Next Article in Journal
Numerical Calculation Method of Deflection Deformation of Rice Stalk
Previous Article in Journal
Hierarchical Guided-Image-Filtering for Efficient Stereo Matching
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Correction

Correction: Piatkevich et al. Advances in Engineering and Application of Optogenetic Indicators for Neuroscience. Appl. Sci. 2019, 9, 562

by
Kiryl D. Piatkevich
1,*,
Mitchell H. Murdock
1 and
Fedor V. Subach
2,3,*
1
Media Lab, McGovern Institute for Brain Research, and Department of Brain and Cognitive Sciences, MIT, Cambridge, MA 02139, USA
2
INBICST, Moscow Institute of Physics and Technology, 123182 Moscow, Russia
3
Kurchatov Institute National Research Center, 123182 Moscow, Russia
*
Authors to whom correspondence should be addressed.
Appl. Sci. 2019, 9(15), 3123; https://doi.org/10.3390/app9153123
Submission received: 12 June 2019 / Accepted: 10 July 2019 / Published: 1 August 2019
We, the authors, wish to make the following corrections to our paper [1]. We found typos in Table 3 for the fluorescence spectrum peaks and kinetics of the Gluu sensor. These typos resulted in an incorrect statement in the main text:
“Similar temporal resolution was also achieved by the iGluSnFR-S72T point mutant, named iGluu (u stands for “ultrafast”), although it suffered from 1.5-fold lower sensitivity than SF-iGluSnFR-S72A under similar imaging conditions (Table 3).”
We would like to correct the values in the Table 3 and corresponding sentences in the main text. Thus, Table 3 and the statement would be changed to:
iGluuGlu a490/510170530.73Not tested[129]
“Even higher temporal resolution was achieved by the iGluSnFR-S72T point mutant, named iGluu (u stands for “ultrafast”) [129], which was able to resolve responses at single synapses in hippocampal slices during single action potentials evoked even at frequencies of 100 Hz. However, it showed about 1.5-fold lower sensitivity than SF-iGluSnFR-S72A under similar imaging conditions (Table 3). Overall, the kinetics and sensitivity of SF-iGluSnFRs and iGluu make them superior to the fastest green calcium sensor GCaMP6f in terms of monitoring presynaptic activity, as was demonstrated for granule cell axons within mouse cerebellar brain slices.”
The authors would like to apologize for any inconvenience caused. The manuscript will be updated, and the original version will remain online on the article webpage.

Reference

  1. Piatkevich, K.D.; Murdock, M.H.; Subach, F.V. Advances in Engineering and Application of Optogenetic Indicators for Neuroscience. Appl. Sci. 2019, 9, 562. [Google Scholar] [CrossRef]

Share and Cite

MDPI and ACS Style

Piatkevich, K.D.; Murdock, M.H.; Subach, F.V. Correction: Piatkevich et al. Advances in Engineering and Application of Optogenetic Indicators for Neuroscience. Appl. Sci. 2019, 9, 562. Appl. Sci. 2019, 9, 3123. https://doi.org/10.3390/app9153123

AMA Style

Piatkevich KD, Murdock MH, Subach FV. Correction: Piatkevich et al. Advances in Engineering and Application of Optogenetic Indicators for Neuroscience. Appl. Sci. 2019, 9, 562. Applied Sciences. 2019; 9(15):3123. https://doi.org/10.3390/app9153123

Chicago/Turabian Style

Piatkevich, Kiryl D., Mitchell H. Murdock, and Fedor V. Subach. 2019. "Correction: Piatkevich et al. Advances in Engineering and Application of Optogenetic Indicators for Neuroscience. Appl. Sci. 2019, 9, 562" Applied Sciences 9, no. 15: 3123. https://doi.org/10.3390/app9153123

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop