1. Introduction
Within the increasing demand of the transport sector comes the challenge of reducing its fossil fuel consumption and emissions. According to the European scenario, it is expected that the passenger transport sector will increase by 40% and freight transport by 60% from 2010 to 2050. Being a sector which plays an important role in the European economy that still relies heavily on fossil fuels, the European Union has set several targets to control CO
2 emissions. For heavy transportation, CO
2 emissions must be reduced up to 30% by 2030, with an interim target of 15% in 2025 [
1].
Combustion engines have numerous constraints that result in the dissipation of fuel energy, jeopardising their efficiency. In HDVs about 34% of the fuel energy is used to move the vehicle, while 30% is lost through exhaust gases, mainly in the form of thermal energy [
2]. It is possible to conclude that instead of the major percentage of thermal losses being dissipated into the environment, it can be used as an energy source.
The thermal energy dissipated by the exhaust system can be reused through waste energy recovery systems, instead of being dissipated into the environment. Amongst the various waste energy conversion systems, those based on TEGs—Thermoelectric Generators—have a strong potential to be used if their current limitations are overcome. In fact, TEGs can convert thermal energy directly into electrical energy by the Seebeck principle. These are highly reliable devices, if carefully projected, have no moving parts, are small, require low maintenance, and can raise fuel efficiency up to 5%. Recent notable examples of this are the analysis, backed by experimental validation performed by Heber et al [
3] which claimed the viability of TEGs in natural gas powered Heavy duty vehicles, with a fuel economy up to 2.8%, powers reaching 3 kW and an estimated amortization period of significantly less than 2 years. TEGs include several connected semiconductors, positively doped (p-type) and negatively doped (n-type), which create thermoelectric junctions, the p-n couples. As a temperature gradient is created across the thermoelectric junctions an electromotive force is induced, enabling, by implementing an electrical load, the flow of electrical current to the vehicle. However, TEGs have limitations regarding the maximum tolerated temperature and the sensitivity of their output to the thermal level. On the one hand, most commercially available TEGs can support only modest temperatures, typically 250 °C. On the other hand, to operate at their maximum efficiency, they need to be as close as possible to their maximum allowable temperature. This makes their optimisation under realistic driving conditions nearly impossible unless some thermal control may be implemented [
4,
5].
Thus, to fully exploit the TEGs efficiency, they should operate at uniform temperature and closest to their temperature limit. The heat exchanger must be capable of maximising the heat absorption as much as possible, independently of the driving cycle, which can have high or low exhaust temperatures, while ensuring that the temperature reaching the modules does not exceed its limit. Besides exploring new promising and affordable thermoelectric materials [
6,
7] The authors have been exploring a clever system to do this in a passive way, with a TCTG concept using either variable conductance thermosiphons (VCTS) [
8,
9,
10,
11,
12] or Heat Pipes (HPs) [
13]. In the former case, the phase change process was used to absorb and transfer all the exhaust heat to the TCTG. In the more recent developments, the phase change process was only used to spread the excess heat from hotter to cooler regions of the generator to overcome the above-mentioned problems through thermal control. This temperature control is achieved through the concept, proposed by the researchers, of heat spreading through a phase change. This consists of using a liquid/vapour phase change system embedded along the heat exchanger which has the role of absorbing the excess heat from overheated regions, keeping them below the maximum allowable temperature, and then spreading and delivering this heat to under-heated regions of the heat exchanger, optimising temperature levels in this region. The phase change temperature is regulated by adjusting the pressure of a non-condensable gas (NCG) that is pre-charged into the system and stabilises the saturation conditions. The heat exchanger prototypes referred in the previous studies incorporated stainless steel corrugated pipes for the exhaust flow within the generator. They would be embedded in a cast-aluminium matrix along with variable conductance heat pipes (VCHPs). The hot faces of the TEGs would be attached to the aluminium block, receiving the exhaust heat with the temperature already downgraded to the optimal level. The cold face of the TEG modules was attached to finned liquid-cooled plates. The VCHPs were responsible for the heat spreading effect explained above. They enabled the control of the temperature of the hot faces of the TEGs, working as capillary-driven heat carriers/spreaders. In the VCHPs, the exhaust heat is absorbed at the evaporator section, generating vapour. This vapour will fill a lower or a higher fraction of the VCHP depending of the incoming thermal load at the exhaust. Vapour then carries the thermal energy to the condensation region where the heat is released to the TEGs by condensation. The condensates then return to the evaporator through the wick structure by the action of capillary pumping. Since the exhaust gas temperature is not constant, and the modules require uniform temperature, there is the need for a uniform phase change temperature inside the HPs irrespective of thermal load. This can only be obtained through variable conductance, which is implemented by filling part of the condenser with a non-condensable gas. This way, the vapour will fill a higher or lower portion depending on the available thermal energy, thus only a part of the condenser will be active and the rest, filled with the non-condensable gas, inactive. In the case of high exhaust temperatures, the heat transfer area in contact with the TEGs will be higher compared with lower exhaust temperature [
13].
Corrugated pipes embedded in aluminium have issues regarding their minimum spacing in the casting process, reducing the compactness factor and consequently the heat transfer effectiveness. Moreover, VCHPs tend to be expensive, made of copper, a poor pressure-resistant material, and prone to corrosion in casting. Thus, an alternative approach to the aforementioned heat exchanger concept is, firstly, to replace the corrugated pipes with wavy fins (Wfs), notable due to their simplicity of manufacture and potential for thermal performance at a reasonably low-pressure drop. Additionally, another good alternative seems to be to replace the VCHPs by variable conductance vapour chambers (VCVCs), which have the same operation as VCHPs, but geometrically more compact, as they are flat, and can directly be machined into the cast aluminium matrix. Additionally, the VCs envisioned display enhanced surfaces which are laser textured to maximise heat transfer performance and provide capillary pumping. These surfaces are currently being developed under a project. This technique, could be more cost-effective, improve compactness of the system, customisation, and phase change performance [
14,
15].
There seems to be a notable potential for applying this system to HDVs since these vehicles will rely upon combustion engines for a longer time than light duty vehicles and additionally have driving cycles with very high average thermal loads. Thus, the present study assesses the potential of such a system. An HVD with a 12 L Diesel engine was simulated in AVL Cruise to extract the exhaust gas temperature and exhaust mass flow rate along the two driving cycles, the WHVC and Long Haul cycle run. Additionally, to observe the influence of the payload weight in the HDV, the simulation runs were performed with different HDV curb weight loads: full with 25 t, half with 12.75 t and empty with 7.5 t in the WHVC and the Long Haul cycle run, one simulation was performed with the truck on its full weight load, 25.5 t.
2. Heat Exchanger Concept
The proposed TCTG represented in
Figure 1 consists of a heat exchanger that absorbs the exhaust heat through WF embedded in cast aluminium. Then, it transfers this heat by conduction across the aluminium to the TEGs that are attached to the aluminium block surface. A part of the heat absorbed by the modules is converted into electricity, while the rest of the heat crosses the TEG modules by conduction and is dissipated to the heat sinks, the CP, attached to the modules cold faces. The system can spread the heat from overheated regions of the heat exchanger to underheated regions avoiding excess temperature and providing heat flux uniformity due to the implementation of VCs. When the temperature is below the maximum, these VCs are inactive and all the heat is transferred by conduction across the heat exchanger. Once the maximum allowable operating temperature is overcome at the upstream regions of the heat exchanger, the working fluid that is contained inside the VCs starts boiling, absorbing the heat and preventing a further temperature rise at the overheated regions. The vapour thus generated condenses and releases the heat at the cooler downstream regions of the heat exchanger providing optimal temperature level to all the regions of the heat exchanger reached by the vapour.
2.1. Wavy Fins
WFs are compact heat exchangers of interest due to their great area density and geometry, which enhances the heat transfer effectiveness. The wavy pattern surface expands not only the length of the airflow path, but also the surface area, increasing the area density. In the system, WFs similar to the ones presented in
Figure 2, produced by BorgWarner, were introduced [
14,
16]. WFs geometrical parameters are important for the system operation and are presented in the following sections.
Figure 2 illustrates the considered geometrical characteristics.
Wavy Fins Empirical Correlations for Thermal Analysis
WFs require empirical correlations to allow the calculation of the heat transfer coefficient (
h). The maximum air velocity in the fin (
) is an important design parameter and is obtained by Equation (
1), where
is the gas volume flow and
the section area of the fin channels. The hydraulic diameter of the fin entrance (
) and the air viscosity
v are also used for Equation (
2).
The heat transfer and pressure drop characteristics for different geometry parameters, such as WF, can be reported in terms of the
j factor and
f, as a function of
, where
is the wavy fin length:
Dong Junqi [
16] performed its analysis on WF by using a general CHE equation for the friction factor (
f), where the constants
and
were graphically obtained according to the geometry parameters, hence the
and
are 0.4 and 0.2 in Equation (
5), where
is the total air side heat transfer surface area.
The surface effectiveness (
) and fin efficiency (
) for the of wavy fins are determined by:
where
is the total finned area of the WF,
the thermal conductivity of the fin material.
2.2. Thermoeletric Modules
The thermoelectric generators considered were fairly standard Bismuth telluride modules and not particularly performing, as the main objective of the study was to assess the TCTG concept and not so much the specific output of the thermoelectric materials used. They were the GM250-127-28-10 from Adaptive Power Management ([
18]). Their maximum operating temperature was 250 °C at the hot face. The geometrical and thermoeletric features are presented in
Table 1.
2.3. Variable Conductance Vapour Chambers
The VCs in the system are part of the ongoing project CoolSpot (see acknowledgements). These VCs act as thermal controllers as they transport the heat excess to areas where the limit temperature is not reached. Since the purpose is to prevent the TEGs from overheating, the boiling temperature of the working fluid must be as close as possible to the maximum temperature of the TEGs’ hot face. To achieve the main thermal control purpose, keep the TEGs hot face closest to its maximum tolerated temperature, and to address the volatile thermal loads present in the exhaust gases, these VCs are pressurised with a non-condensable gas, with an adjusted pre-load pressure for a boiling temperature of the working fluid slightly above the TEGs’ maximum temperature so that the hot face temperature will be close to this maximum, maximising output. With water as a working fluid, this pressure would be around 4 MPa, however, the materials used here would recommend a fluid with saturation pressures at the designed temperature which would be closer to ambient. Such fluid could be the Dowtherm-A, which has a saturation pressure around ambient for 250 °C.
Enhanced Surfaces
Laser textured VCs can be a considerable advantage when compared to common HPs and VCs. The idea is to implement this technique for a better boiling and condensation performance and also to replace the wick, responsible for returning the fluid from the condenser to the evaporator, by a textured surface. This approach has already been introduced in [
19].
On the one hand, an important approach to boiling enhancement is the creation of micro/nanochannels and cavities by laser ablation, triggering the onset of nucleate boiling with lower wall superheat, therefore, bubbles can be formed with lower superheat, avoiding a high bubble growth rate. The ideal size of the nucleation cavities are a function of local wall and bulk fluid temperatures, heat transfer coefficient and heat flux [
20]. Another aspect is the wettability of the surface. For this purpose, hydrophobic surfaces promote larger bubble departure diameters and more coalescence, which reduces the temperature of the onset of nucleate boiling and increases the heat transfer coefficient. On the contrary, hydrophilic surfaces provide smaller bubble departure diameters as the surface “pulls” the liquid towards the nucleation sites, which requires greater superheat for nucleate boiling to occur and do not necessarily provide an enhanced heat transfer coefficient at low heat fluxes [
21]. Despite the fact that hydrophobic surfaces seem to be better at first sight, the capillarity of the texture should also be considered, as it is responsible for the movement of the condensed liquid back to the evaporator [
22].
On the other hand, steam condensation can happen in two distinct ways: dropwise condensation and film condensation. In dropwise condensation, vapour droplets form at an acute angle to a surface, flowing as they tend to coalescence and accumulate static droplets. For film condensation, a thin laminar film of liquid is created covering the surface and tends to increase as the liquid flows and accumulates. The heat transfer coefficient for dropwise condensation can be one order of magnitude higher than that of film condensation ([
23]), making it more desirable. Although for long periods of time it is common that a film would start to occur ([
24]), dropwise condensation is more effective because drops are formed and released, keeping the surface continually exposed instead of creating a thermal resistance barrier that would cover the surface–film condensation. For a practical appliance, one of the necessary conditions for dropwise condensation would be the creation of a hydrophobic contact, so that liquid droplets would tend to compact, instead of spreading and accumulating in a film [
25,
26,
27]. One of the methods to create metallic hydrophobic surfaces is by laser ablation, with or without chemical treatment.
Another important aspect of this improvement is capillarity, which is behind the movement of the working fluid from the condenser to the evaporator. Capillarity action is caused by the minimisation of the surface energy, in other words, the smaller the contact angle of the fluid with the surface the higher the capillarity. Consequently, hydrophilic surfaces or paths are desirable, so the fluid can spread and move along its way [
28].
Concluding, in order to achieve better condensation and evaporation, the surface must have the biggest contact angle possible with the fluid (hydrophobic), but, in an opposite way, the movement of the fluid as it condenses and returns to the evaporator must have the smallest contact angle possible. As is evident, there is a conflict in the idealisation of the wettability of the surface. In order to overcome this problem, a biphilic surface is being idealised, where the main pattern is hydrophobic and there are hydrophilic paths. This can be achieved with multimaterial surfaces, that are being tested by the authors via laser ablation and laser sintering, through Nd-YAG 04 and LM-DVO 100 laser machines, respectively, with some sample results having been presented in [
19]. These considerations do not affect the present modelling, as the phase change phenomena is treated in a simplified way, with the vapour region of the VCs being considered isothermal and the NCG region being treated as adiabatic.
2.4. Cooling Plates
The CP design used is based on the CPs manufactured by the authors from commercially available heat sinks obtained by the extrusion process, to which a cover has been welded. These CPs have a high fin density, which minimises their thermal resistance, and a large flow cross-section to minimise pressure drop. This is not the focus of the present analysis and other lighter, more compact designs could have been chosen for the simulation. Indeed, it is expected that an industrial prototype will be much lighter and compact. However, this geometry was used to allow future experimental validation of the simulations. The CPs have a typical working operation, water flows through the channels ensuring the cold face of the TEGs stays as cool as possible. The CP channels implemented a Fischer Elektronik SK624 ([
29]) profile inside an aluminium case, which, due to its thickness, allows the uniform temperature of the TEGs cold face.
4. System Simulations
4.1. Heat Flux
The TEG model implements discretizations along the flow direction and across the heat exchanger layers. Both these discretizations are one-dimensional in nature and connected through energy balances. However, the three-dimensional effects were taken into account by obtaining the 1D equivalent thermal resistances of the 3D shapes and then incorporating these thermal resistances into the heat transfer analysis. These simulations were performed for fixed heat sources and heat sink conditions, but the thermal resistances extracted from the analysis are universal, as they mainly depend on geometric parameters. This analysis was executed through a two-dimensional steady-state thermal analysis in COMSOL Multiphysics. The CAD model of the system, the respective component materials and their thermal properties, and convective properties, such as the heat transfer coefficient of the WFs, were applied to the simulation. Two distinct heat transfer modes are possible for each heat exchanger section: VCs are treated as isothermal cavities, when phase change is present, and VCs are treated as adiabatic cavities when only NCG is present and no vapour. Thus, two different simulations were performed. In these simulations, data from cycle points regarding the exhaust gas were implemented. For the isothermal VCs (active, phase change region), a cycle point where the module body would exceed the limit temperature of 250 °C without the aid of phase change. For the adiabatic VCs (inactive, NCG region), a cycle point in which the modules would not exceed the limit temperature was selected.
4.2. 1D Model
To predict the behaviour of the concept, an algorithm accounts for the thermal and electrical properties of the several components, taking into consideration the status of the VCs in each discretized section and providing the fundamental results for the optimisation of the system. For the heat exchanger analysis, both the TEGs hot face (TTEGh) and cold face (TTEGc) must be calculated for each cycle point. Since the main objective of the present study was to assess the performance of the thermal control strategy rather than to assess and optimise specific TEG materials or geometries, the approach taken to model the thermoelectric modules was simplified. Regarding the electrical load resistances, matched load conditions were considered. The prediction of the behaviour of the TEGs, namely the power output and their effective thermal resistance was fitted from datasheet information for matched load conditions. This way, the heat flux already accounts for the average effect of the Peltier heat pumping. The power prediction was computed from polynomial regression of the power curves interpolated for the actual hot side and cold side temperatures obtained from the heat transfer calculations.
Regarding the power electronics to be implemented in a real prototype a maximum power point tracking (MPPT) system should be implemented along with a voltage buck/boost strategy to allow the supply of the electricity with a voltage level compatible with the system. It is expected that the thermal control will be beneficial for temperature matching among TEG rows. Given the sequential activation of the several rows of the system according to the thermal input, a modular architecture is probably better suited than a centralised one.
The heat exchanger is divided into several longitudinal slices in which the heat transfer calculations are performed in 1D. Energy balances are performed to each section and a calculation of vaporisation or condensation power is also performed if the VCs happens to be active. In the first iteration of a slice, it is considered that there is no excess heat and that the VCs are not operating (no phase change). Under these conditions, the thermal resistances with adiabatic VCs are applied. Then, on that slice, there is the need to discover if there is there is heat excess or not. If the heat transfer calculations confirm that indeed there is no excess temperature (TTEGh < 250 °C), the VCs are indeed not operating and the thermal resistances with adiabatic VCs have been correctly applied. Otherwise, if the calculations confirm that there is an excess temperature (TTEGh > 250 °C), the VCs are in reality operating and absorbing heat so that TTEGh does not exceed the operating temperature limit. Therefore, the calculation must be repeated, now using the thermal resistances considering isothermal VCs. Under these conditions, a computation of the heat accumulated by the VCs in the form of vapour is performed. Additionally, there is a third possibility, in which the calculations confirm that the temperature would be below the temperature limit without the VCs being active, but the accumulated excess power that has been calculated from the sections located upstream (which represents vapour generated and accumulated) has still not been absorbed by the subsequent slices. This would mean that the slice is located in a condensation region of the VCs. Here, the calculations are redone, but now using the isothermal VCs condition and calculating the heat that has been absorbed by the VCs. Once all accumulated excess heat has been absorbed by subsequent sections and depleted, then all downstream sections will operate without phase change, and a TTEGh lower than the limit of the materials.
The algorithm not only provides a prediction of the electrical load produced by the modules and how many TEG lines are fully active during the cycle run, but also the power absorbed by the heat exchanger and by the TEGs and the pumping power necessary to overcome the TCTG by the exhaust gas.
6. Conclusions
The goal of the present study was to evaluate a typical long haul commercial heavy-duty vehicle (HDV) equipped with the thermoelectric exhaust heat recovery system with thermal control proposed by the authors. The purpose of the system is to maximise the absorption of the heat normally lost through the exhaust gases and convert it into electricity using thermoelectric generators operating at an optimised temperature level irrespective of engine load. A previously proposed custom thermoelectric and heat transfer modelling was run based on AVL Cruise driving cycle analysis results under the WHVC and long haul driving cycles, and adapted to a new geometry consisting of wavy fin heat exchanger and Variable Conductance Vapour Chambers (VCs). This latter component was used to implement the absorption and spreading of excess heat from overheated regions to under-heated regions of the heat exchanger with an optimised temperature through liquid/vapour phase change.
The accomplished project results of the developed TEG system regarding the electricity production, fuel savings and corresponding CO2 emission savings seem overall promising, especially when compared with existing results in literature for thermoelectric generators. Average electric power productions of 1.63 kW, 1.3 kW, 1.24 kW were achieved for the WHVC Full, Half and Empty, respectively, and 2.4 kW for the Long Haul cycle run. The maximum electrical powers were similar in the four cases since the same modules were used: 4.98 kW, 4.77 kW, 4.62 kW for WHVC Full, Half and Empty, respectively, and 4.63 kW for the Long Haul cycle run, meaning that at these points of the cycle the TEGs were operating at their optimal working temperature, 250 °C. Average fuel consumption savings of about 2% and CO2 emissions savings of around 37 g/km were predicted in most simulations. It is possible to conclude that the system has a good potential for waste recovery applications in HDVs with minimum maintenance requirements, especially when submitted to long vehicle use. This very positive performance of the system is attributed to the ability of the system to maximise heat absorption, while still keeping the modules close to their optimal temperature while preventing them from overheating or from excessive thermal dilution.