Next Article in Journal
Driver Attention Assessment Using Physiological Measures from EEG, ECG, and EDA Signals
Previous Article in Journal
A Mapless Local Path Planning Approach Using Deep Reinforcement Learning Framework
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Communication

Breaking of Wavelength-Dependence in Holographic Wavefront Sensors Using Spatial-Spectral Filtering

1
Lebedev Physical Institute, Russian Academy of Sciences, Leninskiy Prospekt 53, Moscow 119991, Russia
2
Department of Laser Physics, National Research Nuclear University MEPhI, 31 Kashirskoe Shosse, Moscow 115409, Russia
*
Author to whom correspondence should be addressed.
Sensors 2023, 23(4), 2038; https://doi.org/10.3390/s23042038
Submission received: 2 January 2023 / Revised: 8 February 2023 / Accepted: 9 February 2023 / Published: 10 February 2023
(This article belongs to the Section Optical Sensors)

Abstract

:
Nowadays, wavefront sensors are widely used to control the shape of the wavefront and detect aberrations of the complex field amplitude in various fields of physics. However, almost all of the existing wavefront sensors work only with quasi-monochromatic radiation. Some of the methods and approaches applied to work with polychromatic radiation impose certain restrictions. However, the contemporary methods of computer and digital holography allow implementing a holographic wavefront sensor that operates with polychromatic radiation. This paper presents a study related to the analysis and evaluation of the error in the operation of holographic wavefront sensors with such radiation.

1. Introduction

Currently, wavefront sensors (WFS) are widely used to solve a multitude problems in various fields of physics, namely to control the shape of a wavefront or detect aberrations of the complex field amplitude [1]. These devices include the well-known Shack–Hartmann wavefront sensor [2,3], curvature sensors [4], pyramidal sensors [5,6], and holographic WFSs [7,8,9]. The principle of the first three sensors is based on analyzing the intensity distribution of an image or set of images using a 2D image sensor. In turn, holographic WFSs are built on the principle of converting the phase of a light wave into its intensity due to the spatial filtering of radiation using holograms. Traditionally, holograms were obtained physically by transferring the intensity distribution of the interference pattern to a photographic emulsion [10]. A disadvantage of holographic WFSs based on such holograms is that they cannot detect several complex field amplitude aberrations at once [11].
Therefore, the next stage in the development of holographic WFSs was the use of multiplexed holograms [12,13]. Here, multiplexed refers to a hologram resulting from the recording of two or more holograms in the same area of a photosensitive medium. The use of such elements increases the performance of the method and reduces the sensitivity of the sensor to amplitude and phase fluctuations [14]. However, as it is known from [15], the diffraction efficiency of such holograms decreases in inverse proportion to the square of the number of holograms due to the limitations of the recording media. This leads to a significant reduction in the intensity of the reconstructed waves for each hologram component. In addition, intermodal (crosstalk) noise is generated during the reconstruction of multiplexed holograms, resulting in a reduction of the signal-to-noise ratio in the analysis plane [16].
The next step in improving holographic methods was the use of computer technology to synthesize holograms [17]. With the development of computer and digital holography methods, the process of creating holograms became more digitalized, which led to the creation of new elements, the synthesis of which was fully realized in a computer. Such holograms are called computer-generated holograms (CGHs) [18,19]. Over the past 20 years, spatial light modulators (SLMs) have been increasingly used in optics [20]. They allow discrete modulation of the amplitude or phase component of a light wave with high spatial resolution. The appearance of such devices allowed holographic WFSs to make a significant leap forward, while opening up new opportunities in various fields of science and technology [21].
Almost all of the existing WFS can work only with monochromatic radiation. The methods and approaches used when working with polychromatic radiation impose certain restrictions [22]. Recently however, a fundamental demonstration of a holographic WFS was carried out that could work with polychromatic radiation due to the achromatic properties of the Fourier CGHs [23]. The operation of this holographic WFS was based on the principles of correlation analysis [24]. However, the assessment of the factors affecting the operation of the sensor was not carried out. This paper presents a detailed theoretical and experimental analysis of the features of the operation of such a correlation holographic WFS with polychromatic radiation.

