We present several numerical studies, starting with SDOF systems subjected to some example ground motions. MDOF systems and a large set of ground motions are considered next. The section starts with an example of an optimization problem to gain insight into the properties of STMDs.
3.1. An Optimization Example
An example of the optimization problem is presented here. The properties of buildings A and B are fixed for numerical simulations. Their frequencies are taken as 6.04 and 7.58 rad/s, and the damping ratio is 5% for both. The frequencies are the same as those of the two buildings studied by Abdullah et al. [
28]. The mass of the two buildings are equal, and the mass of the TMD is expressed as a fraction of the mass of building A, i.e.,
. The frequency of the TMD is denoted by
, and the frequency ratio is defined as
. The damping ratio of the TMD, expressed in terms of the mass and frequency of the TMD, is denoted by
. The variables of interest are therefore
and
.
Figure 2 shows the variation of the cost function with the frequency ratio and damping ratio of the TMD. The cost function has two minima, which correspond to two solutions. There is a local minimum near a frequency ratio of 1. This minimum is more prominent for lower damping ratios. The global minima occur at much larger frequency ratios, ranging from about 10 to about 90 for damping ratios from 0.4 to 0.05. It is interesting to note that the amplitudes of the global minima are not very sensitive to damping ratios of the TMD.
It is then interesting to investigate whether the solution that minimizes corresponds to minimum displacements of the two buildings and minimizes the separation distance required to prevent pounding. This distance is the largest negative relative displacement between the two buildings and is hereafter referred to as the pounding distance. To investigate this, we use the north-south component of the El Centro ground motion from the 1940 Imperial Valley Earthquake and simulate the response of the two buildings and STMD with varying frequency and damping ratios.
The results are shown in
Figure 3. The maximum displacement of the two buildings are shown on the top panel. The maximum stroke of the TMD is shown in the bottom left panel. Here, stroke is defined as the relative displacement of the TMD mass from building A. Pounding distance is shown in the bottom right panel. For comparison, the response of uncontrolled buildings is shown with black dashed lines. Another scenario considered is where an optimally tuned (based on Sadek, [
30]) TMD is placed on building A whereas building B is uncontrolled. In this case, the frequency tuning ratio is 0.96 and the damping ratio is 0.22. The results corresponding to this are shown with dashed blue lines. The results show that the local minima, similar to those observed in
Figure 2, occurs in the displacement response of building A when the TMD is tuned to the frequency of the building. However, the combination of
and
that minimizes
does not necessarily minimize the displacement of building A. For example, for
approximately equal to 1, a damping ratio of 10% is required to minimize
, whereas 5% damping ratio minimizes the peak displacement of building A. This can be explained by the larger stroke of the device when the damping ratio is low, as is clearly seen in the bottom right panel of
Figure 3. The optimal solution near
is not effective in controlling the peak response of building B.
It is also interesting to note that the locally optimal solution (
) of the shared TMD is more effective in controlling peak response of building A, and with a much smaller damping ratio than when the TMD is placed only on building A. This indicates that sharing a TMD with an adjacent building can increase its effectiveness without adversely affecting the response of the adjacent building. This, however, comes at a cost of increased stroke of the device, which is due to low damping values of the locally optimal STMD, as is evident from the bottom left panel of
Figure 3. The stroke of the locally optimal STMD is much larger than the stroke of the TMD placed on building A.
As the frequency ratio is increased, the displacement response of both the buildings show a decreasing trend followed by an increasing trend. This trend is also visible in the cost function shown in
Figure 2. If we consider the minima (based on the cost function) at a higher frequency ratio as the global minima, the optimal frequency ratio decreases with increasing damping, and the optimal solutions are more effective than TMD placed on building A alone. However, these optimal solutions correspond to very stiff springs in the TMD. For a damping ratio as large as 40%, the optimal frequency ratio is about 10. With a mass ratio of 3%, the stiffness of the TMD is about 3 times the stiffness of building A. From a practical point of view, it might not feasible to construct a TMD which is so much stiffer than the building it rests on. Such a solution, although not realistic, will be hereafter referred to as a globally optimal solution referring to the cost function.
