pages, 3347 KB  
Case Report
Arterial Embolization with n-Butyl-Cyanoacrylate for a Large Gluteal Intramuscular Hemangioma: A Case Report
by Nicolas Papalexis, Michela Carta, Giuliano Peta, Simone Quarchioni, Maddalena Di Carlo, Marco Miceli and Giancarlo Facchini
Reports 2024, 7(4), 106; https://doi.org/10.3390/reports7040106 - 26 Nov 2024
Viewed by 1125
Abstract
Background and Clinical Significance: We wished to review the use of arterial embolization with n-butyl-cyanoacrylate (NBCA) to treat large high-flow vascular malformations due to its rapid polymerization and ability to permanently occlude large and small vessels. Case Presentation: A 52-year-old male [...] Read more.
Background and Clinical Significance: We wished to review the use of arterial embolization with n-butyl-cyanoacrylate (NBCA) to treat large high-flow vascular malformations due to its rapid polymerization and ability to permanently occlude large and small vessels. Case Presentation: A 52-year-old male presented with a two-year history of progressively worsening pain and swelling in the right gluteal area. Imaging techniques (color Doppler ultrasonography, CT, DSA, and MRI) were utilized for the diagnosis of a large high-flow intramuscular hemangioma. The mass displaced the surrounding tissues but showed no signs of lymphadenopathy or distant metastasis. The treatment involved targeting different arterial feeders over several sessions. Each procedure used NBCA–Lipiodol under fluoroscopic guidance, progressively reducing the malformation’s size and alleviating his symptoms. After the final embolization, the patient showed significant pain relief and a reduction in the size of the malformation, confirmed by follow-up imaging, demonstrating NBCA embolization’s effectiveness. The protocol’s safety and efficacy in this context are discussed. Conclusions: Arterial embolization with NBCA is a promising treatment for large high-flow vascular malformations, providing symptom relief and reductions in lesion size. While this case report highlights the procedure’s efficacy, further research is needed for a broader understanding of its long-term outcomes and potential complications. Full article
(This article belongs to the Section Oncology)
Show Figures

Figure 1

12 pages, 8004 KB  
Case Report
Multimodality Imaging of Primary Hepatic Lymphoma: A Case Report and a Literature Review
by Ryosuke Taiji, Nagaaki Marugami, Aki Marugami, Takahiro Itoh, Sho Shimizu, Ryota Nakano, Yuki Hoda, Hideki Kunichika, Tetsuya Tachiiri, Kiyoyuki Minamiguchi, Satoshi Yamauchi and Toshihiro Tanaka
Diagnostics 2024, 14(3), 306; https://doi.org/10.3390/diagnostics14030306 - 31 Jan 2024
Cited by 5 | Viewed by 2606
Abstract
Primary hepatic lymphoma (PHL) is a rare form of non-Hodgkin lymphoma primarily affecting the liver. We present a case of an 84-year-old man diagnosed with PHL, incidentally detected during abdominal ultrasonography. The ultrasonography showed a hypoechoic nodule. When examined by CEUS, the nodule [...] Read more.
Primary hepatic lymphoma (PHL) is a rare form of non-Hodgkin lymphoma primarily affecting the liver. We present a case of an 84-year-old man diagnosed with PHL, incidentally detected during abdominal ultrasonography. The ultrasonography showed a hypoechoic nodule. When examined by CEUS, the nodule showed hyperenhancement in the arterial phase and hypoenhancement in the portal and late phases. Conversely, CECT demonstrated hypoenhancement through all the phases. The patient declined a tumor biopsy and opted for follow-up care. Ten months later, the lobular mass had increased from 15 mm to 65 mm, presenting as hypoechogenic and demonstrating the “vessel-penetrating sign” on color Doppler imaging. CEUS revealed reticulated enhancement, indicating intratumoral vessels. The mass displayed hypoattenuation on plain CT, hypointensity in T1-weighted images, and hyperintensity in T2-weighted images and exhibited significant restriction in diffusion-weighted images. Both CECT and contrast-enhanced MRI exhibited hypoenhancement. The patient underwent a partial hepatic segmentectomy, and the mass was pathologically diagnosed as a diffuse large B-cell lymphoma. Subsequent postoperative radiological examinations revealed no other lesions, confirming the diagnosis of PHL. Our report highlights specific ultrasonographic signs of PHL observed from an early stage and presents a review of the relevant literature. Full article
(This article belongs to the Special Issue Diagnostic Imaging of Liver Diseases)
Show Figures

Figure 1

16 pages, 5147 KB  
Review
Point-of-Care Ultrasound—History, Current and Evolving Clinical Concepts in Emergency Medicine
by Joseph Osterwalder, Effie Polyzogopoulou and Beatrice Hoffmann
Medicina 2023, 59(12), 2179; https://doi.org/10.3390/medicina59122179 - 15 Dec 2023
Cited by 22 | Viewed by 6883
Abstract
Point-of-care ultrasound (PoCUS) has become an indispensable standard in emergency medicine. Emergency medicine ultrasound (EMUS) is the application of bedside PoCUS by the attending emergency physician to assist in the diagnosis and management of many time-sensitive health emergencies. In many ways, using PoCUS [...] Read more.
Point-of-care ultrasound (PoCUS) has become an indispensable standard in emergency medicine. Emergency medicine ultrasound (EMUS) is the application of bedside PoCUS by the attending emergency physician to assist in the diagnosis and management of many time-sensitive health emergencies. In many ways, using PoCUS is not only the mere application of technology, but also a fusion of already existing examiner skills and technology in the context of a patient encounter. EMUS practice can be defined using distinct anatomy-based applications. The type of applications and their complexity usually depend on local needs and resources, and practice patterns can vary significantly among regions, countries, or even continents. A different approach suggests defining EMUS in categories such as resuscitative, diagnostic, procedural guidance, symptom- or sign-based, and therapeutic. Because EMUS is practiced in a constantly evolving emergency medical setting where no two patient encounters are identical, the concept of EMUS should also be practiced in a fluid, constantly adapting manner driven by the physician treating the patient. Many recent advances in ultrasound technology have received little or no attention from the EMUS community, and several important technical advances and research findings have not been translated into routine clinical practice. The authors believe that four main areas have great potential for the future growth and development of EMUS and are worth integrating: 1. In recent years, many articles have been published on novel ultrasound applications. Only a small percentage has found its way into routine use. We will discuss two important examples: trauma ultrasound that goes beyond e-FAST and EMUS lung ultrasound for suspected pulmonary embolism. 2. The more ultrasound equipment becomes financially affordable; the more ultrasound should be incorporated into the physical examination. This merging and possibly even replacement of aspects of the classical physical exam by technology will likely outperform the isolated use of stethoscope, percussion, and auscultation. 3. The knowledge of pathophysiological processes in acute illness and ultrasound findings should be merged in clinical practice. The translation of this knowledge into practical concepts will allow us to better manage many presentations, such as hypotension or the dyspnea of unclear etiology. 4. Technical innovations such as elastography; CEUS; highly sensitive color Doppler such as M-flow, vector flow, or other novel technology; artificial intelligence; cloud-based POCUS functions; and augmented reality devices such as smart glasses should become standard in emergencies over time. Full article
Show Figures

