Next Article in Journal
Comparison of Rate of Force Development between Explosive Sustained Contractions and Ballistic Pulse-like Contractions during Isometric Ankle and Knee Extension Tasks
Next Article in Special Issue
Trapping and Methanation of CO2 in a Domestic Microwave Oven Using Combinations of Sorbents and Catalysts
Previous Article in Journal
MCF-Net: Fusion Network of Facial and Scene Features for Expression Recognition in the Wild
Previous Article in Special Issue
Voltammetric Study for the Determination of Diclofenac in Aqueous Solutions Using Electro-Activated Carbon Electrodes
 
 
Article
Peer-Review Record

Reduction of Water Color in a Spinning Disc Reactor

Appl. Sci. 2022, 12(20), 10253; https://doi.org/10.3390/app122010253
by Eugenia Teodora Iacob-Tudose 1, Carmen Zaharia 2,* and Nicoleta Melniciuc-Puica 3
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Appl. Sci. 2022, 12(20), 10253; https://doi.org/10.3390/app122010253
Submission received: 18 September 2022 / Revised: 2 October 2022 / Accepted: 11 October 2022 / Published: 12 October 2022
(This article belongs to the Special Issue Pollution Control Chemistry II)

Round 1

Reviewer 1 Report

Comments in pdf-file

Comments for author File: Comments.pdf

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 2 Report

Please rewrite and organize the results well because it’s difficult to understand and may cause some confusion. Please consider the importance of figures or tables to support the conclusion and no repetition.

1.     In the abstract, line 27 what does FT-IT means?

2.     Please check the abbreviation of FT-IR or FTIR throughout the manuscript.

3. Section 2. Materials and Methods: please indicate how to obtain material type ZnAlLDH.

4.     Recheck Figure 2 (d) 800 rpm.

5.  This study provides only FTIR analysis before and after dye treatment, in case of studying different types of adsorbents, various characterization techniques may be useful for discussion of the results.

6. Table 4 should be modified for easier understanding.

7.     Figure 6: please add the variable names and their units on the y-axis.

8.    Discussion section should have the subsection related to the section of results.

9.  Conclusion does not provide enough a clear interpretation of the results of this study.

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Round 2

Reviewer 2 Report

Authors have modified and corrected to improve their paper so I think that it is possible to publish in this journal.

Back to TopTop