Next Article in Journal
Assessment of Optimum CaO Content Range for High Volume FA Based Concrete Considering Durability Properties
Next Article in Special Issue
Elastography—A Bona Fide Non-Invasive Method for Assessing Non-Alcoholic Fatty Liver Disease in Children
Previous Article in Journal
Learn and Tell: Learning Priors for Image Caption Generation
Previous Article in Special Issue
Thyroid Multimodal Ultrasound Evaluation—Impact on Presurgical Diagnosis of Intermediate Cytology Cases
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Diagnostic Value of Different Risk-Stratification Algorithms in Solid Breast Lesions

1
Internal Medicine 2nd Department, Victor Babes University of Medicine and Pharmacy Timisoara, 2nd Eftimie Murgu Square, 300041 Timisoara, Romania
2
Obstetrics and Gynecology Department, Victor Babes University of Medicine and Pharmacy Timisoara, 2nd Eftimie Murgu Square, 300041 Timisoara, Romania
3
Analytical Chemistry Department, Victor Babes University of Medicine and Pharmacy Timisoara, 2nd Eftimie Murgu Square, 300041 Timisoara, Romania
4
Toxicology Department, Victor Babes” University of Medicine and Pharmacy Timisoara, 2nd Eftimie Murgu Square, 300041 Timisoara, Romania
5
Functional Science Department, Victor Babes University of Medicine and Pharmacy Timisoara, 2nd Eftimie Murgu Square, 300041 Timisoara, Romania
*
Authors to whom correspondence should be addressed.
Appl. Sci. 2020, 10(19), 6943; https://doi.org/10.3390/app10196943
Submission received: 18 July 2020 / Revised: 29 September 2020 / Accepted: 2 October 2020 / Published: 4 October 2020
(This article belongs to the Special Issue Elastography and Applications)

Abstract

:
In the past few years, elastography has gained ground as a complementary method to ultrasonography in noninvasive breast cancer screening. Despite positive outcomes, there is a further need to refine the method, especially regarding BIRADS scores 3 and 4A, where the distinction between benignancy and malignancy is established. The aim of the present study was to evaluate the best risk-stratification system using both qualitative and semiquantitative elastographic methods for solid breast nodules. A total of 1405 solid nodules, described in 657 female patients, were examined in our endocrine unit between January 2018 and December 2019. The inclusion criterion for our retrospective study was the presence of any solid breast mass in women of all ages (mean, 40.85 ± SD 27.11), detected during ultrasound examination using a HITACHI PREIRUS machine (Hitachi Medical Corporation, Tokyo, Japan). The Breast Imaging Reporting and Data System (BIRADS)–US criteria were used in the assessment of each nodule by conventional US (gray-scale mode) and Doppler evaluation. The Ueno score and strain ratio were also measured for all the described lesions. We considered multiple algorithms for the risk reassessment of solid breast nodules: classical BIRADS–US, EFSUMB BIRADS, worst-case scenario BIRADS and BIRADS TM. There were 93 malignant nodules out of 1405. The diagnosis was based on histopathological results for all the malignant lesions. Benign lesions were diagnosed based on histopathological results, Tru-Cut biopsy, mammography and MRI. The Sensitivity (Se), Specificity (Sp), Positive Predictive Value (PPV), Negative Predictive Value (NPV) and Accuracy (Acc) were obtained for all the proposed risk-stratification reporting systems: conventional BIRADS-US (Se, 74.23%; Sp, 63.95%; PPV, 13.53%; NPV, 97.79%; Acc, 65%); EFSUMB BIRADS (Se, 71.23%; Sp, 81.55%; PPV, 22.68%; NPV, 97.99%; Acc, 81%); worst-case scenario BIRADS (Se, 84.23%; Sp, 58.23%; PPV, 13.29%; NPV, 98.84%; Acc, 60%); BIRADS TM (Se, 81.23%; Sp, 75.84%; PPV, 20.35%; NPV, 98.81%; Acc, 77%). We found that the most efficient risk-stratification reporting system was the proposed one, BIRADS TM, which considers both upgrading and downgrading the conventional BIRADS-US, followed by the worst-case scenario BIRADS and EFSUMB BIRADS.

1. Introduction

Breast cancer among women, although one of the most common cancers, can have a good prognosis if detected and treated promptly [1]. For these reasons, it is necessary to continuously improve and adjust diagnostic methods in order to increase patient receptivity. Attention must be focused on improving noninvasive diagnostic methods in order to minimize unnecessary surgery.
Mammography screening was proven to detect cancer at an early stage with an estimated relative reduction of mortality of 15% in women aged 50 and over [2]. Although effective, mammography has its limitations [3]. Several factors such as dense breasts and patient age under 40 limit its applicability [4,5,6].
Breast ultrasonography as a complementary diagnostic method allows circumventing the age and breast density limitations of mammography, as well as being able to differentiate solid from cystic lesions and evaluate palpable breast lesions not visible on mammography and being suitable for pregnant patients [7,8,9,10].
Subsequently, by introducing high-frequency transducers, ultrasonography allows the differentiation of malignant from benign breast masses [8,11,12], leading to it being a candidate for a first-choice diagnostic method in breast cancer screening [13]. As a simple, noninvasive, nonirradiating and painless technique, it can be easily performed routinely in order to solve the patient addressability issue.
Real-time elastography is a recent imaging technique used complementarily to conventional US, resulting in increased diagnostic accuracy [8,14,15].
Sonoelastography screening for breast cancer is a valuable diagnostic tool, leading to a decrease in unnecessary biopsies [16,17]. Recent studies show a 9.4% unnecessary biopsy rate if breast sonoelastography is implemented as the screening method [16]. Despite this, breast cancer screening through ultrasonography can still be improved to reduce the number of unneeded biopsies [18,19,20], which is required in order to avoid causing the patients additional discomfort and emotional distress [21,22].
The American College of Radiology (ACR) developed a common and reproducible way of breast ultrasound interpretation. Breast lesions are evaluated based on well-defined criteria including the shape, boundary, echo pattern, orientation, margin and posterior acoustic features and classified into BIRADS (Breast Imaging Reporting and Data System) categories 1 to 5 [23].
Current recommendations by the EFSUMB and WFUMB guidelines are to downgrade the BIRADS scores 4A and below in cases with low stiffness but not in cases with a BIRADS score of 4B or higher [24].
One contribution of our study was the introduction of two new risk-stratification reporting systems (BIRADS TM and BIRADS worst case) combining both qualitative and semiquantitative elastography methods with conventional breast ultrasound, allowing both downgrading and upgrading the conventional BIRADS US score, a novel approach not yet identified in the current literature.
Another contribution with regards to the current available literature on the subject was the evaluation of a significantly higher number of solid breast nodules. Comparable studies have analyzed breast nodule sample sizes ranging from 99 to 200 [18,19,25]. We analyzed 1405 solid nodules, of which 93 were later confirmed to be malignant.
The current study is a retrospective study, evaluating the best risk-stratification reporting system using any combination of conventional US, doppler evaluation and strain elastography (both qualitative and semiquantitative techniques) through multiple algorithms for the risk reassessment of solid breast nodules in order to identify the optimal threshold for malignancy.

2. Materials and Methods

2.1. Solid Breast Lesions

The retrospective study included 1405 solid nodules examined in our endocrine unit between January 2018 and December 2019.
The inclusion criterion for our study was the presence of any solid breast mass in women of all ages, detected during ultrasound examination.
The exclusion criteria were previous breast surgery for malignant lesions, radiation therapy, a completely cystic lesion and subcutaneous lipomas.
The standard criterion for the presence or absence of breast cancer was a pathologic result from fine-needle cytology, core-needle biopsy, excision biopsy or a combination of mammography and breast MRI.
The study was performed in accordance with the ethical guidelines of the Helsinki Declaration and was approved by the Ethics Committee of our Center. Written informed consent was obtained from all patients in order to use the pathology results and ultrasound images for a post hoc analysis.

2.2. Equipment and Diagnostic Techniques

2.2.1. Classical Ultrasound

Bilateral High-Resolution B-mode grey scale ultrasonography was performed on all cases, using a HITACHI PREIRUS machine (Hitachi Medical Corporation, Tokyo, Japan) with Doppler and elastography software. A special breast probe, EUP-L53L, 920 mm wide, with a water bag device, was used for gray-scale evaluation, with the patient resting in the supine position and both hands bent under the head, and ductal breast evaluation was performed according to Amy’s technique [26]. The aforementioned is a radial technique, examining the breast with the nipple positioned in the left upper corner and the peripheral lobar structure in the right part of the screen, visualizing all recommended layers on the screen starting from the skin (upper layer) to the rib structures and pleura (lower layers).
A complete US evaluation was performed for each solid lesion individually including conventional gray-scale, color Doppler scanning and strain elastography performed in the same session.
The US evaluation results include measurements (the largest diameter), the composition (only solid lesions), the shape (taller-than-wide or not), margins (regular/anfractuous/spiculate), the homogeneity (homogenous or inhomogeneous), the echogenicity (hyper-, iso- or hypoechoic/marked hypoechoic), the presence of calcifications (present or absent), the vascularity (absent/perilesional/intralesional), the posterior acoustic shadowing (absent/mild/accentuated) and the presence of suspicious lymph nodes (normal/inflammatory/edemic with eccentric hilum).
The malignancy criteria according to the American College of Radiology [27] were considered as follows: marked hypoechogenic lesion; inhomogeneity; ill-defined borders; “taller than wide” shape; spiculate, poly-lobular or rough margins; posterior acoustic shadowing; intralesional microcalcifications; tortuous internal vascularity; proliferative infiltration of the afferent duct; and altered lymph nodes: round, with no evidence of hilum, eccentric hilum or cortical edema, with a cortical width bigger than 3 mm.
The Breast Imaging Reporting and Data System (BIRADS)–US criteria [24] were used in the evaluation of each nodule in conventional US-mode gray-scale and Doppler evaluation, resulting in a BIRADS score for each nodule.