Figure 1

9 pages, 746 KB  
Article
Ultrasound Evaluation of Tendinopathy in Hemophiliac Patients for the Purpose of Rehabilitation Indications
by Danilo Donati, Paolo Spinnato, Lelia Valdrè, Lydia Piscitelli, Giuseppina Mariagrazia Farella, Enrico Pagliarulo and Maria Grazia Benedetti
J. Clin. Med. 2023, 12(13), 4513; https://doi.org/10.3390/jcm12134513 - 6 Jul 2023
Cited by 1 | Viewed by 2027
Abstract
Background: Hemophilia is a inherited bleeding disorder that is characterized by intra-articular bleeding (hemarthrosis). The aim of the study was to evaluate the state of the satellite tendons of the target joints in the patient with hemophilic arthropathy and propose rehabilitation treatment with [...] Read more.
Background: Hemophilia is a inherited bleeding disorder that is characterized by intra-articular bleeding (hemarthrosis). The aim of the study was to evaluate the state of the satellite tendons of the target joints in the patient with hemophilic arthropathy and propose rehabilitation treatment with eccentric exercises. Methods: The tendons of the joints mainly affected by hemophilic arthropathy were evaluated by ultrasound. The ultrasound evaluation is associated with the use of evaluation clinical scales, such as the Hemophilia Joint Health Score (HJHS), the Functional Independence Score in Hemophilia (FISH), the Hemophilia Activity List (HAL), the DASH, the VISA-A, the VISA-P, and the VAS scale. Results: In 20 patients with hemophilic arthropathy, the thickness of the tendons that were examined was normal. In six subjects with severe joint damage, echostructural alterations were present, and signs of hyperemia and neo-vascularization were detected on color Doppler, as well as the presence of intratendinous calcifications. Conclusions: The tendons of the target joints in patients with hemophilic arthropathy are compromised by the indirect biomechanical damage caused by the joint disease, and rehabilitation treatment with eccentric exercises can be considered safe and effective in improving the tenso-elastic properties of the tendons. Full article
(This article belongs to the Special Issue New Insights in the Diagnosis and Treatment of Hemophilia)
Show Figures

Figure 1

11 pages, 3699 KB  
Technical Note
Extravascular Ultrasound (EVUS) to Assess the Results of Peripheral Endovascular Procedures
by Stefano Fazzini, Federico Francisco Pennetta, Valerio Turriziani, Simona Vona, Andrea Ascoli Marchetti and Arnaldo Ippoliti
Diagnostics 2023, 13(7), 1356; https://doi.org/10.3390/diagnostics13071356 - 6 Apr 2023
Cited by 5 | Viewed by 2359
Abstract
Contrast arteriography (CA) is considered the gold standard to evaluate any phase in peripheral arterial disease (PAD) interventions, from diagnostics to final results. Nevertheless, duplex ultrasonography (DUS) mostly used for the pre/postoperative phase and follow-up control, could be a potential intraoperative adjunctive imaging [...] Read more.
Contrast arteriography (CA) is considered the gold standard to evaluate any phase in peripheral arterial disease (PAD) interventions, from diagnostics to final results. Nevertheless, duplex ultrasonography (DUS) mostly used for the pre/postoperative phase and follow-up control, could be a potential intraoperative adjunctive imaging tool to assess the effects of endovascular revascularization in patients with iliac and femoropopliteal lesions. The PAD “duplex-assisted” protocol includes a preoperative DUS control followed by an intraoperative and a postoperative control. The most important parameters are pulsed doppler spectral analysis and waveform changes, which are impossible to detect with intravascular ultrasound (IVUS). By using a similar acronym, the intraoperative DUS has been previously described as extravascular ultrasound (EVUS). B-mode imaging, color flow, and peak systolic velocity (PSV) are considered. EVUS could be very useful to evaluate the effects of endovascular treatment, mainly in cases of unclear CAs, severe calcifications and/or dissections. In the context of the “leaving nothing behind” strategy, EVUS can drive the physician to evaluate the absence of flow-limiting dissections and decide which target lesion should be treated with antirestenotic therapy, further vessel preparation, or stenting. The EVUS protocol could be a safe and feasible option to improve the completion assessment of endovascular PAD treatment. A better ultrasound waveform is a sign of improved luminal gain and compliance, which is extremely important to finalize the results of new peripheral device technology, such as intravascular lithotripsy. Full article
(This article belongs to the Special Issue Critical Limb Threatening Ischemia in the COVID Era)
Show Figures

Figure 1

21 pages, 6300 KB  
Article
Chick Chorioallantoic Membrane as a Patient-Derived Xenograft Model for Uveal Melanoma: Imaging Modalities for Growth and Vascular Evaluation
by Theodora Tsimpaki, Nikolaos E. Bechrakis, Berthold Seitz, Miriam M. Kraemer, Hongtao Liu, Sami Dalbah, Ekaterina Sokolenko, Utta Berchner-Pfannschmidt and Miltiadis Fiorentzis
Cancers 2023, 15(5), 1436; https://doi.org/10.3390/cancers15051436 - 24 Feb 2023
Cited by 7 | Viewed by 3311
Abstract
Background: Patient-derived tumor xenografts (PDXs) have emerged as valuable preclinical in vivo models in oncology as they largely retain the polygenomic architecture of the human tumors from which they originate. Although animal models are accompanied by cost and time constraints and a low [...] Read more.
Background: Patient-derived tumor xenografts (PDXs) have emerged as valuable preclinical in vivo models in oncology as they largely retain the polygenomic architecture of the human tumors from which they originate. Although animal models are accompanied by cost and time constraints and a low engraftment rate, PDXs have primarily been established in immunodeficient rodent models for the in vivo assessment of tumor characteristics and of novel therapeutic cancer targets. The chick chorioallantoic membrane (CAM) assay represents an attractive alternative in vivo model that has long been used in the research of tumor biology and angiogenesis, and can overcome some of these limitations. Methods: In this study, we reviewed different technical approaches for the establishment and monitoring of a CAM-based uveal melanoma PDX model. Forty-six fresh tumor grafts were acquired after enucleation from six uveal melanoma patients and were implanted onto the CAM on ED7 with Matrigel and a ring (group 1), with Matrigel (group 2), or natively without Matrigel or a ring (group 3). Real-time imaging techniques, such as various ultrasound modalities, optical coherence tomography, infrared imaging, and imaging analyses with Image J for tumor growth and extension, as well as color doppler, optical coherence angiography, and fluorescein angiography for angiogenesis, were performed on ED18 as alternative monitoring instruments. The tumor samples were excised on ED18 for histological assessment. Results: There were no significant differences between the three tested experimental groups regarding the length and width of the grafts during the development period. A statistically significant increase in volume (p = 0.0007) and weight (p = 0.0216) between ED7 and ED18 was only documented for tumor specimens of group 2. A significant correlation of the results for the cross-sectional area, largest basal diameter, and volume was documented between the different imaging and measurement techniques and the excised grafts. The formation of a vascular star around the tumor and of a vascular ring on the base of the tumor was observed for the majority of the viable developing grafts as a sign of successful engraftment. Conclusion: The establishment of a CAM-PDX uveal melanoma model could elucidate the biological growth patterns and the efficacy of new therapeutic options in vivo. The methodological novelty of this study, investigating different implanting techniques and exploiting advances in real-time imaging with multiple modalities, allows precise, quantitative assessment in the field of tumor experimentation, underlying the feasibility of CAM as an in vivo PDX model. Full article
(This article belongs to the Special Issue Latest Development in Melanoma Research)
Show Figures

