Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (35)

Search Parameters:
Keywords = interim restorations

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 5056 KiB  
Article
Mechanical Behaviors of a New Polymer-Based Restorative Material for Immediate Loading: An In Vitro Comparative Study
by Milena Pisano, Łukasz Zadrożny, Anna Di Marzio, Ignazio Kurti, Silvio Mario Meloni, Aurea Immacolata Lumbau, Francesco Mollica, Mario Cesare Pozzan, Santo Catapano, Rafał Maksymilian Molak, Gabriele Cervino and Marco Tallarico
Appl. Sci. 2024, 14(19), 8751; https://doi.org/10.3390/app14198751 - 27 Sep 2024
Viewed by 1470
Abstract
The aim of the present in vitro comparative study is to validate a novel composite polymer, named “ONLY”, developed to overcome the mechanical drawbacks of conventional, metal-reinforced poly(methyl methacrylate) (PMMA) interim restoration. Ten interim restorations were designed and fabricated (five in the composite [...] Read more.
The aim of the present in vitro comparative study is to validate a novel composite polymer, named “ONLY”, developed to overcome the mechanical drawbacks of conventional, metal-reinforced poly(methyl methacrylate) (PMMA) interim restoration. Ten interim restorations were designed and fabricated (five in the composite “ONLY” group, and five in the metal-reinforced PMMA group). All the samples were screwed into the prototype models, simulating a complete edentulous mandible rehabilitated with six straight implants. Outcome measures were break point (load, N) and displacement (mm) through a static compression test, and material behavior through a dynamic cyclic test method (fatigue test). A total of 20 samples were tested (10 for static and 10 for dynamic). In each group, five samples (test and control) were used. All the specimens completed the mechanical tests, as planned. There was no statistically significant difference between groups for any test. In the test group, the break point was 1953.19 ± 543.73 N, while it was 2031.10 ± 716.68 N in the control group (p = 0.775). The displacement was 1.89 ± 0.34 mm in the test group and 1.98 ± 0.75 mm in the control group (p = 0.763). Using the dynamic cyclic test method, in the control group the mean load was 2504.60 ± 972.15 N, while in the test group the mean load was 3382.00 ± 578.50 N. The difference between groups was 877.40 ± 579.30 N (p value = 0.121). Within the limitations of this in vitro study, the novel composite polymer can be used to immediately load dental implants. Further clinical research is needed to confirm these preliminary results. Full article
(This article belongs to the Special Issue Technical Applications of Oral Health and Clinical Dentistry)
Show Figures

Figure 1

21 pages, 6552 KiB  
Article
A Prediction Method and Model Experiments on Surf-Riding and Broaching in Stern-Quartering Waves
by Jilong Chu, Min Gu, Jiang Lu and Peijie Zhang
J. Mar. Sci. Eng. 2024, 12(9), 1538; https://doi.org/10.3390/jmse12091538 - 4 Sep 2024
Viewed by 3501
Abstract
At present, the International Maritime Organization (IMO) has issued interim guidelines for the direct stability assessment of surf-riding and broaching for the second-generation intact stability criteria. Accurately and efficiently predicting surf-riding and broaching remains a key problem to be solved for the direct [...] Read more.
At present, the International Maritime Organization (IMO) has issued interim guidelines for the direct stability assessment of surf-riding and broaching for the second-generation intact stability criteria. Accurately and efficiently predicting surf-riding and broaching remains a key problem to be solved for the direct stability assessment of surf-riding and broaching. Therefore, a six-degree-of-freedom(6DOF) coupled mathematical model is established in this paper. Firstly, the four-degree-of-freedom(4DOF) coupled equations of surge–sway–roll–yaw motions are built based on the traditional MMG maneuvering mathematical model by considering Froude–Krylov forces, diffraction forces and restoring forces, and the heave and pitch are approximately calculated by iteratively solving improved static equilibrium equations in real-time, effectively solving the divergence problem in direct time-domain seakeeping calculations of high-speed ships in stern-quartering waves. Secondly, the hydrodynamic lift forces due to the coexistence of wave particle velocity and ship forward velocity are taken into account in the propeller-thrust and rudder-force models. In addition, the real-time emersion of twin rudders in waves is considered in the rudder-force models. At the same time, the free-running model experiments with a ONR tumblehome vessel are carried out in stern-quartering waves, and the pure loss of stability and broaching motions are observed. Finally, comparative validations between the calculations and the experiments of surf-riding and broaching in stern-quartering waves are carried out, and the effects of the ship speed, the instantaneous wetted surface of the hull, rudder exposure, heave and pitch motions on predicting surf-riding and broaching motions are investigated. The computation results show that the established 6DOF mathematical model has enough accuracy to be used for the direct stability assessment of the surf-riding and broaching failure modes. Full article
(This article belongs to the Section Ocean Engineering)
Show Figures

Figure 1

9 pages, 13751 KiB  
Case Report
Fully Digitalized Workflow of Flipper Fabrication: Different Three-Dimensional Printing Strategies and Characteristics
by Shilpa Rana and Du-Hyeong Lee
Appl. Sci. 2024, 14(7), 2838; https://doi.org/10.3390/app14072838 - 28 Mar 2024
Cited by 1 | Viewed by 1459
Abstract
A flipper is an interim removable partial denture used for immediate esthetic restoration and space maintenance for a limited period before definitive treatment. Traditional methods for fabricating flippers are labor-intensive and manual. With the advent of technological advancement in dentistry, fully digitalized fabrication [...] Read more.
A flipper is an interim removable partial denture used for immediate esthetic restoration and space maintenance for a limited period before definitive treatment. Traditional methods for fabricating flippers are labor-intensive and manual. With the advent of technological advancement in dentistry, fully digitalized fabrication including computer designing and three-dimensional (3D) printing can be used. This study aimed to demonstrate the complete digital workflow for fabricating flippers and compare the features of different digital methods. In a partially edentulous patient, three flippers were fabricated using different digital protocols: individual printing (tooth and base parts) and combination, i.e., one-body printing and gingival layering and one-body printing and gingival coloring. Each flipper was tried into the oral cavity, and the adaptation of flippers was evaluated using the triple-scan technique. This study confirms that fully digital fabrication of a flipper is an effective method compared with traditional methods and shows various digital workflows available in 3D printing. Thus, an appropriate fabrication method must be selected for each situation. Full article
(This article belongs to the Section Additive Manufacturing Technologies)
Show Figures

Figure 1

14 pages, 7858 KiB  
Article
Comparative Analysis of the Fracture Resistance of a Polymeric Material for 3D Printing and a Milled Polymethylmethacrylate Material as Interim Material for Fixed Partial Dentures: New Material Updated
by Cristian Abad-Coronel, Johanna Córdova, Andrea Merchán, Jaime Larriva, Ariana Bravo, Bryam Bernal, Cesar A. Paltán and Jorge I. Fajardo
Designs 2023, 7(5), 118; https://doi.org/10.3390/designs7050118 - 13 Oct 2023
Cited by 1 | Viewed by 3164
Abstract
The aim of this study was to evaluate and compare the fracture resistance of a temporary three-unit fixed dental prosthesis (FDP) made of a new polymeric material obtained by an additive technique (3DPP) using a computer-aided design and manufacturing (CAD/CAM) system, comparing the [...] Read more.
The aim of this study was to evaluate and compare the fracture resistance of a temporary three-unit fixed dental prosthesis (FDP) made of a new polymeric material obtained by an additive technique (3DPP) using a computer-aided design and manufacturing (CAD/CAM) system, comparing the prosthesis to the respective outcomes of temporary polymethylmethacrylate (PMMA) FDPs obtained by a subtractive technique (milling). Methods: Three-unit FDPs were 3D printed using a polymeric material (n = 20) or milled using polymethylmethacrylate (n = 20). After thermocycling at 5000 cycles at extreme temperatures of 5 °C and 55 °C in distilled water, each specimen was subjected to a compression test on a universal testing machine at a rate of 0.5 mm/min until failure occurred, recording the value in newtons (N). Results: There were statistically significant differences (p-value < 0.005) between the PMMA material (2104.7 N; SD = 178.97 N) and 3DPP (1000.8 N; SD = 196.4 N). Conclusions: The fracture resistance of the PDFs manufactured from milled PMMA showed higher values for fracture resistance. However, the resistance of the 3DPP showed acceptable values under mechanical load; this notable advance in the resistance of printed materials consolidates them as an important alternative to use in interim indirect restorations. Full article
Show Figures

Figure 1

12 pages, 3733 KiB  
Article
Fracture Resistance Comparative Analysis of Milled-Derived vs. 3D-Printed CAD/CAM Materials for Single-Unit Restorations
by Cristian Abad-Coronel, Manuel Bravo, Salomé Tello, Emilia Cornejo, Yirelly Paredes, Cesar A. Paltan and Jorge I. Fajardo
Polymers 2023, 15(18), 3773; https://doi.org/10.3390/polym15183773 - 15 Sep 2023
Cited by 7 | Viewed by 2623
Abstract
The aim of this study was to evaluate and compare the fracture resistance of a single-unit fixed prosthesis, using a CAD/CAM PMMA material and two printed materials (3DPPa and 3DPPb). A typodont with a specific preparation for a full crown was used; a [...] Read more.
The aim of this study was to evaluate and compare the fracture resistance of a single-unit fixed prosthesis, using a CAD/CAM PMMA material and two printed materials (3DPPa and 3DPPb). A typodont with a specific preparation for a full crown was used; a digital impression was made with a state-of-the-art scanner (PrimeScanTM, Dentsply-SironaTM, New York, NY, USA), and a full coverage restoration was designed using a biogeneric design proposal by means of specific software (InLAB 22.1, Dentsply-Sirona, NY, USA). Sixty crowns were prepared, divided into three groups according to the material: 3DPPa (n = 20), 3DPPb (n = 20), both 3D-printed from the .STL file with a resolution of 50 μm, and PMMA (n = 20) milled-derived, which were subjected to a thermocycling process. A universal testing machine (Universal/Tensile Testing Machine, Autograph AGS-X Series) with integrated software (TRAPEZIUM LITE X) equipped with a 20 kN load cell was used to determine the fracture resistance. Significant differences were found by Kruskal–Wallis test and multiple comparisons (p < 0.05) in fracture resistance between materials. The fracture resistance for the PMMA material was higher, and the standard deviation was lower (x = 1427.9; sd = 36.9 N) compared to the 3DPPa (x = 1231; sd = 380.1 N) and 3DPPb (x = 1029.9; sd = 166.46 N) prints. The restorations from the milled-derived group showed higher average fracture resistance than the provisional restorations obtained from the printed groups. However, the results demonstrated that all three materials analyzed in single-unit restorations are capable of withstanding the average masticatory forces. Full article
(This article belongs to the Special Issue Polymers for Medical and Dental Applications)
Show Figures

Figure 1

12 pages, 2355 KiB  
Article
Patient Satisfaction with Anterior Interim CAD-CAM Rehabilitations Designed by CAD Technician versus Trained Dentist—A Clinical Preliminary Study
by Laura Althea Cuschieri, Amy Casha, Juliana No-Cortes, Jacqueline Ferreira Lima and Arthur Rodriguez Gonzalez Cortes
Appl. Sci. 2023, 13(14), 8243; https://doi.org/10.3390/app13148243 - 16 Jul 2023
Cited by 4 | Viewed by 2297
Abstract
The objective of this study was to assess the impact of digital waxing expertise on patient satisfaction with anterior interim computer-aided design and computer-aided manufacturing (CAD-CAM) prosthetic rehabilitations designed either by a CAD and dental technician or by a dental clinician with basic [...] Read more.
The objective of this study was to assess the impact of digital waxing expertise on patient satisfaction with anterior interim computer-aided design and computer-aided manufacturing (CAD-CAM) prosthetic rehabilitations designed either by a CAD and dental technician or by a dental clinician with basic CAD-CAM training. This in vivo preliminary study was conducted on a total of 18 patients receiving anterior CAD-CAM rehabilitations (at least from canine to canine) with fixed bridges and/or single crowns. Only patients that had conventional chairside temporary restorations were enrolled. Three within-patient groups were defined at different time points: group CONTROL refers to all 18 patients at their first appointment, when they were using their initial temporary conventional prostheses; group DENT refers to all patients immediately after trying in a set of CAD-CAM prostheses designed by a dental clinician (with basic one-week CAD-CAM training); and group CAD refers to all patients after trying in a set of CAD-CAM prostheses for the same tooth elements but designed by an experienced CAD technician (who was also an experienced dental prosthetic technician). All CAD-CAM restorations were milled in polymethyl methacrylate (PMMA) with high translucency and strength properties (Prime, Zirkonzahn). Satisfaction with comfort and esthetics was assessed for all patients for the three different time points (groups CONTROL, DENT and CAD). Statistically significant differences among groups were assessed with the Friedmann’s test. Group CAD significantly outperformed the other groups in both assessed variables (p = 0.001). The group DENT, in turn, outperformed group CONTROL for satisfaction with esthetics (p = 0.006) but not for comfort (p > 0.05). In conclusion, CAD operator background and expertise level significantly affect patient self-reported outcomes for anterior CAD-CAM rehabilitations. Single crowns and fixed bridges digitally designed by an experienced professional trained in both CAD-CAM and dental technology will likely offer high satisfaction and comfort to patients receiving anterior prosthetic rehabilitations. Full article
Show Figures

Figure 1

12 pages, 2902 KiB  
Article
Trueness, Flexural Strength, and Surface Properties of Various Three-Dimensional (3D) Printed Interim Restorative Materials after Accelerated Aging
by Omar Alageel, Saleh Alhijji, Omar Alsadon, Majed Alsarani, Abdurabu Abdullah Gomawi and Abdulaziz Alhotan
Polymers 2023, 15(14), 3040; https://doi.org/10.3390/polym15143040 - 14 Jul 2023
Cited by 13 | Viewed by 2313
Abstract
Various 3D printing systems for interim fixed dental restorations are commercially available. This study aimed to evaluate the physical and mechanical properties of 3D printed resins used for interim restorations fabricated using various 3D printing systems and printing angulations after accelerated aging. Three [...] Read more.
Various 3D printing systems for interim fixed dental restorations are commercially available. This study aimed to evaluate the physical and mechanical properties of 3D printed resins used for interim restorations fabricated using various 3D printing systems and printing angulations after accelerated aging. Three different interim restorative materials were provided and printed using their specific 3D printing systems (A: NextDent; B: Asiga; C: Nova3D), and the testing specimens from each system were printed at two building angles: (1) 0° and (2) 90°. The six groups were A1, A2, B1, B2, C1, and C2, with sixteen specimens per group. Half of the specimens in each group (N = 8) were subjected to accelerated aging, including simulated brushing and thermocycling. Three-point bending, surface roughness, and Vickers microhardness tests were performed. Two-way ANOVA and Fisher’s multiple tests were used for statistical analyses. The most accurate systems were found in groups C1 and C2 for length, A1 and B1 for width, and A1 and C1 for height. The specimen trueness only changed after aging for groups B1, B2, and C1. The flexural strength of the A2 group (151 ± 7 MPa) before aging was higher than that of the other groups, and the strength decreased after aging only for groups A1 and A2. The flexural strength, microhardness, and surface roughness of the 3D printed interim resins after aging varied depending on the material, system used, and printing angle. Full article
(This article belongs to the Special Issue Polymers in Restorative Dentistry)
Show Figures

Figure 1

15 pages, 2916 KiB  
Article
Fracture Resistance Analysis of CAD/CAM Interim Fixed Prosthodontic Materials: PMMA, Graphene, Acetal Resin and Polysulfone
by Cristian Abad-Coronel, Carolina Calle, Gabriela Abril, César A. Paltán and Jorge I. Fajardo
Polymers 2023, 15(7), 1761; https://doi.org/10.3390/polym15071761 - 1 Apr 2023
Cited by 6 | Viewed by 2966
Abstract
The aim of this study was to evaluate and compare the fracture resistance of temporary restorations made of polymethylmethacrylate (PMMA), graphene-modified PMMA (GRA), acetal resin (AR) and polysulfone (PS) obtained by a subtractive technique (milling) using a computer-aided design and manufacturing (CAD/CAM) system [...] Read more.
The aim of this study was to evaluate and compare the fracture resistance of temporary restorations made of polymethylmethacrylate (PMMA), graphene-modified PMMA (GRA), acetal resin (AR) and polysulfone (PS) obtained by a subtractive technique (milling) using a computer-aided design and manufacturing (CAD/CAM) system of a three-unit fixed dental prosthesis (FDP). Methods: Four groups of ten samples were fabricated for each material. Each specimen was characterized by a compression test on a universal testing machine, all specimens were loaded to fracture and the value in Newtons (N) was recorded by software connected to the testing machine. The fracture mode was evaluated on all samples using a stereomicroscope. Results: There were statistically significant differences (p value < 0.005) between PMMA and the other three materials (PMMA: 1302.71 N; GRA: 1990.02 N; RA: 1796.20 N; PS: 2234.97). PMMA presented a significantly lower value than the other materials, and PS showed the highest value. GRA and RA presented a similar range of values but they were still higher than those of PMMA. Conclusions: GRA, RA and PS are presented as valid options within the range of interim milled restorative materials and as alternatives to PMMA. Full article
(This article belongs to the Special Issue Advanced Polymeric Materials for Dental Applications II)
Show Figures

Figure 1

19 pages, 544 KiB  
Systematic Review
Marginal Fit, Mechanical Properties, and Esthetic Outcomes of CAD/CAM Interim Fixed Dental Prostheses (FDPs): A Systematic Review
by Hussain Al-humood, Amal Alfaraj, Chao-Chieh Yang, John Levon, Tien-Min Gabriel Chu and Wei-Shao Lin
Materials 2023, 16(5), 1996; https://doi.org/10.3390/ma16051996 - 28 Feb 2023
Cited by 11 | Viewed by 4258
Abstract
This systematic review aimed to study the outcomes of CAD-CAM (milled and 3D-printed) interim dental prostheses when compared to conventional ones. The focused question of “In natural teeth, what are the outcomes of CAD-CAM interim FDPs compared to the conventionally-manufactured ones regarding marginal [...] Read more.
This systematic review aimed to study the outcomes of CAD-CAM (milled and 3D-printed) interim dental prostheses when compared to conventional ones. The focused question of “In natural teeth, what are the outcomes of CAD-CAM interim FDPs compared to the conventionally-manufactured ones regarding marginal fit, mechanical properties, esthetics, and color stability” was formulated. The systematic search was conducted electronically in the PubMed/MEDLINE, CENTRAL, EMBASE, Web of Science, New York Academy of Medicine Grey Literature Report, and Google Scholar databases by using the MeSH keywords and keywords associated with the focused question and limiting articles to those published between 2000 and 2022. A manual search was conducted in selected dental journals. The results were analyzed qualitatively and are presented in table format. Of the included studies, 18 studies were in vitro and 1 was a randomized clinical trial. Of the eight studies analyzing the mechanical properties, five studies favored the milled interim restorations, one study favored both 3D-printed and milled interim restorations, and two studies reported better mechanical properties in conventional interim restorations. Among four studies evaluating the marginal discrepancies, two studies favored the marginal fit in milled interim restorations, one study reported a better marginal fit in both milled and 3D-printed interim restorations, and one study found conventional interim restorations have a better marginal fit and smaller marginal discrepancy when compared to both milled and 3D-printed restorations. Among five studies that evaluated both the mechanical properties and marginal fit, 1 study favored 3D-printed interim restorations and four studies favored milled interim restorations over the conventional ones. Two studies analyzing the esthetics outcomes demonstrated better results with milled interim restorations compared to conventional and 3D-printed interim restorations in terms of their color stabilities. The risk of bias was low for all the studies reviewed. The high level of heterogeneity within the studies excluded meta-analysis. Most of the studies favored the milled interim restorations over the 3D-printed and conventional restorations. The results suggested that milled interim restorations offer a better marginal fit, higher mechanical properties, and better esthetic outcomes in terms of color stabilities. Full article
(This article belongs to the Special Issue Additive Manufacturing of Ceramics and Polymers in Dentistry)
Show Figures

Figure 1

11 pages, 2345 KiB  
Article
Comparative Evaluation of Flexural Strength of Four Different Types of Provisional Restoration Materials: An In Vitro Pilot Study
by Hafsa Al Idrissi, Lovely Muthiah Annamma, Dalya Sharaf, Ahmad Al Jaghsi and Huda Abutayyem
Children 2023, 10(2), 380; https://doi.org/10.3390/children10020380 - 15 Feb 2023
Cited by 6 | Viewed by 3746
Abstract
With provisional restorations, properties such as flexural strength play a key role in maintaining the abutment teeth in position over the interim period until the final restorations are placed. This study aimed to evaluate and compare the flexural strength of four commonly used [...] Read more.
With provisional restorations, properties such as flexural strength play a key role in maintaining the abutment teeth in position over the interim period until the final restorations are placed. This study aimed to evaluate and compare the flexural strength of four commonly used provisional resin materials. Ten identical 25 × 2 × 2 mm specimens were made from four different groups of provisional resin material, namely 1: SR Ivocron (Ivoclar Vivadent) cold-polymerized poly-methyl methacrylate (PMMA), 2: S Ivocron (Ivoclar Vivadent) heat-polymerized PMMA, 3: Protemp (3M Germany-ESPE) auto-polymerized bis-acryl composite, and 4: Revotek LC (GC Corp, Tokyo) light-polymerized urethane dimethacrylate resin. The mean values of the flexural strength of each group were calculated and the data were analyzed using one-way ANOVA and Tukey post hoc tests. The mean values (MPa) were as follows: for cold-polymerized PMMA, it was 125.90 MPa; for heat-polymerized PMMA, it was 140.00 MPa, with auto-polymerized bis-acryl composite 133.00 MPa; and for light-polymerized urethane dimethacrylate resin, it was 80.84 MPa. Thus, the highest flexural strength was recorded with heat-polymerized PMMA and the lowest flexural strength with light-polymerized urethane dimethacrylate resin, which was significantly low. The study did not detect a significant difference in the flexural strengths of cold PMMA, hot PMMA, and auto bis-acryl composite. Full article
(This article belongs to the Special Issue Biomaterials and Biomechanics of Pediatric Dentistry)
Show Figures

Figure 1

13 pages, 56991 KiB  
Article
Clinical Reliability of Complete-Arch Fixed Prostheses Supported by Narrow-Diameter Implants to Support Complete-Arch Restorations
by Claudia Lorenzi, Fabrizio Lio, Piero Papi, Vincenzo Mazzetti, Andrea Laureti and Claudio Arcuri
Appl. Sci. 2023, 13(1), 538; https://doi.org/10.3390/app13010538 - 30 Dec 2022
Cited by 5 | Viewed by 2250
Abstract
The aim of this study was to evaluate the clinical application of fixed screw-retained complete-arch rehabilitations supported by four narrow-diameter implants (NDIs). The records of patients treated with complete-arch prostheses screwed onto four NDIs treated with an immediate loading protocol between 2010 and [...] Read more.
The aim of this study was to evaluate the clinical application of fixed screw-retained complete-arch rehabilitations supported by four narrow-diameter implants (NDIs). The records of patients treated with complete-arch prostheses screwed onto four NDIs treated with an immediate loading protocol between 2010 and 2020 with at least 1 year of follow-up after the positioning of the definitive restoration were reviewed. The implants were placed according to the final prosthetic design and were immediately loaded. The interim prostheses were replaced after the healing period by definitive acrylic resin titanium-supported prostheses. Patients were followed to evaluate treatment success, the implant survival rate (ISR), and the prosthetic survival rate (PSR). A total of 121 NDIs were positioned in 30 patients to restore 30 complete arches (18 maxilla and 12 mandible). One implant did not achieve osseointegration, resulting in an overall ISR of 99.2%. No prosthetic or implant failures occurred during the 1 to 11 years of follow-up. Three biological and four prosthetic complications occurred, resulting in a treatment rehabilitation survival of 94.1% and a PSR of 86.7%. Despite the limitations of the present retrospective study, such as the use of one single type of dental implant and patients treated in a single rehabilitation center, complete-arch rehabilitation with fixed prostheses supported by four NDIs seems to be a reliable treatment in the medium to long term. Full article
(This article belongs to the Special Issue Novel Biomaterial and Implant in Dentistry)
Show Figures

Figure 1

11 pages, 1174 KiB  
Article
Colour Changes of Acetal Resins (CAD-CAM) In Vivo
by Cristina Gómez-Polo, Ana María Martín Casado, Norberto Quispe, Eva Rosel Gallardo and Javier Montero
Appl. Sci. 2023, 13(1), 181; https://doi.org/10.3390/app13010181 - 23 Dec 2022
Cited by 5 | Viewed by 2728
Abstract
To quantify the discolouration of the temporary acetal resins in vivo, based on the weeks of follow-up and the salivary pH in the three thirds of the tooth. To find out if the final CIELAB coordinates can be predicted from the initial colour [...] Read more.
To quantify the discolouration of the temporary acetal resins in vivo, based on the weeks of follow-up and the salivary pH in the three thirds of the tooth. To find out if the final CIELAB coordinates can be predicted from the initial colour coordinates, the salivary pH, the situation (in thirds) and the weeks of follow-up. Colour coordinates (L, C, and h) were recorded by spectrophotometry in 13 participants fitted with hybrid provisional complete dentures made of acetal resin. Colour recordings were made on the day of placement and after several weeks of follow-up (6 to 31 weeks). Salivary pH was also measured as a predictor variable for colour change. The ANOVA statistical test and regression models have been used. The highest colour difference according to ∆Eab* was 27.46 units after 15 weeks of follow-up and the lowest was 7.34 units after 17 weeks of follow-up. Neither in the cervical nor in the middle third any regressor variable (initial L*, initial C*, initial h*, salivary pH and weeks of follow-up) was able to significantly predict any of the final colour coordinates (p > 0.05). The colour change of the temporary acetal resins used exceeds the threshold of clinical acceptability, and it is not acceptable to maintain satisfactory aesthetics. The weeks of follow-up and the salivary pH are not capable of satisfactorily predicting the final color coordinates of the acetal resins. Full article
(This article belongs to the Special Issue New Techniques, Materials and Technologies in Dentistry)
Show Figures

Figure 1

14 pages, 4200 KiB  
Article
The Effect of the Digital Manufacturing Technique, Preparation Taper, and Cement Type on the Retention of Aged Anterior Provisional Crowns: An In Vitro Study
by Honey Lunkad, Mohammed E. Sayed, Abdullah Essa Alhazmi, Bandar Alwadani, Ameen Marwei Shafei, Muath Naji Ayoub, Maan Mohammed A. Shabi, Sara Ahmad Mesawa, Basmah Alhassan Abdulfatah, Hatem Alqarni, Saeed M. Alqahtani, Ahmed Alamoudi, Mohammed Salman Almalki, Ankur Jethlia and Saurabh Jain
Appl. Sci. 2022, 12(24), 12714; https://doi.org/10.3390/app122412714 - 11 Dec 2022
Cited by 2 | Viewed by 2701
Abstract
A well-made provisional fixed prosthesis must present as a preview of the future prosthesis and may also augment the health of the abutments and periodontium. Provisional restorations have been prepared chairside with polymethyl methacrylate (PMMA) since time immemorial. CAD/CAM additive and subtractive technologies [...] Read more.
A well-made provisional fixed prosthesis must present as a preview of the future prosthesis and may also augment the health of the abutments and periodontium. Provisional restorations have been prepared chairside with polymethyl methacrylate (PMMA) since time immemorial. CAD/CAM additive and subtractive technologies have revolutionized the fabrication of interim restorations in dental clinics. The current literature lacks substantial data about retention of provisional crowns manufactured using Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) additive and subtractive techniques with various temporary cements. This in vitro study aims to assess and compare the retention of temporary/provisional anterior crowns based on the combined effect of different digital manufacturing techniques, preparation tapers, and the temporary cements used for cementation. Two maxillary right central incisor typodont teeth were prepared to receive all-ceramic crowns, one with a 10-degree taper and the other with a 20-degree taper. Forty 3D-printed working models with the 10° taper and forty working models with the 20° taper were prepared to receive the temporary crowns. Forty temporary crowns were 3D-printed and forty crowns were milled (20 from each taper group). Kerr Temp-Bond NE conventional cement and Kerr Temp-Bond clear cement were used for cementation in the two groups. The number of samples per test group was 10. All samples were thermocycled and subjected to a universal testing machine to measure the pull-off force until retention loss (N) under tension with a crosshead speed of 5 mm/min. The pull-off force was highest for group 8, i.e., 3D-printed crowns with a 20° taper and cemented with Kerr Temp-Bond clear cement, followed by groups 6, 7, 4, 5, 3, and 2. Group 1, i.e., milled crowns with 10° taper cemented with Kerr Temp-Bond NE conventional cement, exhibited the lowest pull-off retentive force. The clinical selection of long-term provisional crowns fabricated using 3D-printing technology, prepared with 10° or 20° tapers, and cemented with clear cement, is the most favorable in terms of the retention of provisional crowns. 3D-printed provisional crowns can be used as an alternative to conventional and CAD/CAM-milled crowns for long-term provisionalization. Full article
Show Figures

Figure 1

12 pages, 993 KiB  
Article
Challenging Endocrine Sensitivity of Hormone Receptor-Positive/HER2-Negative Advanced Breast Cancer with the Combination of Eribulin and Endocrine Therapy: The REVERT Study
by Ana López González, Sonia Del Barco Berrón, Isabel Grau, Maria Galan, Beatriz Castelo Fernández, Alfonso Cortés, Pedro Sánchez Rovira, Alejandro Martinez-Bueno, Xavier Gonzalez, Almudena García, Petra Gener, Leonardo Mina, Daniel Alcalá-López, Miguel Sampayo, Javier Cortés, José Manuel Pérez-Garcia, Antonio Llombart-Cussac and Elena López-Miranda
Cancers 2022, 14(23), 5880; https://doi.org/10.3390/cancers14235880 - 29 Nov 2022
Cited by 3 | Viewed by 2387
Abstract
Background: Luminal advanced breast cancer (ABC) patients eventually progress on endocrine therapy. REVERT aimed to explore whether eribulin could restore endocrine sensitivity in a randomized, non-comparative phase II trial. Methods: Aromatase inhibitor (AI)-resistant patients with luminal ABC were randomized 1:1 to receive eribulin [...] Read more.
Background: Luminal advanced breast cancer (ABC) patients eventually progress on endocrine therapy. REVERT aimed to explore whether eribulin could restore endocrine sensitivity in a randomized, non-comparative phase II trial. Methods: Aromatase inhibitor (AI)-resistant patients with luminal ABC were randomized 1:1 to receive eribulin +/− AI. Patients were stratified by prior cyclin-dependent kinases 4/6 inhibitor (CDK4/6i) treatment. The primary endpoint was an investigator-assessed overall response rate (ORR) according to RECIST version 1.1 in the eribulin + AI arm. An interim analysis was planned with 11 evaluable patients according to a two-stage Simon design. Results: Twenty-two patients were enrolled (15 eribulin + AI arm; 7 eribulin arm). The trial was terminated early in March 2021, with eight (36.4%) patients still on treatment. ORR was 26.7% in the eribulin + AI arm (95% CI, 7.8–55.1%; p = 0.0541). In the eribulin arm, two (28.6%) patients had an objective response (95% CI, 3.7–71.0%). The difference between the study arms was not significant (p = 0.918). The addition of AI to eribulin also failed to show improvement in other efficacy endpoints. A significant interaction between the treatment arm and previous CDK4/6i treatment was observed for ORR (p = 0.018) and progression-free survival (p = 0.084). Overall, the toxicity profile was consistent with the known safety profile of eribulin. No treatment-related deaths were reported. Conclusion: Eribulin + AI does not seem to improve outcomes compared with eribulin monotherapy in patients with AI-resistant luminal ABC. This chemo–endocrine approach deserves further investigation after progression to CDK4/6i-based therapy. Full article
(This article belongs to the Section Clinical Research of Cancer)
Show Figures

Figure 1

33 pages, 2529 KiB  
Review
Marginal Adaptation and Internal Fit of 3D-Printed Provisional Crowns and Fixed Dental Prosthesis Resins Compared to CAD/CAM-Milled and Conventional Provisional Resins: A Systematic Review and Meta-Analysis
by Mohammed Hussain Dafer Al Wadei, Mohammed E. Sayed, Saurabh Jain, Aparna Aggarwal, Hatem Alqarni, Shilpi Gilra Gupta, Saeed M. Alqahtani, Nasser M. Alahmari, Abdullah Hasan Alshehri, Meena Jain, Abrar A. Ageeli, Saad Saleh AlResayes, Samar Alghamdi, Alhanouf K. Alnajdi and Mafaz M. Gharawi
Coatings 2022, 12(11), 1777; https://doi.org/10.3390/coatings12111777 - 20 Nov 2022
Cited by 20 | Viewed by 5939
Abstract
The aim of this systematic review was to evaluate the marginal fit and internal adaptation of provisional crowns and fixed dental prostheses (FDPs) fabricated using 3D-printing resins and compared them with those fabricated by CAD/CAM (computer-aided designing/computer-aided manufacturing) milling and conventional resins. The [...] Read more.
The aim of this systematic review was to evaluate the marginal fit and internal adaptation of provisional crowns and fixed dental prostheses (FDPs) fabricated using 3D-printing resins and compared them with those fabricated by CAD/CAM (computer-aided designing/computer-aided manufacturing) milling and conventional resins. The null hypotheses tested were that there would be no differences in the marginal fit and internal adaptation of 3D-printed provisional crowns and FDP resins when compared to CAD/CAM-milled and conventional provisional resins. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used to construct this systematic review. The focused PICO/PECO (Population, Intervention/Exposure, Comparison, Outcome) question was “Do provisional crowns and FDPs (P) fabricated by 3D-printing (I) have similar marginal adaptation and internal fit (O) when compared to those fabricated by CAD/CAM milling and conventional techniques (C)?”. The protocol used for this systematic review was pre-registered in the International Prospective Register of Systematic Reviews (PROSPERO). Electronic databases (e.g., MEDLINE/PubMed and Web of Science (Core Collection)) were systematically searched for indexed English literature published up to June 2022. In the initial electronic search of the selected databases, 519 articles were identified. Duplicates were removed, and screening was performed to select the articles that met the preset inclusion criteria. Sixteen studies were selected for qualitative analysis, but only ten of them provided comparative data and were selected for quantitative analysis. The modified CONSORT scale was used for qualitative analysis, and most of the included studies were rated to be of moderate quality. Based on the findings, it could be concluded that provisional crowns and FDPs fabricated from 3D-printing resins have a superior marginal fit and internal adaptation when compared to CAD/CAM-milled and conventional provisional resins; thus, they can be used as a dependable alternative to other resins. Full article
(This article belongs to the Special Issue Surface Modifications and Coatings for Implantable Biomaterials)
Show Figures

Figure 1

Back to TopTop