1. Introduction
Population growth, climate change, and increasing electricity demand have driven governments to utilize novel energy management systems such as microgrids (MGs) and smart grids (SGs) instead of traditional power networks [
1]. MGs support a flexible and efficient power network by enabling the integration of renewable energy sources (RESs) instead of conventional power plants [
2,
3]. Moreover, the management of green-energy-supporting technologies such as electric vehicles (EVs) and energy storage systems (ESSs) is more straightforward in small SGs [
4,
5]. The use of local energy units reduces energy losses in transmission and distribution systems and increases the efficiency and quality of the electricity system. Although renewable sources have lower carbon losses and their energy is available in most parts of the earth, their energy is stochastic and variable during the day and year [
6,
7]. Electrical storage systems are the solution for stabilizing the produced energy from renewable sources. Electric vehicles, the main system of which is a storage system, are other practical technologies for reducing air pollution and increasing social welfare [
8]. In recent years, considerable development of renewable resources and energy storage systems has been achieved due to the promotion of technologies of MGs, SGs, and also EVs.
Modeling, estimating, and controlling the utilized devices such as renewable energy sources and energy storage systems in microgrids are important and complex. Fractional-order methods are a practical way to enhance energy system performance [
9,
10]. The FO calculus can be used in integer-order and non-integer-order models [
11], and the results of the previous studies have proved that fractional-order techniques are very suitable and flexible ways to characterize the properties in various energy processes [
12]. So far, researchers and operators have modeled many practical systems in energy fields such as wind turbines [
13], hydro-turbine governing systems [
14], chaotic systems [
15], energy supply–demand systems [
16], permanent magnet synchronous generator systems [
17], and microgrids [
18] by using fractional-order equations. The FO methods also have proper performance in the estimation of parameters of energy systems [
19], especially in energy storage systems, the characteristics of which such as the state of charge [
20], state of energy [
21], state of health [
22], and state of temperature [
23] are particularly important to estimate for maintaining the safe and efficient operation of storage systems. Controlling the energy system’s process, which causes the system’s performance to remain unchanged, is another practical application of fractional-order methods [
24,
25]. The FO techniques are utilized to control various performance parameters of energy systems, such as voltage [
26], current [
27], power [
28], temperature [
29], and cost [
30]. Engineers use fractional-based controllers to control the practical energy systems of different technologies such as wind turbines [
31], photovoltaic panels [
32], electric vehicles [
33], and storage systems [
34].
In recent decades, the tendency and motivation to utilize low-carbon and renewable power resources have increased considerably due to the rareness of fossil fuels and increased environmental problems. According to statistical data on world energy in 2022, more than one-third of the consumed electricity was approximately generated by low-carbon units including hydropower, nuclear, solar, and wind generations [
35,
36]. Renewable resources are expected to play a larger role in electricity generation in the coming years, facilitated by the use of microgrids (MGs), smart grids (SGs), and smart homes (SHs) [
37]. It should be considered that due to the stochastic performance of renewable resources, their control and management systems have a high impact on their performance and the efficiency of the total power network. Renewable energy resources exhibit significant fluctuations in power generation due to the unpredictable nature of their primary energy source. Their stochastic behavior affects the power quality, frequency, and voltage of the power network [
38]. The produced stochastic power of RESs and the necessity of utilization of ESSs in the power system introduce new controlling and management challenges. The utilization of the appropriate control technique has a high effect on the optimal performance of the renewable units and the power network [
39]. In other words, the high penetration rate of green technologies presents critical problems for power systems. Control programs are an important way to resolve this problem in which frequency fluctuation and other dangerous issues are observable. Control methods such as fractional-order proportional integral derivative (FOPID) [
40,
41], fractional-order cascade controller [
42], proportional integral (PI) [
43], proportional derivative (PD) [
44], proportional integral derivative (PID) [
45], fuzzy methods [
46,
47], model predictive control (MPC) [
48,
49], tilted integral derivative (TID) [
50], and a hybrid method of TID and FOPID [
51] have been utilized in different studies for improving the efficiency of renewable energy systems. Moreover, these control methods have been implemented for improving the inertia of the power system when various low and high disturbances occur in the devices and systems. Fractional-order (FO) control methods are also used for power converters in renewable energy systems. This flexible control and power converter technique decreases the overshoot level and settling time and increases the rising time. Fractional-order controllers have better dynamics, steady-state error, and stability than traditional controllers such as PI, PD, and PID. Moreover, the efficiency of the fractional-order controller, which can be defined as the ratio of the controlled output parameter to the input parameter, is higher than that of the other ones [
52].
