Next Article in Journal
Derivation and Application of Analytical Coupling Loss Coefficient by Transfer Function in Soil–Building Vibration
Previous Article in Journal
Enhancing Risk Management in Road Infrastructure Facing Flash Floods through Epistemological Approaches
Previous Article in Special Issue
Design and Performance Study of a Six-Leg Lattice Tower for Wind Turbines
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Seismic Performance of Cross-Shaped Partially Encased Steel–Concrete Composite Columns: Experimental and Numerical Investigations

1
Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics, China Earthquake Administration, Harbin 150076, China
2
Key Laboratory of Earthquake Disaster Mitigation, Ministry of Emergency Management, Harbin 150076, China
3
School of Civil Engineering, Hefei University of Technology, Anhui 230009, China
*
Author to whom correspondence should be addressed.
Buildings 2024, 14(7), 1932; https://doi.org/10.3390/buildings14071932
Submission received: 7 May 2024 / Revised: 13 June 2024 / Accepted: 21 June 2024 / Published: 25 June 2024
(This article belongs to the Special Issue Novel Steel and Steel-Concrete Composite Structures)

Abstract

Special-shaped partially encased steel–concrete composite (PEC) columns could not only improve the aesthetic effect and room space use efficiency, but also exhibit good mechanical performance under static load when used in multi-story residential and office buildings. However, research on the seismic performance of special-shaped PEC columns is insufficient and urgently needed. To investigate the seismic performance of cross-shaped partially encased steel–concrete composite (CPEC) columns, three CPEC columns were designed and tested under combined constant axial load and lateral cyclic load. The test results show that the CPEC columns had good load capacity and ductility, and that the columns failed because of concrete crushing and steel flange buckling after the yielding of the steel flange. The plump hysteresis loops indicated that the CPEC column also had good energy dissipation capacity. Due to the constraint of hydraulic jacks, increasing the load ratio would decrease the effective length, thereby increasing the load capacity of the CPEC column and decreasing the ductility. A finite element model was also established to simulate the response of the CPEC columns, and the simulated results agree well with the experimental results. Thereafter, an extensive parametric analysis was performed to study the influences of different parameters on the seismic performance of CPEC columns. For the CPEC column with an ideal hinged boundary condition at the top, its lateral load capacity gradually decreases with the growth of the load ratio and link spacing and increases with the rise of the steel yield strength, concrete compressive strength, flange and web thickness, and sectional aspect ratio. This research could provide a basis for future theoretical analyses and engineering application.
Keywords: partially encased steel–concrete composite columns; cross-shaped; seismic performance; experimental investigation; finite element analysis partially encased steel–concrete composite columns; cross-shaped; seismic performance; experimental investigation; finite element analysis

Share and Cite

MDPI and ACS Style

Xu, Q.; Liu, Y.; Wang, J. Seismic Performance of Cross-Shaped Partially Encased Steel–Concrete Composite Columns: Experimental and Numerical Investigations. Buildings 2024, 14, 1932. https://doi.org/10.3390/buildings14071932

AMA Style

Xu Q, Liu Y, Wang J. Seismic Performance of Cross-Shaped Partially Encased Steel–Concrete Composite Columns: Experimental and Numerical Investigations. Buildings. 2024; 14(7):1932. https://doi.org/10.3390/buildings14071932

Chicago/Turabian Style

Xu, Qiuyu, Yong Liu, and Jingfeng Wang. 2024. "Seismic Performance of Cross-Shaped Partially Encased Steel–Concrete Composite Columns: Experimental and Numerical Investigations" Buildings 14, no. 7: 1932. https://doi.org/10.3390/buildings14071932

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop