Next Article in Journal
Multi-Scale Indoor Scene Geometry Modeling Algorithm Based on Segmentation Results
Next Article in Special Issue
Design and Optimization of an Interior Permanent-Magnet Synchronous Motor for Aircraft Drive Application
Previous Article in Journal
Deep Learning-Based Efficient Analysis for Encrypted Traffic
Previous Article in Special Issue
A Multi-Bandwidth Reconfigurable Patch Antenna for Devices in WLAN and UWB Technology Applications
 
 
Article
Peer-Review Record

Loop-Type Field Probe to Measure Human Body Exposure to 5G Millimeter-Wave Base Stations

Appl. Sci. 2023, 13(21), 11777; https://doi.org/10.3390/app132111777
by DukSoo Kwon, Young Seung Lee, Chang-Hee Hyoung, Jung-Hwan Hwang * and Hyung-Do Choi
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Reviewer 3:
Reviewer 4: Anonymous
Appl. Sci. 2023, 13(21), 11777; https://doi.org/10.3390/app132111777
Submission received: 25 September 2023 / Revised: 20 October 2023 / Accepted: 25 October 2023 / Published: 27 October 2023

Round 1

Reviewer 1 Report

Comments and Suggestions for Authors

This paper introduces a field probe designed to measure power density (PD) in the millimeter wave frequency band (28 GHz). The probe enables simultaneous measurement of electric and magnetic fields, allowing for PD measurement in the near field region. The manuscript is well-written, well-organized, and of significant interest to readers interested in the field of 5G mmWave. I have the following questions:

·         Figure 5 shows the experimental setup of measuring the radiation pattern, however, the radiation pattern in the Azimuth or elevation direction was not displayed. Would the authors clarify this point?

 

·         What is the bandwidth of this probe antenna?

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 2 Report

Comments and Suggestions for Authors

The authors are encouraged to submit a revised version of their manuscript, taking into consideration the following minor issues:

1. Authors should clearly explain the motivation behind this work.

2. Authors are recommended to improve the state of the art analysis by discussing more related works. The related work discussed should be form more recent years like 2022, 2023.

3. Authors should give more details of the design methodology and also provide numerical analysis of the design process.

4. There are few grammatical mistakes in the manuscript. Authors are suggested to proof read the manuscript thoroughly for language and grammatical mistakes or use any professional tool for this purpose.

Comments on the Quality of English Language

There are few grammatical mistakes in the manuscript. Authors are suggested to proof read the manuscript thoroughly for language and grammatical mistakes or use any professional tool for this purpose.

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 3 Report

Comments and Suggestions for Authors

Dear Authors

PD is measured using a field probe at the millimeter wave (mmWave) frequency band. An antenna loop with a load resistor attached to one end is used in the proposed probe.

The references are not updated. The newest one is 2022.

Thanks

 

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 4 Report

Comments and Suggestions for Authors

In this paper, the authors proposed a field probe to measure power density (PD) at millimeter wave (mmWave) frequency band. The simultaneous measurements of electric (E)- and magnetic (H)-fields were given. In my opinion, the main results are interesting. Therefore, I recommend it accepted. 

Author Response

Please see the attachment.

Author Response File: Author Response.pdf