ESSs are employed to enhance the stability of the overall power system by bridging the gap between energy generation and consumption. Moreover, they are used in EVs to provide the required power for the vehicle. The energy storage systems technologies can be divided into four groups: electrical ESS, electrochemical ESS, electromechanical ESS, and thermal storage system [
53,
54]. Lithium-ion batteries (LIBs) and supercapacitors are among the most commonly utilized ESSs in MGs and EVs. The long lifetime, low self-discharge rate, and high energy and power density are the most highlighted advantages of LIBs. On the other hand, shortcut problems and heat-runaway are one of their disadvantages. To increase their performance and prevent problems, reliable situation estimation is so essential. Supercapacitors or ultra-capacitors are powerful energy storage devices with more abilities than batteries and capacitors. They can be charged more than capacitors and discharge more power than batteries [
55,
56]. The control and management systems of energy storage devices are developed to control and monitor the different parameters such as the state of charge (SOC), state of power (SOP), and state of health (SOH) in order to ensure the safety and reliability of the storage system [
57]. The battery’s SOC presents the battery’s available stored energy, while the SOP shows the rate of the battery working in extreme conditions [
58,
59]. The SOH of the storage system indicates its degradation and remaining capacity. In other words, this index compares the remaining charge of the storage system with its rated value [
60]. The stability and robustness of the estimation value of each of these parameters are required for appropriately modeling the storage system [
61]. The accurate estimation of the ESS’s situation is crucial for its proper management. Although different methods such as artificial neural networks (ANNs) [
62], the support vector machine [
63], the learning machine [
64], fuzzy logic [
65], the open circuit voltage method [
66], and ampere-hour integration [
67] have been used for predicting the ESSs, three techniques including the electrochemical model [
68], integer-order model [
69], and fractional order [
70] are more commonly utilized methods. The integer-order model, called the equivalent circuit model, considers resistance capacitance systems [
69]. The electrochemical model presents differential algebraic formulas about the intern electrochemical reactions of the storage device [
68]. The FO model, which is more complete and effective than these two methods, considers the electrochemical characteristics without considering the equivalent circuit model. This method considers the fractional impedances, including the constant phase element (CPE) and Warburg element [
70]. The FO model has more stability than traditional methods and finds the proper results in a lower time. Therefore, it can be applied to online and real applications.
Figure 1 demonstrates a comprehensive structure of fractional-order methods in systems of renewable energy systems and energy storage systems. As can be shown in this figure, fractional-order methods have been utilized in renewable energy systems of WTs, PVs, geothermal systems, and some hybrid systems. In these systems, different fractional-based systems such as FOPID, FOPD, FO-TID, and FOI-TD have been investigated. In energy storage systems, the majority of fractional-order systems have been applied on LIBs, LMBs, SMESSs, and supercapacitors. The application of fractional-based systems in ESSs can be divided into three main categories including modeling, estimating, and controlling. Based on the formulation, four definitions including GLD, RLD, CD, and OSD are most utilized in fractional-order systems. Some assistive techniques are used in the fractional-order method to improve its performance. In the following, the details of different applications, definitions, objectives, and assistive techniques of fractional-order methods are presented.
1.1. Motivations
Although in recent years, some authors considered fractional-order techniques for modeling, estimating, and controlling the energy systems of RESs and ESSs and modifying their performance, there was no overall research on applications of FO methods on the energy systems of these devices. For this reason, it motivated us to prepare an overview of previous studies on fractional-order methods and the energy systems of RESs and ESSs. Moreover, we wanted to present a framework of important formulations and definitions of FO techniques that can be applied to practical and experimental energy systems for researchers and engineers. On the other hand, RESs and ESSs appropriately complement each other in the power network so that RESs inject renewable and eco-friendly energy into ESSs while ESSs increase the stability and quality of the produced energy of RESs. It was another reason to prepare a review paper about applications of FO techniques in both RESs and ESSs so that readers can easily see the advantages and disadvantages of FO-based estimating, modeling, and controlling methods of RESs and ESSs in a comprehensive article. In other words, we present important details of the latest articles about applications of fractional-order methods in RESs and ESSs, such as objectives, optimization methods, electrical circuit models, identification methods, remarkable numerical results, advantages, and disadvantages, in this review paper in order to comprehensively evaluate the performance of FO methods in energy systems of renewable units and storage devices. Thus, the main motivations of this review paper are as follows:
1. Providing a detailed explanation of fractional-order control techniques and their applications in renewable energy and energy-storage-integrated power systems.
2. Summarizing the current research findings on the use of fractional-order control techniques in these systems, including their advantages and limitations.
3. Comparing and evaluating different fractional-order control techniques used in renewable energy and energy-storage-integrated power systems based on their performance and applicability.
4. Identifying challenges and opportunities for future research in this field and suggesting possible directions for further investigation.
1.2. Methodology
To extract appropriate and adequate resources for evaluating the applications of FO methods in RESs and ESSs, published papers in the last decade that have considered FO techniques for estimating, modeling, and controlling the energy systems of RESs and ESSs were gathered from international scientific databases, such as IEEE and ScienceDirect. Some important and practical keywords, such as fractional-order controllers, estimation methods, modeling techniques, renewable sources, energy storage systems, photovoltaic panels, wind turbines, electrochemical impedance spectroscopy, lithium-ion battery, parameter identification, and state of charge were considered for selecting the proper and related papers. After reviewing these articles, the papers with high relevance to the applications of FO methods in RESs and ESSs were divided into two main categories, including renewable energy systems and energy storage systems, for more detailed evaluations. The explanations of the proposed method, the application of the fractional-order technique in the energy system, the utilized equations, objectives, constraints, assistive techniques, numerical results, and the comparison data with other methods are the extracted details from the reviewed articles. They are explained and categorized in the following sections. Moreover, the formulations and methods of some papers are considered for simulation and evaluation of the FO methods, and simulation results are presented and explained using figures and tables.
Therefore, in this review paper, after presenting the main formulations of FO methods in the energy systems, previous studies about FO methods that have been utilized in the energy systems of RESs and ESSs are considered for reviewing FO controllers and systems. These studies are divided into two sections, including (a) fractional-order techniques and renewable energy systems and (b) fractional-order techniques and energy storage systems. The papers of each section are evaluated deeply based on the methods, objectives, advantages, and disadvantages. Moreover, their details, such as the models, type of controllers, optimization methods, electrical circuits, identification methods, and objectives, are also categorized and summarized for easy access to an overview of applications of FO methods in the energy systems of RESs and ESSs. After pondering different studies, some suggestions for future research on FO methods are presented.
Table 1 presents a summary of the remaining sections in this paper, with the key objectives of each section.
3. Fractional-Order Technique and Renewable Energy Sources
In this section, several papers that follow different objects are reviewed. In these papers, FOPID and conventional controllers are utilized to improve steady-state performance. This section focuses on FO controllers used for renewable energy systems.
Table 2 is mentioned to point the readers to an overview of papers that studied fractional-order techniques in renewable energy systems. This table summarizes the application of fractional-order methods in renewable energy systems. The types of the used controller, function, algorithm, and type of distributed generation unit of each paper are available in this table.
Table 2 shows that most authors have used the FOPID controller for renewable energy systems. The TID controller is another practical method. The metaheuristic algorithms are utilized in most papers for optimizing the controller parameters. On the other hand, the MPPT is the most iterated function due to the role of the power amount without distortion. The major objective of the papers is to minimize the nonlinearity and uncertainty of the system, which causes unstable situations in the steady-state condition.
In the papers associated with fractional-order methods and renewable energy sources, FOPID controller, photovoltaic panel, and wind turbine are the most utilized keywords. In other words, the FO method has been utilized to control the most common types of renewable energy resources, mainly WTs and PVs. Different types of controllers, methods, and optimizations are other types of information that can be found in
Table 2. For example, all the papers develop their controllers based on the FOPID controller. Based on the method, the MPPT is the most popular method in photovoltaic panels, while the SMES is the most popular approach in wind turbines. Moreover, one of the vital parts of implementing the suggested control method is to select an appropriate optimization approach, and the reviewed papers demonstrate that metaheuristic algorithms have extensive stocks in the papers.
In the first reviewed paper on fractional-order application in the RESs, the authors proposed a specific algorithm to reach maximum power [
101]. In that study, due to uncertain irradiation, the maximum power point tracking (MPPT) approach was implemented in the photovoltaic panels (PVs) by combining step size variables. According to
Figure 3, for eliminating the disturbance factor of MPPT, the novel FOPID controller was attached by an incremental conductance algorithm. The results illustrate enhanced steady-state performance [
101]. In [
63], focusing on MPPT in PV panels, a new novel approach is presented by combining incremental conductance and FOPID. According to the obtained results, the loss of output voltage is reduced considerably. In [
64], a study to reduce perturbation in the output voltage of PV panels was conducted. In this research, MPPT through the perturb and observe (PO) technique under uncertain atmospheric situations was investigated. Reshaped output power by adding FOPID, which is tuned by the grey wolf optimization (GWO) technique, causes an improved transient factor in the result of the edited system. In [
65], a novel high-energy tracking system from PV panels based on the perturb and observe technique was presented. In this paper, several events, such as inverter nonlinearity, the uncertainty of irradiation, and temperature, were adopted in the model. For compensating the PO technique, a FOPID controller is employed, and the optimal tuning of its parameters is obtained using the yin yang pair algorithm [
102].
In the other paper, a geothermal power plant, dish Stirling, and high voltage DC system are connected to an uncertain environment. The specific scheme is presented for reducing the effects of harmonic distortion and having a robust system. The mixed FOPI-FOPID controller is replaced in the system and, using the sine cosine algorithm (SCA), the optimal adjustment of the parameters of the controller is conducted. The obtained results show improvements in the transient index such as overshoot and rise time [
103]. Another application of the FOPID controller in the hybrid RES with combined energy storage was presented. The goal of the paper was to seek the objective frequency at which the system deviated from the equilibrium point, and after obtaining the result, the approach was validated with the mean square error method [
104]. In [
105], a fractional-order controller was presented to reduce tension and increase the robustness of the system. In this research, a novel controlling regime based on a fuzzy FOPID controller was proposed for hybrid renewable resources used for power generation and plentiful switching. The combination of the particle swarm optimization and chaotic map is utilized to extract the transient parameters of the controller [
105].
