Next Article in Journal
Accurate Prediction and Key Feature Recognition of Immunoglobulin
Next Article in Special Issue
Systematically Investigating the Structural Variety of Crystalline and Kaleidoscopic Vortex Lattices by Using Laser Beam Arrays
Previous Article in Journal
Maximum Admissible Slip of Tractor Wheels without Disturbing the Soil Structure
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Passively Q-Switched KTA Cascaded Raman Laser with 234 and 671 cm−1 Shifts

1
College of Mechanical and Electronic Engineering, Fujian Agriculture and Forestry University, Fuzhou 350002, China
2
Wenzhou Key Laboratory of Micro-Nano Optoelectronic Devices, Wenzhou University, Wenzhou 325035, China
3
Crystech Inc., Qingdao 266100, China
*
Author to whom correspondence should be addressed.
Appl. Sci. 2021, 11(15), 6895; https://doi.org/10.3390/app11156895
Submission received: 4 July 2021 / Revised: 18 July 2021 / Accepted: 20 July 2021 / Published: 27 July 2021
(This article belongs to the Special Issue Optoelectronics for Lasers: Latest Advances and Prospects)

Abstract

:
A compact KTA cascaded Raman system driven by a passively Q-switched Nd:YAG/Cr4+:YAG laser at 1064 nm was demonstrated for the first time. The output spectra with different cavity lengths were measured. Two strong lines with similar intensity were achieved with a 9 cm length cavity. One is the first-Stokes at 1146.8 nm with a Raman shift of 671 cm−1, and the other is the Stokes at 1178.2 nm with mixed Raman shifts of 234 cm−1 and 671 cm−1. At the shorter cavity length of 5 cm, the output Stokes lines with high intensity were still at 1146.8 nm and 1178.2 nm, but the intensity of 1178.2 nm was higher than that of 1146.8 nm. The maximum average output power of 540 mW was obtained at the incident pump power of 10.5 W with the pulse repetition frequency of 14.5 kHz and the pulse width around 1.1 ns. This compact passively Q-switched KTA cascaded Raman laser can yield multi-Stokes waves, which enrich laser output spectra and hold potential applications for remote sensing and terahertz generation.

1. Introduction

Owing to its high optical damage threshold, broad transparency range, and high nonlinear coefficient together with the low ionic conductivity, potassium titanyle arsenate (KTA) is considered to be a promising crystal for nonlinear optics applications. For the past few decades, KTA has been extensively used to yield efficient eye-safe laser and mid-infrared laser via optical parametric oscillation [1,2,3,4]. Moreover, KTA has also attracted increasing attention due to its potential application for efficient stimulated Raman laser operation [5,6,7]. As an effective way to generate coherent light with new wavelengths, stimulated Raman scattering (SRS) has merits for preparing simple, compact, and robust laser sources [8,9,10]. Diverse crystals have been adopted for efficient Raman lasers, such as vanadates [11,12,13], tungstates [14,15,16,17], and molybdates [18]. Different from these commonly used Raman crystals, KTA and its isomorphs possess large Raman gain coefficient and small Raman shifts [19,20,21,22], such that it can generate a variety of high order Stokes lasers by cascade SRS.
In 1991, Watson first investigated the KTA Raman spectrum and identified a strong Raman shift of 234 cm−1 [5]. Based on the intracavity pumped KTA using a Nd:YAG/KTA Raman configuration, Liu et al. studied the first and second-Stokes lasers at 1091 nm and 1120 nm, respectively [6,21]. Lan et al. also surveyed the Raman laser of 1091 nm using a passively Q-switched Nd:YAG/KTA configuration, and a 250 mW power was realized with the conversion efficiency of 3.3% [22]. Based on the Nd:YAP/KTA configuration, Huang et al. reported a simultaneous dual-wavelength eye-safe Raman laser [23]. Liu et al. reported the second harmonic generation (SHG) laser converted from the first-Stokes in KTA Raman with the shift of 671 cm−1 [24]. Our group also studied the multi-Stokes waves from cascade Raman conversion based on a KTA crystal [25]. From the main Raman shifts of 671 cm−1 and 234 cm−1 in the KTA crystal, the gains of high order Stokes waves can enrich laser spectral lines which cannot be directly produced from the laser crystal doped with rare earth ions [26]. In addition, via the processes of the SHG and sum frequency generation (SFG), the Stokes waves can produce visible light which has important applications in remote sensing, visual displays, and medical treatments [27,28]. The simultaneous multi-order Stokes waves output has also been reported to be a prospective pumping source for the terahertz (THz) wave generation employing the nonlinear optics method [29].
A solid-state laser based on Cr4+:YAG passively Q-switching has the advantages of compactness and low cost for high pulse repetition frequency pulse laser operation [30,31,32]. Therefore, a passively Q-switched cascaded Raman laser could be a compact and efficient laser system for Stokes laser output. In this work, for the first time, multi-Stokes waves from passively Q-switched KTA cascaded Raman lasers were studied. A Nd:YAG/Cr4+:YAG composite crystal was used as the saturable absorber. Under a pumping power of 10.5 W and pulse repetition frequency of 14.5 kHz (for the setup with a 5 cm length cavity) the largest average output power of 540 mW was realized with a pulse width of about 1.1 ns. The measured spectra show various Stokes lines in the range of 1050~1200 nm, which were converted via the Raman shifts of 234 cm−1 and 671 cm−1, and two strong lines were located at 1146.8 nm and 1178.2 nm.

2. Experimental Setup

KTA is an anisotropic optical crystal of the orthotropic crystal system. According to the polarization-dependent spontaneous Raman scattering spectra of x-axis cut KTA crystals, strong Raman scattering with two main Raman shifts at 234 cm−1 and 671 cm−1 can be realized from the A1 (ZZ) geometry. Therefore, an x-axis cut KTA crystal of 4 × 4 × 20 mm3 dimension was employed as the Raman medium to satisfy the X(ZZ)X Raman configuration, according to Porto notations. The KTA crystal was placed in a compact plane-concave cavity and driven by the passively Q-switched Nd:YAG laser at 1064 nm. Figure 1 shows the diagrammatic sketch of the passively Q-switched KTA cascaded Raman laser experimental setup. The Nd:YAG crystal composited with Cr4+:YAG crystal in order to make the system more compact and easy to dissipate heat, and these two crystals were used to serve as the laser gain medium and the saturable absorber for passively Q-switching, respectively. The Nd:YAG crystal with the size of 3 × 3 × 7 mm3 is 1.0 at.% doped, and the Cr4+:YAG crystal with size of 3 × 3 × 3 mm3 has an initial transmission of about 85%. While the optics was closed set with each other, the total cavity length was about 50 mm.
The pumping source is a fiber-coupled laser diode array operating at 808 nm, which has a fiber core diameter of 200 μm and a numerical aperture of 0.22. The pump beam was re-imaged by two 808 nm anti-reflection (AR) coated achromatic lenses with focal lengths of 50 and 80 mm, obtaining a beam waist of about 320 μm in the Nd:YAG crystal. Both the Nd:YAG/Cr4+:YAG composite crystal and the KTA crystal were wrapped with indium foil and mounted in a thermoelectric-cooled copper block with the temperature kept at about 20 °C throughout the experiments. Both end-faces of the composite crystal and the KTA crystal were AR coated for the fundamental and Stokes wavelengths from 1000 to 1200 nm, and the pump light incident face of the Nd:YAG crystal was AR coated at 808 nm.