At the locally optimal solution, the shared TMD reduces the minimum separation distance to some extent. As the frequency ratio and damping ratio are increased, the pounding distance decreases further. With a very stiff TMD and sufficiently high damping ratio, it appears the pounding distance can be reduced to a large extent. While this seems like a plausible mitigation strategy against pounding, it is deficient in both conceptual and practical terms. In practical terms, having a TMD 3 times stiffer than the building itself is not attractive. The conceptual deficiency is that such a stiff device cannot be considered as a TMD. This can be better understood by inspecting the results shown in the bottom left panel of
Figure 3. Irrespective of the damping ratio, as the frequency ratio increases above 1, the stroke of the TMD reduces rapidly, and for a frequency ratio of 10, the device does not move relative to building A. Therefore, the device is not acting like a TMD and any reduction in response is due to the coupling of the two buildings with a viscous damping device. It is also interesting to note that unlike the cost function which increases after the global minima, the pounding distance decreases with increasing frequency ratio.
3.2. Equivalence of STMD and Viscous Coupling of the Two Buildings
Based on the discussion above, it is apparent that a very stiff TMD is equivalent, in terms of structural response reduction, to a viscous dashpot coupling the two buildings. To illustrate this point better, we modify the system shown in
Figure 1 by lumping the TMD mass on building A, and connecting the two buildings by the same viscous dashpot as that used in the STMD. The resulting system has only two degrees of freedom with masses (
ma +
m) and
mb connected by a dashpot
c. The mass (
ma +
m) is connected to the ground by spring and dashpot
ka and
ca, while
mb is connected to the ground by spring and dashpot
kb and
cb. The peak response of this modified system is divided by the peak response of the system with STMD. The ratio of peak displacement of building A is presented, for the El Centro ground motion, as a function of frequency ratio and damping ratio in
Figure 4. When the shared TMD is near resonance with building A, it is more effective than viscous coupling alone. However, as the frequency ratio is increased, the two systems approach each other, and for a frequency ratio greater than about 20, there is no difference between the two systems. This helps us conclude that STMD optimized on the global minima of the cost function is not a tuned mass damper, as the mass is neither tuned to the structure, nor does it play any part in reducing structural response. In this sense, it is illogical to use additional TMD mass and a very stiff spring element, when the same effect can be obtained by just connecting the two buildings with a viscous dashpot.
3.3. Examination with MDOF Systems
Here we examine the results and conclusions obtained for two SDOF buildings with MDOF models of two buildings. The selected buildings are the same as those used by Abdullah et al. [
28]. Building A has a mass of 3.1752 × 10
5 kg, and stiffness of 3.404 × 10
8 N/m on each floor. Building B has a mass of 3.6287 × 10
5 kg and stiffness of 6.127 × 10
8 on each floor. Both buildings have 8 floors with a damping coefficient of 100 Ns/m on each floor. Fundamental frequencies of buildings A and B are 6.04, and 7.58 rad/s, respectively. The mass of the TMD is 54,430 kg. Abdullah et al. [
28] present two cases as optimal solutions. Case 1 corresponds to attaching the TMD mass to building A by a dashpot and building B by a spring. Case 2 corresponds to a spring connection with building A and dashpot connection to building B. Case 2 was found to be more effective and is considered here for further analysis. Abdullah et al. [
28] arrived at this solution by specifying weights equal to 1 for the displacements in the top four floors of building A and 0 for all other displacements and velocities in defining the
matrix
The cost function for this example is presented in
Figure 5. The frequency ratio, for this system, is defined as the frequency of the STMD divided by the fundamental frequency of building A. Like the cost function for SDOF buildings shown in
Figure 2, the cost function of these MDOF buildings sharing a TMD displays two minima for each damping ratio. The first minima, which is larger than the second one, occurs near the resonance of STMD mass with the first mode of building A. The second minimum occurs at a much larger frequency ratio. The optimal stiffness presented by Abdullah et al. (2001) is 1.786 × 10
8 N/m, which is about 50% of the stiffness of each of the floors of building A. Based on this stiffness, the frequency of STMD is 57.28 rad/s, which corresponds to a frequency ratio of 9.48. The optimal damping coefficient reported by Abdullah et al. [
28] is 1.809E6, which, for this frequency ratio corresponds to a damping ratio of 0.29 for the STMD. It is then clear that the optimal solution reported in Abdullah et al. [
28] corresponds to the global minima of the cost function (see purple line in
Figure 4).
Variation of the peak displacements of buildings A and B with frequency ratio and damping ratio is shown in
Figure 6. The solution considered optimal by Abdullah et al. [
28] is indicated in the figure with red dots. The response of building A, to which the STMD mass is connected by a spring, is optimally controlled when the frequency ratio is close to 1, and the damping ratio is low. This solution, however, is not effective in controlling the response of building B. The optimal solution, based on the global minima of
, as denoted by red dots, is effective in controlling pounding as well as reducing the response of both the buildings. However, the solution uses a very stiff spring, and the TMD mass does not move relative to building A.
This can be confirmed from the low stroke of the device as shown in
Figure 6. The STMD mass, in the solution presented by Abdullah et al. [
28] is essentially motionless and does not function as intended. The solution, therefore, is not a tuned mass damper as its frequency is much larger than the frequency of the buildings it is attached to. In fact, it can be verified that the same response reduction can be achieved by coupling the two buildings with a dashpot. If we consider the optimal solution as the one near resonance of STMD with building A, the STMD is not very effective in controlling pounding between the buildings.
3.4. Effectiveness of STMDs
Based on the results and arguments presented above, the stiff solution cannot be considered as a shared TMD. However, we can define a shared TMD in such a way that it is tuned to the frequency of building A, for example. This solution would correspond to the frequency ratio in the vicinity of 1. An optimal STMD in this context would correspond to the one that minimizes the cost function
in the vicinity of resonance with building A. The example presented above shows that this STMD marginally reduces the pounding distance for the El Centro ground motion. To test if this observation can be generalized to different ground motions and quantify the effectiveness in reducing pounding distance, we use several ground motion records for dynamic analysis of the system. The ground motion records are taken from the European Strong Motion Database [
31]. The database contains 462 ground motion records from 110 earthquakes recorded in Europe and the Middle East. The ground motions are obtained from earthquakes with a moment magnitude of 4.2 to 7.6. The range of epicentral distance is 1 to 558 km, and that of peak ground acceleration (PGA) is 0.9% to 91% of acceleration due to gravity. The strong motion duration, defined as the interval covering 5–95% of Arias Intensity is in the range of 1.2 s to 139 s. Response spectra and duration of these ground motions have been presented in Rupakhety and Sigbjörnsson [
32,
33]. More details about this database can be found in Ambraseys et al. [
34].
Optimal parameters of the STMD are estimated by minimizing the cost function using a genetic algorithm. Population size is taken as 50 and the initial population follows uniform distribution in the specified bounds. Elite count is set to 5% of the population. Crossover fraction is set to 0.8 and migration fraction is set to 0.2. The selection criterion is stochastic uniform and mutation are Gaussian. The ‘ga’ function in Matlab™ with default options was used to implement the algorithm. Different scenarios are simulated: (i) both the buildings are uncontrolled; (ii) TMD is used in building A only, the parameters of the TMD are optimized based on Sadek’s (1997) equations; (iii) the STMD is connected with a spring to building A, and a dashpot to building B. These cases are denoted hereafter as UC (uncontrolled), AC (building A controlled), and SC (controlled with STMD), respectively. In all cases, the TMD mass is taken as 1% of the mass of building A.
