Emerging Technologies in Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) Systems

A special issue of Processes (ISSN 2227-9717). This special issue belongs to the section "Energy Systems".

Deadline for manuscript submissions: closed (1 April 2022) | Viewed by 23318

Special Issue Editors


E-Mail Website
Guest Editor
Department of Refrigeration, Air Conditioning and Energy Engineering, National Chin-Yi University of Technology Taiwan, Taichung 41170, Taiwan
Interests: two-phase flow; heat exchanger; condensation; frosting
Special Issues, Collections and Topics in MDPI journals

E-Mail Website
Guest Editor
Department of Mechanical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 80778, Taiwan
Interests: thermo-fluid; energy conversion; thermal management; fuel cells
Special Issues, Collections and Topics in MDPI journals

Special Issue Information

Dear Colleagues,

Heating, ventilation, air conditioning and refrigeration (HVAC&R) systems provide physical environment comfort for the occupants at the expense of the consumption of a huge amount of energy. Researchers have made great efforts to develop novel technologies for both alleviating the impact of operating of HVAC systems on the environment and saving energy. In addition, the current global pandemic has made huge impacts on social activities and the economy, leading to new challenges in the development of HVAC systems and technologies with improved energy efficiency for miscellaneous applications.

Therefore, this Special Issue on “Emerging Technologies in Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) Systems” aims to collect and report novel technologies and advances in HVAC&R. Topics include, but are not limited to:

  • Advanced HVAC&R systems and equipment
  • Thermodynamics analysis and energy systems for HVAC&R
  • Novel HVAC&R systems and processes
  • Indoor environmental quality management
  • Experiments and analysis for HVAC&R
  • Simulation approaches and new algorithms for HVAC&R
  • Novel refrigerants and applications
  • Energy efficiency analysis and improvement for HVAC&R
  • Intensive review article on the state-of-the-art of HVAC&R

Prof. Dr. Kai-Shing Yang
Prof. Dr. Jin-Cherng Shyu
Dr. Ming-Tsang Lee
Guest Editors

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All papers will be peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Processes is an international peer-reviewed open access monthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2000 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • heating
  • ventilation
  • air conditioning
  • refrigeration
  • energy efficiency
  • indoor environmental quality
  • thermodynamics

Published Papers (8 papers)

Order results
Result details
Select all
Export citation of selected articles as:

Editorial

Jump to: Research

3 pages, 172 KiB  
Editorial
Special Issue: “Emerging Technologies in Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) Systems”
by Kai-Shing Yang, Jin-Cherng Shyu and Ming-Tsang Lee
Processes 2022, 10(7), 1410; https://doi.org/10.3390/pr10071410 - 20 Jul 2022
Cited by 1 | Viewed by 1196
Abstract
Heating, ventilation, air conditioning and refrigeration (HVAC&R) systems provide physical environment comfort for the occupants at a possible expense of large amount of energy consumption [...] Full article

Research

Jump to: Editorial

21 pages, 10798 KiB  
Article
The Characteristic of High-Speed Centrifugal Refrigeration Compressor with Different Refrigerants via CFD Simulation
by Kuo-Shu Hung, Kung-Yun Ho, Wei-Chung Hsiao and Yean-Der Kuan
Processes 2022, 10(5), 928; https://doi.org/10.3390/pr10050928 - 07 May 2022
Cited by 5 | Viewed by 2506
Abstract
This study used Computational Fluid Dynamics (CFD) to simulate and analyze the working fluid in magnetic centrifugal refrigerant compressors using R-134a to mixed refrigerant: R-513A and HFO (Hydrofluoroolefins) Hydrofluoroolefin refrigerant: R-1234yf, and the impact on integrated part-load performance, Integrated Part Load Value (IPLV) [...] Read more.
This study used Computational Fluid Dynamics (CFD) to simulate and analyze the working fluid in magnetic centrifugal refrigerant compressors using R-134a to mixed refrigerant: R-513A and HFO (Hydrofluoroolefins) Hydrofluoroolefin refrigerant: R-1234yf, and the impact on integrated part-load performance, Integrated Part Load Value (IPLV) and internal flow field. This study used a single-stage 280 USRT maglev centrifugal refrigerant compressor as a simulation model. Three different refrigerants were used: R-134a, R-513A, and R-1234yf, as presented in the National Institute of Standards and Technology (NIST) real gas database. The refrigerant was used to set the IPLV working conditions and change the compressor speed and mass flow rate to simulate the compressor’s characteristic curve after replacing the refrigerant. The compressor working conditions were the fixed refrigeration cycle condensation and evaporation following the same capacity standards. This study used the CFD software by Ansys software company to simulate the flow field. The k-omega turbulence software was used to model the turbulence. The results show that the maglev centrifugal refrigerant compressor efficiency dropped significantly when the refrigerant was directly replaced. Based on R-134a, the full load efficiency of R-1234yf dropped 13.21%, the full load efficiency of R-513A dropped 9.97%, and the partial load efficiency was similar to R-134a. Full article
Show Figures

Figure 1

20 pages, 16483 KiB  
Article
A Study on Flow Field Characteristics and Air Purifier with Barrier Effects
by Yu-Ling Liu, Yean-Der Kuan and Win-Jet Luo
Processes 2022, 10(5), 864; https://doi.org/10.3390/pr10050864 - 27 Apr 2022
Cited by 1 | Viewed by 2418
Abstract
An air curtain machine is used in the entrances and exits of public places where air conditioners are used. The high-speed centrifugal or axial fan blows out the air, creating an airflow barrier to prevent air convection inside and outside, reducing air conditioning [...] Read more.
An air curtain machine is used in the entrances and exits of public places where air conditioners are used. The high-speed centrifugal or axial fan blows out the air, creating an airflow barrier to prevent air convection inside and outside, reducing air conditioning losses, and maintaining the indoor air quality by preventing dust, insects, and harmful gases from entering the room. Observation of the airflow behavior was conducted using CFD simulation, to explore whether it has a blocking effect, and the air curtain principle was applied to the air purification equipment. It is mainly composed of several rows of arrayed hole air outlets to form a multi-composite air wall. The airflow on the two sides, or below, can be blocked by the composite air wall and integrated into the main airflow, so that the air walls will not affect each other, and form a barrier effect to prevent infection. This research includes the measurement of impedance characteristics for three layers of filters made of different materials. These filters are used as the input characteristic parameters in the simulation analysis. Four scenarios are discussed, including the consultation room, hospital ward, quarantine station, and conference room. From the simulation results, it is known that when there are many people, the equipment can be set to high speed to increase the volume of air, forming a wind wall to effectively block airflow from the people in the chairs, reducing the risk of infection. Note that the rotation speed should not be too high. The air outlet equipment is susceptible to turbulent flow, which will make the airflow deviate from the expected direction and increase the possibility of mutual infection between adjacent people. Partitions can be used to block airflow to reduce the risk of infection. Full article
Show Figures

Figure 1

16 pages, 3764 KiB  
Article
Study of Gas-to-Liquid Heat Pipe Heat Exchanger
by Pratik Prakash Gupta, Sundararaj Senthilkumar and Shung-Wen Kang
Processes 2022, 10(5), 808; https://doi.org/10.3390/pr10050808 - 20 Apr 2022
Cited by 1 | Viewed by 2614
Abstract
This study is focused on the study and development of a gas-to-liquid heat pipe heat exchanger (HPHE) based on numerical and experimental analysis. Stainless steel heat pipes were installed inside the heat exchanger in the form of three equilateral triangles, staggered into a [...] Read more.
This study is focused on the study and development of a gas-to-liquid heat pipe heat exchanger (HPHE) based on numerical and experimental analysis. Stainless steel heat pipes were installed inside the heat exchanger in the form of three equilateral triangles, staggered into a hexagonal configuration to simulate the waste heat recovery from hot exhaust gas to a water flow. The first main aim of this study was focused on 3D design and numerical analysis, which were used to create and calculate the effect of similar input conditions on the overall system. The system was tested for the overall heat transfer by measuring the temperature change in both fluids. The heat transfer and overall average temperature were used to calculate the effectiveness of the system. In the second part of this study, a test of the waste heat recovery was undertaken with this setup, using water as the cooling fluid. The study was conducted with different input velocities and temperatures of waste hot air, controlled simultaneously by the input fan and air heater, whereas the cooling water was kept at a steady state of 30 °C and 0.0156 kg/s at the input. The hot air velocity was controlled by fans with different inlet air velocities of 0.3 m/s, 0.5 m/s, and 0.7 m/s. Moreover, the temperature of the air was changed from 150 °C to 250 °C with a step of 25 °C. The increase in temperature and the velocity of air was directly proportional to the amount of heat transferred from the air to the cooling water, and the effectiveness was also found to be inversely proportional to both of the varying input parameters. The numerical study showed a maximum increase of 12% in the heat transfer. The output temperatures of hot and cold fluids showed maximum increases of 7 K and 3 K, respectively. The numerical system with such input parameters can be evaluated further to predict the behavior of changes in the design and parameters. Full article
Show Figures

Figure 1

25 pages, 12295 KiB  
Article
A Data-Driven Identification Procedure for HVAC Processes with Laboratory and Real-World Validation
by Peter Minarčík, Hynek Procházka and Martin Gulan
Processes 2022, 10(1), 83; https://doi.org/10.3390/pr10010083 - 31 Dec 2021
Cited by 1 | Viewed by 2707
Abstract
Linear system identification is a well-known methodology for building mathematical models of dynamic systems from observed input–output data. It also represents an essential tool for model-based control design, adaptive control and other advanced control techniques. Use of linear identification is, however, often limited [...] Read more.
Linear system identification is a well-known methodology for building mathematical models of dynamic systems from observed input–output data. It also represents an essential tool for model-based control design, adaptive control and other advanced control techniques. Use of linear identification is, however, often limited to academic environment and to research facilities equipped with scientific computing platforms and highly qualified staff. Common industrial or building control system technology rarely uses these advanced design techniques. The main obstacle is typically lack of experience with their practical implementation. In this article, a procedure is proposed, implemented, and tested, that brings the benefits of linear identification into broader control system practice. The open-source DCU control system platform with its advanced control framework is used for implementation of the proposed linear identification procedure. The procedure is experimentally tested in the laboratory setting using a unique model of HVAC system as well as in real-world environment in an experimental two storey family house. Testing this novel feature of the control system has proved satisfactory results, while some of them are presented in graphical and numerical form. Full article
Show Figures

Figure 1

12 pages, 42591 KiB  
Article
Heat Transfer Performance of R-1234ze(E) with the Effect of High-Viscosity POE Oil on Enhanced GEWA-B5H Tube
by Abhishek Kumar, Miao-Ru Chen, Jung-Hsien Wu, Kuo-Shu Hung, Li-Kang Su and Chi-Chuan Wang
Processes 2021, 9(12), 2285; https://doi.org/10.3390/pr9122285 - 20 Dec 2021
Cited by 7 | Viewed by 2521
Abstract
In this study, the heat transfer performance of high-viscosity polyol ester (POE) oil POEA-220 (220 cSt) with low-GWP (global warming potential) refrigerant R-1234ze(E) on enhanced GEWA-B5H tube was investigated at saturation temperatures of 10 °C, 0 °C, and −6 °C. The mass fraction [...] Read more.
In this study, the heat transfer performance of high-viscosity polyol ester (POE) oil POEA-220 (220 cSt) with low-GWP (global warming potential) refrigerant R-1234ze(E) on enhanced GEWA-B5H tube was investigated at saturation temperatures of 10 °C, 0 °C, and −6 °C. The mass fraction of oil varied from 0.25% to 10%, and all the nucleate pool boiling data were measured at heat fluxes ranging from 10 kW/m2 to 90 kW/m2. The experimental results showed that the heat transfer performance of the R-1234ze(E)/POEA-220 mixtures were superior to the R-1234ze(E)/POEA-68 mixtures. At saturation temperatures of 0 °C and −6 °C, even a 10% mass fraction of the POEA-220 oil showed an enhancement in the HTC (heat transfer coefficient) compared to the pure refrigerant in the moderate heat flux range. On the other hand, for the R-1234ze(E)/POEA-68 mixtures, a 5% mass fraction of oil showed no enhancement in the HTC compared to pure refrigerant at the same saturation temperature. Moreover, at low saturation temperatures (0 °C and −6 °C), the enhancement in the HTC decreased with increasing mass fraction of low-viscosity oil POEA-68, whereas high-viscosity oil POEA-220 showed the highest enhancement in the HTC for a 5% mass fraction of oil at −6 °C saturation temperature compared to the pure refrigerant. The results indicate that for nucleate boiling, the effect of oil viscosity on heat transfer performance is negligible if it contains comparatively high thermal conductivity and low surface tension. In addition, the effect of surface aging on heat transfer performance for the GEAW-B5H tube with pure refrigerant was also reported. Full article
Show Figures

Figure 1

26 pages, 56241 KiB  
Article
Evaluating the Performance of Water Chillers Equipped with Constant- or Variable-Frequency Centrifugal Compressors
by Chih-Neng Hsu and Shih-Hao Wang
Processes 2021, 9(6), 1039; https://doi.org/10.3390/pr9061039 - 14 Jun 2021
Cited by 6 | Viewed by 5442
Abstract
The cooling coefficient of performance (COPR) and energy efficiency ratio (EER) of refrigerant R-134a compressors (single- and double-compressors) with different refrigerant tonnage (200, 250, 300, 380, 500, and 700 RT) for centrifugal and Maglev centrifugal compressors change with different operating performance [...] Read more.
The cooling coefficient of performance (COPR) and energy efficiency ratio (EER) of refrigerant R-134a compressors (single- and double-compressors) with different refrigerant tonnage (200, 250, 300, 380, 500, and 700 RT) for centrifugal and Maglev centrifugal compressors change with different operating performance load percentages (10–100%), and constant-frequency and variable-frequency operation, resulting in performance differences. In particular, a water chiller can have a fixed cooling water inlet temperature of 32 °C and a variable cooling water inlet temperature between 18.33 °C and 32 °C. According to the actual test results, the commercial performance code program and parameter table of the water chiller were established. Based on the performance matching of different load chillers, the on-site load capacity was analyzed and the effective water chiller performance and model matching were determined as the best choice for the tonR number of the deicing machine and unit matching, providing a reference for a future large water chiller that cannot be used on site for a single unit tonR. To achieve energy-saving benefits, different types of compressors, different refrigeration tonR operation, constant-frequency unit and variable-frequency unit alternate operation, and different operating performance load percentage operation can be allocated. Finally, the results show that, when the cooling water inlet temperature is fixed, the Maglev variable-frequency centrifugal compressor water chiller is better than the constant-frequency centrifugal water chiller, and also better than the variable-frequency centrifugal water chiller. The larger the freezing tonR of the variable-frequency centrifugal water chiller, the smaller the difference between COPR and EER. When the cooling water inlet temperature changes, the Maglev variable-frequency centrifugal water chiller is better than the constant-frequency centrifugal water chiller, and it is also better than the variable-frequency centrifugal water chiller. The larger the freezing tonR of the variable-frequency centrifugal water chiller, the smaller the difference between COPR and EER. Moreover, the operating performance of the constant-frequency centrifugal water chiller is between 60% and 90%, which can maintain relatively high COPR and EER values. The operating performance of the variable-frequency centrifugal water chiller is between 40% and 70%, which can maintain relatively high COPR and EER values. Compared with the constant-frequency and variable-frequency, the Maglev variable-frequency centrifugal water chiller can maintain higher COPR and EER values when the operating performance is between 10% and 100%. When the operating performance is between 10% and 70%, it can maintain very high COPR and EER values. When the water chiller is selected in the field, the energy-saving of COPR and EER will be given priority. Therefore, the load capacity can be used to effectively manage the water chiller performance and model selection, so that the operation performance can reach the best percentage and energy saving can be achieved. Full article
Show Figures

Figure 1

17 pages, 2142 KiB  
Article
A Semi-Empirical Model for Predicting Frost Properties
by Shao-Ming Li, Kai-Shing Yang and Chi-Chuan Wang
Processes 2021, 9(3), 412; https://doi.org/10.3390/pr9030412 - 25 Feb 2021
Cited by 7 | Viewed by 1787
Abstract
In this study, a quantitative method for classifying the frost geometry is first proposed to substantiate a numerical model in predicting frost properties like density, thickness, and thermal conductivity. This method can recognize the crystal shape via linear programming of the existing map [...] Read more.
In this study, a quantitative method for classifying the frost geometry is first proposed to substantiate a numerical model in predicting frost properties like density, thickness, and thermal conductivity. This method can recognize the crystal shape via linear programming of the existing map for frost morphology. By using this method, the frost conditions can be taken into account in a model to obtain the corresponding frost properties like thermal conductivity, frost thickness, and density for specific frost crystal. It is found that the developed model can predict the frost properties more accurately than the existing correlations. Specifically, the proposed model can identify the corresponding frost shape by a dimensionless temperature and the surface temperature. Moreover, by adopting the frost identification into the numerical model, the frost thickness can also be predicted satisfactorily. The proposed calculation method not only shows better predictive ability with thermal conductivities, but also gives good predictions for density and is especially accurate when the frost density is lower than 125 kg/m3. Yet, the predictive ability for frost density is improved by 24% when compared to the most accurate correlation available. Full article