3. Results and Discussion

Table 1 lists Stokes wavelengths with contributed Raman shifts. It can be seen that there are many Stokes wavelengths ranging from 1050 to 1200 nm, which were yielded via two Raman shifts of 234 cm−1 and 671 cm−1. The fundamental and Raman laser oscillation shared the identical plane-concave linear cavity constituted by the input mirror (IM) and the output coupler (OC) mirror. The IM was high-transmission (HT, T > 98%) coated at 808 nm and high-reflection (HR, R > 99.9%) coated from 1000 to 1200 nm. The OC mirror with a radius curvature of 100 mm was HR coated for the range of 1050~1130 nm. The transmittance curve of the output coupler is displayed in Figure 2. With the wavelength larger than 1130 nm, the transmittance increased, reaching 1.5% at 1147 nm and 67% at 1182 nm.
The KTA Raman laser output characteristics were optimized by adjusting the pump power and cavity length. The maximum power of the output was achieved under a pump power of 10.5 W. The data of the output power were detected using the thermal sensor power meter (PM310D, Thorlabs INC). Figure 3 exhibits the average output power for two cavity lengths of 5 cm and 9 cm, with respect to the incident pump power. It is shown that the Raman threshold for a 5 cm length cavity was around 3.4 W, and for a 9 cm length cavity it was around 4.9 W. For the two cavity length setups, the average output powers both raised with the increase of incident pump power, provided with the slope efficiency of 7.6% for the 5 cm length cavity and 8.0% for the 9 cm length cavity. A lower Raman threshold for 5 cm length cavity benefited from its low cavity loss with the short and compact laser cavity, and the 5 cm length cavity is more suitable for high output power than the 9 cm length cavity with an increase of pump power. Under an incident pump power of 10.5 W, the obtained maximum output powers were 530 mW for the setup with 5 cm length cavity, and 320 mW for the setup with 9 cm length cavity. The power instability at the maximum output for these two length cavities were better than 5%.
Figure 4 displays the laser spectra with the 5 cm and 9 cm cavity lengths, respectively. The data were measured at the pump power of 10.5 W using a grating monochromator (Omni-λ500 model, ZOLIX, Beijing, China). According to the wavelengths and Raman shifts shown in Table 1, the spectra lines can be identified. For the setup with the 9 cm length cavity, its spectrum contains two strong lines with similar intensity, which are the first-Stokes at 1146.8 nm with the Raman shift of 671 cm−1, and the Stokes at 1178.2 nm with mixed Raman shifts of 234 cm−1 and 671 cm−1. Four low intensity lines were also detected. They are the fundamental wave at 1064 nm, the first, second and third-Stokes at 1092.0, 1120.7, and 1150.4 nm, respectively, with a Raman shift of 234 cm−1. For the setup with 5 cm length cavity, due to the lower loss caused by the shorter cavity length, the low order Stokes were converted to higher order Stokes. The first-Stokes at 1092.0 nm and the second-Stokes at 1120.7 nm became negligible, while the intensity of 1178.2 nm was significantly enhanced, and more obvious third-Stokes (1150.4 nm) and fourth-Stokes (1182.4 nm) waves with Raman shift of 234 cm−1 were also observed. However, the output was still dominated by the Stokes waves at 1178.2 nm and 1146.8 nm. Therefore, different cavity lengths also resulted in the difference of output spectra, which might be mainly attributed to the intensity distribution changing in the cavity.
The pulse width and pulse repetition frequency with different incident pump powers were obtained using the free-space InGaAs photodetector and exhibited on the 500 MHz oscilloscope (DPO3052B model). In view of the fact that the measured multi-Stokes wavelengths were very close to each other, and they cannot be segregated in our investigation, only the whole temporal pulse profiles of the Stokes waves were provided. As shown in Figure 5, with the incident pump power changed from 3.9 W to 10 W, the pulse repetition frequency went up from 2.9 kHz to 14.5 kHz, and the pulse energy rose from 21 μJ to 36 μJ except for a small decline when the incident pump changed from 4.5 W to 5.2 W. The pulse repetition frequency was not as stable when the instability reached about 25%, which might be caused by the competition of multi-Stokes generation.
The measured pulse trains and temporal pulse profiles at the incident pump power of 10.5 W are displayed in Figure 6. The pulse width was around 1.1 ns, and the pulse repetition frequency was 14.5 kHz. A smaller value of pulse width than 1.1 ns might be more accurate, since the critical time resolution of the used 500 MHz oscilloscope was limited. We also measured the pulse width of weak leaked fundamental laser at 1064 nm, and the obtained value was around 11 ns. Therefore, significant pulse shortening was detected for this KTA Raman laser which is similar to the fact that achieved in SrMoO4 Raman laser [33].
The spectra of the weak visible light accompanying with the Stokes wave output have been measured using a fiber optic spectrometer (AvaSpec-3648 model). The measured spectra are shown in Figure 7. It can be seen that the main lines are located at 573.4 nm and 574.3 nm, and the former can be assigned to the SHG of 1146.8 nm, while the latter is from the SFG of 1146.8 nm and 1150.4 nm with the phase matching angle θ of 82~83° in the x-z plane of KTA crystal. These weak visible lights possessed an output power of about a dozen milliwatts, which should be ascribed to the fact that the phase matching directions of SHG and SFG for the Stokes waves in the cavity were close to the x-axis. To our surprise, the SFG light (567 nm) of 1120.7 nm and 1146.8 nm was not observed. As known from the calculation, the SFG matching angle between these two wavelengths is closer to the x-axis of the KTA crystal compared with those for 573.4 nm and 574.3 nm light generation. The absence of 567 nm SFG light could be attributed to the light conversion from 1120.7 nm to 1150.4 nm due to high reflection of the resonant cavity for 1120.7 nm. Therefore, the 567 nm SFG light was negligible in contrast to the lines of 573.4 and 574.3 nm.

4. Conclusions

In summary, a compact passively Q-switched KTA cascaded Raman laser was demonstrated for the first time. A composite crystal of Nd:YAG/Cr4+:YAG was used for passively Q-switched fundamental laser generation at 1064 nm. The obtained multi-Stokes laser wavelengths range from 1090 to 1200 nm. The output spectra with two different cavity lengths were measured. Two strong lines with similar intensity were achieved with a 9 cm length cavity. One is the first-Stokes at 1146.8 nm with Raman shift of 671 cm−1, and the other is the Stokes at 1178.2 nm with mixed Raman shifts of 234 cm−1 and 671 cm−1. For the setup with a shorter length cavity of 5 cm, some conversions from low order Stokes to higher order Stokes occurred due to the lower loss caused by the shorter cavity length, and the output Stokes waves with high intensity were still at 1146.8 nm and 1178.2 nm. However, the intensity of 1178.2 nm was obviously higher than that of 1146.8 nm. Under an incident pump power of 10.5 W, the measured maximum average output power was 540 mW. The measured pulse width was around 1.1 ns, and the pulse repetition frequency was 14.5 kHz. This compact passively Q-switched KTA cascaded Raman laser can yield multi-Stokes waves, which enrich laser output spectra lines and hold potential applications for remote sensing and terahertz generation.

Author Contributions

Conceptualization, Z.X., Y.D., and H.Z.; validation, Z.X. and S.L.; formal analysis, Z.X., S.L., Z.L., Y.Z., and H.Z.; resources, H.W.; writing—original draft preparation, Z.X. and S.L.; writing—review and editing, Y.D., Z.L., L.C., Y.Z. and H.Z.; supervision, Y.D. and H.Z. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Zhejiang Provincial Natural Science Foundation of China under (Grant No. LY19F050012), the National Natural Science Foundation of China under (Grant No. 62075167 and No. 61905180), the public welfare projects of Wenzhou city under (Grant No. G2020013 and No. S20180015), and the Natural Science Foundation of Fujian Province (Grant No. 2019J01403).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

All of the data reported in the paper are presented in the main text. Any other data will be provided on request.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Powers, P.E.; Ramakrishna, S.; Tang, C.L.; Cheng, L.K. Optical parametric oscillation with KTiOAsO4. Opt. Lett. 1993, 18, 1171–1173. [Google Scholar] [CrossRef]
  2. Zhu, H.Y.; Guo, J.H.; Duan, Y.M.; Zhang, J.; Zhang, Y.C.; Xu, C.W.; Wang, H.Y.; Fan, D.Y. Efficient 1.7 μm light source based on KTA-OPO derived by Nd:YVO4 self-Raman laser. Opt. Lett. 2018, 43, 345–348. [Google Scholar] [CrossRef]
  3. Zhong, K.; Yao, J.Q.; Xu, D.G.; Wang, J.L.; Li, J.S.; Wang, P. High-pulse-energy high-efficiency midinfrared generation based on KTA optical parametric oscillator. Appl. Phys. B 2010, 100, 749–753. [Google Scholar] [CrossRef]
  4. Duan, Y.M.; Zhu, H.Y.; Xu, C.W.; Ruan, X.K.; Cui, G.H.; Zhang, Y.J.; Tang, D.Y.; Fan, D.Y. Compact self-cascaded KTA-OPO for 2.6 μm laser generation. Opt. Express 2016, 24, 26529–26535. [Google Scholar] [CrossRef] [PubMed]
  5. Watson, G.H. Polarized Raman spectra of KTiOAsO4 and isomorphic nonlinear-optical crystals. J. Raman Spectrosc. 1991, 22, 705–713. [Google Scholar] [CrossRef]
  6. Liu, Z.; Wang, Q.; Zhang, X.; Zhang, S.; Chang, J.; Cong, Z.; Sun, W.; Jin, G.; Tao, X.; Sun, Y.; et al. A diode side-pumped KTiOAsO4 Raman laser. Opt. Express 2009, 17, 6968–6974. [Google Scholar] [CrossRef] [PubMed]
  7. Guo, J.H.; Duan, Y.M.; Wang, H.Y.; Zhu, H.Y.; Wei, P.F.; Zhang, J.; Zhao, L.M.; Tang, D.Y. Efficient Nd:YAG\KTiOAsO4 cascaded Raman laser emitting around 1.2 μm. Opt. Mater. 2017, 71, 66–69. [Google Scholar] [CrossRef]
  8. Piper, J.A.; Pask, H.M. Crystalline Raman Lasers. IEEE J. Sel. Top. Quantum Electron. 2007, 13, 692–704. [Google Scholar] [CrossRef]
  9. Sheng, Q.; Ma, H.; Li, R.; Wang, M.; Shi, W.; Yao, J. Recent progress on narrow-linewidth crystalline bulk Raman lasers. Results Phys. 2020, 17, 103073. [Google Scholar] [CrossRef]
  10. Gong, X.H.; Zhu, H.Y.; Chen, Y.J.; Huang, J.H.; Lin, Y.F.; Luo, Z.D.; Huang, Y.D. Nd3+ Cluster Adjustment in Nd3+:CaNb2O6 by Codoping La3+ Buffers for Improvement of Fundamental and Self-Stimulated Raman Scattering Laser Operation: A Study Case from the Perspective of Defect Chemistry. Cryst. Growth Des. 2019, 19, 6963–6971. [Google Scholar] [CrossRef]
  11. Zhang, L.; Duan, Y.M.; Mao, X.H.; Li, Z.H.; Chen, Y.X.; Zhang, Y.J.; Zhu, H.Y. Passively Q-switched YVO4 Raman operation with 816 and 890 cm−1 shifts by respective Raman configurations. Opt. Mater. Express 2021, 11, 1815–1823. [Google Scholar] [CrossRef]
  12. Liu, Y.C.; Chen, C.M.; Hsiao, J.Q.; Pan, Y.Y.; Tsou, C.H.; Liang, H.C.; Chen, Y.F. Compact efficient high-power triple-color Nd:YVO4 yellow-lime-green self-Raman lasers. Opt. Lett. 2020, 45, 1144–1147. [Google Scholar] [CrossRef] [PubMed]
  13. Sun, Y.L.; Duan, Y.M.; Zhang, L.; Yang, Z.Y.; Chen, X.; Huang, X.H.; Zhu, H.Y. Efficient actively Q-switched Nd:YAP/YVO4 Raman laser operation at 1195nm. J. Russ. Laser Res. 2020, 41, 373–377. [Google Scholar] [CrossRef]
  14. Liu, Z.J.; Rao, H.; Cong, Z.H.; Xue, F.; Gao, X.B.; Wang, S.; Tan, W.; Guan, C.; Zhang, X.Y. Single-frequency BaWO4 Raman MOPA at 1178 nm with 100-ns pulse pump. Crystals 2019, 9, 185. [Google Scholar] [CrossRef] [Green Version]
  15. Duan, Y.M.; Zhu, H.Y.; Zhang, G.; Huang, C.H.; Wei, Y.; Tu, C.Y.; Zhu, Z.J.; Yang, F.G.; You, Z.Y. Efficient 559.6 nm light produced by sum-frequency generation of diode-end-pumped Nd:YAG/SrWO4 Raman laser. Laser Phys. Lett. 2010, 7, 491–494. [Google Scholar] [CrossRef]
  16. Chen, Y.F.; Huang, H.Y.; Lee, C.C.; Hsiao, J.Q.; Tsou, C.H.; Liang, H.C. High-power diode-pumped Nd:GdVO4/KGW Raman laser at 578 nm. Opt. Lett. 2020, 45, 5562–5565. [Google Scholar] [CrossRef]
  17. Sheng, Q.; Lee, A.; Spence, D.; Pask, H. Wavelength tuning and power enhancement of an intracavity Nd:GdVO4-BaWO4 Raman laser using an etalon. Opt. Express 2018, 26, 32145–32155. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  18. Yu, H.H.; Li, Z.; Lee, A.J.; Li, J.; Zhang, H.J.; Wang, J.Y.; Pask, H.M.; Piper, J.A.; Jiang, M.H. A continuous wave SrMoO4 Raman laser. Opt. Lett. 2011, 36, 579–581. [Google Scholar] [CrossRef] [PubMed]
  19. Tu, C.S.; Guo, A.R.; Tao, R.W.; Katiyar, R.S.; Guo, R.Y.; Bhalla, A.S. Temperature dependent Raman scattering in KTiOPO4 and KTiOAsO4 single crystals. J. Appl. Phys. 1996, 79, 3235–3240. [Google Scholar] [CrossRef]
  20. Duan, Y.M.; Zhu, H.Y.; Zhang, Y.J.; Zhang, G.; Zhang, J.; Tang, D.Y.; Kaminskii, A.A. RbTiOPO4 cascaded Raman operation with multiple Raman frequency shifts derived by Q-switched Nd:YAlO3 laser. Sci. Rep. 2016, 6, 33852. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  21. Liu, Z.J.; Wang, Q.P.; Zhang, X.Y.; Zhang, S.S.; Chang, J.; Wang, H.; Fan, S.Z.; Sun, W.J.; Tao, X.T.; Zhang, S.J.; et al. 1120 nm second-Stokes generation in KTiOAsO4. Laser Phys. Lett. 2008, 6, 121–124. [Google Scholar] [CrossRef]
  22. Lan, W.X.; Wang, Q.P.; Liu, Z.J.; Zhang, X.Y.; Bai, F.; Shen, H.B.; Gao, L. A diode end-pumped passively Q-switched Nd:YAG/KTA Raman laser. Optik 2013, 124, 6866–6868. [Google Scholar] [CrossRef]
  23. Huang, Y.J.; Chen, Y.F.; Chen, W.D.; Zhang, G. Dual-wavelength eye-safe Nd:YAP Raman laser. Opt. Lett. 2015, 40, 3560–3563. [Google Scholar] [CrossRef]
  24. Liu, Z.; Wang, Q.; Zhang, X.; Zhang, S.; Chang, J.; Fan, S.; Sun, W.; Jin, G.; Tao, X.; Sun, Y.; et al. Self-frequency-doubled KTiOAsO4 Raman laser emitting at 573 nm. Opt. Lett. 2009, 34, 2183–2185. [Google Scholar] [CrossRef] [PubMed]
  25. Zhu, H.Y.; Shao, Z.H.; Wang, H.Y.; Duan, Y.M.; Zhang, J.; Tang, D.Y.; Kaminskii, A.A. Multi-order Stokes output based on intra-cavity KTiOAsO4 Raman crystal. Opt. Express 2014, 22, 19662–19667. [Google Scholar] [CrossRef]
  26. Duan, Y.; Zhu, H.; Wang, H.; Zhang, Y.; Chen, Z. Comparison of 1.15 µm Nd:YAG\KTA Raman lasers with 234 and 671 cm−1 shifts. Opt. Express 2016, 24, 5565–5571. [Google Scholar] [CrossRef] [PubMed]
  27. Pask, H.M.; Dekker, P.; Mildren, R.P.; Spence, D.J.; Piper, J.A. Wavelength-versatile visible and UV sources based on crystalline Raman lasers. Prog. Quantum Electron. 2008, 32, 121–158. [Google Scholar] [CrossRef]
  28. Runcorn, T.H.; Gorlitz, F.G.; Murray, R.T.; Kelleher, E.J.R. Visible Raman-Shifted Fiber Lasers for Biophotonic Applications. IEEE J. Sel. Topics Quantum Electron. 2018, 24, 2770101. [Google Scholar] [CrossRef] [Green Version]
  29. Chang, Y.T.; Huang, Y.P.; Su, K.W.; Chen, Y.F. Diode-pumped multi-frequency Q-switched laser with intracavity cascade Raman emission. Opt. Express 2008, 16, 8286–8291. [Google Scholar] [CrossRef]
  30. Ye, P.P.; Zhu, S.Q.; Li, Z.; Yin, H.; Zhang, P.X.; Fu, S.H.; Chen, Z.Q. Passively Q-switched dual-wavelength green laser with an Yb:YAG/Cr4+:YAG/YAG composite crystal. Opt. Express 2017, 25, 5179–5185. [Google Scholar] [CrossRef]
  31. Duan, Y.; Zhang, J.; Zhu, H.; Zhang, Y.; Xu, C.; Wang, H.; Fan, D. Compact passively Q-switched RbTiOPO4 cascaded Raman operation. Opt. Lett. 2018, 43, 4550–4553. [Google Scholar] [CrossRef] [PubMed]
  32. Dascalu, T.; Croitoru, G.; Grigore, O.; Pavel, N. High-peak-power passively Q-switched Nd:YAG/Cr4+:YAG composite laser with multiple-beam output. Photon. Res. 2016, 4, 267–271. [Google Scholar] [CrossRef]
  33. Frank, M.; Smetanin, S.N.; Jelínek, M.; Vyhlídal, D.; Kopalkin, A.A.; Shukshin, V.E.; Ivleva, L.I.; Zverev, P.G.; Kubeček, V. Synchronously-pumped all-solid-state SrMoO4 Raman laser generating at combined vibrational Raman modes with 26-fold pulse shortening down to 1.4 ps at 1220 nm. Opt. Laser Technol. 2019, 111, 129–133. [Google Scholar] [CrossRef]
Figure 1. Experimental setup of the passively Q-switched KTA cascaded Raman laser.
Figure 1. Experimental setup of the passively Q-switched KTA cascaded Raman laser.
Applsci 11 06895 g001
Figure 2. Transmittance curve of the OC mirror for different wavelengths.
Figure 2. Transmittance curve of the OC mirror for different wavelengths.
Applsci 11 06895 g002
Figure 3. Average output power versus incident pump power of the Raman lasers with the cavity lengths of 5 cm and 9 cm.
Figure 3. Average output power versus incident pump power of the Raman lasers with the cavity lengths of 5 cm and 9 cm.
Applsci 11 06895 g003
Figure 4. Raman laser spectra measured under the incident pump power of 10.5 W with the cavity lengths of 5 cm and 9 cm.
Figure 4. Raman laser spectra measured under the incident pump power of 10.5 W with the cavity lengths of 5 cm and 9 cm.
Applsci 11 06895 g004
Figure 5. Pulse repetition frequency (PRF) and pulse energy versus incident pump power.
Figure 5. Pulse repetition frequency (PRF) and pulse energy versus incident pump power.
Applsci 11 06895 g005
Figure 6. Temporal pulse profiles and pulse trains under the incident pump power of 10.5 W.
Figure 6. Temporal pulse profiles and pulse trains under the incident pump power of 10.5 W.
Applsci 11 06895 g006
Figure 7. Spectra of weak visible light irradiated from the KTA crystal.
Figure 7. Spectra of weak visible light irradiated from the KTA crystal.
Applsci 11 06895 g007
Table 1. Stokes wavelengths with contributed Raman shifts.
Table 1. Stokes wavelengths with contributed Raman shifts.
Wavelength
(nm)
Contributed Raman Shifts
ωR1 = 234 cm−1, ωR2 = 671 cm−1
1092.0ωR1
1120.7R1
1146.8ωR2
1150.4R1
1178.2ωR2 + ωR1
1182.4R1
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Xie, Z.; Lou, S.; Duan, Y.; Li, Z.; Chen, L.; Wang, H.; Zhang, Y.; Zhu, H. Passively Q-Switched KTA Cascaded Raman Laser with 234 and 671 cm−1 Shifts. Appl. Sci. 2021, 11, 6895. https://doi.org/10.3390/app11156895

AMA Style

Xie Z, Lou S, Duan Y, Li Z, Chen L, Wang H, Zhang Y, Zhu H. Passively Q-Switched KTA Cascaded Raman Laser with 234 and 671 cm−1 Shifts. Applied Sciences. 2021; 11(15):6895. https://doi.org/10.3390/app11156895

Chicago/Turabian Style

Xie, Zhi, Senhao Lou, Yanmin Duan, Zhihong Li, Limin Chen, Hongyan Wang, Yaoju Zhang, and Haiyong Zhu. 2021. "Passively Q-Switched KTA Cascaded Raman Laser with 234 and 671 cm−1 Shifts" Applied Sciences 11, no. 15: 6895. https://doi.org/10.3390/app11156895

APA Style

Xie, Z., Lou, S., Duan, Y., Li, Z., Chen, L., Wang, H., Zhang, Y., & Zhu, H. (2021). Passively Q-Switched KTA Cascaded Raman Laser with 234 and 671 cm−1 Shifts. Applied Sciences, 11(15), 6895. https://doi.org/10.3390/app11156895

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop