Next Article in Journal
Photon Counting CT Angiography of the Head and Neck: Image Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions
Next Article in Special Issue
Impact of Staining Methods and Human Factors on Accuracy of Manual Reticulocyte Enumeration
Previous Article in Journal
Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial Fibrillation Detection by Photoplethysmography
Previous Article in Special Issue
Impact of Anti-Endothelial Cell Antibodies (AECAs) in Patients with Polycythemia Vera and Thrombosis
 
 
Review
Peer-Review Record

Digital Droplet PCR in Hematologic Malignancies: A New Useful Molecular Tool

Diagnostics 2022, 12(6), 1305; https://doi.org/10.3390/diagnostics12061305
by Sara Galimberti 1, Serena Balducci 1, Francesca Guerrini 1, Marzia Del Re 1 and Rossella Cacciola 2,*
Reviewer 1:
Reviewer 2: Anonymous
Diagnostics 2022, 12(6), 1305; https://doi.org/10.3390/diagnostics12061305
Submission received: 1 May 2022 / Revised: 21 May 2022 / Accepted: 22 May 2022 / Published: 24 May 2022
(This article belongs to the Special Issue Diagnosis for Hematologic Disorders)

Round 1

Reviewer 1 Report

I think this article is very well written and exhaustive. 

I would suggest to add this other reference when mentioning IgH 

Fluorescent polymerase chain reaction and capillary electrophoresis for IgH rearrangement and minimal residual disease evaluation in multiple myeloma.

Novella E, F.Haematologica. 2002 Nov;87(11):1157-64.

Otherwise, please accept it in its current format

Author Response

Revised Manuscript Diagnostics-1730730

Review Article “Digital Droplet PCR In Hematology: A New Useful Molecular Tool”

 

point-by-point summary of responses

 

Author’s Reply to the Review Report (Reviewer 1)

 

1)I would suggest to add this other reference when mentioning IgH

Novella E. Haematologica 2002;Nov.87(11):1157-64

 

P10 – L31

 

The reference “Novella E, Giaretta I, Felice F, Madeo D, Piccin A, Castaman G,

Rodeghiero F. Fluorescent polymerase chain reaction and capillary

electrophoresis for IgH rearrangement and minimal residual disease evaluation

in multiple myeloma. Haematologica 2002;87(11):1157-1164” was added in the text and list.

The number of added reference is [97].

 

Reviewer 2 Report

I suggest that a more appropriate title will be Digital droplet PCR in hematologic malignancies.A new useful molecular tool

Otherwise the paper is very well organised and documented

Author Response

Revised Manuscript Diagnostics-1730730

Review Article “Digital Droplet PCR In Hematology: A New Useful Molecular Tool”

 

point-by-point summary of responses

 

Author’s Reply to the Review Report (Reviewer 2)

 

1)I suggest that a more appropriate title will be Digital droplet PCR in hematologic malignancies. A new useful molecular tool

 

The title was modified according to suggestion of Reviewer as follows:

 

“Digital Droplet PCR in Hematologic Malignancies. A New Useful Molecular Tool”

 