Next Article in Journal
Physical Conditions Prevailing in the Nasal and Maxillary Sinus Cavities Based on Numerical Simulation
Previous Article in Journal
The Smallpox Vaccine in Latin America: A New Approach (1801–1804)
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Use of High-Resolution Ultrasound in Characterizing the Surface Topography of a Breast Implant

1
Department of Surgery, Kangwon National University, Chuncheon 24289, Republic of Korea
2
Venus Women’s Clinic, Seoul 07727, Republic of Korea
3
Department of Breast Surgery, Gwangju Suwan Hospital, Gwangju 62247, Republic of Korea
4
Department of Radiology, Gwangju Suwan Hospital, Gwangju 62247, Republic of Korea
5
Samsungyubang Breast Clinic, Busan 48104, Republic of Korea
6
The W Clinic, Seoul 06038, Republic of Korea
*
Author to whom correspondence should be addressed.
Medicina 2023, 59(6), 1092; https://doi.org/10.3390/medicina59061092
Submission received: 9 May 2023 / Revised: 19 May 2023 / Accepted: 31 May 2023 / Published: 5 June 2023
(This article belongs to the Section Surgery)

Abstract

Background and Objectives: With the emergence of breast implant-associated anaplastic large cell lymphoma (BIA-ALCL), it has become necessary to identify the implant shell type patients have received. Therefore, an immediate, reliable method for identifying a breast implant shell type is essential. Evidence-based research and applying a real-world technique that identifies the surface topographic information of the inserted breast implants, without surgery, has become of paramount importance for breast implant physicians. Methods and Materials: A review of the medical records of 1901 patients who received 3802 breast implants and subsequently received an ultrasound-assisted examination was performed. All patients received not only a breast cancer examination but also a high-resolution ultrasonography (HRUS) assisted examination of the device at a single center between 31 August 2017 and 31 December 2022. Results: Most patients had breast implants within 10 years (77.7%) of the examination. Of the 3802 implants screened, 2034 (53.5%) were identified with macro-textured shell topography in ultrasonography. A macrotextured shell type implant was used in 53.5% of cases and a smooth type in 42.7% of cases. Seventy-three (1.9%) breast implant shell types could not be identified due to ruptures. However, 250 breast implant shell types could be identified despite rupture cases (6.5%). Conclusions: HRUS was found to be a useful and reliable image modality for identifying various surface shell types of breast implants. The shell type information would be helpful to patients who lack information about their breast implants and are concerned about BIA-ALCL.
Keywords: breast implants; ultrasonography; topography; medical; medical record; lymphoma breast implants; ultrasonography; topography; medical; medical record; lymphoma

Share and Cite

MDPI and ACS Style

Kim, Y.-H.; Park, D.-W.; Song, K.-Y.; Lim, H.-G.; Jeong, J.-P.; Kim, J.-H. Use of High-Resolution Ultrasound in Characterizing the Surface Topography of a Breast Implant. Medicina 2023, 59, 1092. https://doi.org/10.3390/medicina59061092

AMA Style

Kim Y-H, Park D-W, Song K-Y, Lim H-G, Jeong J-P, Kim J-H. Use of High-Resolution Ultrasound in Characterizing the Surface Topography of a Breast Implant. Medicina. 2023; 59(6):1092. https://doi.org/10.3390/medicina59061092

Chicago/Turabian Style

Kim, Yang-Hee, Dong-Wook Park, Keun-Yeong Song, Hyung-Guhn Lim, Jeong-Pil Jeong, and Jae-Hong Kim. 2023. "Use of High-Resolution Ultrasound in Characterizing the Surface Topography of a Breast Implant" Medicina 59, no. 6: 1092. https://doi.org/10.3390/medicina59061092

APA Style

Kim, Y.-H., Park, D.-W., Song, K.-Y., Lim, H.-G., Jeong, J.-P., & Kim, J.-H. (2023). Use of High-Resolution Ultrasound in Characterizing the Surface Topography of a Breast Implant. Medicina, 59(6), 1092. https://doi.org/10.3390/medicina59061092

Article Metrics

Back to TopTop