Next Article in Journal
A Comparative Study on the Effect of Peri-Implant Infection Management Lasers (1064-nm Q-Switch Nd:YAG, 1064-nm Nd:YAG and 980-nm Diode) on Titanium Grade 4 Surface
Previous Article in Journal
Aerodynamic Drag Reduction on Speed Skating Helmet by Surface Structures
Previous Article in Special Issue
Damage Mode Analysis of Steel Box Structures Subjected to Internal Blast Loading
 
 
Article
Peer-Review Record

Static Compressive Properties of Polypropylene Fiber Foam Concrete with Concave Hexagonal Unit Cell

Appl. Sci. 2023, 13(1), 132; https://doi.org/10.3390/app13010132
by Zhiqiang Yin 1,2,*, Zhenguo Shao 1, Chao Qi 1, Haoyuan Wu 1, Jianen Wang 1 and Lulu Gao 1
Reviewer 2:
Reviewer 3: Anonymous
Appl. Sci. 2023, 13(1), 132; https://doi.org/10.3390/app13010132
Submission received: 21 October 2022 / Revised: 30 November 2022 / Accepted: 6 December 2022 / Published: 22 December 2022
(This article belongs to the Special Issue Vehicle Crashworthiness and Lightweight Design)

Round 1

Reviewer 1 Report

General considerations.

The article is very interesting and show the new materials analyses. But I suggest that explanations about Negative Poisson's ratio can be summarized (one paragraph 5 – 7 lines).

Another important point is the balance of the article. The initial statements lead to analyses on two different samples. But the results and conclusions focus on Concave Hexagonal Unit Cell.

The results are exchange in the many times this causes the confusion during evaluation.

Comments for author File: Comments.pdf

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 2 Report

Accept in present form

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 3 Report

In this paper, the test results of the influence of fiber on the negative Poisson's ratio effect of foam concrete are shown. A concave hexagonal unit cell structure of polypropylene fiber foam concrete are considered. The research topic of the manuscript is novel and it fits on the journal purpose.

The reviewer recommends the publication of this paper after solving the following issues:

1. In Figure 4, the stress (or force) value for each from the cloud diagrams in the DIC (Digital Image Correlation) is missing,

2. In Figure 6, the (a) Stress-Deformation and (b) Stress-Time plots are missing.

3. Could you explain so short testing time (less than 160 sec. - see Figure 6)? Usually static tests shall last about 300 (+/-120) sec.

4. Some editorial issues shall be addressed, such as:

- in rows No. 95, No. 97, No. 99: 9 mm, 50 mm x 50 mm x 50 mm with a gap between a number and units,

- in row No. 112: 50 mm x 50 mm x 50 mm shall be written in the same row, 

- in Table 1: editing of the heading row is required.

5. Also, I recommend to add some literature such as e.g. "Meskhi, B.; Beskopylny, A.N.; Stel’makh, S.A.; Shcherban’, E.M.; Mailyan, L.R.; Beskopylny, N.; Chernil’nik, A.; El’shaeva, D. Insulation Foam Concrete Nanomodified with Microsilica and Reinforced with Polypropylene Fiber for the Improvement of Characteristics. Polymers 2022, 14, 4401. https://doi.org/10.3390/polym14204401"

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Back to TopTop