Figure 1

12 pages, 2080 KB  
Article
Predicting Malignant Lymph Nodes Using a Novel Scoring System Based on Multi-Endobronchial Ultrasound Features
by Momoko Morishita, Keigo Uchimura, Hideaki Furuse, Tatsuya Imabayashi, Takaaki Tsuchida and Yuji Matsumoto
Cancers 2022, 14(21), 5355; https://doi.org/10.3390/cancers14215355 - 30 Oct 2022
Cited by 8 | Viewed by 14418
Abstract
Endobronchial ultrasound (EBUS) features with B-, power/color Doppler, and elastography modes help differentiate between benign and malignant lymph nodes (MLNs) during transbronchial needle aspiration (TBNA); however, only few studies have assessed them simultaneously. We evaluated the diagnostic accuracy of each EBUS feature and [...] Read more.
Endobronchial ultrasound (EBUS) features with B-, power/color Doppler, and elastography modes help differentiate between benign and malignant lymph nodes (MLNs) during transbronchial needle aspiration (TBNA); however, only few studies have assessed them simultaneously. We evaluated the diagnostic accuracy of each EBUS feature and aimed to establish a scoring system to predict MLNs. EBUS features of consecutive patients and final diagnosis per lymph node (LN) were examined retrospectively. In total, 594 LNs from 301 patients were analyzed. Univariable analyses revealed that EBUS features, except for round shape, could differentiate MLNs from benign LNs. Multivariable analysis revealed that short axis (>1 cm), heterogeneous echogenicity, absence of central hilar structure, presence of coagulation necrosis sign, and blue-dominant elastographic images were independent predictors of MLNs. At three or more EBUS features predicting MLNs, our scoring system had high sensitivity (77.9%) and specificity (91.8%). The area under the receiver operating curve (AUC) was 0.894 (95% confidence interval (CI): 0.868–0.920), which was higher than that of B-mode features alone (AUC: 0.840 (95% CI: 0.807–0.873)). The novel scoring system could predict MLNs more accurately than B-mode features alone. Multi-EBUS features may increase EBUS-TBNA efficiency for LN evaluation. Full article
Show Figures

Figure 1

13 pages, 1828 KB  
Article
Hidden Coronary Atherosclerosis Assessment but Not Coronary Flow Reserve Helps to Explain the Slow Coronary Flow Phenomenon in Patients with Angiographically Normal Coronary Arteries
by Carlo Caiati, Fortunato Iacovelli, Giandomenico Mancini and Mario Erminio Lepera
Diagnostics 2022, 12(9), 2173; https://doi.org/10.3390/diagnostics12092173 - 8 Sep 2022
Cited by 9 | Viewed by 2141
Abstract
The significance of the slow coronary flow phenomenon (SCFph), as visualized in patients (pts) with angiographically normal coronary arteries, is controversial. Absolute coronary flow reserve (CFR) in the left anterior descending coronary artery (LAD), non-invasively assessed by a transthoracic color-guided pulsed-wave Doppler (E-Doppler [...] Read more.
The significance of the slow coronary flow phenomenon (SCFph), as visualized in patients (pts) with angiographically normal coronary arteries, is controversial. Absolute coronary flow reserve (CFR) in the left anterior descending coronary artery (LAD), non-invasively assessed by a transthoracic color-guided pulsed-wave Doppler (E-Doppler TTE), is a reliable parameter to assess coronary microcirculatory dysfunction (CMD). Mild and angiographically hidden epicardial atherosclerosis (Hath), as visualized by intracoronary ultrasound (IVUS), which could be the clue to atherosclerotic coronary microvascular involvement, has never been investigated together with CFR in patients. This study was aimed at assessing the value of CFR and HA in explaining the SCFph. Methods. Both non-invasive assessment of CFR in the LAD and corrected TIMI frame count assessment of the coronary contrast runoff were performed in 124 pts with angiographically normal coronary arteries. Among the whole group, 32 patients also underwent intracoronary ultrasounds in the LMCA and LAD, and the maximal plaque burden was assessed (Lesion external elastic (EEM) cross sectional area (CSA)—Lesion Lumen CSA/Lesion EEM CSA * 100). We found that 24 of the 124 pts (group 1) had the SCFph and the remaining 100 had a normal runoff (group 2). CFR, evaluated in both groups, was not significantly different, being 2.79 ± 0.79 (Mean ± SD) in group 1 and 2.90 ± 0.8 in group 2 (p = ns); in the pts also examined by IVUS (32 pts), the SCFph was always associated with hidden atherosclerosis, and a plaque burden of ≥33%. On the contrary, in the normal runoff group, any grade of PB was observed (from no athero to a PB > 70%) and remarkably, 10 pts had no signs of athero or just a minimal plaque burden. This resulted in a ROC curve analysis in which PB < 33% had a high negative predictive value (100%) in ruling out the SCFph. In addition, considering a CFR value < 2.21 as an index of coronary microcirculatory dysfunction, we found CMD in 15 pts (15%) in group 1 and in 7 pts (29%) in group 2 (p = ns). In conclusion, the SCFph is strongly connected to epicardial athero to the extent that the absence of hidden coronary athero has a very high negative predictive power in ruling out SCFph. CFR that is based on an endothelium-independent mechanism remains fairly normal in this condition. An endothelium-dependent microcirculatory constriction at rest due to atherosclerotic involvement of the coronary microvascular network is a possible explanation of the SCFph. Full article
(This article belongs to the Special Issue Coronary Heart Disease Imaging)
Show Figures

Figure 1

19 pages, 12731 KB  
Article
Surgical Management of Chiari Malformation Type I Associated with Syringomyelia: Outcome of Surgeries Based on the New Classification and Study of Cerebrospinal Fluid Dynamics
by Misao Nishikawa, Toru Yamagata, Kentarou Naito, Noritsugu Kunihiro, Hiroaki Sakamoto, Mistuhiro Hara, Kenji Ohata and Takeo Goto
J. Clin. Med. 2022, 11(15), 4556; https://doi.org/10.3390/jcm11154556 - 4 Aug 2022
Cited by 2 | Viewed by 5378
Abstract
Introduction: The mainstay of treatment of syringomyelia associated with Chiari malformation type I (CM-I) is the management of CM-I to normalize the cerebrospinal fluid (CSF) flow at the foramen magnum. CM-I is classified into three independent types. Surgical treatment was selected based on [...] Read more.
Introduction: The mainstay of treatment of syringomyelia associated with Chiari malformation type I (CM-I) is the management of CM-I to normalize the cerebrospinal fluid (CSF) flow at the foramen magnum. CM-I is classified into three independent types. Surgical treatment was selected based on the mechanism of hindbrain ptosis in each CM-I type. Materials and Methods: Foramen magnum decompression (FMD: 213 cases), expansive suboccipital cranioplasty (ESCP: 87 cases), and craniocervical fixation (CCF: 30 cases) were performed. CSF flow dynamics were assessed pre- and post-surgery using cine phase contrast magnetic resonance imaging. During surgery, CSF flow dynamics were examined using color Doppler ultrasonography (CDU). Results: ESCP and FMD demonstrated high rates of improvement in neurological symptoms and signs (82.7%), whereas CCF demonstrated a high rate of improvement in neurological symptoms (89%). The pre-operative maximum flow velocity (cm/s) was significantly lower in patients than in controls and increased post-operatively. During surgery, CDU indicated that the volume of the major cistern was 8 mL, and the maximum flow velocity was >3 mL/s. Conclusions: An appropriate surgical treatment should be selected for CM-I to correct hindbrain ptosis. In addition, it is necessary to confirm the normalization of CSF flow at the foramen of Magendie. Full article
Show Figures

Figure 1

8 pages, 2176 KB  
Article
Ultrasound of the Heel Improves Diagnosis—Tender Entheses in the Heel Region Rarely Corresponds to Inflammatory Enthesitis in Patients with Peripheral Spondyloarthritis
by Sara Kamp Felbo, Mikkel Østergaard, Inge Juul Sørensen and Lene Terslev
J. Clin. Med. 2022, 11(9), 2325; https://doi.org/10.3390/jcm11092325 - 21 Apr 2022
Cited by 4 | Viewed by 2567
Abstract
Enthesitis is a key pathology in spondyloarthritis (SpA), but diagnosis may be clinically challenging. The objective of this study was to investigate the prevalence of ultrasound enthesitis lesions in tender entheses in the heel region in patients with peripheral SpA. In 27 patients [...] Read more.
Enthesitis is a key pathology in spondyloarthritis (SpA), but diagnosis may be clinically challenging. The objective of this study was to investigate the prevalence of ultrasound enthesitis lesions in tender entheses in the heel region in patients with peripheral SpA. In 27 patients with tenderness upon palpation at the Achilles tendon or the plantar fascia insertion, ultrasound assessment of the affected enthesis was performed using greyscale and color Doppler mode. Images were evaluated using the Outcome Measures in Rheumatology (OMERACT) scoring system for enthesitis, scoring presence/absence of hypoechogenicity, thickening, calcifications/enthesophytes, and erosions, and color Doppler activity semi quantitatively from 0 to 3. A total enthesitis sum score was calculated. A second examiner scanned 10 patients for inter-reader reliability. Ultrasound signs of inflammatory enthesitis (thickening/hypoechogenicity and/or Doppler activity) were found in 48%, and 19% showed Doppler activity—all in the Achilles enthesis. Inflammatory pathologies other than enthesitis (e.g., tendinitis, arthritis, bursitis) were identified in 26% of tender heels. The ultrasound OMERACT scoring system for enthesitis lesions showed excellent intra- and inter-reader agreement in a clinical setting. In conclusion, less than 50% of clinically tender entheses are related to inflammatory enthesitis when assessed by ultrasound. Ultrasound is useful for diagnosing other pathologies that may explain tenderness in the area. Full article
(This article belongs to the Special Issue Diagnostic Imaging of Arthritis)
Show Figures

Figure 1

21 pages, 2614 KB  
Review
Ultrasound Technologies and the Diagnosis of Giant Cell Arteritis
by Dragoș Cătălin Jianu, Silviana Nina Jianu, Traian Flavius Dan, Georgiana Munteanu, Claudiu Dumitru Bîrdac, Andrei Gheorghe Marius Motoc, Any Docu Axelerad, Ligia Petrica and Anca Elena Gogu
Biomedicines 2021, 9(12), 1801; https://doi.org/10.3390/biomedicines9121801 - 30 Nov 2021
Cited by 7 | Viewed by 4431
Abstract
Giant cell arteritis (GCA) is a primary autoimmune vasculitis that specifically affects medium-sized extracranial arteries, like superficial temporal arteries (TAs). The most important data to be considered for the ultrasound (US) diagnosis of temporal arteritis are stenosis, acute occlusions and “dark halo” sign, [...] Read more.
Giant cell arteritis (GCA) is a primary autoimmune vasculitis that specifically affects medium-sized extracranial arteries, like superficial temporal arteries (TAs). The most important data to be considered for the ultrasound (US) diagnosis of temporal arteritis are stenosis, acute occlusions and “dark halo” sign, which represent the edema of the vascular wall. The vessel wall thickening of large vessels in GCA can be recognized by the US, which has high sensitivity and is facile to use. Ocular complications of GCA are common and consist especially of anterior arterial ischemic optic neuropathies or central retinal artery occlusion with sudden, painless, and sharp loss of vision in the affected eye. Color Doppler imaging of the orbital vessels (showing low-end diastolic velocities and a high resistance index) is essential to quickly differentiate the mechanism of ocular involvement (arteritic versus non-arteritic), since the characteristics of TAs on US do not correspond with ocular involvement on GCA. GCA should be cured immediately with systemic corticosteroids to avoid further visual loss of the eyes. Full article
(This article belongs to the Section Molecular and Translational Medicine)
Show Figures

Figure 1

12 pages, 1919 KB  
Review
Left Ventricular Deformation and Vortex Analysis in Heart Failure: From Ultrasound Technique to Current Clinical Application
by Simona Sperlongano, Antonello D’Andrea, Donato Mele, Vincenzo Russo, Valeria Pergola, Andreina Carbone, Federica Ilardi, Marco Di Maio, Roberta Bottino, Francesco Giallauria, Eduardo Bossone and Paolo Golino
Diagnostics 2021, 11(5), 892; https://doi.org/10.3390/diagnostics11050892 - 17 May 2021
Cited by 18 | Viewed by 3611
Abstract
Heart failure (HF) is a leading cause of cardiovascular morbidity and mortality. However, its symptoms and signs are not specific or can be absent. In this context, transthoracic echocardiography plays a key role in diagnosing the various forms of HF, guiding therapeutic decision [...] Read more.
Heart failure (HF) is a leading cause of cardiovascular morbidity and mortality. However, its symptoms and signs are not specific or can be absent. In this context, transthoracic echocardiography plays a key role in diagnosing the various forms of HF, guiding therapeutic decision making and monitoring response to therapy. Over the last few decades, new ultrasound modalities have been introduced in the field of echocardiography, aiming at better understanding the morpho-functional abnormalities occurring in cardiovascular diseases. However, they are still struggling to enter daily and routine use. In our review article, we turn the spotlight on some of the newest ultrasound technologies; in particular, analysis of myocardial deformation by speckle tracking echocardiography, and intracardiac flow dynamics by color Doppler flow mapping, highlighting their promising applications to HF diagnosis and management. We also focus on the importance of these imaging modalities in the selection of responses to cardiac resynchronization therapy. Full article
(This article belongs to the Special Issue Trends and Novelties in Cardiovascular Imaging)
Show Figures

Figure 1

10 pages, 453 KB  
Article
Endoscopic Color Doppler Ultrasonographic Evaluation of Gastric Varices Secondary to Left-Sided Portal Hypertension
by Takahiro Sato, Katsu Yamazaki, Mutsuumi Kimura, Jouji Toyota and Yoshiyasu Karino
Diagnostics 2014, 4(3), 94-103; https://doi.org/10.3390/diagnostics4030094 - 26 Jun 2014
Cited by 7 | Viewed by 11672
Abstract
Gastric varices that arise secondary to the splenic vein occlusion can result in gastrointestinal hemorrhaging. Endoscopic color Doppler ultrasonography (ECDUS) was performed in 16 patients with gastric varices secondary to splenic vein occlusion. This study retrospectively evaluated the role of ECDUS in the [...] Read more.
Gastric varices that arise secondary to the splenic vein occlusion can result in gastrointestinal hemorrhaging. Endoscopic color Doppler ultrasonography (ECDUS) was performed in 16 patients with gastric varices secondary to splenic vein occlusion. This study retrospectively evaluated the role of ECDUS in the diagnosis of gastric varices secondary to splenic vein occlusion. Thirteen patients had co-existing pancreatic diseases: 8 with chronic pancreatitis, 4 with cancer of the pancreatic body or tail and 1 with severe acute pancreatitis. Of the remaining 3 patients, 1 had myeloproliferative disease, 1 had advanced gastric cancer, and the third had splenic vein occlusion due to an obscure cause. The endoscopic findings of gastric varices were: variceal form (F) classified as enlarged tortuous (F2) in 12 cases and large, coil-shaped (F3) in 4 cases, and positive for erosion or red color sign of the variceal surface in 4 cases and negative in 12 cases. ECDUS color flow images of gastric variceal flow clearly depicted a round fundal region at the center, with varices expanding to the curvatura ventriculi major of the gastric body in all 16 cases. The velocities of F3 type gastric varices were significantly higher than those of the F2 type. The wall thickness of varices positive for erosion or red color sign was significantly less than the negative cases. I conclude that ECDUS color flow images of gastric variceal flow depicted specific findings of gastric varices secondary to splenic vein occlusion at the round fundal region at the center, with varices expanding to the curvatura ventriculi major of the gastric body. Full article
(This article belongs to the Special Issue Ultrasound Imaging in Medicine)
Show Figures

Figure 1

Back to TopTop