Peak roof displacement of building A and pounding distance corresponding to the 462 earthquake ground motions are presented in
Figure 7. The response of the uncontrolled and controlled structures are plotted on the abscissa and ordinate, respectively. The diagonal lines in the figure correspond to the equal response of uncontrolled and controlled structures. The results show that the TMDs result in reduction of peak roof displacement of building A in almost all the ground motions. When the displacement of the uncontrolled structure is small, the response reduction obtained by the TMD is not very significant. However, as the ground motions get more demanding, the effectiveness of the TMDs is higher. For the most severe case (that producing the highest response of the uncontrolled structure), the TMD reduces the response by about 50%. However, it is interesting to note that when the TMD is shared with building B, its effectiveness in controlling the response of building A remains almost unchanged for all the ground motions considered in this study. This shows that sharing the TMD with building B does not reduce its effectiveness. The shared TMD is not effective in controlling the response of building B. Neither does it provide any advantage in reducing the pounding distance between the two buildings. The optimal STMD, therefore, does not provide any clear advantage over the TMD installed on building A alone.
The mean (over 462 ground motions) ratios between the pounding distance of the AC controlled and SC controlled structures to that of the uncontrolled structure are 0.79 and 0.76, respectively. Controlling building A alone is, on average, about 3% less effective than using an STMD. The stiffnesses of AC and SC schemes are 8.96 × 105 N/m and 9.68 × 105 N/m, respectively. Their damping coefficients are 4.73 × 104 kg/s and 2.27 × 104 kg/s. This shows that the SC scheme results in similar performance like the AC scheme, but with a much smaller dashpot. This might be, in theory, an advantage of sharing the device. However, there might be practical difficulties in properly connecting the dashpot between the two buildings, and suitability of the scheme needs to be judged on a case by case basis.
To illustrate the effectiveness of AC and SC schemes in reducing the minimum separation distance between the two buildings, reduction ratio, which is defined as minimum separation distance of the controlled building divided by that of the uncontrolled building is shown in
Figure 8. The smaller this ratio, the more effective is the control scheme. Effectiveness is investigated against different ground motion and structural response parameters. Only those ground motions with PGA larger than 0.2 g are used in the figure. Here, g represents acceleration due to gravity. Ground motions weaker than this are not considered as they were found to cause a low risk of pounding.
Figure 8c shows two different clusters of data, one below ~25 s, and the other to its right. The cluster to the right has very few data points, and any apparent trend in this cluster is not reliable. When duration is less than 25 s, the Pearson correlation coefficient between reduction ratio and duration is −0.44 with a p-value of 0.0011, which shows that the correlation is statistically significant, and not by random chance.
Figure 8b shows that the effectiveness of the TMDs is independent of PGA. There seems to be a weak negative correlation between the pounding distance of the uncontrolled structure and the effectiveness of TMD schemes. The Pearson correlation coefficient was found to be −0.17 with a large p-value of 0.21, which means that any apparent trend in the data is statistically insignificant. The same observation can be made in
Figure 8d, which shows that the effectiveness of TMD schemes is independent of spectral displacement at the fundamental period of the uncontrolled structure. In all these cases, there is no significant difference between the SC and AC schemes, which means that sharing the TMD does not seem to provide additional benefit in preventing pounding.
We next compare the effectiveness of the SC scheme to that of the AC scheme for different mass ratios of the TMD. Mass of the TMD is taken as 1%, 2%, and 3% of the total mass of building A. The optimal solutions for these mass ratios were found with frequency ratios of 1.02, 1.04, and 1.04 and damping ratios of 7%, 11%, and 13%. The effectiveness of the devices is quantified by the mean ratios of pounding distance of SC and AC schemes to that of uncontrolled structure, denoted by
and
respectively. A value of this ratio less than 1 means the control systems, on average, reduce pounding distance. These ratios are shown in
Figure 9. As the mass ratio increases, the performance of SC is better than that of AC. However, even for a mass ratio of 3%, which corresponds to 24% of floor mass, the SC scheme is only about 6% better than the AC scheme. We repeated the analysis with different frequencies of the two buildings and arrived at similar results.