2. Materials and Methods

The principle of operation of the holographic WFS used in the work was as follows: a coherent beam with phase distortion is incident on the Fourier CGH, then the reflection from the SLM radiation enters the aperture of the Fourier Transforming Lens (FTL). This radiation is then focused by the FTL into the plane where the 2D image sensor is installed. In general, when using a Fourier CGH, several diffraction orders are observed in the analysis plane at once [24] (Figure 1). By the intensity and size of these diffraction orders, it is possible to judge the presence and magnitude of the aberration contained in the incident beam of the hologram. When the amplitude of the distortion in the incident light beam coincides with the value of the weight coefficient of the Zernike polynomial recorded in the CGH, an autocorrelation response will be observed in the posterior focal plane of the FTL [25].
The presence of higher diffraction orders in the analysis plane leads to a redistribution of energy between the orders and may cause a decrease in the sensitivity of the method. The solution to this problem was found in the field of computer holography methods, which generally allow increasing the diffraction efficiency due to the formation of only one main diffraction maximum in the Fraunhofer diffraction [26].
This kind of redistribution of energy between diffraction orders in the Fraunhofer diffraction pattern can be achieved using a phase hologram [23,27], whose phase argument can be described by a similar equation
h p h ( x , y ) = exp ( j · 2 π · [ f r e f ( x , y ) Δ λ f y ] ) .
where f r e f ( x , y ) is a spatial phase shift produced by aberration, which is independent from λ. It can be presented as:
f r e f ( x , y ) = n C n · W n ( x , y )
where C n is the set of Zernike coefficients, and W n ( x , y ) is the Zernike polynomials that have been first defined in polar coordinates and then converted into Cartesian coordinates using well-known techniques [28].
During the operation of a holographic WFS, which includes a phase SLM, theoretically the modulation response should be linear and be in the desired range for a specific reference wavelength λ 0 of radiation [29]. To date, there are many methods and approaches for self-calibration of modulators and correction of their gamma curve [30]. After calibration of the SLM for the wavelength λ 0 , the phase shift φ formed due to the double pass is equal to
φ ( λ 0 ) = 2 π λ 0 · Δ n ( λ 0 ) · 2 d ,
where Δ n ( λ 0 ) is the refractive index range, and d is the liquid crystal thickness. In the case where the radiation wavelength of the aberration beam does not correspond to the reference wavelength λ 0 , the type of dependence of the phase overrun on the SLM parameters will not change
φ ( λ ) = 2 π λ · Δ n ( λ ) · 2 d .
If we express d from Equation (3) and substitute it into Equation (4), then the values of phase incursions can be related to each other by the following relation
φ ( λ ) = λ 0 λ · Δ n ( λ ) Δ n ( λ 0 ) · φ ( λ 0 ) .
The discrepancy between the reference wavelength λ 0 and λ leads to a change in the radiation modulation depth. Since the phase function of the reference wave in the Fourier CGH corresponds to the phase function of the one-dimensional blaze grating (Figure 2a), its effective operation requires complete phase modulation of the radiation in the range [0, 2π). If this condition is met, then in accordance with Equation (1), all radiation can be concentrated in the main diffraction maximum [26]. If the condition is not met, this will lead to the appearance of higher diffraction orders. This effect is clearly demonstrated by the example of several distribution periods of the phase argument of the function of the object and reference waves.
Figure 2a shows the phase function profile of the object wave for the case when the reference wavelength is λ 0 = λ and λ 0 λ . By analogy, Figure 2b considers the case for the reference wave in which there is distortion in the form of a defocusing aberration with a weighting factor of 4 λ .
It is interesting that Equation (5) does not depend on the chromatic dispersion of the liquid crystal Δ n ( λ ) Δ n ( λ 0 ) but depends only on the ratio of the wavelengths λ 0 and λ . If we take into account the fact that the effective refractive index range Δ n ( λ ) can be adjusted to the Cauchy dispersion model, then for a certain wavelength λ the relation will have the following form
Δ n ( λ ) Δ n ( λ 0 ) 0.6985 + 8.125 · 10 4 λ 2 + 8.125 · 10 5 λ 4 .
In this case, the determining factor is that the carrier frequency of the phase jump repetition (i.e., the transition from the maximum to the minimum value) during Fourier CGH modulation remains unchanged even when the radiation wavelength parameter λ is changed. Hence, the modulation depth of the SLM and the Fourier CGH do not affect the principles of correlation response formation. This allows us to extend the functionality of holographic WFSs by replacing the grayscale Fourier CGHs with binary Fourier CGHs and switching from SLM-type devices to digital micromirror devices (DMD)-type, which have much higher operation frequency. It will also greatly simplify the procedure of CGH synthesis used in holographic WFSs, as well as their modulation, as the requirements for phase distribution transfer are significantly relaxed.