2.2.2. Elastography

Real-time elastography was performed after the conventional ultrasound evaluation, in the same examination session, using a HITACHI PREIRUS machine (Hitachi Medical Corporation, Tokyo, Japan) equipped with real-time elastography software, using a 5–18 MHz linear multifrequency probe positioned perpendicular to the skin during compression.
The qualitative SE (standard blue–red–green color map) was determined for each nodule. A Ueno score of 1 to 5 was assigned for each nodule based on the color balance of green and blue inside the tumor and the surrounding area. At least two measurements were performed for each solid nodule, in radial and anti-radial sections. All ultrasounds were performed by the same operator prior to any surgery, biopsy or fine-needle aspiration.
The semiquantitative technique used was the Fat-to-Lesion Ratio (FLR) automatically computed by the machine. After placing the Region of Interest (ROI) around the entire solid lesion, the machine automatically generates a second ROI placed in the surrounding pre-glandular subcutaneous fat, resulting in a stiffness ratio called the FLR score being attributed to each nodule. A FLR ratio higher than 4.5 was considered indicative of malignancy [19].
Multiple previous studies described excellent diagnostic quality for elastography, when used alone (Se, 100 %; Sp, 73.8%; Acc, 80%) and when used in conjunction with conventional US evaluation (Se, 88.5%; Sp, 78.6%; Acc, 80.9%) [14]. Other studies show comparable results with sensitivity ranging between 88% and 93% and specificity ranging between 83% and 95.7%, with an accuracy of 93.9 [18,24,28,29,30,31].
Both qualitative evaluation (color code Tsukuba diagnostic performance: Se, 86.5%; Sp, 89.8%; and Acc, 88.3%) [32] and the semiquantitative procedure (FLR, Fat–Lesion Ratio, diagnostic performance: Se, 88%; Sp, 83%; and Acc, 85%) have noteworthy diagnostic value in discriminating benign from malignant lesions [33,34,35].

2.3. Risk Stratification

Risk stratification was quantified using the following BIRADS scores for each nodule: the BIRADS US, defined according to ACR guidelines; BIRADS EFSUMB, according to EFSUMB guidelines; and the two new proposed risk-stratification reporting systems BIRADS TM and BIRADS worst case.
The BIRADS US score, based solely on ultrasound evaluation results, was calculated separately per nodule on a five-point grading scale, increasing with the likelihood of malignancy. Furthermore, a BIRADS score of 4 can be divided into 4A, 4B or 4C if 1, 2 or more than 3 malignancy US markers were observed. For each nodule, we assigned the appropriate BIRADS score as follows: 1 indicates a normal result; 2, a benign lesion; 3, a solid hypoechoic lesion without any US malignancy marker; 4, a lesion with one or more US malignancy markers; 5, a malignant lesion; 0, an indeterminate result.
For qualitative elastography, we defined the following risk categories—low risk: Ueno 1 or 2; intermediate risk: Ueno 3; and high risk: Ueno 4 and 5—and for semiquantitative elastography, low risk: FLR <2.8; intermediate risk: FLR between 2.8 and 4.5; and high risk: FLR >=4.5.
We defined and integrated the BIRADS EFSUMB score (US-ELASTO BIRADS) [19], where stiffness was considered an extra risk factor according to the current recommendations of the EFSUMB guidelines [36]. The conventional downgrade of low stiffness was performed for BIRADS 4A and below, with cases 4B, 4C and 5 not downgraded.
Our proposed algorithm “BIRADS TM” reassessed classical ultrasound BIRADS scores, both upgrading and downgrading based on elastographic results. The scores were upgraded irrespective of the initial result if high stiffness was found, but only scores equal to or lower than 4B were downgraded in the case of low stiffness.
Finally, a “worst-case scenario” (BIRADS worst case) was also analyzed, considering the highest risk category defined by any of the previous evaluations, allowing only a risk upgrade strategy and no downgrade regardless of any additional information.

2.4. Statistical Analysis

Microsoft Excel was used for experimental data handling, and all solid nodules were centralized in a table. For each diagnosis criterion, the sensitivity, specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) and accuracy were calculated; afterwards, the Receiver Operating Curve (ROC) was drawn for each of the used diagnosis criteria in order to visualize the differences in diagnostic value. Lastly, the Area Under the Receiver Operating Curve (AU) was computed as a differentiating performance index for all the considered risk-stratification reporting systems.

3. Results

This retrospective study included 1405 solid nodules described in 657 female patients, aged between 16 and 78 years old (mean age, 40.85 ± SD 27.11), examined in our Endocrine Unit between January 2018 and December 2019. Of the 1405 nodules, 93 were found to be malignant (three cases of Carcinomas in Situ—CIS), detected in 63 patients, aged between 16 and 78 (mean age, 47 ± SD 13.61). The following anamnestic data were also documented but were not considered in the risk-stratification analysis. Only the sonoelastographic parameters were considered. For the patients with malignancies, they were as follows: the body mass index (BMI) (mean, 25 ± SD 4.40; median, 25), menarche (mean, 14 ± SD 1.20; median, 14), climax age (mean, 47 ± SD 5.00; median, 49), number of births (mean, 1 ± SD 0.80; median, 1); breastfeeding (mean, 9 months ± SD 9.48; median, 5), the use of oral contraceptives (17 out of 63 patients, with mean, 3 years ± SD 3.63; median, 2); breast cancer heredity (9 out of 63 patients), and smokers (23 out of 63 patients). None of them had ovarian cancer, and 2 out of 63 underwent irradiation therapy for other malignancies.
The addressability for US evaluation was the result of routine screening, breast tenderness, the palpation of a breast lump, skin changes, nipple retraction, nipple discharge or previous breast trauma.
The malignancy results for the 1405 solid nodules assessed by histopathological results, Tru-Cut biopsy, mammography or MRI are shown in the Table 1 below.

3.1. Conventional Gray-Scale US

In order to define the BIRADS-US score for each nodule, the ultrasound malignancy markers according to the ACR [27] were analyzed. The results can be seen in the following table (Table 2), where for each malignancy marker, the total number of occurrences is stated. Next, the absolute and relative values for malignancy, as checked against later investigations by histopathological results or a combination of mammography and MRI, were obtained.
The diagnostic power was computed for each conventional US characteristic for identifying breast cancer. The analysis results are embodied by the following measures of diagnostic accuracy—Sensitivity (Se), Specificity (Sp), Positive Predictive Value (PPV), Negative Predictive Value (NPV) and Accuracy (ACC)—all expressed as percentages (Table 3). Although not explicitly used later in our study, the diagnostic power of the considered malignancy markers is relevant, as the BIRADS-US score assessment is based on their occurrence as described by the WFUMB guidelines [24].
Based on the malignancy marker occurrence shown in Table 2 and the WFUMB guidelines [24], for each nodule, a BIRADS score was attributed. In the following table (Table 4), the total number of occurrences for each of the four considered BIRADS possible scores is stated. Of the possible BIRADS scores of one through five, BIRADS scores of one and two were attributed to normal breast and cystic lesions and were excluded from the study. After the assessment, the results were checked against later investigations by histopathological results or a combination of mammography and MRI. The numbers of malignant and benign confirmed nodules are shown for each BIRADS score.

3.2. Elastography Results

Following qualitative real-time elastography, each nodule was automatically given a Ueno score of one through five. Ueno 1 scores were only found in cystic lesions, which were excluded from the study. In the following table (Table 5), the total occurrence for each Ueno score is shown as well as the number of malignant and benign nodules as confirmed by later investigations with histopathological results or a combination of mammography and MRI.
Lastly, semiquantitative real-time elastography was performed, and Fat-to-Lesion Ratio (FLR) values were automatically given for each nodule. The FLR values were split into three groups by likelihood of malignancy, as described earlier in Section 2.2 and can be seen in the following table (Table 6). Additionally, the total occurrence per group is shown alongside malignant and benign occurrences as confirmed by later investigations using histopathological results or a combination of mammography and MRI.

3.3. Diagnostic Value of All Analyzed Methods

After attributing all nodules a BIRADS score according to each proposed risk-stratification system described in Section 2.3 (BIRADS US, EFSUMB BIRADS, BIRADS TM and worst-case scenario BIRADS), the diagnostic power was computed for each risk-stratification system alongside the ones for purely elastographic scores. The following measures of diagnostic accuracy are shown (Table 7): Sensitivity (Se), Specificity (Sp), Positive Predictive Value (PPV), Negative Predictive Value (NPV) and Accuracy (ACC), all expressed as percentages.

3.4. Receiver Operating Characteristic Curve

In order to graphically show the diagnostic value of each proposed risk-stratification system and remove the influence of the cut-off values, a Receiver Operating Characteristic Curve (ROC curve) was drawn for each proposal. In the following figure (Figure 1), all the ROC curves are plotted alongside the ROC curve for a “chance” diagnostic.
After plotting the ROC curves, the area under each curve was calculated using the trapezoidal rule. The resulting areas with values between 0.5 for chance and 1 for a theoretically perfect differentiating method are shown in the following table (Table 8). This allows for a quick, one-parameter comparison between the diagnostic powers of the different proposed risk-stratification systems.

4. Discussion

The main goal of the present study was to evaluate the best risk-stratification reporting system for sonoelastographic breast examination, in order to improve its diagnostic value, considering multiple algorithms of risk reassessment for 1405 solid breast nodules.
The best outcomes for ultrasonography in the evaluation of solid breast nodules was proven to be the addition of elastography [14,20,34,37]. It has been previously shown that elastography can improve the accuracy of classical ultrasonography by up to 26% [14].
There is still the need for improvement, especially in the BIRADS categories 3 and 4A, in order to properly differentiate malignant from benign lesions. BIRADS 4A lesions may be the group where elastography should play a decisive role when deciding between immediate biopsy and only regular follow-up [18,38,39].
In our study, both semiquantitative and qualitative methods proved to be significantly accurate (Acc, 94%) as can be seen in Table 7, with Se values of 79.56% and 55.15%, respectively, and Sp values of 95.20% and 95.56%; the results are found to be comparable to other studies where Se = 88%, Sp = 83% and Acc = 85% for the fat-to-lesion ratio, and Se = 86.5%, Sp = 89.8% and Acc = 88.3% for the elastography score values are described [14,18].
The optimal FLR value from the data set (obtained by maximizing the sensitivity to false-positive differences) was 4.34 and can be seen in the following table (Table 9). This is comparable with the threshold of 4.88 from a previous study carried out in our endocrine unit [19]. Other studies found optimal FLR values from 2.24 to 5.6 [24,25,31,39].
Although the initially considered threshold of FLR >= 4.5 is different from the resulting optimal value from the dataset, the diagnostic metrics shown in the table above are nearly identical. Both can be used with the same degree of confidence.
Our study showed (Table 7) that the sensitivity, specificity and accuracy of classical ultrasound for the diagnosis of malignant lesions, using a BIRADS cut-off value of 4A, were 74.23%, 63.95% and 65%, respectively, and its positive and negative predictive values were 13.53% and 97.79%, respectively. Due to the low PPV, it cannot be used alone to rule out malignancy given the probability of false-negative results. As can be seen in Table 4, there were 19 malignancies out of 93 in BIRADS category 3 when assessing only by classical US alone.
The BIRADS score downgraded according to EFSUMB proved to have better diagnostic quality compared to classical BIRADS, showing a 71.23% sensitivity, an 81.55% specificity and an accuracy of 81%. The PPV and NPV were 22.68% and 97.99%, respectively. While there was no significant difference in sensitivity after combining conventional US with elastography, the accuracy increased by 16% and the PPV was increased by 9.15%.
The newly proposed risk-reassessment BIRADS TM showed an 81.23% sensitivity, 75.84% specificity, 77% accuracy, 20.35% PPV and 98.81% NPV. It has similar diagnostic value to EFSUMB BIRADS but with a 10% higher sensitivity. It appears that considering both upgrading and downgrading the conventional BIRADS is more advisable than downgrading alone.
We also considered the worst-case scenario BIRADS score. The sensitivity, specificity and accuracy values for this assumption were 84.23%, 58.23% and 60%, respectively, while the PPV and NPV values were 13.29% and 98.84%, giving this assumption the best sensitivity but the poorest PPV of all the considered risk-stratification reporting systems.
The “worst-case scenario” is the most conservative approach, with the highest sensitivity but also with the lowest specificity. Using this approach may lead to an increase in false-positive malignancy results and subsequent biopsy recommendations, which would be against the goal of this study with regards to lowering unnecessary biopsy rates.
The Receiver Operating Curve was used to evaluate the diagnostic value for each of the proposed diagnostic methods. Furthermore, the area under the ROC curves was calculated for use as a one-dimensional measure of diagnostic value.
The ROC curves of the fat-to-lesion ratios and Ueno elastography scores showed much better AUC values of 0.90 and 0.88, respectively (a theoretically perfect diagnostic having AUC = 1), than the curve for classical ultrasound BIRADS (0.77). Other studies also showed that the values are slightly better for FLR in comparison with Ueno scores (0.85 and 0.79, respectively) [15].
For the different risk-reassessment algorithms, the AUC values were 0.80 for EFSUMB BIRADS and 0.83 for worst-case scenario BIRADS, and the proposed BIRADS TM showed the best result of 0.86 (as can be seen in Table 8).
In our study, elastography improved the AUC value of breast cancer ultrasound screening, starting from 0.77 for classical ultrasound and improving to 0.86 when adjusting the classical ultrasonography BIRADS score by upgrading or downgrading based on both qualitative and semiquantitative elastographic results (“BIRADS TM”).

5. Conclusions

By including elastography as a parameter of the BIRADS score and considering both upgrading and downgrading the conventional BIRADS as opposed to only downgrading according to EFSUMB recommendations, a more efficient risk-stratification reporting system was established in the form of BIRADS TM. The proposed BIRADS TM risk-stratification system, while having slightly lower accuracy compared to BIRADS EFSUMB, yields better diagnostic value, as shown by higher AUROC values. Further development and standardization of the method may improve the evaluation of high-risk nodules.
The second proposed risk-stratification reporting system in the form of the worst-case BIRADS shows the lowest accuracy, specificity and positive predictive values but, on the other hand, yields the highest sensitivity and negative predictive values of all the analyzed risk-stratification methods. This shows it is the most conservative approach, leading to the highest number of assumed malignant lesions and, in turn, to an increase in biopsy rates, which would be against our goal of reducing unnecessary invasive diagnostic method usage. For these reasons, we do not consider it advisable.
The strong points of the study are the evaluation of a significant number of solid breast nodules and the assessment of multiple risk-stratification reporting systems combining classical ultrasound and elastography (both qualitative and semiquantitative methods), two being novel proposals and one (BIRADS TM) being shown to yield potentially better diagnostic value than the current EFSUMB recommendations.
The limitations of the study are represented by the lack of histopathological results for all the evaluated nodules (only 93 of the malignancies were found as a result of histopathological investigations). The other nodules were diagnosed based on a combination of mammography, breast MRI and Tru-Cut biopsy.

Author Contributions

Conceptualization, D.S. and I.E.; methodology, D.S. and I.E.; software, F.B.; statistics, I.M.; validation, C.A.D. and D.S.; formal analysis, I.E. and D.S.; investigation, I.E. and D.S.; resources, D.S.; data curation, F.B; writing—original draft preparation, I.E.; writing—review and editing, D.S. and V.I.; visualization, D.S. and I.E.; supervision, D.S.; project administration, I.E. and D.S.; surgical intervention, C.D., M.C. and D.N. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. World Health Organization. Breast Cancer. Available online: https://www.who.int/cancer/prevention/diagnosis-screening/breast-cancer/en/ (accessed on 24 June 2020).
  2. Gartlehner, G.; Thaler, K.; Chapman, A.; Kaminski-Hartenthaler, A.; Berzaczy, D.; Van Noord, M.G.; Helbich, T.H. Mammography in combination with breast ultrasonography versus mammography for breast cancer screening in women at average risk. Cochrane Database Syst. Rev. 2013, 4, 3. [Google Scholar] [CrossRef]
  3. Sood, R.; Rositch, A.F.; Shakoor, D.; Ambinder, E.; Pool, K.L.; Pollack, E.; Harvey, S.C. Ultrasound for breast cancer detection globally: A systematic review and meta-analysis. J. Glob. Oncol. 2019, 5, 1–17. [Google Scholar] [CrossRef]
  4. Leconte, I.; Feger, C.; Galant, C.; Berlière, M.; Berg, B.V.; D’Hoore, W.; Maldague, B. Mammography and subsequent whole-breast sonography of nonpalpable breast cancers: The importance of radiologic breast density. Am. J. Roentgenol. 2003, 180, 1675–1679. [Google Scholar] [CrossRef] [Green Version]
  5. Health Quality Ontario: Nikitovic-Jokic, M.; Tu, H.A.; Palimaka, S.; Higgins, C.; Holubowich, C. Ultrasound as an adjunct to mammography for breast cancer screening: A health technology assessment. Ont. Health Technol. Assess. Ser. 2016, 16, 1–71. [Google Scholar]
  6. Benson, S.R.C.; Blue, J.; Judd, K.; Harman, J.E. Ultrasound is now better than mammography for the detection of invasive breast cancer. Am. J. Surg. 2004, 188, 381–385. [Google Scholar] [CrossRef] [PubMed]
  7. Athanasiou, A.; Tardivon, A.; Ollivier, L.; Thibault, F.; El Khoury, C.; Neuenschwander, S. How to optimize breast ultrasound. Eur. J. Radiol. 2009, 69, 6–13. [Google Scholar] [CrossRef] [PubMed]
  8. Tozaki, M.; Isomoto, I.; Kojima, Y.; Kubota, K.; Kuroki, Y.; Ohnuki, K.; Mukai, H. The Japanese breast cancer society clinical practice guideline for screening and imaging diagnosis of breast cancer. Breast Cancer 2015, 22, 28–36. [Google Scholar] [CrossRef] [PubMed]
  9. Ohuchi, N.; Suzuki, A.; Sobue, T.; Kawai, M.; Yamamoto, S.; Zheng, Y.F.; Endo, T. Sensitivity and specificity of mammography and adjunctive ultrasonography to screen for breast cancer in the Japan strategic anti-cancer randomized trial (J-START): A randomised controlled trial. Lancet 2016, 387, 341–348. [Google Scholar] [CrossRef]
  10. Nothacker, M.; Duda, V.; Hahn, M.; Warm, M.; Degenhardt, F.; Madjar, H.; Albert, U.S. Early detection of breast cancer: Benefits and risks of supplemental breast ultrasound in asymptomatic women with mammographically dense breast tissue. A systematic review. BMC Cancer 2009, 9, 335. [Google Scholar] [CrossRef] [Green Version]
  11. Yagtu, M.; Turan, E.; Turan, C.O. The role of ultrasographic elastography in the differential diagnosis of breast masses and its contribution to classical ultrasonographic evaluation. J. Breast Health 2014, 10, 141–146. [Google Scholar] [CrossRef] [Green Version]
  12. Rjosk-Dendorfer, D.; Gürtler, V.M.; Sommer, W.H.; Reiser, M.; Clevert, D.A. Value of highresolution compression elastography and color doppler sonography in characterisation of breast lesions: Comparison of different high-frequency transducers. Clin. Hemorheol. Microcirc. 2014, 57, 129–135. [Google Scholar] [CrossRef] [PubMed]
  13. Pan, H.-B. The role of breast ultrasound in early cancer detection. J. Med. Ultrasound 2016, 24, 138–141. [Google Scholar] [CrossRef]
  14. Leong, L.C.H.; Sim, L.S.J.; Lee, Y.S.; Ng, F.C.; Wan, C.M.; Fook-Chong, S.M.C.; Tan, P.H. A prospective study to compare the diagnostic performance of breast elastography versus conventional breast ultrasound. Clin. Radiol. 2010, 65, 887–894. [Google Scholar] [CrossRef] [PubMed]
  15. Yoon, J.H.; Kim, M.H.; Kim, E.K.; Moon, H.J.; Kwak, J.Y.; Kim, M.J. Interobserver variability of ultrasound elastography: How it affects the diagnosis of breast lesions. Am. J. Roentgenol. 2011, 196, 730–736. [Google Scholar] [CrossRef]
  16. Geiger-Gritsch, S.; Daniaux, M.; Buchberger, W.; Knapp, R.; Oberaigner, W. Performance of 4 years of population-based mammography screening for breast cancer combined with ultrasound in Tyrol/Austria. Wiener Klinische Wochenschrift. 2018, 130, 92–99. [Google Scholar] [CrossRef]
  17. Buchberger, W.; Niehoff, A.; Obrist, P.; DeKoekkoek-Doll, P.; Dünser, M. Clinically and mammographically occult breast lesions: Detection and classification with high-resolution sonography. In Seminars in Ultrasound, CT and MRI; WB Saunders: Philadelphia, PA, USA, 2000; pp. 325–336. [Google Scholar]
  18. Raza, S.; Odulate, A.; Ong, E.M.; Chikarmane, S.; Harston, C.W. Using real-time tissue elastography for breast lesion evaluation: Our initial experience. J. Ultrasound Med. 2010, 29, 551–563. [Google Scholar] [CrossRef] [Green Version]
  19. Stoian, D.; Timar, B.; Craina, M.; Bernad, E.; Petre, I.; Craciunescu, M. Qualitative strain elastography—Strain ratio evaluation—An important tool in breast cancer diagnostic. Med. Ultrason. 2016, 18, 195–200. [Google Scholar] [CrossRef] [Green Version]
  20. Gheonea, I.A.; Stoica, Z.; Bondari, S. Differential diagnosis of breast lesions using ultrasound elastography. Indian J. Radiol. Imaging 2011, 21, 301. [Google Scholar]
  21. Merry, G.M.; Mendelson, E.B. Update on screening breast ultrasonography. Radiol. Clin. North Am. 2014, 52, 527. [Google Scholar] [CrossRef]
  22. Meyer, J.E.; Smith, D.N.; Lester, S.C.; Kaelin, C.; DiPiro, P.J.; Denison, C.M.; Christian, R.L.; Harvey, S.C.; Selland, D.-L.G.; Durfee, S.M. Large-core needle biopsy of nonpalpable breast lesions. Jama 1999, 281, 1638–1641. [Google Scholar] [CrossRef]
  23. D’Orsi, C.J.; Sickles, E.A.; Mendelson, E.B.; Morris, E.A. American College of Radiology. Breast Imaging Reporting and Data System Atlas (BI-RADS Atlas); American College of Radiology: Reston, VA, USA, 2013. [Google Scholar]
  24. Barr, R.G.; Nakashima, K.; Amy, D.; Cosgrove, D.; Farrokh, A.; Schafer, F.; Dietrich, C.F. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 2: Breast. Ultrasound Med. Biol. 2015, 41, 1148–1160. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  25. Cho, N.; Moon, W.K.; Kim, H.Y.; Chang, J.M.; Park, S.H.; Lyou, C.Y. Sonoelastographic strain index for differentiation of benign and malignant nonpalpable breast masses. J. Ultrasound Med. 2010, 29, 1–7. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  26. Amy, D.; Durante, E.; Tot, T. The lobar approach to breast ultrasound imaging and surgery. J. Med. Ultrason. 2015, 42, 331–339. [Google Scholar] [CrossRef] [PubMed]
  27. D’Orsi, C.J.; Sickles, E.A.; Mendelson, E.B.; Morris, E.A.; et al. Mammography, ultrasound, magnetic resonance imaging, follow-up and outcome monitoring. In ACR BI-RADS Atlas: Breast Imaging Reporting and Data System; Data Dictionary; American College of Radiology: Reston, VA, USA, 2013. [Google Scholar]
  28. Taylor, K.; O’Keeffe, S.; Britton, P.D.; Wallis, M.G.; Treece, G.M.; Housden, J.; Sinnatamby, R. Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study. Clin. Radiol. 2011, 66, 1064–1071. [Google Scholar] [CrossRef] [Green Version]
  29. Zhu, Q.L.; Jiang, Y.X.; Liu, J.B.; Liu, H.; Sun, Q.; Dai, Q.; Chen, X. Real-time ultrasound elastography: Its potential role in assessment of breast lesions. Ultrasound Med. Biol. 2008, 34, 1232–1238. [Google Scholar] [CrossRef]
  30. Sadigh, G.; Carlos, R.C.; Neal, C.H.; Dwamena, B.A. Accuracy of quantitative ultrasound elastography for differentiation of malignant and benign breast abnormalities: A meta-analysis. Breast Cancer Res. Treat. 2012, 134, 923–931. [Google Scholar] [CrossRef]
  31. Goddi, A.; Bonardi, M.; Alessi, S. Breast elastography: A literature review. J. Ultrasound 2012, 15, 192–198. [Google Scholar] [CrossRef] [Green Version]
  32. Itoh, A.; Ueno, E.; Tohno, E.; Kamma, H.; Takahashi, H.; Shiina, T.; Matsumura, T. Breast disease: Clinical application of US elastography for diagnosis. Radiology 2006, 239, 341–350. [Google Scholar] [CrossRef]
  33. Sigrist, R.M.; Liau, J.; El Kaffas, A.; Chammas, M.C.; Willmann, J.K. Ultrasound elastography: Review of techniques and clinical applications. Theranostics 2017, 7, 1303. [Google Scholar] [CrossRef]
  34. Alhabshi, S.M.I.; Rahmat, K.; Halim, N.A.; Aziz, S.; Radhika, S.; Gan, G.C.; Latar, N.H.M. Semi-quantitative and qualitative assessment of breast ultrasound elastography in differentiating between malignant and benign lesions. Ultrasound Med. Biol. 2013, 39, 568–578. [Google Scholar] [CrossRef]
  35. Mutala, T.M.; Ndaiga, P.; Aywak, A. Comparison of qualitative and semiquantitative strain elastography in breast lesions for diagnostic accuracy. Cancer Imaging 2016, 16, 1–7. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  36. Bamber, J.; Cosgrove, D.; Dietrich, C.F.; Fromageau, J.; Bojunga, J.; Calliada, F.; Fink, M. EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 1: Basic principles and technology. Eur. J. Ultrasound 2013, 34, 169–184. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  37. Stoian, D.; Craciunescu, M.; Anastasiu, D.M.; Dumitru, C.; Craina, M.; Ionac, M. Classic ductal sonographic criteria versus real time elastography criteria in diagnosing nodular breast lesions. J. Endocrinol. 2014, 2, 17. [Google Scholar]
  38. Ricci, P.; Maggini, E.; Mancuso, E.; Lodise, P.; Cantisani, V.; Catalano, C. Clinical application of breast elastography: State of the art. Eur. J. Radiol. 2014, 83, 429–437. [Google Scholar] [CrossRef]
  39. Ikeda, K.; Ogawa, Y.; Takii, M.; Sugano, K.; Ikeya, T.; Tokunaga, S.; Ikehara, T. A role for elastography in the diagnosis of breast lesions by measuring the maximum fat lesion ratio (max-FLR) by tissue Doppler imaging. Breast Cancer 2012, 19, 71–76. [Google Scholar] [CrossRef]
Figure 1. Receiver operating characteristic curves for proposed diagnostic methods.
Figure 1. Receiver operating characteristic curves for proposed diagnostic methods.
Applsci 10 06943 g001
Table 1. Malignancy results for the considered nodules.
Table 1. Malignancy results for the considered nodules.
Absolute ValueRelative Value [%]
Benign124188.33
Cancer906.4
CIS30.21
Fibrocystic Mastosis40.28
Adenosis674.77
Total1405100
Table 2. Conventional breast ultrasound malignancy markers and malignancy (1405 nodules).
Table 2. Conventional breast ultrasound malignancy markers and malignancy (1405 nodules).
TotalBenignMalignant
AbsoluteRelative [%]AbsoluteRelative [%]
Intense hypoechogenic16314085.882314.12
Inhomogeneous25721382.884417.12
Ill-defined borders946872.342627.66
“Taller than wide”392871.791128.21
Spiculate and anfractuous margins704970.002130.00
Posterior acoustic shadowing13969.23430.77
Intralesional microcalcifications392051.281948.72
Tortuous internal vascularity29524583.055016.95
Altered lymph nodes with no evidence of hilum, eccentric hilum or cortical edema251456.001144.00
Table 3. Conventional breast ultrasound malignancy markers—diagnostic power (1405 nodules)
Table 3. Conventional breast ultrasound malignancy markers—diagnostic power (1405 nodules)
Se [%]Sp [%]PPV [%]NPV [%]ACC [%]
Inhomogeneous47.3183.7717.1295.730.81
Calcifications20.4398.4848.7294.580.93
Intense hypoechogenic24.7389.3314.1194.360.85
Ill-defined borders27.9694.8227.6694.890.90
Spiculate and anfractuous margins6.4599.5450.0093.750.93
Taller than wide11.8397.8728.2194.000.92
Tortuous internal vascularity53.7681.1716.9596.120.97
Posterior acoustic shadowing4.3098.9330.7793.580.93
Altered lymph nodes with no evidence of hilum, eccentric hilum or cortical edema11.8398.9344.0094.060.94
Table 4. Conventional breast ultrasound Breast Imaging Reporting and Data System (BIRADS) scores and malignancies (1405 nodules).
Table 4. Conventional breast ultrasound Breast Imaging Reporting and Data System (BIRADS) scores and malignancies (1405 nodules).
BenignMalignantTotal
BIRADS 383919858
BIRADS 446450514
BIRADS 5122133
Table 5. Qualitative real-time elastography scores and malignancies (1405 nodules).
Table 5. Qualitative real-time elastography scores and malignancies (1405 nodules).
BenignMalignantTotal
Ueno 23099318
Ueno 318922211
Ueno 45448102
Ueno 5156
Table 6. Semiquantitative real-time elastography scores and malignancies (1405 nodules).
Table 6. Semiquantitative real-time elastography scores and malignancies (1405 nodules).
BenignMalignantTotal
FLR < 2.888910899
FLR 2.8–4.536011371
FLR > 4.56669135
Table 7. Diagnostic value of proposed methods (1405 nodules).
Table 7. Diagnostic value of proposed methods (1405 nodules).
Se [%]Sp [%]PPV [%]NPV [%]ACC [%]
BIRADS US74.2363.9513.5397.7965
Semiquantitative RTE (FLR)79.5795.2051.3998.3594
Qualitative RTE (UENO)55.1595.9650.9397.0794
EFSUMB BIRADS71.2381.5522.6897.9981
BIRADS TM81.2375.8420.3598.8177
Worst-case scenario BIRADS84.2358.2313.2998.8460
Table 8. Area under the Receiver Operating Characteristic (ROC) curve for each diagnostic method.
Table 8. Area under the Receiver Operating Characteristic (ROC) curve for each diagnostic method.
AU ROC
Ueno score0.883327
FLR0.901603
BIRADS US 2B0.773243
BIRADS EFSUMB0.800632
BIRADS TM0.862293
Worst case Scenario BIRADS0.836948
Table 9. Optimal FLR values—diagnostic power.
Table 9. Optimal FLR values—diagnostic power.
Se [%]Sp [%]PPV [%]NPV [%]ACC [%]
FLR >= 4.579.5795.2051.3998.3594
FLR >= 4.3481.7294.0549.3598.6493

Share and Cite

MDPI and ACS Style

Eremici, I.; Dumitru, C.; Navolan, D.; Craina, M.; Ivan, V.; Borcan, F.; Dehelean, C.A.; Mozos, I.; Stoian, D. Diagnostic Value of Different Risk-Stratification Algorithms in Solid Breast Lesions. Appl. Sci. 2020, 10, 6943. https://doi.org/10.3390/app10196943

AMA Style

Eremici I, Dumitru C, Navolan D, Craina M, Ivan V, Borcan F, Dehelean CA, Mozos I, Stoian D. Diagnostic Value of Different Risk-Stratification Algorithms in Solid Breast Lesions. Applied Sciences. 2020; 10(19):6943. https://doi.org/10.3390/app10196943

Chicago/Turabian Style

Eremici, Ivana, Catalin Dumitru, Dan Navolan, Marius Craina, Viviana Ivan, Florin Borcan, Cristina Adriana Dehelean, Ioana Mozos, and Dana Stoian. 2020. "Diagnostic Value of Different Risk-Stratification Algorithms in Solid Breast Lesions" Applied Sciences 10, no. 19: 6943. https://doi.org/10.3390/app10196943

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop