Effects of Simultaneous Liquid or Gel Sodium Hypochlorite Irrigation on the Cyclic Fatigue of Two Single-File Nickel-Titanium Instruments
Abstract
:Featured Application
Abstract
1. Introduction
2. Materials and Methods
2.1. Study Design
2.2. Cyclic Fatigue Testing
2.3. Statistical Analysis
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Conflicts of Interest
References
- Thompson, S.A. An overview of nickel-titanium alloys used in dentistry. Int. Endod. J. 2000, 33, 297–310. [Google Scholar] [CrossRef] [Green Version]
- Cheung, G.S.; Peng, B.; Bian, Z.; Shen, Y.; Darvell, B.W. Defects in ProTaper S1 instruments after clinical use: Fractographic examination. Int. Endod. J. 2005, 38, 802–809. [Google Scholar] [CrossRef] [PubMed]
- Shen, Y.; Cheung, G.S.; Bian, Z.; Peng, B. Comparison of defects in ProFile and ProTaper systems after clinical use. J. Endod. 2006, 32, 61–65. [Google Scholar] [CrossRef] [PubMed]
- Capar, I.D.; Ertas, H.; Ok, E.; Arslan, H.; Ertas, E.T. Comparative study of different novel nickel–titanium rotary systems for root canal preparation in severely curved root canals. J. Endod. 2014, 40, 852–856. [Google Scholar] [CrossRef] [PubMed]
- Shen, Y.; Zhou, H.-M.; Zheng, Y.-F.; Campbell, L.; Peng, B.; Haapasalo, M. Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments. J. Endod. 2011, 37, 1566–1571. [Google Scholar] [CrossRef] [PubMed]
- Staffoli, S.; Grande, N.M.; Plotino, G.; Özyürek, T.; Gündoğar, M.; Fortunato, L.; Polimeni, A. Influence of environmental temperature, heat-treatment and design on the cyclic fatigue resistance of three generations of a single-file nickel-titanium rotary instrument. Odontology 2019, 107, 301–307. [Google Scholar] [CrossRef]
- Alfawaz, H.; Alqedairi, A.; Alsharekh, H.; Almuzaini, E.; Alzahrani, S.; Jamleh, A. Effects of sodium hypochlorite concentration and temperature on the cyclic fatigue resistance of heat-treated nickel-titanium rotary instruments. J. Endod. 2018, 44, 1563–1566. [Google Scholar] [CrossRef]
- Grande, N.M.; Plotino, G.; Silla, E.; Pedullà, E.; DeDeus, G.; Gambarini, G.; Somma, F. Environmental temperature drastically affects flexural fatigue resistance of nickel-titanium rotary files. J. Endod. 2017, 43, 1157–1160. [Google Scholar] [CrossRef]
- De Vasconcelos, R.A.; Murphy, S.; Carvalho, C.A.T.; Govindjee, R.G.; Govindjee, S.; Peters, O.A. Evidence for reduced fatigue resistance of contemporary rotary instruments exposed to body temperature. J. Endod. 2016, 42, 782–787. [Google Scholar] [CrossRef] [Green Version]
- Berutti, E.; Chiandussi, G.; Paolino, D.S.; Scotti, N.; Cantatore, G.; Castellucci, A.; Pasqualini, D. Canal shaping with WaveOne Primary reciprocating files and ProTaper system: A comparative study. J. Endod. 2012, 38, 505–509. [Google Scholar] [CrossRef] [Green Version]
- Bürklein, S.; Hinschitza, K.; Dammaschke, T.; Schäfer, E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int. Endod. J. 2012, 45, 449–461. [Google Scholar] [CrossRef] [PubMed]
- Serafin, M.; De Biasi, M.; Franco, V.; Angerame, D. In vitro comparison of cyclic fatigue resistance of two rotary single-file endodontic systems: OneCurve versus OneShape. Odontology 2019, 107, 196–201. [Google Scholar] [CrossRef] [PubMed]
- Christofzik, D.; Bartols, A.; Faheem, M.K.; Schroeter, D.; Groessner-Schreiber, B.; Doerfer, C.E. Shaping ability of four root canal instrumentation systems in simulated 3D-printed root canal models. PLoS ONE 2018, 13, e0201129. [Google Scholar] [CrossRef] [PubMed]
- Huang, X.; Shen, Y.; Wei, X.; Haapasalo, M. Fatigue resistance of nickel-titanium instruments exposed to high-concentration hypochlorite. J. Endod. 2017, 43, 1847–1851. [Google Scholar] [CrossRef]
- Ruddle, C. Cleaning and shaping the root canal system. In Pathways of the Pulp, 8th ed.; Cohen, S., Burns, R.C., Eds.; Mosby: St Louis, MO, USA, 2002; pp. 231–292. [Google Scholar]
- Peters, O.A.; Boessler, C.; Zehnder, M. Effect of liquid and paste-type lubricants on torque values during simulated rotary root canal instrumentation. Int. Endod. J. 2005, 38, 223–229. [Google Scholar] [CrossRef]
- Pedullà, E.; Grande, N.M.; Plotino, G.; Pappalardo, A.; Rapisarda, E. Cyclic fatigue resistance of three different nickel-titanium instruments after immersion in sodium hypochlorite. J. Endod. 2011, 37, 1139–1142. [Google Scholar] [CrossRef]
- PPH CERKAMED. Chloraxid 5.25%. 2018. Available online: https://cerkamed.com/product/chloraxid-525/ (accessed on 1 September 2020).
- PPH CERKAMED. Chloraxid 5.25% GEL. 2018. Available online: https://cerkamed.com/product/chloraxid-525-gel/ (accessed on 1 September 2020).
- Pedullà, E.; La Rosa, G.R.M.; Virgillito, C.; Rapisarda, E.; Kim, H.C.; Generali, L. Cyclic fatigue resistance of nickel-titanium rotary instruments according to the angle of file access and radius of root canal. J. Endod. 2020, 46, 431–436. [Google Scholar] [CrossRef]
- Schneider, S.W. A comparison of canal preparations in straight and curved root canals. Oral Surg. Oral Med. Oral Pathol. 1971, 32, 271–275. [Google Scholar] [CrossRef]
- Moreno, D.; Conde, A.J.; Loroño, G.; Adorno, C.G.; Estevez, R.; Cisneros, R. Comparison of the volume of root canal irrigant collected by 2 negative pressure needles at different flow rates of delivery. J. Endod. 2018, 44, 838–841. [Google Scholar] [CrossRef]
- Boutsioukis, C.; Lambrianidis, T.; Kastrinakis, E.; Bekiaroglou, P. Measurement of pressure and flow rates during irrigation of a root canal ex vivo with three endodontic needles. Int. Endod. J. 2007, 40, 504–513. [Google Scholar] [CrossRef]
- International ASM. ASM Handbook, Fatigue and Fracture; ASM International: Novelty, OH, USA, 1996; Volume 19. [Google Scholar]
- Basniev, K.S.; Dmitriev, N.M.; Chilingar, C.V. Mechanics of Fluid Flow; Scrivener Publishing LLC: Austin, TX, USA, 2012. [Google Scholar]
- Sakka, S. Viscosity and spinnability of gelling solutions. In Handbook of Sol-Gel Science and Technology; Klein, L., Aparicio, M., Jitianu, A., Eds.; Springer: Cham, Switzerland, 2016. [Google Scholar]
- Elnaghy, A.M.; Elsaka, S.E. Cyclic fatigue resistance of One Curve, 2Shape, ProFileVortex, Vortex Blue, and RaCe nickel-titanium rotary instruments in single and double curvature canals. J. Endod. 2018, 44, 1725–1730. [Google Scholar] [CrossRef] [PubMed]
- Kaval, M.E.; Capar, I.D.; Ertas, H.; Sen, B.H. Comparative evaluation of cyclic fatigue resistance of four different nickel-titanium rotary files with different cross-sectional designs and alloy properties. Clin. Oral Investig. 2017, 21, 1527–1530. [Google Scholar] [CrossRef]
- Pereira, E.S.; Peixoto, I.F.; Viana, A.C.; Oliveira, I.I.; Gonzalez, B.M.; Buono, V.T.; Bahia, M.G. Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments. Int. Endod. J. 2012, 45, 469–474. [Google Scholar] [CrossRef] [PubMed]
- Yoneyama, T.; Kobayashi, C. Endodontic instruments for root canal treatment using Ti–Ni shape memory alloys. In Shape Memory Alloys for Biomedical Applications; Woodhead Publishing Limited: Cambridge, UK, 2009; pp. 297–305. [Google Scholar]
- Ertuğrul, İ.F. Effect of sodium hypochlorite on the cyclic fatigue resistance: A scanning electron microscopy evaluation. Microsc. Res. Tech. 2019, 82, 2089–2094. [Google Scholar] [CrossRef]
- Topçuoğlu, H.S.; Topçuoğlu, G.; Kafdağ, Ö.; Balkaya, H. Effect of two different temperatures on resistance to cyclic fatigue of One Curve, EdgeFile, HyFlex CM and ProTaper next files. Aust. Endod. J. 2020, 46, 68–72. [Google Scholar] [CrossRef]
- Micoogullari Kurt, S.; Kaval, M.E.; Serefoglu, B.; Kandemir Demirci, G.; Çalışkan, M.K. Cyclic fatigue resistance and energy dispersive X-ray spectroscopy analysis of novel heat-treated nickel-titanium instruments at body temperature. Microsc. Res. Tech. 2020, 83, 790–794. [Google Scholar] [CrossRef]
- Shen, Y.; Qian, W.; Abtin, H.; Gao, Y.; Haapasalo, M. Effect of environment on fatigue failure of controlled memory wire nickel-titanium rotary instruments. J. Endod. 2012, 38, 376–380. [Google Scholar] [CrossRef] [PubMed]
- Pedullà, E.; Benites, A.; La Rosa, G.M.; Plotino, G.; Grande, N.M.; Rapisarda, E.; Generali, L. Cyclic fatigue resistance of heat-treated nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization. J. Endod. 2018, 44, 648–653. [Google Scholar] [CrossRef]
- Cheung, G.S.; Darvell, B.W. Low-cycle fatigue of rotary NiTi endodontic instruments in hypochlorite solution. Dent. Mater. 2008, 24, 753–759. [Google Scholar] [CrossRef]
- Praisarnti, C.; Chang, J.W.; Cheung, G.S. Electropolishing enhances the resistance of nickel-titanium rotary files to corrosion-fatigue failure in hypochlorite. J. Endod. 2010, 36, 1354–1357. [Google Scholar] [CrossRef]
- Piconi, C.; Maccauro, G. Zirconia as a ceramic biomaterial. Biomaterials 1999, 20, 1–25. [Google Scholar] [CrossRef]
- Shen, Y.; Huang, X.; Wang, Z.; Wei, X.; Haapasalo, M. Low Environmental Temperature Influences the Fatigue Resistance of Nickel-titanium Files. J. Endod. 2018, 44, 626–629. [Google Scholar] [CrossRef]
- Plotino, G.; Grande, N.M.; Cordaro, M.; Testarelli, L.; Gambarini, G. A review of cyclic fatigue testing of nickel-titanium rotary instruments. J. Endod. 2009, 35, 1469–1476. [Google Scholar] [CrossRef] [PubMed]
- Hülsmann, M.; Donnermeyer, D.; Schäfer, E. A critical appraisal of studies on cyclic fatigue resistance of engine-driven endodontic instruments. Int. Endod. J. 2019, 52, 1427–1445. [Google Scholar] [CrossRef] [PubMed] [Green Version]
Instrument | ||||
---|---|---|---|---|
Type of Irrigation | F6 SkyTaper | One Curve | ||
20 °C ± 1 °C | 37 °C ± 1 °C | 20 °C ± 1 °C | 37 °C ± 1 °C | |
Without NaOCl | 120 a1 ± 15 | 90 b1 ± 14 | 180 c1 ± 14 | 146 d1 ± 18 |
Liquid NaOCl 5.25% | 186 a2 ± 18 | 98 b1 ± 11 | 279 c2 ± 20 | 225 d2 ± 21 |
Gel NaOCl 5.25% | 147 a3 ± 13 | 92 b1 ± 11 | 269 c2 ± 16 | 215 d2 ± 17 |
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Pedullà, E.; La Rosa, G.R.M.; Albani, M.S.; Isola, G.; Özyürek, T.; Generali, L. Effects of Simultaneous Liquid or Gel Sodium Hypochlorite Irrigation on the Cyclic Fatigue of Two Single-File Nickel-Titanium Instruments. Appl. Sci. 2020, 10, 6666. https://doi.org/10.3390/app10196666
Pedullà E, La Rosa GRM, Albani MS, Isola G, Özyürek T, Generali L. Effects of Simultaneous Liquid or Gel Sodium Hypochlorite Irrigation on the Cyclic Fatigue of Two Single-File Nickel-Titanium Instruments. Applied Sciences. 2020; 10(19):6666. https://doi.org/10.3390/app10196666
Chicago/Turabian StylePedullà, Eugenio, Giusy Rita Maria La Rosa, Marco Sesto Albani, Gaetano Isola, Taha Özyürek, and Luigi Generali. 2020. "Effects of Simultaneous Liquid or Gel Sodium Hypochlorite Irrigation on the Cyclic Fatigue of Two Single-File Nickel-Titanium Instruments" Applied Sciences 10, no. 19: 6666. https://doi.org/10.3390/app10196666