In Vitro Effect of Drilling Speed on the Primary Stability of Narrow Diameter Implants with Varying Thread Designs Placed in Different Qualities of Simulated Bone
Abstract
:1. Introduction
2. Methods
2.1. Surgical Protocol
2.2. Evaluation of Primary Stability
2.3. Statistical Analysis
3. Results
3.1. Implant Stability Quotient Values for Implants Placed in Dense Bone at 800 and 2000 PRM
3.2. Implant Stability Quotient Values for Implants Placed in Soft Bone at 800 and 2000 PRM
4. Discussion
5. Conclusions
Author Contributions
Acknowledgments
Conflicts of Interest
References
- Romanos, G.E. Present status of immediate loading of oral implants. J. Oral. Implantol. 2004, 30, 189–197. [Google Scholar] [CrossRef]
- Kashi, A.; Gupta, B.; Malmstrom, H.; Romanos, G.E. Primary stability of implants placed at different angulations in artificial bone. Implant. Dent. 2015, 24, 92–95. [Google Scholar] [CrossRef] [PubMed]
- Almeida, K.P.; Delgado-Ruiz, R.; Carneiro, L.G.; Leiva, A.B.; Calvo-Guirado, J.L.; Gomez-Moreno, G.; Malmström, H.; Romanos, G.E. Influence of Drilling Speed on Stability of Tapered Dental Implants: An Ex Vivo Experimental Study. Int. J. Oral Maxillofac. Implant. 2016, 31, 795–798. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Javed, F.; Ahmed, H.B.; Crespi, R.; Romanos, G.E. Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation. Interv. Med. Appl. Sci. 2013, 5, 162–167. [Google Scholar] [CrossRef] [PubMed]
- Javed, F.; Romanos, G.E. Role of implant diameter on long-term survival of dental implants placed in posterior maxilla: A systematic review. Clin. Oral Investig. 2015, 19, 1–10. [Google Scholar] [CrossRef] [PubMed]
- Javed, F.; Romanos, G.E. The role of primary stability for successful immediate loading of dental implants. A literature review. J. Dent. 2010, 38, 612–620. [Google Scholar] [PubMed]
- Herrmann, I.; Lekholm, U.; Holm, S.; Kultje, C. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. Int. J. Oral Maxillofac. Implant. 2005, 20, 220–230. [Google Scholar]
- Kotze, M.J.; Butow, K.W.; Olorunju, S.A.; Kotze, H.F. A comparison of mandibular and maxillary alveolar osteogenesis over six weeks: A radiological examination. Head Face Med. 2014, 10, 50. [Google Scholar] [CrossRef] [PubMed]
- Koo, K.T.; Wikesjo, U.M.; Park, J.Y.; Kim, T.I.; Seol, Y.J.; Ku, Y.; Rhyu, I.C.; Chung, C.P.; Lee, Y.M. Evaluation of single-tooth implants in the second molar region: A 5-year life-table analysis of a retrospective study. J. Periodontol. 2010, 81, 1242–1249. [Google Scholar] [CrossRef] [PubMed]
- Carvalho, A.C.; Queiroz, T.P.; Okamoto, R.; Margonar, R.; Garcia, I.R.; Magro Filho, O. Evaluation of bone heating, immediate bone cell viability, and wear of high-resistance drills after the creation of implant osteotomies in rabbit tibias. Int. J. Oral Maxillofac. Implant 2011, 26, 1193–1201. [Google Scholar]
- Marcello-Machado, R.M.; Faot, F.; Schuster, A.J.; Bielemann, A.M.; Chagas Junior, O.L.; Del Bel Cury, A.A. One-year clinical outcomes of locking taper Equator attachments retaining mandibular overdentures to narrow diameter implants. Clin. Implant Dent. Relat. Res. 2018, 20, 483–492. [Google Scholar] [CrossRef] [PubMed]
- Mazor, Z.; Lorean, A.; Mijiritsky, E.; Levin, L. Replacement of a molar with 2 narrow diameter dental implants. Implant Dent. 2012, 21, 36–38. [Google Scholar] [CrossRef] [PubMed]
- Kolinski, M.; Hess, P.; Leziy, S.; Friberg, B.; Bellucci, G.; Trisciuoglio, D.; Wagner, W.; Moergel, M.; Pozzi, A.; Wiltfang, J.; et al. Immediate provisionalization in the esthetic zone: 1-year interim results from a prospective single-cohort multicenter study evaluating 3.0-mm-diameter tapered implants. Clin. Oral Investig. 2018, 22, 2299–2308. [Google Scholar] [CrossRef] [PubMed]
- Marcello-Machado, R.M.; Faot, F.; Schuster, A.J.; Nascimento, G.G.; Del Bel Cury, A.A. Mini-implants and narrow diameter implants as mandibular overdenture retainers: A systematic review and meta-analysis of clinical and radiographic outcomes. J. Oral Rehabil. 2018, 45, 161–183. [Google Scholar] [CrossRef] [PubMed]
- Froum, S.J.; Shi, Y.; Fisselier, F.; Cho, S.C. Long-term retrospective evaluation of success of narrow-diameter implants in the esthetic areas: A consecutive case series with 3 to 14 years follow-up. Int. J. Periodontics Restor. Dent. 2017, 37, 629–637. [Google Scholar] [CrossRef] [PubMed]
- Reissmann, D.R.; Enkling, N.; Moazzin, R.; Haueter, M.; Worni, A.; Schimmel, M. Long-term changes in oral health-related quality of life over a period of 5 years in patients treated with narrow diameter implants: A prospective clinical study. J. Dent. 2018, 75, 84–90. [Google Scholar] [CrossRef] [PubMed]
- De Souza, A.B.; Sukekava, F.; Tolentino, L.; César-Neto, J.B.; Garcez-Filho, J.; Araújo, M.G. Narrow- and regular-diameter implants in the posterior region of the jaws to support single crowns: A 3-year split-mouth randomized clinical trial. Clin. Oral Implant. Res. 2018, 29, 100–107. [Google Scholar] [CrossRef] [PubMed]
- Parize, H.N.; Bohner, L.O.L.; Gama, L.T.; Porporatti, A.L.; Mezzomo, L.A.M.; Martin, W.C.; Vega Gonçalves, T.M.S. Narrow-diameter implants in the anterior region: A meta-analysis. Int. J. Oral Maxillofac. Implant. 2019. [Google Scholar] [CrossRef] [PubMed]
- Schiegnitz, E.; Al-Nawas, B. Narrow-diameter implants: A systematic review and meta-analysis. Clin. Oral Implant. Res. 2018, 29, 21–40. [Google Scholar] [CrossRef] [PubMed]
Drilling Speed | ISQ Values in Dense Artificial Bone | ISQ Values in Soft Artificial Bone | ||||
---|---|---|---|---|---|---|
Group A | Group B | Group C | Group A | Group B | Group C | |
800 RPM | 66.8 ± 3.3 | 67.3 ± 2.6 | 67.1 ± 2.0 * | 59.9 ± 2.0 † | 64.4 ± 2.9 | 57.9 ± 4.6 |
2000 RPM | 65.9 ± 4.2 | 66.8 ± 4.8 | 63.8 ± 3.1 | 63.3 ± 1.6 | 61.2 ± 3.0 | 59.1 ± 2.0 |
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Romanos, G.E.; Bastardi, D.J.; Moore, R.; Kakar, A.; Herin, Y.; Delgado-Ruiz, R.A. In Vitro Effect of Drilling Speed on the Primary Stability of Narrow Diameter Implants with Varying Thread Designs Placed in Different Qualities of Simulated Bone. Materials 2019, 12, 1350. https://doi.org/10.3390/ma12081350
Romanos GE, Bastardi DJ, Moore R, Kakar A, Herin Y, Delgado-Ruiz RA. In Vitro Effect of Drilling Speed on the Primary Stability of Narrow Diameter Implants with Varying Thread Designs Placed in Different Qualities of Simulated Bone. Materials. 2019; 12(8):1350. https://doi.org/10.3390/ma12081350
Chicago/Turabian StyleRomanos, Georgios E., Daniel J. Bastardi, Rachel Moore, Apoorv Kakar, Yaro Herin, and Rafael A. Delgado-Ruiz. 2019. "In Vitro Effect of Drilling Speed on the Primary Stability of Narrow Diameter Implants with Varying Thread Designs Placed in Different Qualities of Simulated Bone" Materials 12, no. 8: 1350. https://doi.org/10.3390/ma12081350
APA StyleRomanos, G. E., Bastardi, D. J., Moore, R., Kakar, A., Herin, Y., & Delgado-Ruiz, R. A. (2019). In Vitro Effect of Drilling Speed on the Primary Stability of Narrow Diameter Implants with Varying Thread Designs Placed in Different Qualities of Simulated Bone. Materials, 12(8), 1350. https://doi.org/10.3390/ma12081350