3. Experimental Demonstration

An experimental demonstration of the Fourier CGH properties was carried out using several sources of coherent radiation (lasers with a wavelength of λ 1 = 473 nm, λ 2 = 532 nm and λ 3 = 561 nm), an SLM (Holoeye PLUTO-2-VIS-016, 1920 × 1080, pixel size 8 µm) and a monochrome sCMOS camera (Thorlabs CS2100M-USB, 1920 × 1080, pixel size 5.04 µm). Each of the laser beams was expanded to 4 mm and collimated using a Kepler telescopic system. The convergence of these beams on the same optical axis was carried out using beam-splitting cubes. Figure 3 shows the equivalent optical scheme, which depicts only the main elements of the holographic WFS.
Aberrations of the complex field amplitude were introduced into the optical system using a biconvex lens (Lens 1) with a focal length f = 100 mm. Due to the dispersion properties of the lens, the rear focal plane has an extended size along the radiation propagation axis when it is illuminated by radiation with different wavelengths. A Shack–Hartmann wavefront sensor (WFS, Thorlabs WFS300-14AR) with a passport error of λ/50, which measured the value of the aberration of the complex field amplitude in real time (at a frequency of 15 Hz), was used as a control and measuring device. The measurement of aberration by the proposed method was carried out using the SLM, an achromatic FTL (Lens 2) in the range from 0.3 to 0.8 μm and an sCMOS camera, which was located in the rear focal plane of this lens.
Holograms were synthesized before the start of the experiment. Then, they were iteratively displayed on the SLM. Each of the holograms was synthesized for one value of the weight coefficient of the Zernike polynomial. Examples of the grayscale Fourier CGHs used in the experiment are shown in Figure 4, where the hologram on the left was synthesized with the value of the weight coefficient in the reference beam equal to 0.53λ, and on the right the value was equal to 1.33λ.
The experiment consisted of two parts, in each of which either grayscale Fourier CGHs or binary ones were used. In each block, the experiment was repeated for each laser separately. In this case, the SLM settings associated with the gamma curve were chosen for the following reference wavelength λ 0 : 450 nm, 515 nm, 532 nm and 633 nm. The modulation depth was [0, 2π) at the wavelength λ 0 . After the completion of the experimental cycle with grayscale Fourier CGHs, the entire experiment described above was carried out using binary Fourier CGHs. To do this, the previously calculated holograms were binarized using the Otsu method. Figure 4c,d show the binary Fourier CGHs from Figure 4a,b.
The output of the holograms on the SLM produced a main diffraction maximum in the rear focal plane of Lens 2 that corresponds to the correlation response. Since the SLM and the sCMOS camera were connected in feedback mode via a PC, it is possible to establish a one-to-one relationship between the maximum intensity of the correlation response and the value of the weight coefficient of the Zernike polynomial recorded in the grayscale Fourier CGHs. Examples of the correlation responses recorded in the experiment are shown in Figure 5. These responses were obtained for the holograms shown in Figure 4. All obtained values were normalized to the maximum intensity value for the selected CMOS camera (Imax = 216).
The amplitude of the correlation response varies with the grayscale Fourier CGH output to the SLM. This can be seen in Figure 5. After the intensity distributions were recorded, a global maximum of the two-dimensional distribution was searched using specialized software in the Python environment. The dependence corresponding to the normalized amplitude of the correlation function maxima on the value of the Zernike polynomial weight coefficient was formed on the basis of the obtained values. The maximum value of the function was formed when the value of the weight coefficient of the Zernike polynomial in the CGH Fourier coincided with the value of the aberration of the complex field amplitude in the beam. An example of such a dependence for the defocusing aberration is shown in Figure 6b, where the corresponding colored dots indicate the values of the global maximum taken from Figure 6a.

4. Results and Discussion

The results of the experiments were normalized dependencies of the amplitude of the maximum of the correlation function, the appearance of which is shown in Figure 7. All obtained values were normalized to the maximum intensity value for the selected CMOS camera (Imax = 216) and averaged over 10 points.
If we consider the results in detail, we can see that the experimental dependences have a symmetrical profile, one global maximum, a high growth rate of the function and a large signal-to-noise ratio. Their distinguishing feature is only the different value of the maximum of the correlation function. Figure 7a–c show the dependence of the maximum amplitude of the correlation function on the parameters of the SLM, which are associated with the reference wavelength λ 0 .
If we assume that the spectral sensitivity of the SLM and the sCMOS camera in the visible range is the same, then this effect can only be explained by the different diffraction efficiency of the Fourier CGHs displayed on the SLM due to phase overmodulation. This leads to the appearance of high-level diffraction orders. Consequently, when they appear, the intensity of the main diffraction maximum will decrease. As a result, the maximum amplitude of the correlation function will change, which is observed in Figure 7d. In the case of using binary Fourier CGHs, the phase function profile of the reference wave changes from oblique to rectangular. Theoretically, in this case only 25% of the energy from the entire light flux can be concentrated in the main diffraction maximum [26].
If you look at the experimental data presented in Figure 8, you can see that when going from the grayscale Fourier CGHs to the binary one, the intensity drop in the main diffraction maximum is not the same for different wavelengths. When calculating the absolute value of the intensity drop for lasers with different wavelengths, the following values were obtained: for λ 1 = 473 nm, the value was 5.78%, for λ 2 = 532 nm, the value was 18.44%, and for λ 3 = 561 nm, the value was 29.08%.
Changing the value of the main maximum of the correlation function does not affect the accuracy of the method. This can be verified by looking at Figure 9, which shows the results of the method’s accuracy assessment. The results have been normalized to the first experimental value for each case to simplify the visualization process.
From the results obtained, it follows that the best result was obtained for the laser with wavelength λ 1 = 473 nm (Figure 9a), as the maximum deviation of the weighting factor was only λ/31, while for the laser with wavelength λ 2 = 532 nm and λ 3 = 561 nm (Figure 9b,c, respectively), the maximum deviation was λ/18 and λ/13, respectively. Meanwhile, the maximum mean deviation when averaged over 10 points was λ/62.5, λ/38.5 and λ/18, respectively. Despite the fluctuations in the weight coefficients of the Zernike polynomials from their true value, their spatial position remains unchanged when the SLM settings are changed with respect to the reference wavelength λ 0 . This is evidenced by the results shown in Figure 9d. Assuming a sCMOS camera pixel size of only 5.04 μm, the maximum offsets were 4.88, 9.62 and 6.590 μm. This indicates that the angle of diffraction of the radiation does not change when changing the SLM settings.

5. Conclusions

This article shows the influence of the modulation parameters of the used SLM and the obtained grayscale and binary Fourier CGHs when solving the problem of detecting aberrations of the complex field amplitude by the correlation method. The experimental results confirm the theoretical assumptions and prove the applicability of the method when operating in a wide spectral range of wavelengths due to the invariance of the Fourier CGHs themselves to a change in the radiation wavelength of the analyzed wavefront. An analysis of the experimental results shows that with a limited range of phase modulation the method does not lose detection accuracy.
The determining contribution in the proposed method is the profile of the reference wave phase function, which is used in the Fourier CGHs synthesis. The reference wave profile determines the amount of energy in the main diffraction maximum (correlation response) or the value of the signal-to-noise ratio. However, even a significant change in this profile from oblique to rectangular did not distort the results obtained. The replacement of the grayscale Fourier CGHs by binary CGHs allows the DMD to be considered as a phase modulation device, with the advantage of high operating frequencies up to 20 kHz.
Limitations on the spectral range of the studied wave in this method are imposed due to the SLM and the camera. Theoretically, this method is applicable to any spectral range, including UV and IR.

Author Contributions

Conceptualization, N.S.; methodology, N.S. and E.Z.; software, N.S.; validation, M.K.; formal analysis, N.S. and E.Z.; investigation, N.S. and E.Z.; resources, E.Z. and S.K.; data curation, N.S.; writing—original draft preparation, N.S. and M.K.; writing—review and editing, M.K. and E.Z.; visualization, N.S.; supervision, S.K.; project administration, M.K.; funding acquisition, S.K. All authors have read and agreed to the published version of the manuscript.

Funding

The research was financially supported by the Russian Science Foundation (Project No. 21-79-30063).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Data underlying the results presented in this paper are available from the corresponding author upon reasonable request.

Acknowledgments

We thank Iliya Gritsenko for his technical support with the software and George Krasin for his support with the original draft preparation.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Geary, J.M. Introduction to Wavefront Sensors, 1st ed.; SPIE: Bellingham, WA, USA, 1995. [Google Scholar]
  2. Platt, B.C.; Shack, R. History and Principles of Shack-Hartmann Wavefront Sensing. J. Refract. Surg. 2001, 17, S573. [Google Scholar] [CrossRef] [PubMed]
  3. Primot, J. Theoretical description of Shack–Hartmann wave-front sensor. Opt. Commun. 2003, 222, 81–92. [Google Scholar] [CrossRef]
  4. Roddier, F. Curvature sensing and compensation: A new concept in adaptive optics. Appl. Opt. 1988, 27, 1223–1225. [Google Scholar] [CrossRef] [PubMed]
  5. Ragazzoni, R.; Diolaiti, E.; Vernet, E. A pyramid wavefront sensor with no dynamic modulation. Opt. Commun. 2002, 208, 51–60. [Google Scholar] [CrossRef]
  6. Esposito, S.; Riccardi, A. Pyramid Wavefront Sensor behavior in partial correction Adaptive Optic systems. Astron. Astrophys. 2001, 369, L9–L12. [Google Scholar] [CrossRef]
  7. Neil, M.A.A.; Booth, M.J.; Wilson, T. New modal wave-front sensor: A theoretical analysis. J. Opt. Soc. Am. A 2000, 17, 1098–1107. [Google Scholar] [CrossRef]
  8. Khonina, S.N.; Karpeev, S.V.; Porfirev, A.P. Wavefront Aberration Sensor Based on a Multichannel Diffractive Optical Element. Sensors 2020, 20, 3850. [Google Scholar] [CrossRef]
  9. Venediktov, V.Y.; Gorelaya, A.V.; Krasin, G.K.; Odinokov, S.B.; Sevryugin, A.A.; Shalymov, E.V. Holographic wavefront sensors. Quantum Electron. 2020, 50, 614. [Google Scholar] [CrossRef]
  10. Caulfield, H.J. Handbook of Optical Holography, 1st ed.; Academic Press: Cambridge, UK, 1979. [Google Scholar]
  11. Orlov, V.V.; Venediktov, V.Y.; Gorelaya, A.V.; Shubenkova, E.V.; Zhamalatdinov, D.Z. Measurement of Zernike mode amplitude by the wavefront sensor, based on the Fourier-hologram of the diffuse scattered mode. Opt. Laser Technol. 2019, 116, 214–218. [Google Scholar] [CrossRef]
  12. Andersen, G.P.; Dussan, L.C.; Ghebremichael, F.; Chen, K. Holographic wavefront sensor. Opt. Eng. 2009, 48, 085801. [Google Scholar]
  13. Ghebremichael, F.; Andersen, G.P.; Gurley, K.S. Holography-based wavefront sensing. Appl. Opt. 2008, 47, A62–A69. [Google Scholar] [CrossRef] [PubMed]
  14. Booth, M.J. Direct measurement of Zernike aberration modes with a modal wavefront sensor. In Proceedings of the Advanced Wavefront Control: Methods, Devices, and Applications, San Diego, CA, USA, 6–7 August 2003. [Google Scholar]
  15. Collier, R.J.; Burckhardt, C.B.; Li, L.H. Optical Holography, 1st ed.; Academic Press: New York, NY, USA, 1971. [Google Scholar]
  16. Neil, M.A.A.; Booth, M.J.; Wilson, T. Closed-loop aberration correction by use of a modal Zernike wave-front sensor. Opt. Lett. 2000, 25, 1083–1085. [Google Scholar] [CrossRef] [PubMed]
  17. Changhai, L.; Fengjie, X.; Haotong, M.; Shengyang, H.; Zongfu, J. Modal wavefront sensor based on binary phase-only multiplexed computer-generated hologram. Appl. Opt. 2010, 49, 5117–5124. [Google Scholar] [CrossRef] [PubMed]
  18. Lee, W.H. III Computer-Generated Holograms: Techniques and Applications. Prog. Opt. PROG 1978, 16, 119–232. [Google Scholar]
  19. Dallas, W.J. Computer-Generated Holograms. In Digital Holography and Three-Dimensional Display, 1st ed.; Springer: New York, NY, USA, 2006; pp. 1–49. [Google Scholar]
  20. Neff, J.A.; Athale, R.A.; Lee, S.H. Two-dimensional spatial light modulators: A tutorial. Proc. IEEE 1990, 78, 826–855. [Google Scholar] [CrossRef]
  21. Waller, L.; Situ, G.; Fleischer, J. Phase-space measurement and coherence synthesis of optical beams. Nat. Photon. 2012, 6, 474–479. [Google Scholar] [CrossRef]
  22. Kueny, E.; Meier, J.; Levecq, X.; Varkentina, N.; Kärtner, F.X.; Calendron, A.L. Wavefront analysis of a white-light supercontinuum. Opt. Express 2018, 26, 31299–31306. [Google Scholar] [CrossRef]
  23. Stsepuro, N.; Kovalev, M.; Zlokazov, E.; Kudryashov, S. Wavelength-Independent Correlation Detection of Aberrations Based on a Single Spatial Light Modulator. Photonics 2022, 9, 909. [Google Scholar] [CrossRef]
  24. Kovalev, M.S.; Krasin, G.K.; Odinokov, S.B.; Solomashenko, A.B.; Zlokazov, E.Y. Measurement of wavefront curvature using computer-generated holograms. Opt. Express 2019, 27, 1563–1568. [Google Scholar] [CrossRef]
  25. Ruchka, P.A.; Verenikina, N.M.; Gritsenko, I.V.; Zlokazov, E.Y.; Kovalev, M.S.; Krasin, G.K.; Odinokov, S.B.; Stsepuro, N.G. Hardware/Software Support for Correlation Detection in Holographic Wavefront Sensors. Opt. Spectrosc. 2019, 127, 618–624. [Google Scholar] [CrossRef]
  26. Goodman, J.W. Introduction to Fourier Optics, 4th ed.; W.H. Freeman: New York, NY, USA, 2017. [Google Scholar]
  27. Krasin, G.; Kovalev, M.; Stsepuro, N.; Ruchka, P.; Odinokov, S. Lensless Scheme for Measuring Laser Aberrations Based on Computer-Generated Holograms. Sensors 2020, 20, 4310. [Google Scholar] [CrossRef] [PubMed]
  28. Lakshminarayanan, V.; Fleck, A. Zernike polynomials: A guide. J. Mod. Opt. 2011, 58, 545–561. [Google Scholar] [CrossRef]
  29. Calero, V.; García-Martínez, P.; Albero, J.; Sánchez-López, M.M.; Moreno, I. Liquid crystal spatial light modulator with very large phase modulation operating in high harmonic orders. Opt. Lett. 2019, 38, 4663–4666. [Google Scholar] [CrossRef]
  30. Fuentes, J.L.M.; Fernández, E.J.; Prieto, P.M.; Artal, P. Interferometric method for phase calibration in liquid crystal spatial light modulators using a self-generated diffraction-grating. Opt. Express 2016, 24, 14159–14171. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Principle of CGH operation with multiple orders of diffraction.
Figure 1. Principle of CGH operation with multiple orders of diffraction.
Sensors 23 02038 g001
Figure 2. Phase function cross section: (a) object wave; (b) reference wave in the hologram recording plane.
Figure 2. Phase function cross section: (a) object wave; (b) reference wave in the hologram recording plane.
Sensors 23 02038 g002
Figure 3. Simplified experimental scheme.
Figure 3. Simplified experimental scheme.
Sensors 23 02038 g003
Figure 4. Distribution of the phase argument of the CGH with the value of the weight coefficient in the reference beam: (a) 0.53λ for grayscale Fourier CGHs; (b) 1.33λ for grayscale Fourier CGHs; (c) 0.53λ for binary Fourier CGHs; (d) 1.33λ for binary Fourier CGHs.
Figure 4. Distribution of the phase argument of the CGH with the value of the weight coefficient in the reference beam: (a) 0.53λ for grayscale Fourier CGHs; (b) 1.33λ for grayscale Fourier CGHs; (c) 0.53λ for binary Fourier CGHs; (d) 1.33λ for binary Fourier CGHs.
Sensors 23 02038 g004
Figure 5. Correlation response in the output to the SLM of the grayscale and binary Fourier CGH with the value of the weight coefficient of the Zernike polynomial: (a) 0.53λ for grayscale Fourier CGHs; (b) 1.33λ for grayscale Fourier CGHs; (c) 0.53λ for binary Fourier CGHs; (d) 1.33λ for binary Fourier CGHs.
Figure 5. Correlation response in the output to the SLM of the grayscale and binary Fourier CGH with the value of the weight coefficient of the Zernike polynomial: (a) 0.53λ for grayscale Fourier CGHs; (b) 1.33λ for grayscale Fourier CGHs; (c) 0.53λ for binary Fourier CGHs; (d) 1.33λ for binary Fourier CGHs.
Sensors 23 02038 g005
Figure 6. (a) Cross section of the correlation function from the Figure 5a,b; (b) normalized dependences of the amplitude of the maximum correlation response.
Figure 6. (a) Cross section of the correlation function from the Figure 5a,b; (b) normalized dependences of the amplitude of the maximum correlation response.
Sensors 23 02038 g006
Figure 7. The normalized amplitude of the maximum of the correlation function depending on various parameters of the SLM for sources with a wavelength: (a) λ 1 = 473 nm; (b) λ 2 = 532 nm; (c) λ 3 = 561 nm; (d) dependence of maximum correlation function on SLM settings related to reference wavelength λ 0 .
Figure 7. The normalized amplitude of the maximum of the correlation function depending on various parameters of the SLM for sources with a wavelength: (a) λ 1 = 473 nm; (b) λ 2 = 532 nm; (c) λ 3 = 561 nm; (d) dependence of maximum correlation function on SLM settings related to reference wavelength λ 0 .
Sensors 23 02038 g007aSensors 23 02038 g007b
Figure 8. Comparison of the dependence of the maximum of the correlation function on the settings of the SLM relative to the reference wavelength λ0 for the grayscale Fourier CGHs and binary at the wavelength: (a) λ 1 = 473 nm; (b) λ 2 = 532 nm; (c) λ 3 = 561 nm.
Figure 8. Comparison of the dependence of the maximum of the correlation function on the settings of the SLM relative to the reference wavelength λ0 for the grayscale Fourier CGHs and binary at the wavelength: (a) λ 1 = 473 nm; (b) λ 2 = 532 nm; (c) λ 3 = 561 nm.
Sensors 23 02038 g008
Figure 9. Deviation of the value of the weight coefficient of the Zernike polynomial as a function of the SLM tuning associated with the reference wavelength λ 0 for sources with a wavelength: (a) λ 1 = 473 nm; (b) λ 2 = 532 nm; (c) nm; (d) the deviation of the position of the correlation response in the analysis plane.
Figure 9. Deviation of the value of the weight coefficient of the Zernike polynomial as a function of the SLM tuning associated with the reference wavelength λ 0 for sources with a wavelength: (a) λ 1 = 473 nm; (b) λ 2 = 532 nm; (c) nm; (d) the deviation of the position of the correlation response in the analysis plane.
Sensors 23 02038 g009
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Stsepuro, N.; Kovalev, M.; Zlokazov, E.; Kudryashov, S. Breaking of Wavelength-Dependence in Holographic Wavefront Sensors Using Spatial-Spectral Filtering. Sensors 2023, 23, 2038. https://doi.org/10.3390/s23042038

AMA Style

Stsepuro N, Kovalev M, Zlokazov E, Kudryashov S. Breaking of Wavelength-Dependence in Holographic Wavefront Sensors Using Spatial-Spectral Filtering. Sensors. 2023; 23(4):2038. https://doi.org/10.3390/s23042038

Chicago/Turabian Style

Stsepuro, Nikita, Michael Kovalev, Evgenii Zlokazov, and Sergey Kudryashov. 2023. "Breaking of Wavelength-Dependence in Holographic Wavefront Sensors Using Spatial-Spectral Filtering" Sensors 23, no. 4: 2038. https://doi.org/10.3390/s23042038

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop