Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (99)

Search Parameters:
Keywords = carbon fiber-reinforced polymer bars

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 2443 KB  
Article
Durability of Concrete Reinforced with GFRP Bars Under Varying Alkalinity and Temperature Conditions
by Ruan Carlos de Araújo Moura, Daniel Véras Ribeiro and Paulo Roberto Lopes Lima
Buildings 2025, 15(16), 2832; https://doi.org/10.3390/buildings15162832 - 9 Aug 2025
Viewed by 456
Abstract
The application of glass fiber reinforced polymer (GFRP) bars offers a promising solution for enhancing the durability of reinforced concrete structures, potentially reducing maintenance costs and associated socioeconomic impacts. However, concerns persist regarding the durability of GFRP bars in the highly alkaline environment [...] Read more.
The application of glass fiber reinforced polymer (GFRP) bars offers a promising solution for enhancing the durability of reinforced concrete structures, potentially reducing maintenance costs and associated socioeconomic impacts. However, concerns persist regarding the durability of GFRP bars in the highly alkaline environment of concrete, which can lead to physical, chemical, and mechanical degradation. This study evaluates the durability of GFRP bars composed of isophthalic polyester, vinyl ester, and epoxy matrices (6.0 mm diameter) under accelerated aging conditions. The bars were exposed to non-carbonated concrete (with and without silica fume) and carbonated concrete at temperatures of 23 °C, 40 °C, and 60 °C for durations of 500, 1000, and 3000 h. Interlaminar shear strength (ISS) was measured before and after aging. SEM and FTIR analyses confirmed degradation in the polymer matrix and fiber–matrix interface. Results indicated that silica fume significantly mitigated alkalinity effects, limiting ISS loss to 11.3%. Similarly, carbonation reduced the concrete’s pH, thereby decreasing ISS degradation to 10.7% after 3000 h. Among the tested materials, GFRP bars with vinyl ester matrix exhibited superior durability, followed by those with epoxy and polyester matrices. These findings emphasize the critical role of matrix selection and concrete mix design in improving GFRP durability. Full article
(This article belongs to the Special Issue Research on the Durability of Reinforced Concrete Structures)
Show Figures

Figure 1

18 pages, 5101 KB  
Article
Investigation of the Preparation and Interlayer Properties of Multi-Walled Carbon Nanotube-Reinforced Ultra-Thin TA1/CFRP Laminates
by Quanda Zhang, Zhongxiao Zhang, Jiahua Cao, Yao Wang and Zhiying Sun
Metals 2025, 15(7), 765; https://doi.org/10.3390/met15070765 - 7 Jul 2025
Viewed by 265
Abstract
Titanium alloy/carbon fiber-reinforced polymer (TA1/CFRP) laminates, representing the latest fourth generation of fiber metal laminates (FMLs), is a kind of high-performance composite material. However, the fragility of the fiber/resin and metal/resin interface layers in these composites directly impacts their mechanical properties. To enhance [...] Read more.
Titanium alloy/carbon fiber-reinforced polymer (TA1/CFRP) laminates, representing the latest fourth generation of fiber metal laminates (FMLs), is a kind of high-performance composite material. However, the fragility of the fiber/resin and metal/resin interface layers in these composites directly impacts their mechanical properties. To enhance these properties, this paper investigates the preparation process of multi-walled carbon nanotube (MWCNT)-reinforced ultra-thin TA1/CFRP laminates and explores the impact of MWCNT content on the interlayer properties of these ultra-thin TA1/CFRP laminates. Initially, the challenge of dispersing carbon nanotubes using ultrasonic dispersion devices and dispersants was addressed. Vacuum-curing pressure studies revealed minimal overflow at 0.8 bar vacuum. Subsequently, the impact of MWCNT content on interlayer properties was investigated. The results indicated a significant increase in interlayer shear strength and interlayer fracture toughness with MWCNT additions at 0.5 wt% and 0.75 wt%, whereas the interlayer properties decreased at 1.0 wt% MWCNT. Fracture morphology analysis revealed that MWCNT content exceeding 0.75 wt% led to agglomeration, resulting in resin cavity formation and stress concentration. Full article
Show Figures

Figure 1

29 pages, 14072 KB  
Article
Performance Assessment of Fire-Damaged and CFRP-Repaired Bridge Columns Under Single Unit Truck Impact and Blast
by Qusai A. Alomari and Daniel G. Linzell
Fire 2025, 8(6), 227; https://doi.org/10.3390/fire8060227 - 9 Jun 2025
Viewed by 2037
Abstract
Recent catastrophic bridge fire incidents have highlighted the critical need for effective post-fire assessment of bridges, thereby challenging the dominant practice of complete replacement following these destructive events. This study investigates the post-fire performance of bare, isolated, and Carbon Fiber Reinforced Polymer (CFRP)-repaired [...] Read more.
Recent catastrophic bridge fire incidents have highlighted the critical need for effective post-fire assessment of bridges, thereby challenging the dominant practice of complete replacement following these destructive events. This study investigates the post-fire performance of bare, isolated, and Carbon Fiber Reinforced Polymer (CFRP)-repaired Reinforced Concrete (RC) bridge columns under single-unit truck impact followed by air blast. This extreme loading scenario was deliberately selected given the increased vulnerability of bridge columns to this loading scenario in the recent few years. Three-dimensional Finite Element (FE) models of the structural system and surrounding environment were developed and validated in LS-DYNA. The effectiveness of two in-situ retrofitting schemes in mitigating damage and enhancing structural integrity of three column diameters under the selected multi-hazards was assessed. Results demonstrated that wrapping the bottom half of the column height prevents shear failure and significantly reduces the damage under the coupled impact and blast. In contrast, employing a combination of CFRP bars and externally bonded sheets showed limited enhancement on post-fire impact and blast performance. This study provides critical insights into the feasibility and efficacy of retrofitting bridge columns that have experienced fire, thus laying the groundwork for the reconsideration of current design and rehabilitation protocols. Full article
Show Figures

Figure 1

37 pages, 9814 KB  
Article
Experimental Investigation of CFRP High-Strength Concrete Beams Incorporating Recycled Concrete Aggregate
by Gharbi Mohammed Shareef Saadi, Mereen Hassan Fahmi Rasheed and Ayad Zeki Saber Agha
Buildings 2025, 15(9), 1418; https://doi.org/10.3390/buildings15091418 - 23 Apr 2025
Viewed by 686
Abstract
This research investigates the structural behavior of high-strength concrete beams reinforced with carbon fiber-reinforced polymer (CFRP) bars and varying percentages of recycled concrete aggregate (RCA). The study examined 15 reinforced concrete beams (200 × 250 × 2000 mm) constructed with different RCA proportions [...] Read more.
This research investigates the structural behavior of high-strength concrete beams reinforced with carbon fiber-reinforced polymer (CFRP) bars and varying percentages of recycled concrete aggregate (RCA). The study examined 15 reinforced concrete beams (200 × 250 × 2000 mm) constructed with different RCA proportions (0%, 25%, 50%, 75%, and 100%) and tested at three shear span-to-depth ratios (a/d = 1.5, 2.5, and 3.5), addressing a critical knowledge gap in sustainable structural engineering. Specimens exhibited compressive strengths of 55–67 MPa and reached ultimate load capacities of up to 198.4 kN. Notably, beams with 75% RCA achieved 35.7% higher capacity than control specimens at a/d = 1.5, challenging conventional expectations about RCA performance. Failure modes transitioned from shear-dominated at a/d = 1.5 to flexure-dominated at a/d = 3.5, with optimal ductility indices (up to 2.75) observed at a/d = 2.5. Statistical analysis revealed significant correlations between a/d ratio and performance metrics, with a perfect parabolic relationship for the ductility index (R2 = 1.0, p<0.001). Comparison with ACI 440.1R15 predictions showed generally conservative estimates (mean experimental-to-predicted ratio = 1.02, COV = 16.9%). The findings demonstrate that high-strength concrete can successfully incorporate substantial RCA quantities (up to 75%) without compromising performance when using CFRP reinforcement, potentially reducing virgin material consumption by approximately 33% for sustainable construction applications. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