In [
106], research was presented for contrasting unstable situations and ensuring power quality in smart residential hybrid RESs. In this paper, a new FO controller implemented on an inverter’s output break is controlled with the pulse-width modulation (PWM) method. A comparison of the proposed controller with the conventional controller shows a reduction in the tension of the output voltage [
106]. Another paper about wind turbine (WT) output controllers was proposed in [
107]. Fuzzy FOPID is replaced in the DC-AC converter section due to the uncertainty of wind speed and grid-connected wind power plants for reducing the effects of the dynamic situation. Rise time and fall time are improved by the tuning of controllers using the teaching–learning-based optimization (TLBO) algorithm overshoot [
107]. In another paper, the pitch angle method was proposed for controlling the rotor speed and power production of the WT [
108]. In this research, the FOPID controller is replaced with a radial basis function (RBF) neural network for improving system performance, and the chaotic optimization parameter of FOPID is tuned optimally. The result shows that by attaching the FOPID controller, the system’s flexibility and robustness are increased in comparison to conventional controllers [
108]. The authors of [
109] designed a novel approach to deal with nonlinearity and increase the performance of the energy system. A FOPID controller is designed to cope with the destructive effects of the parameters. A numerical evaluation of the FOPID controller with a combined gain-scheduling algorithm and concentrated solar plant nonlinear model indicates its high performance in comparison with other controllers [
109]. In another paper, the FOPID controller was presented due to the nonlinearity of the V-I characteristic of the PV panel [
110]. In that paper, the boost DC-DC converter is utilized in the PV panel for regulating the output voltage. Moreover, particle swarm optimization is proposed for modifying the parameters of the FOPID controller [
110].
Two controllers were presented for balancing the dynamic behavior of grid-connected PV panels in [
111]. In this paper, metaheuristic algorithms such as cuckoo search (CS), GWO, the whale optimization algorithm (WOA), the mine blast algorithm (MBA), ABC, and the moth swarm algorithm (MSA) are used to optimize FOPI and PID controller parameters to reduce transient factors such as settling time and overshoot [
111]. A study for mitigating the effects of renewable units and EVs present in the power system was proposed in [
112]. In this paper, a controller consisting of both FOPID and TID controllers is presented to reduce frequency fluctuation and tie-line power deviation. The artificial ecosystem-based optimization (AEO) method for tuning parameters is used. Therefore, it can be said that the existence of different controllers with distinct performances increases the robustness and flexibility of the system [
112]. A TID fractional-based controller was proposed for mitigating sensitive load and generation fluctuation. The power generation of RESs is penetrated to the power system due to the lowering of system inertia and unbalancing of the load and frequency. Therefore, load frequency control (LFC) and virtual inertia control (VIC) are proposed for compensating for RESs’ penetration problems. Two TID controllers for each segment are placed using hybrid genetic PSO parameters of controllers, which use a case study combining RESs and conventional power production. In comparison to PSO and GA, the proposed algorithm is more effective and robust [
113].
In [
114], a new FOPD-LFC was proposed for covering the deficit of connecting RESs to the power grid due to power exchange and its violation. This paper aims to minimize the integral time absolute error (ITAE) with skill optimization. The proposed method was evaluated in two case studies, and the results were compared with the results of the jumping spider optimization algorithm and bonobo optimization. The proposed FO-based method has more reliability and stability than other algorithms [
114]. A novel approach for controlling the nonlinearity of a system with RESs was proposed in [
115]. The considered system has nonlinear loads and variable generation units. Therefore, the FOI-TD controller was designed for reducing the nonlinearity, and a hybrid sine cosine algorithm with a fitness-dependent optimizer was utilized to tune the controller’s parameters. The result shows that the proposed algorithm outperforms other algorithms such as the fitness-dependent optimizer and PSO. Additionally, the designed controller reduces the overshoot and rise time [
115]. The essential need for controlling the multi-area power system with renewable resources was investigated in [
116]. In this paper, a new FOPID for controlling LFC and the superconducting magnetic energy storage system (SMESS) is designed. The optimum points of the FOPID parameters are determined using the manta ray foraging optimization (MRFO) algorithm. Robustness and flexibility against nonlinearity is a prominent characteristic of the proposed controller [
116].
4. Fractional-Order Technique and Energy Storage Systems
In the last decade, energy storage systems have been widely utilized in MGs and EVs. Online and accurate modeling and estimation are essential to efficiently operate the storage systems and their upper energy system. The main purpose of studies on fractional-order control systems in ESSs is to improve the estimation rate of the SOC, state of energy (SOE), or other essential and uncertain parameters of the battery. In this section, the applications of FO techniques in the energy systems of different energy storage devices are presented and discussed based on various types of research.
Fractional-order method, lithium-ion battery, state of charge, Kalman filter, electrochemical impedance spectroscopy, and parameter identification are the most repeated keywords in the papers on FO methods and ESSs. In
Table 3, the details of articles on FO techniques and ESSs are presented. In this table, different parameters of each paper such as ESS models, FO-based structures and technologies, and main objectives are given.
While the LIB has been considered as the energy storage device in most of the studies, such as [
119,
125,
137], in papers [
141,
149,
150], the entire structure of the energy storage system has been studied. The particular type of energy device has not been considered. In [
120,
148], both lithium-ion and supercapacitor ESSs have been considered. In these articles, the performance of different storage devices and the application of the FO model have been compared and evaluated. The supercapacitor ESS has been investigated in Refs. [
34,
127,
143]. The authors of [
123] proposed fractional-order techniques for the LMB. Refs. [
129,
151] are also about superconducting magnetic energy storage. According to the literature, LIBs are more efficient for practical operation, and therefore, the main focus of most research is on this type of ESS.
In [
119], the fractional-order impedance model was investigated to overcome the drawbacks of electrochemical and electrical circuit models. The fractional parameters and electrochemical impedance spectroscopy (EIS) data were utilized in the defined impedance model. The GA was used to identify the order of the fractional elements after achieving the state space equations of the model by the GLD. The performance of the FO model was improved by utilizing the Kalman filter (KF) and short memory techniques. The numerical results presented that the proposed fractional-order model can improve the estimation rate of the SOC of the battery so that its estimation error is around 3%. The application of the FO model in the energy system of LIBs and ultra-capacitors was experimentally evaluated in [
120]. The EIS and temperature-compensating fractional models of batteries and capacitors were presented, and the PSO algorithm was considered to identify the online parameters. Based on the numerical results, the presented FO model can obtain a more accurate value of stochastic parameters with less than 4% error. The authors of [
121] suggested FO estimation and control algorithms for the electrical storage system. The combination of the particle swarm optimization method and the GA was used to identify the parameters of the fractional model. Its structure was defined by evaluating a series of pulse tests at various levels of the battery’s charge. Moreover, online charge estimation was used to increase the convergence speed and obtain more accurate results. In the proposed FO model, the behavior of the battery over different current and voltage rates was also researched. Numerical results, achieved under various load profiles, presented that the proposed FO-based estimation method has more accurate results than KF-based methods by up to 1.2%.
In [
122], a factional-order model was presented to estimate the SOC of batteries, especially lithium-ion types. In the proposed model, the charging and discharging characteristics were described using a circuit model and then the model parameters were identified by the PSO algorithm. The proposed order-dependent model was evaluated utilizing real-time experimental data. The results showed the feasibility and validity of the FO model to observe the more accurate rate of battery charge. The authors of [
123] investigated the fractional order model and EIS for liquid metal batteries (LMBs) as one of the practical ESSs in the last few years. The general electrochemical reaction process was considered to define the fractional-order circuit model. Moreover, the impedance spectra were analyzed to extract the parameters of the battery. The results, achieved from simulations and experiments, presented good performance and stability of the FO model for the battery management system. In [
124], the relationship between the FO and electrode aging was investigated. The utilized battery for studying was the lithium-ion type. The system of the FO model was identified using the transient discharge dataset of the fully charged situation of the battery. The numerical results, which were achieved by applying the model to the actual data, presented that the FO can properly evaluate the degradation level of electrodes so that there is a steady relationship between the proposed model and the charging/discharging cycle of the battery. On the other hand, the battery life is terminated when the FO model tends to be stable.
The short- and long-time evaluation of the dynamic of ESSs was presented in [
125] considering frequency parameters. In this study, the FO model was defined using modified electrochemical impedance spectroscopy. The modified version of the impedance model appropriately selected the internal dynamics in both short and long periods. Moreover, it could capture the low-frequency dynamics of the battery. Numerical results showed the high performance and proper adaptability of the proposed FO model to evaluate the dynamics of the battery in different operating conditions so that the maximum error was below 0.86%. The authors of [
126] studied the application of the FO model to show the effect of thermal and electrolyte variations on LIBs. The polarization in electrolytes was utilized to modify the proposed FO model. In the proposed model, the heat absorption/generation of the battery cell was also described using the particle thermal model. The numerical evaluations presented high stability of the modified fractional-order model in various ranges of current, voltage, and temperature. In [
127], the FO model was presented to explain the frequency-dependent behavior of electrical storage devices in energy systems. In this research, both the transient and steady modes of the storage system were considered to evaluate the electrical system of the fractional-order capacitance and inductance. The fractional-order coils and supercapacitors were utilized to verify the proposed FO model. The results expressed the proper performance of the proposed model to present the level of stored energy in commercial electrical storage devices. An FO model, which was modified using the Kalman filter, was presented in [
128] to estimate the SOC of batteries. The LIBs were studied in that paper. In that paper, the FO model describes the physical behavior of the battery. The GA was utilized to identify the parameters of the model. The KF was also used to modify the proposed model in order to increase the stability of the estimation and better track the noise variance. The experimental data presented that the proposed FO-based model performs better and more accurately than the traditional KF-based models.
The authors of [
34] developed an FO control method for the supercapacitor type of ESSs. In the defined model, the inherent physical characteristics of the storage system and the transient responses were considered and analyzed to obtain global control stability. Moreover, the sliding-mode control was also applied to the FO model to improve the robustness of the closed-loop system. The proposed control method was evaluated under different energy situations and the presence of various energy sources in the distribution system. The results presented more stability and feasibility of the FO-based model than the other control methods. Ref. [
129] suggested a nonlinear control method utilizing FO control for analyzing the ESS. The ESS was a combination of battery and superconducting magnetic storage. The proposed FO control model has the ability to compensate for the nonlinearities and model the uncertainties through online estimation. Moreover, it improves the control performance of the ESS while only the voltage and current of the storage are measured instead of accurate modeling of the system. The numerical evaluation of the proposed method showed that the FO control method improves the storage system’s performance and reduces the control costs of the system more than other control methods such as sliding-mode control and feedback linearization control. An FO model was proposed in [
130] to estimate the electrochemistry dynamics of lithium-ion batteries. The GA was used to identify the parameters of the proposed model. Moreover, the KF was utilized to modify the FO control method in estimating the SOC. The proposed control method was simulated and compared with the Thevenin model. The numerical results showed that the FO control method is more accurate and robust than the other one. The authors of [
131] presented a physics-based fractional-order model for simply analyzing the cycle of energy storage devices. This study focused on lithium-ion batteries. The dynamics of medium-high frequency were considered to define the full-cycle model. For this reason, it can be applied to the full-cycle operation of the battery. The proposed physical fractional-order model was evaluated using different loads. The obtained results presented that the defined model has suitable performance for online applications, so it has high stability in extracting the solid phase diffusion. In [
132], a new technique based on the FO method was introduced to estimate the SOC of the battery. The proposed model was based on the open circuit voltage. The PSO method was utilized to select the parameters of the FO-equivalent model. To increase the accuracy and convergence rate of the estimation method, a particle filter, which was modified by an adaptive noise updating algorithm, was added to the proposed FO model. The numerical results, achieved by applying the proposed method to static and dynamic conditions, showed the appropriate convergence rate and high stability of the proposed charge estimation method. The state of power of LIBs was investigated in [
133]. It is worth mentioning that in the evaluation of the SOP, it is considered that the battery is working with the maximum possible power rate. In this paper, the factional-order model was suggested to estimate the power level of the battery. In this model, the voltage, current, and SOC of the battery were modeled by FO calculus. The numerical results presented that the proposed estimation model with approximately 1.34% error has high accuracy for calculating the SOP of the battery in different operating conditions. The authors of [
134] proposed another FO-based model for estimating the SOC of lithium-ion storage devices. In the presented method, the FO model was modified using a Kalman filter and EIS in order to reduce the error rate of the electrical equivalent circuit and increase the stability of the model. The parameter of the model was identified by the quantum particle swarm optimization algorithm. Moreover, the Grünwald–Letnikov fractional derivative and time-varying measurement error covariance were added to the model to promote the convergence speed of the estimation method. The simulation results showed a better performance of the FO model compared to other estimation methods to estimate the state of the charge of the battery.
In [
135], to find the correct charge level of LIBs, a new fractional-order model was presented. The KF was utilized in this technique to increase the adaptive ability of the estimation method in a complex operating state. The Sigmoid function was added to the model to find the unknown parameters. Moreover, the augmented vector technique was utilized to better describe the nonlinear function of the storage device. Simulation and experimental data presented the high estimation stability of the FO model to estimate the SOC of the battery. Moreover, it has adequate ability in complex environments. A multi-parameter FO model, defined using 25 parameters, was presented for analyzing the battery in [
136]. The considered battery type was lithium-ion. The combination of particle swarm optimization and the genetic algorithm was utilized to identify the parameters. Moreover, the proposed multi-domain model was defined using two domains including frequency and time. The frequency domain is based on EIS, and the time domain is based on the terminal voltage of the battery. The proposed FO model is robust and reliable for identifying and analyzing the storage device; this claim was pondered and proved by the numerical evaluations in the MATLAB environment. In [
137], a new method for estimating the state of charge of LIBs was proposed. The suggested estimation method was based on the FO and KF. The parameters of the model were identified using the adaptive genetic algorithm. During the test condition, the root mean square error of the estimation method was less than 1%. Moreover, the FO model had more stability and robustness than other KF-based techniques in estimating the SOC of the battery. The authors of [
138] proposed a hybrid method for estimating the state of charge and analyzing the ESS. This model combines the FO-equivalent model and the FO adaptive dual Kalman filter. The first part of the model is utilized to achieve the external electrical characteristics of the battery, while the second part of the proposed model estimates the battery’s charge level. The evaluation of the proposed method in different experimental conditions presented more convergence, lower error, and higher stability of the proposed FO technique than other estimation techniques. In [
22], an FO model was established to accurately estimate the state of charge and state of health of ESSs. In this second-order model, the adaptive genetic algorithm is utilized to identify the model parameters. Then, the multi-innovations unscented Kalman filter is applied to estimate the charge and health level of the battery. The performance of the estimation technique was pondered by evaluating the experimental results achieved from different cycles and operating conditions. By utilizing the proposed method, the estimation error of both SOC and SOH was lower than other methods, so its root mean square error was less than 1.2% and 0.007% in predicting the charge and health level of the battery, respectively. Thus, the proposed FO model had adequate accuracy. Another fractional-order model for estimating the SOC of the battery was introduced in [
139]. The LIBs were studied in this paper. In the proposed FO model, various temperatures and operating conditions were modeled. The model parameters were optimized by using a Krill Herd optimizer in order to obtain an appropriate model. The validation of the proposed technique was evaluated using different operating conditions, temperatures, and SOC ranges. The numerical results, which were achieved from various tests such as hybrid pulse power characteristic and dynamic stress tests, presented high accuracy and reliability of the method in different situations. This method also had lower errors than other estimation methods. The authors of [
140] proposed a multi-scale algorithm to estimate the accurate SOC of the batteries by focusing on lithium-ion technology. The estimation algorithm is based on the FO model. It was modified using the KF and variable forgetting factor recursive least squares. Indeed, the KF was used to enhance the estimation accuracy, and the variable forgetting factor algorithm was utilized to predict the internal resistance and capacity of the battery. The ant colony algorithm was utilized to extract the model parameters. The proposed model experimented with a fast variation of the SOC and a slow variation of the internal resistance of the battery. The results proved the strong power of the model in analyzing the energy storage device. The estimation error of the method was approximately 0.52%.
A new dual fractional-order model, which was extended using the KF and resistance–capacitor approximation method, was presented in [
141] for simultaneous estimation of the SOC and fractional parameters of the battery. In this technique, the Grünwald–Letnikov definition was utilized to represent the discrete state space. Moreover, both frequency and time domains were investigated in this paper. The method was validated considering different operation levels. According to the simulation results, the proposed FO model with less than 0.28% root mean square error has high accuracy in SOC estimation, and therefore, it can be utilized in real operating conditions. In [
142], a fractional-order-equivalent circuit model was suggested to analyze the battery energy system. To synchronously identify the parameters of the model and its order values, the PSO algorithm was utilized. In this study, the capability of the model was evaluated in various FO values, and therefore, the best values were selected. According to the numerical results, the proposed model has suitable performance for identifying the battery data. A robust fractional-order control method was proposed in [
143] for controlling the parameters of the supercapacitor ESS. In the first step of the proposed technique, different parameters of the storage system such as uncertainties, disturbances, nonlinearities, and dynamics were predicted by the high-gain perturbation observer. Secondly, the FO controller estimated the online compensation rate. During the observation and control cycle, the interactive teaching and learning optimizer was utilized to achieve the gains of the observer and controller. The numerical results, which were achieved from different cases and control strategies, presented the high effectiveness of the proposed method for practical applications. In [
144], an FO model was proposed to evaluate multiple groups of lithium-ion batteries with various states of health. Electrochemical impedance spectroscopy was utilized to extract the structure and parameters of the equivalent circuit model. Then, the P-type iterative learning algorithm was applied to optimize the selected parameters. To increase the reliability of the structure, the model was modified by pretest noise, correlative information criterion, and multiple correlations of parameters. The evaluation of the model considering different batteries with various states of health presented its high quality for estimating the health level and analyzing the situation of the energy storage devices. A fractional-order model was presented to evaluate the LIBs in [
145]. The presented model was modified using the Randles model, equivalent circuit model, and free non-integer differentiation orders. Moreover, multi-objective particle swarm optimization was utilized to identify the parameters of the FO model. The efficiency and stability of the suggested method were proved by evaluating the storage system against the traditional resistance capacitor circuit model. The authors of [
146] presented an FO model to estimate the charge situation of the battery in a storage management system. The LIB was the considered type of energy device for estimating. In the proposed method, the time and frequency domains were studied using the recursive least squares algorithm and recorded impedance spectroscopy, respectively. Moreover, the modified Kalman filter was used in the proposed method in order to estimate the SOC of the battery. According to the numerical evaluations, the proposed FO technique is more efficient and accurate than other methods such as the classical equivalent electric circuit.
In [
147], an FO model was presented to implement the electrochemical impedance spectroscopy in the ESS. The main focus of this study was on LIBs. In the proposed method, the capacitive resistance circuit was utilized to extract the model parameters in both offline and online modes. The numerical evaluations presented high efficiency and stability of the proposed method for closely indicating the SOC, discharge rate, and aging degree of the storage device. A new FO-based technique was investigated in [
148] to evaluate the remaining discharge time of the ESS. The LIBs and supercapacitors were studied in this paper. The combination of chaos theory and the PSO algorithm was utilized to extract the parameters of the model. Moreover, the Markov load trajectory prediction was applied to the method for increasing its accuracy. The reliability and robustness of the FO technique were proved by evaluating the method in a real operating environment. In [
149], an FO model was presented to simultaneously evaluate the ESS and the demand response program. The method was investigated in a power network in the presence of thermal power plants, biogas units, wind turbines, and photovoltaic panels. Control of the frequency parameters of the system was the main goal of introducing this FO technique. The quasi-oppositional Harris hawk algorithm was utilized to optimize the considered coefficients. The simulation of the method in real-time conditions showed its appropriate feasibility to control the indices of the system. The authors of [
150] presented another FO model for controlling the ESS in a distribution system in the presence of various energy sources such as wind turbines and PVs. In this study, the main goal of the controlling method was to stabilize the bus voltage of the system under different operation conditions. The numerical results presented that the proposed technique has more stability and reliability than other controllers such as sliding-mode control and PI control. The author of [
151] proposed a control method based on FO controllers to evaluate and control the ESS in the power network. The considered indices of the system were optimized using metaheuristic algorithms. To achieve reliable and realistic results, the proposed model was modified using the governor dead band, generation rate constraint, and communication time delay. Moreover, the sensitivity analysis was utilized to verify the performance of the method. The numerical results presented that the suggested technique has more accuracy than common controlling methods so that the mean controlling error of the fractional-order method is considerably lower than PID and PI controllers.
The utilized electrical circuit for presenting the ESS is different in various papers. In
Figure 4, the considered electrical circuits and their description are presented. In the presented circuits, different parameters such as dynamic characteristics, voltages, currents, temperatures, and storage capacities are considered and modeled using electronic devices such as resistances and capacitors and controlling blocks such as integrals and derivatives.
In the electric circuits of
Figure 4,
is the ohmic resistance.
and
show resistors that are modeled in parallel with constant phase elements. The CPE is considered to describe the charge transfer between the electrolyte interface and the double layer of the storage system. The impedance of CPE (
) can be mathematically calculated by using Equation (12).
In Equation (12), is an index similar to a capacitor, and is the Laplace operator. The parameter is the fractional order for describing the dispersion effect. It is a positive number between 0 and 1. It should be considered that the CPE behaves like the ideal capacitor when is 1, and it behaves like the resistor when is 0. The Warburg element (), which represents the diffusion process in solid phases of the low-frequency band of the storage device, is like a constant phase element.
One of the steps for applying the FO model for controlling, estimating, or evaluating the ESS is the identification of the required parameters of the proposed model. Optimization algorithms and electrochemical tests are the most used methods for identifying the model parameters in different research studies. In
Table 4, the utilized methods in various papers for selecting the required parameters of the FO models of ESSs are presented. As can be seen in this table, electrochemical tests are the most utilized method for identifying the parameters. In contrast, the PSO method is the most applied intelligent algorithm to extract the model parameters.
One of the techniques for the practical implementation of the FO model in storage systems is EIS. It is a powerful method for separating the electrochemical reactions at electrode surfaces [
152]. The measured electrochemical impedance spectra are usually divided into three parts based on the frequency. High frequency, middle frequency, and low frequency are the divided parts of the impedance spectra [
153]. In
Figure 5, the sample electrochemical impedance spectra of the two most utilized types of ESSs, lithium-ion batteries and liquid metal batteries, are demonstrated [
119,
120,
121,
122,
123]. In the FO method, the impedance spectra are utilized to model the dynamics between the electrodes of the storage system in different operating situations.
The estimation of the battery’s parameters such as the SOC during real operation of the power network and also EV operation is a major and complex challenge due to the nonlinear properties of the storage systems. The FO technique is useful for analyzing and achieving the proper parameters. The FO models have unique advantages and more accuracy compared with the conventional electrochemical models and equivalent circuit models [
120]. The fractional-order technique has been utilized to estimate the state of charge of ESSs used in EVs and MGs. In [
122], the estimation power of the FO model was compared with the real-time data and the extended Kalman filter method.
Figure 6 shows the SOC of the battery considering different estimation methods and the actual data. According to the results, the maximum estimation error of the FO method is 1.50%, while the maximum estimation error of the extended Kalman filter is 5.11%. Therefore, the fractional-order model reduces the estimation error by up to 71% [
122].
In another study, experimental evaluations proved that the FO method has high stability and proper adaptability so that it appropriately identifies the electrochemical dynamics of the ESS with a 0.86% maximum relative absolute error [
125].
The estimation error of the voltage of the ESS during the operation considering two methods is shown in
Figure 7. As can be seen in this figure, the voltage estimation error of the FO model is lower than that of the integer-order model. The error rate of the fractional-order method is about 0.13%, while the estimation voltage of the integer-order method has an error of approximately 0.16%. Therefore, the fractional-order technique has more accuracy in estimating the voltage of the energy storage system [
128].
The FO method also has more effectiveness and stability in controlling the nonlinear and uncertain parameters of the ESS. According to the numerical evaluations, the error rate of the fractional-order-based technique is 8.79%. At the same time, the feedback linearization control, the proportional integral derivative control, and the sliding-mode control have 31.86%, 14.54%, and 11.31% error rates, respectively. Thus, the FO method has more stability and efficiency than other methods [
129].
In another study, the performance of the fractional-order method in estimating the SOC of the ESS was compared with the KF [
137]. Experimental results presented that the average error of the Kalman filter is 0.73%, while the average error of the fractional-order model is 0.55%. Therefore, the estimated SOC by the fractional-order method has approximately 25% more accuracy than the result obtained by using the KF [
137].
The fractional-order methods have more stability than other methods in controlling systems.
Table 5 presents the details of the energy system after applying a fault considering FOPID, TID, and PID controllers. In this table, the settling time (ST), the peak time (PT), the magnitude of the peak (MP), the integral of squared error (ISE), and the integral of time-multiplied absolute error (ITMAE) of the energy system after applying a fault to the system are given. As can be shown in this table, the FOPID method is about 31% faster than PID and TID controllers in controlling any disturbance in the system. Moreover, it has 33–50% and 45–57% lower ISE and ITMAE than classical controllers, respectively. The numerical results show that the fractional-order controller has more stability and lower error than other ones [
151].