18 pages, 20703 KB  
Article
Performance Evaluation of Reinforced Concrete Beams with Corroded Rebar Strengthened by Carbon Fiber-Reinforced Polymer
by Sangwoo Kim, Wonchang Choi and Jinsup Kim
Polymers 2025, 17(8), 1021; https://doi.org/10.3390/polym17081021 - 10 Apr 2025
Cited by 2 | Viewed by 893
Abstract
The inefficiency of unreinforced concrete beams as flexural members poses a challenge because concrete’s tensile strength is significantly lower than its compressive strength. In response to this challenge, reinforcement bars are commonly employed near the tension zone of reinforced concrete (RC) beams. Nonetheless, [...] Read more.
The inefficiency of unreinforced concrete beams as flexural members poses a challenge because concrete’s tensile strength is significantly lower than its compressive strength. In response to this challenge, reinforcement bars are commonly employed near the tension zone of reinforced concrete (RC) beams. Nonetheless, structures constructed with RC face challenges such as reduced live load capacity, concrete deterioration, and the corrosion of reinforcement bars over time. To address this, ongoing research is exploring maintenance and retrofitting techniques using high-strength, lightweight fiber-reinforced polymer (FRP) composite materials such as carbon fiber-reinforced polymer (CFRP) and glass fiber-reinforced polymer (GFRP). In this study, the flexural performance of corroded RC beams was enhanced through retrofitting with CFRP plates and sheets. The corroded RC beams were fabricated using an applied-current method with a 5% NaCl solution to induce a 10% target corrosion level under controlled laboratory conditions. Flexural tests were conducted to evaluate the structural performance, failure modes, load–displacement relationships, and energy dissipation capacities. The results showed that CFRP reinforcement mitigates the adverse effects of corrosion-induced reduction in rebar cross-sectional areas, leading to increased stiffness and improved load-carrying capacity. In particular, CFRP reinforcement increased the yield load by up to 36.5% and the peak load by up to 90% in corroded specimens. The accumulated energy dissipation capacity also increased by 92%. These enhancements are attributed to the effective load-sharing behavior between the corroded rebar and the CFRP reinforcement. Full article
Show Figures

Figure 1

23 pages, 10176 KB  
Article
Experimental Study on Bond Fatigue Between Carbon Fiber-Reinforced Polymer Bars and Seawater–Sea Sand Concrete Under Seawater Immersion and Dry–Wet Cycle Conditions
by Fu Yang, Weiquan Gan, Bingsan Chen, Jiangchuan Wu and Shiwen Yuan
Buildings 2025, 15(3), 438; https://doi.org/10.3390/buildings15030438 - 30 Jan 2025
Cited by 1 | Viewed by 1092
Abstract
The durability of carbon fiber-reinforced polymer (CFRP) bars in marine environments is essential for their application in seawater–sea sand concrete (SWSSC), especially under cyclic loading conditions. While previous studies primarily focused on static bonding performance, the effects of seawater immersion and dry–wet cycles [...] Read more.
The durability of carbon fiber-reinforced polymer (CFRP) bars in marine environments is essential for their application in seawater–sea sand concrete (SWSSC), especially under cyclic loading conditions. While previous studies primarily focused on static bonding performance, the effects of seawater immersion and dry–wet cycles on bond fatigue behavior at CFRP–SWSSC interfaces remain underexplored. This study investigated the bond fatigue performance of CFRP bars and SWSSC under seawater immersion and dry–wet cycling conditions. Eighteen CFRP bar-SWSSC bond specimens were divided into three categories and prepared for static and fatigue pull-out tests. The effects of varying stress levels (fatigue upper load/static bond ultimate load) after seawater immersion and dry–wet cycling on fatigue failure modes, bond–slip behavior, and fatigue characteristics were evaluated. The results show that seawater immersion and dry–wet cycling significantly degrade the performance of bonds between CFRP bars and SWSSC, with an average bond strength reduction of 10.31%. These conditions reduce fatigue cycles and stiffness while increasing bond–slip (relative displacement at the bar–concrete interface) and residual–slip (displacement after unloading). Moreover, dry–wet cycling has a greater negative impact on fatigue bond performance than seawater immersion. Higher fatigue stress levels exacerbate damage and crack propagation at the CFRP–SWSSC interface, leading to significant increases in both bond–slip and residual-slip. Under similar conditions, higher stress levels enhance bond stiffness. However, excessively high stresses may lead to bond fatigue failures. Using experimental data and existing fatigue bond–slip constitutive models, a customized model for CFRP bars in SWSSC was developed. These findings highlight that marine environments and fatigue loading severely impair bond performance, thereby emphasizing the importance of careful design for marine applications. The proposed model offers a reliable framework for predicting bond–slip behavior under fatigue conditions, enhancing the understanding of CFRP–SWSSC interactions and supporting the design of durable marine infrastructure. Full article
Show Figures

Figure 1

23 pages, 12763 KB  
Article
Bond Performance of GFRP Bars in Glass and Basalt Fiber-Reinforced Geopolymer Concrete Under Hinged Beam Tests
by Duygu Ertürkmen, Hüsamettin Ürünveren, Ahmet Beycioğlu, Nabi Ibadov, Hüseyin Yılmaz Aruntaş and Andrzej Garbacz
Materials 2025, 18(3), 498; https://doi.org/10.3390/ma18030498 - 22 Jan 2025
Cited by 3 | Viewed by 1190
Abstract
In recent years, researchers have focused on the usability of fiber-reinforced polymer (FRP) bars due to their lightweight, corrosion-resistant, and eco-friendly characteristics. Geopolymers, as low-carbon alternatives to traditional binders, aim to reduce CO2 emissions in concrete production. The bond strength between FRP [...] Read more.
In recent years, researchers have focused on the usability of fiber-reinforced polymer (FRP) bars due to their lightweight, corrosion-resistant, and eco-friendly characteristics. Geopolymers, as low-carbon alternatives to traditional binders, aim to reduce CO2 emissions in concrete production. The bond strength between FRP bars and concrete is critical for the load-bearing capacity and deformation characteristics of reinforced elements. The objectives of this work are to investigate the bond performance of GFRP bars in chopped glass and basalt fiber-added geopolymer concrete using hinged beam tests. Since the hinged beam test accurately represents the behavior of real bending elements, this test method was selected as a main bonding test. Initially, three geopolymer mixtures with Ms modulus values of 1.2, 1.3, and 1.4 were prepared and tested. The mixture with a modulus of 1.2 Ms, achieving a compressive strength of 56.53 MPa, a flexural strength of 3.54 MPa, and a flow diameter of 57 cm, was chosen for beam production due to its optimal workability and strength. After mechanical and workability tests, SEM analysis was performed to evaluate its internal structure. For evaluating the bond performance of GFRP bars, 12 geopolymer beam specimens were prepared, incorporating varying fiber types (chopped glass fiber or basalt fiber) and embedment lengths (5 Ø or 20 Ø). Hinged beam tests revealed that the bond strengths of glass and basalt fiber-added mixtures were up to 49% and 37% higher than that of the control geopolymer concrete, respectively. It was concluded that incorporating fibers positively influenced the bond between geopolymer concrete and GFRP bars, with glass fibers proving more effective than basalt fibers. These findings enhance the understanding of bond mechanisms between GFRP bars and geopolymer concrete, emphasizing their potential for sustainable and durable construction in both industrial and scientific applications. Full article
Show Figures

Figure 1

29 pages, 7068 KB  
Review
A Review on Research Advances and Applications of Basalt Fiber-Reinforced Polymer in the Construction Industry
by Sheng-Jie Duan, Ru-Ming Feng, Xin-Yan Yuan, Liang-Tao Song, Gen-Shu Tong and Jing-Zhong Tong
Buildings 2025, 15(2), 181; https://doi.org/10.3390/buildings15020181 - 9 Jan 2025
Cited by 2 | Viewed by 2919
Abstract
Compared to glass fiber-reinforced polymer (GFRP) and carbon fiber-reinforced polymer (CFRP), basalt fiber-reinforced polymer (BFRP) offers distinct advantages, including the relatively lower cost and superior creep resistance. As a result, its application in the construction industry has been gaining growing attention. This paper [...] Read more.
Compared to glass fiber-reinforced polymer (GFRP) and carbon fiber-reinforced polymer (CFRP), basalt fiber-reinforced polymer (BFRP) offers distinct advantages, including the relatively lower cost and superior creep resistance. As a result, its application in the construction industry has been gaining growing attention. This paper begins by providing an overview of the fundamental background, as well as the mechanical and microscopic properties, of BFs. By exploring various application types, including one-dimensional (e.g., bars, cables), two-dimensional (e.g., grids, sheets), and three-dimensional (e.g., profiles) applications, the research progress of BFRP products in the construction industry is comprehensively summarized. Research has demonstrated the effectiveness of BFRP in a variety of structural applications, such as reinforcing existing structures (e.g., concrete or masonry) using BFRP bars, grids, or sheets, and the development of novel design concepts that integrate BFRP products with existing structural systems. Furthermore, this paper identifies unresolved challenges and proposes potential research directions, intending to promote BFRP’s broader adoption as a standardized and innovative material in the construction industry. Full article
Show Figures

Figure 1

20 pages, 4196 KB  
Article
In Situ Polymerization and Synthesis of UHMWPE/Carbon Fiber Composites
by Elena Fedorenko and Gerrit A. Luinstra
Polymers 2025, 17(1), 90; https://doi.org/10.3390/polym17010090 - 1 Jan 2025
Cited by 1 | Viewed by 1722
Abstract
Carbon-fiber-reinforced composites of ultra-high-molecular-weight polyethylene (UHMWPE) are not easily prepared because of their high viscosity, although they can be advantageous in advanced engineering applications due to their superior mechanical properties in combination with their low specific weight and versatility. Short polyacrylonitrile-based carbon-fiber-reinforced UHMWPE [...] Read more.
Carbon-fiber-reinforced composites of ultra-high-molecular-weight polyethylene (UHMWPE) are not easily prepared because of their high viscosity, although they can be advantageous in advanced engineering applications due to their superior mechanical properties in combination with their low specific weight and versatility. Short polyacrylonitrile-based carbon-fiber-reinforced UHMWPE composites with fiber contents of 5, 10, and 15 wt.% could easily be prepared using in situ ethylene polymerization. Therefore, MgCl2 was generated at the Brønsted acidic groups of the fiber surface by employing a reaction between the co-catalysts Mg(C4H9)2 and AlEt2Cl. Titanation with TiCl4 resulted in a catalyst directly on the fiber surface. The catalyst polymerized ethylene (2 bar pressure at 50 °C), forming a UHMWPE matrix near the surface; its fragmentation led to polymer particles associated with the fiber. The catalyst activity on the fiber surface of untreated (CF-Pr, 3.48 ± 0.24 wt.%) and oxidized fibers (CF-Ox, 7.41 ± 0.03 wt.%) was 20% lower. CF-Pr compression-molded samples showed tensile strengths of up to 50.4 ± 1.3 MPa, while CF-Ox samples reached 39.1 ± 0.6 MPa, surpassing the performance of composites prepared by melt compounding. The stiffness of 1.58 ± 0.17 GPa for a melt-compounded material was lower than the 3.24 ± 0.10 GPa for CF-Pr and 2.19 ± 0.07 GPa for CF-Ox composites. A fracture examination showed fiber pull-outs, matrix residues on the fibers, and the formation of some extensional polymer fibrils. The latter explains the higher stress at yield and the breakage of the CF-Pr based composites in particular. The potential of in situ polymerized UHMWPE composites for the utilization in high-performance structural applications is thus demonstrated. Full article
(This article belongs to the Section Polymer Composites and Nanocomposites)
Show Figures

Figure 1

28 pages, 10795 KB  
Article
Advanced Structural Technologies Implementation in Designing and Constructing RC Elements with C-FRP Bars, Protected Through SHM Assessment
by Georgia M. Angeli, Maria C. Naoum, Nikos A. Papadopoulos, Parthena-Maria K. Kosmidou, George M. Sapidis, Chris G. Karayannis and Constantin E. Chalioris
Fibers 2024, 12(12), 108; https://doi.org/10.3390/fib12120108 - 5 Dec 2024
Cited by 1 | Viewed by 1366
Abstract
The need to strengthen the existing reinforced concrete (RC) elements is becoming increasingly crucial for modern cities as they strive to develop resilient and sustainable structures and infrastructures. In recent years, various solutions have been proposed to limit the undesirable effects of corrosion [...] Read more.
The need to strengthen the existing reinforced concrete (RC) elements is becoming increasingly crucial for modern cities as they strive to develop resilient and sustainable structures and infrastructures. In recent years, various solutions have been proposed to limit the undesirable effects of corrosion in RC elements. While C-FRP has shown promise in corrosion-prone environments, its use in structural applications is limited by cost, bonding, and anchorage challenges with concrete. To address these, the present research investigates the structural performance of RC beams reinforced with C-FRP bars under static loading using Structural Health Monitoring (SHM) with an Electro-Mechanical Impedance (EMI) system employing Lead Zirconate Titanate (PZT) piezoelectric transducers which are applied to detect damage development and enhance the protection of RC elements and overall, RC structures. This study underscores the potential of C-FRP bars for durable tensile reinforcement in RC structures, particularly in hybrid designs that leverage steel for compression strength. The study focuses on critical factors such as stiffness, maximum load capacity, deflection at each loading stage, and the development of crack widths, all analyzed through voltage responses recorded by the PZT sensors. Particular emphasis is placed on the bond conditions and anchorage lengths of the tensile C-FRP bars, exploring how local confinement conditions along the anchorage length influence the overall behavior of the beams. Full article
Show Figures

Figure 1

23 pages, 6148 KB  
Article
An Analysis of the Flexural Stiffness and Horizontal Bearing Capacity of CFRP Composite Pipe Piles in Marine Environments
by Wei Zhang, Wei Shao and Yinghui Nie
J. Mar. Sci. Eng. 2024, 12(10), 1870; https://doi.org/10.3390/jmse12101870 - 18 Oct 2024
Cited by 1 | Viewed by 1274
Abstract
Carbon-fiber-reinforced polymer (CFRP) is a composite material consisting of a resin matrix reinforced with carbon fibers. This study focuses on CFRP composite pipe piles as the subject of investigation, exploring the impact of substituting steel bars with CFRP bars on the bending performance [...] Read more.
Carbon-fiber-reinforced polymer (CFRP) is a composite material consisting of a resin matrix reinforced with carbon fibers. This study focuses on CFRP composite pipe piles as the subject of investigation, exploring the impact of substituting steel bars with CFRP bars on the bending performance of pipe piles through rigorous three-point bending tests. The attenuation of flexural stiffness in CFRP pipe piles under a chloride salt environment was anticipated. The lateral bearing capacity of CFRP pipe piles was calculated by introducing a stiffness degradation coefficient for the piles and utilizing the finite difference method. The findings of the analysis suggest that as the CFRP reinforcement replacement rate increases, the initial bending stiffness of the composite pipe pile experiences a corresponding decrease. After serving for 28.15 years, the steel reinforcement within the pipe pile commences rusting, resulting in a nonlinear decline in the bending stiffness of the composite pipe pile. As the service time of pipe piles increases, a higher replacement rate of CFRP reinforcement results in a slower attenuation of pile stiffness. Consequently, both the horizontal displacement at the top of the pile and the bending moment along the body of the composite pipe pile gradually increase over time. During the same service period, the higher the rate of CFRP reinforcement, the less noticeable the attenuation in the horizontal bearing capacity of the pile shaft. Full article
(This article belongs to the Section Ocean Engineering)
Show Figures

Figure 1

20 pages, 8190 KB  
Article
Evaluation of Peripheral Milling and Abrasive Water Jet Cutting in CFRP Manufacturing: Analysis of Defects and Surface Quality
by Alejandro Sambruno, Álvaro Gómez-Parra, Pablo Márquez, Iñaki Tellaeche-Herrera and Moisés Batista
Fibers 2024, 12(10), 78; https://doi.org/10.3390/fib12100078 - 25 Sep 2024
Cited by 2 | Viewed by 1626
Abstract
The use of carbon fiber reinforced polymers (CFRP) is crucial in industries, such as aerospace, automotive, and marine, due to their excellent strength-to-weight ratio and corrosion resistance. However, machining CFRP is challenging due to its abrasive nature, which can cause premature tool wear. [...] Read more.
The use of carbon fiber reinforced polymers (CFRP) is crucial in industries, such as aerospace, automotive, and marine, due to their excellent strength-to-weight ratio and corrosion resistance. However, machining CFRP is challenging due to its abrasive nature, which can cause premature tool wear. Some of the commonly used processes for machining these materials are dry milling and abrasive water jet machining (AWJM), which offer the best alternatives from an environmental point of view. This article presents an analysis of the defects and surface quality obtained in CFRP after machining by AWJM and milling. For this purpose, combinations of relevant parameters have been chosen for each process: cutting speed and tool wear in milling and traverse feed rate and hydraulic pressure in AWJM. The results obtained have been evaluated from two points of view: macroscopically, through the evaluation of delamination, and microscopically, through the study of the roughness in terms of Ra. Furthermore, a discussion on functional, environmental, economic, and social terms has been made between both processes. In summary, each machining process generates a specific type of delamination: Type II in milling and Type I in AWJM. In addition, the best Ra results are obtained for pressures of 1200 bar in AWJM. Full article
(This article belongs to the Collection Feature Papers in Fibers)
Show Figures

Figure 1

36 pages, 17089 KB  
Article
Structural Behavior of Full-Scale Novel Hybrid Layered Concrete Slabs Reinforced with CFRP and Steel Grids under Impact Load
by Ahmed Abbas Ghali Abu Altemen, Mu’taz Kadhim Medhlom and Mustafa Özakça
Buildings 2024, 14(9), 2625; https://doi.org/10.3390/buildings14092625 - 24 Aug 2024
Cited by 2 | Viewed by 1414
Abstract
Reinforced concrete two-way slabs are important elements in the construction field, and their impact response under drop-weight impact is a complex mechanical issue that can cause the collapse of heavy structures. Previous research has documented the analysis of conventional steel-reinforced concrete slabs under [...] Read more.
Reinforced concrete two-way slabs are important elements in the construction field, and their impact response under drop-weight impact is a complex mechanical issue that can cause the collapse of heavy structures. Previous research has documented the analysis of conventional steel-reinforced concrete slabs under impact loads. However, the investigation of layered hybrid concrete composite flat solid slabs reinforced with carbon-fiber-reinforced polymer (CFRP) rebars is an innovative subject. This paper examines the structural behavior of layered novel hybrid concrete composite flat solid slabs with a combination of reactive powder concrete (RPC) in the top layer and normal concrete (NC) in the bottom layer, reinforced with internal CFRP or traditional steel bars in the tension zone, under an impact load test. For this purpose, ten full-scale square flat solid slab samples with a 1550 mm length and a 150 mm depth were fabricated and divided into eight layered hybrid concrete samples with 50% RPC and 50% NC and two samples cast with NC only. The impact tests were carried out using a hardened steel cylindroconical impactor (projectile) with a height of 650 mm and a diameter of 200 mm, a flat nose diameter of 90 mm, and a total mass of 150 kg released from two different heights of 5 and 7 m. The variables considered were the types and ratios of reinforcement, as well as the free-drop weight and height. The experimental results obtained showed that layered RPC flat solid slabs are superior in resisting and sustaining impact forces and also have fewer scattered parts when compared to NC flat solid slabs. Additionally, the flat solid slab samples reinforced with CFRP bar grids were overall more resistant to impact loads, by an average of 19%, compared to flat solid slabs with steel bars and showed lower deflection, by an average of 10%, compared to the other flat solid slabs. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

17 pages, 8767 KB  
Article
Numerical Simulation and Experimental Study of Carbon Fiber-Reinforced Polymer Single-Bar Extrusion Anchorage Structure
by Wanxu Zhu, Chengyang Xiong, Boxuan Cheng, Quanxi Shen, Hongbin Cheng and Shangqi Guo
Materials 2024, 17(16), 3915; https://doi.org/10.3390/ma17163915 - 7 Aug 2024
Viewed by 889
Abstract
The reliable anchorage of carbon fiber-reinforced polymer (CFRP) tendons is a critical issue influencing the stable bearing capacity of bridge cables. This study introduces a novel CFRP single-strand extrusion anchoring structure, where the strand is compressed at its end. By integrating this with [...] Read more.
The reliable anchorage of carbon fiber-reinforced polymer (CFRP) tendons is a critical issue influencing the stable bearing capacity of bridge cables. This study introduces a novel CFRP single-strand extrusion anchoring structure, where the strand is compressed at its end. By integrating this with internal cone filler wrapping, we create a CFRP multi-strand cable composite anchoring system. This innovative design not only minimizes the overall dimensions of the anchoring system but also significantly improves its anchoring efficiency coefficient. An axisymmetric model was developed using ANSYS finite element software. The radial stress distribution and anchorage efficiency coefficient in the anchorage zone of Φ7 CFRP bar and Φ13.6 extrusion die were analyzed with varying parameters, such as chamfering, outer diameter, and length of the extrusion sleeve, and were validated through static load anchorage tests. The results indicate that the highest anchoring efficiency is achieved when four extrusion sleeves with a chamfer angle of 5°, an outer diameter of Φ14.4, and a length of 15 mm are connected in series, reaching a coefficient of 61.04%. Furthermore, this study proposes an anchorage structure where multiple extrusion sleeves are connected in series and sequentially compressed to overcome the limitations of increasing anchorage length for enhancing the anchorage coefficient. The test results demonstrate that with equal total anchorage length, connecting four 15 mm extrusion sleeves in series enhances the anchorage efficiency coefficient by 24.98% compared to a single 60 mm extrusion sleeve structure. Full article
Show Figures

Figure 1

14 pages, 4710 KB  
Article
Behavior of a Precast Bridge Pier with Basalt Fiber-Reinforced Polymer (BFRP)-Strengthened Segments under Seismic Loading
by Chao Li, Yaowei Peng, Pengyu Yang, Hao Zhou and Ningbo Wang
Polymers 2024, 16(14), 2018; https://doi.org/10.3390/polym16142018 - 15 Jul 2024
Cited by 1 | Viewed by 1390
Abstract
The precast segmental column (PSC) has been proposed for reducing onsite construction time and minimizing impacts on traffic and the environment. It has been proven to have good seismic performance according to previous studies. However, due to the rocking behavior of the column, [...] Read more.
The precast segmental column (PSC) has been proposed for reducing onsite construction time and minimizing impacts on traffic and the environment. It has been proven to have good seismic performance according to previous studies. However, due to the rocking behavior of the column, the toe of the bottom segment could experience excessive compressive damage. In addition, the commonly used steel rebars in the PSC could experience corrosion problems during the service life of the structure. Moreover, ordinary Portland cement concrete (OPC) is normally used in the construction of the PSC, but the manufacturing processes of the OPC could emit a lot of carbon dioxide. This paper investigates the seismic performance of PSCs incorporating Basalt Fiber Reinforced Polymer (BFRP) bars and geopolymer concrete (GPC) segments. To mitigate the concrete crushing damage of the segment, the BFRP sheet was used to wrap the bottom segment of one of the specimens. The results revealed that the BFRP-reinforced geopolymer concrete PSC exhibited good seismic performance with minimal damage and small residual displacement. Strengthening the bottom segment with BFRP wrapping proved to be effective in reducing concrete damage. As a result, the column with BFRP wrap demonstrated the ability to withstand ground motions with higher Peak Ground Acceleration (PGA) compared to the column without strengthening. Full article
Show Figures

Figure 1

Back to TopTop