Article

Effect of a Geothermal Heat Pump in Cooling Mode on the Housing Environment and Swine Productivity Traits

1
Animal Nutrition and Feed Science Laboratory, Department of Animal Science and Technology, Sunchon National University, Suncheon 57922, Korea
2
Department of Multimedia Engineering, Sunchon National University, Suncheon 57922, Korea
3
Interdisciplinary Program in IT-Bio Convergence System (BK21 plus), Sunchon National University, 255, Jungangno, Suncheon 57922, Korea
4
Department of Mechanical Convergence Engineering, Hanyang University, Seoul 04763, Korea
5
WP Co., Ltd., Suncheon 58023, Korea
*
Author to whom correspondence should be addressed.
Both authors have contributed equally to the manuscript as co-first authors.
Appl. Sci. 2021, 11(22), 10778; https://doi.org/10.3390/app112210778
Submission received: 15 October 2021 / Revised: 11 November 2021 / Accepted: 11 November 2021 / Published: 15 November 2021

Abstract

:
This study compared the effects of the cooling mode of a geothermal heat pump (GHP) system with those of a traditional cooling system (ventilation fans) inside a pig house on the internal house temperature, harmful gas emissions, and the growth performance of the pigs. During the 19-week experimental period, the temperature inside the house connected to the GHP cooling system was significantly lower (p < 0.05) than that of a house with a conventional cooling system. Similarly, the temperature–humidity index (THI) was significantly reduced (p < 0.05) in the GHP cooling system-connected pig house. Furthermore, the concentrations of ammonia (NH3) and hydrogen sulfide (H2S) were also decreased significantly in the GHP-installed pig house (p < 0.05). However, no differences were observed in the concentrations of particulate matter (PM2.5) and formaldehyde (p > 0.05). The pigs reared in the GHP-equipped pig house gained significantly more weight (p < 0.05) by the end of the experiment. The GHP cooling system can therefore be implemented as a renewable, environmentally friendly energy source in pig farms for sustainable swine production without adversely affecting the productivity parameters.

1. Introduction

Energy, as a topic, is gaining attention in the livestock sector because the consumption of energy in the rearing of animals will play a vital role in the future. According to UN research [1], the world population will reach 9.15 billion by 2050, thus increasing the demand for food. This will lead to an increase in the consumption of livestock products by 40–80%, compared with the consumption in 2010 [2]. As a result, the energy required to sustain the demand for animal protein will increase in the near future. Against the background of decreasing fossil energy resources due to their high demand and price, the use of renewable energy resources is an important alternative to energy from fossil fuels in the agriculture sector [3].
The use of energy in livestock production has gained attention recently because of its harmful impact on the environment [4]. In pig housing, it is necessary to provide an adequate housing environment for optimum production, and to satisfy the legislation regarding animal welfare demands [5]. Temperature, moisture, and indoor air quality are important parameters for indoor housing environments. Temperature control is crucial for pigs, and a slight variation in the inside temperature has a negative impact on their health, growth, and performance [6]. A pig house contains a large variety of air pollutants—such as NH3, CO2, fine particles, microbes, and endotoxins—which cause environmental pollution and global warming [7]. Therefore, it is time to utilize renewable energy resources which reduce environmental pollution for the maintenance of indoor housing environments.
GHP systems have been successfully utilized as alternative renewable energy sources [8] in many countries [9]. They are environmentally friendly, and can reduce electricity consumption [10]. In a GHP system, the internal air quality improves owing to the supply of fresh air, and there is also no direct combustion that produces pollutants [11]. Similarly, GHP can reduce electricity consumption by consuming one unit of electricity to provide three units of geothermal energy [12]. The use of renewable energy sources is relatively low in Korea compared to other developed countries; however, GHP systems have been gaining popularity for cooling and heating. The Korean government is taking steps to increase the use of new and renewable energy from 2.1% in 2004 to 11% in 2030. In Korea, the energy acquired will be 200 times the main energy consumption if 2% of the geothermal energy resources to a depth of 5 km are used [13]. These energy resources can be used at a depth of 100–500 m to operate a GHP for livestock [14]. Several authors [4,7,14,15] have reported the beneficial effects of a heating system using a GHP on environmental pollution, energy consumption, and production performance in livestock farms. However, to the best of our knowledge, the cooling effects of GHP systems in pig farms during summer have not yet been reported. Therefore, the aim of this experiment was to assess the effects of the GHP cooling system on pig growth performance, housing conditions, and the emission of noxious gases.

2. Materials and Methods

2.1. Ethics

This study was performed at the experimental farm of Sunchon National University, 57922 Suncheon, South Korea. All of the experimental protocols and the rearing of the animals were in line with the guidelines of the Animal Care and Use Committee (SCNU IACUC 2020-09).

2.2. Experimental Design

The performance of the GHP cooling mode was evaluated in a pig house during the summer season. The pigs were reared for 19 weeks, from 29 May 2020 to 9 October 2020. The growth period was further divided into four phases, as follows: 5 weeks for weaning, 4 weeks for growing, 5 weeks for early finishing, and 5 weeks for the late finishing phase. The pig house was divided into two separate rooms (3 m wide × 8 m long), which were further divided into 10 individual pens for replication (Figure 1).
Both rooms were environmentally controlled and were orientated similarly; the first was installed with a conventional cooling system (ventilation fans) and served as a control, while the other room was connected to the ground water source geothermal heat pump in cooling mode. The control pig house was equipped with one big fan and two small fans operating at 1150 and 1700 rpm, respectively. The ventilatory volume of the large fan ranged from 677 cubic feet per minute (CFM) to 1574 CFM, while that of the small fan ranged from 451 to 1097 CFM. The ventilation rate was regulated at 75 CFM/unit for the early and late finishing pigs, 35 CFM/unit for growing pigs, and 25 CFM/unit for weaning piglets. The pigs were reared on slatted floors, and were offered water and commercially available phase-appropriate feed ad libitum. The feed formulation and chemical composition of the diets are presented in Table 1.

2.3. Description of the GHP System

The heat pump unit (DHGW 5N-C4-02, Daesung Heat Enersys, Seoul, Korea) was installed in the pig house (Figure 2 and Figure 3). The system consisted of a 150 m-deep double U-tube borehole exchanger (BHE), a fan coil unit (FCU), water-circulating pumps, and a water tank. The cooling ability of the heat pump was 20.59 kW, with a 4.93 kW rating of electric power consumption. The freezing capacity of the system was 2.1 RT, and R-410A was used as a refrigerant. The water storage capacity of the tank was approximately 260 L. The FCU can generate different wind speeds, with a temperature range of 5–45 °C. Three circulating pumps (Wilo Pump, Ansan, Korea) were attached to the system: (1) a PH-200M with a flow rate of 136 L/min, which was used for the transfer of ground water to the heat pump; (2) a PH-080M with a flow rate of 75 L/min, which was used for the transfer of water from the heat pump to the tank; and (3) a PB-600MA with a flow rate of 80 L/min, which was used for the transfer of water from the tank to the pig house.
The heat pump unit had a rolling compressor piston, a thermostatic expansion valve, and a copper tube with tube heat exchangers. The exchangers increased (in heating mode) and decreased (in cooling mode) the temperature of air, and distributed it through the pig house via plastic ducts. The air inside the pig house was replaced with incoming air. The volumetric flow of air through the heat pump was 700 m3/min.

2.4. Internal House Temperature and Temperature–Humidity Index (THI)

The temperature and humidity were measured using T-type thermocouples and thermistors with sensors with a range of −20 to 80 °C ± 0.2 °C for temperature and 0–100% for humidity.
The temperature–humidity index (THI) was calculated from the relative humidity and temperature as an indicator of the heat stress using the following equation [16]:
THI = 0.8T + (RH/100) × (T − 14.3) + 46.4,
where T = temperature (°C), and RH = relative humidity (%).

2.5. Coefficient of Performance (COP) and the Heat Pump Outflow and Inflow Temperatures

The temperature of the inflow and outflow water (hot and cold) of the GHP was measured using a GPT-1000 pipe temperature sensor (Ginice, Korea), which is equipped with a high-grade thermistor sensing element with a temperature ranging from −50 °C to 150 °C.
The COP of the system in cooling mode was calculated using equation [9]:
COP = Cooling   capacity Power   input
COP = QH W W
where QH = heat transferred to the ground (kW), and W = total electricity consumption (kWh)

2.6. Concentration of Ammonia (NH3) and Hydrogen Sulfide (H2S)

The concentration of NH3 was measured by installing a sensor (City Technology NH3 3E 100 SE, Bonn, Germany) at a height of 1.9 m in the middle of the swine house, with a range of 0–50 ppm. Similarly, the concentration of H2S was measured by installing a sensor (Alphasense Ltd. H2S-B4 sensor, Great Notley, UK). Every week, the concentrations of both gases were also measured manually using a gas sampling pump (Gastec Corp, GV-100, Ayase-Shi, Japan) and gas detection tubes (3 L for NH3 and 4LT for H2S) to validate the values from the sensors.

2.7. Formaldehyde (FA) and Particulate Matter (PM2.5)

The FA and PM2.5 levels were measured daily by placing a sensor (Smart Air quality meter AR830A, Dongguan, China) in the middle of the pig house. The range of the sensor was 0–150 µg/m3 for PM2.5 and 0–50 ppm for formaldehyde.

2.8. Growth Performance Measurement

The body weight gain (BWG), feed intake (FI), and feed conversion ratio (FCR) were measured. The animals were weighed at the start and end of each phase individually (weaning, growing, finishing, and late-finishing), and the BWG was calculated weekly. The FI was determined weekly by subtracting the remaining feed from the total amount of feed offered. The FCR was calculated by dividing the FI by the BWG.

2.9. Statistics

Statistical Analysis System software (SAS 2011, Cary, NS, USA) was used to analyze the data, and the results are shown as the mean values and the standard error of the mean (SEM). The analysis of variance (ANOVA) was used to compare the parameters in the groups, and Duncan’s multiple range test was used to compare the means. Tendencies were identified when 0.05 < p < 0.10, and differences were considered significant at p < 0.05.

3. Results

3.1. Pig House Temperature and THI

The inside temperatures of the control and GHP cooling system houses are presented in Table 2. The setting temperature during the weaning phase was maintained at 26 °C, and was then gradually reduced at a rate of 1 °C every week until it reached 20 °C. The temperature during the weaning and growing phases did not decrease (p > 0.05). However, the inside temperature was reduced (p < 0.05) in the early and late finishing periods. The temperature during early finishing and late finishing was decreased by 17% and 9%, respectively, in the GHP cooling system relative to the temperature of the control house. Similarly, the THI of the GHP-installed pig house was decreased (p < 0.05) over the 19-week trial (Figure 4).

3.2. Heat Pump Outlet and Inlet Temperature and COP

The outflow water temperature from the heat pump decreased by 7.44, 14.74, and 11.83 °C during the weaning, growing, and finishing phases, respectively, compared to the inflow water temperature. The maximum and minimum COP calculated were 4.50 during the early finishing and 4.10 during the weaning phase, respectively (Table 3).

3.3. Particulate Matter (PM2.5), Formaldehyde, NH3 and H2S Concentartions

The concentration of FA in the pig house was not affected (p > 0.05) by the cooling system during the experiment (Table 4). Similarly, the concentration of PM2.5 remained unaffected (p > 0.05), except during the early finishing phase. On the other hand, the concentration of noxious gases (NH3 and H2S) decreased (p < 0.05) in the GHP-connected pig house compared to the control (Figure 5).

3.4. Growth Performance

Table 5 shows the effect of the GHP cooling system on the growth performance of the pigs. From 0 to 19 weeks, the weight of pigs significantly increased in the GHP-connected house relative to that in the control (p < 0.05).

4. Discussion

The ambient temperature inside a pig house is a crucial parameter for pig farming, and variation in this parameter may have a negative impact on pig productivity [17]. In Korea, heating pig houses is essential during the winter season, whereas they need to be cooled in hot weather. Research has shown that heat shock or cold stress substantially affect the growth and reproduction performance, welfare, and health of animals [18,19]. In general, cold stress is common in weaning pigs, while the effects of heat stress are more of a concern in finishing pigs. Therefore, a major proportion of the total cost involved in pig farming is spent on maintaining the optimum temperature for pigs [20]. Similarly to our study, various experiments conducted in other countries have also reported the cooling and heating efficiencies of GHPs in broiler houses and swine farms [4,15,21]. In the current study, the decrease in temperature in the GHP-installed house might be because of the efficient degree change per unit of energy consumption of the GHP system [9]. Additionally, a direct heat exchange system in a single-loop configuration increases the efficiency of the GHP system [22], which can efficiently increase or decrease the temperature of the pig house depending on the season. THI is considered as a basis for the safety index to explain the categories of heat stress in animals. Myer and Bucklin [19] reported that humidity is not harmful for swine unless a high temperature is combined with a high humidity. According to the National Atmospheric and Oceanic Administration [23], THI ≥ 84 is classified as an emergency, THI ≤ 74 is safe, and 74 < THI < 79 is considered as an alert for animal welfare. In the present study, the THI of the GHP-connected pig house fell within the safety zone for all of the phases of growth.
The COP is measured by dividing the heat output (kWh) by the electrical input (kWh), and it indicates the performance of the cooling system. The calculated COP-day average in this study was 4.36, with the COP ranging from 4.10 to 4.50. The calculated COP of the GHP cooling system was the same as the COP of 4.38 observed by Chokchai et al. [9] for a GHP cooling system. On average, the COP of a ground-source GHP lies within the range of 4.19 to 4.57 in cold weather and 3.9 to 4.53 in the summer season [24]. The results of the present study also fall within the optimum parameters, indicating the performance index and efficiency of the GHP cooling system. Aikins et al. [25] also reported that water–water-type GHP systems are popular in Korea because of their ability to heat and cool, and their better COP values. The decreased water outflow temperature from the heat pump demonstrates the efficiency of the GHP cooling system [15] in maintaining the optimum temperature of the swine house.
In the present study, the reduction in the concentration of noxious gases is in agreement with the studies of Choi et al. [21] and Mun et al. [15], in which the cooling and heating effects of the GHP decreased the concentration of particulate matter and ammonia inside the swine house. This is because GHPs can provide fresh air continuously, which dilutes the harmful gases and improves the air quality [7]. NH3 and H2S gases are harmful to animal health and also have harmful effects on the health of farmers and the environment [26]. Generally, the concentration of H2S is less than 2 ppm, and the NH3 concentration is in the range of 0 to 40 ppm on swine farms [27]. Similarly, PM2.5 and the release of formaldehyde have harmful effects on the respiratory systems of humans and animals, and have a detrimental impact on the environment [28]. Particulate matter includes airborne particles with an aerodynamic diameter of 2.5 µm or less. PM2.5 has become a threat to public health in South Korea, and can damage the lungs and penetrate the blood–brain and placental barriers. Formaldehyde is classified as a carcinogenic compound, and can cause irritation to the skin and eyes. No significant differences were observed in the concentration of PM2.5 and formaldehyde (except in the early finishing period in the case of PM2.5), and the values of PM2.5 and formaldehyde were in line with ambient air quality standards (AQS) in South Korea. The AQS safety range of PM2.5 is 50 µg/m3, and formaldehyde has no harmful effects at concentrations of 0.10–0.11 ppm [29,30]. Geothermal energy is popular worldwide as an environmentally friendly and renewable energy source that has a significant impact on the reduction of global climate change, protects public and animal health, and enhances energy security [31]. While conducting several experiments [4,14,26] using GHP cooling and heating systems in poultry and swine houses, different scientists have reported the beneficial effects of the economically effective GHP cooling and heating system on the environment.
The important economic drivers for pig farmers are market weight and FCR [32], which cannot be ignored while introducing any of the latest innovations and technologies. In this study, the final BWG at the end of the experiment was significantly increased in the GHP-installed pig house. This might be due to the weight gain in the finishing period because the GHP cooling system maintained the internal temperature of the pig house within the thermoneutral zone. It has also been reported that heat stress negatively affects growth performance by decreasing FI, which eventually decreases the weight of pigs [33]. Therefore, a GHP cooling system can be installed in pig houses to reduce heat stress whilst having a positive impact on the growth performance parameters.

5. Conclusions

The implementation of a GHP cooling system in pig farms can improve the housing environment and growth performance parameters. Furthermore, GHPs are an environmentally friendly, renewable energy resource that can reduce the emission of noxious gases. Because of the high installation cost at animal farms, government assistance through subsidies is necessary for farmers to protect the environment and save energy. Further studies are recommended at commercial swine farms to evaluate the heating and cooling effects of the GHP system.

Author Contributions

Conceptualization, C.-D.K., H.-S.M., S.-R.L., K.-W.P., S.-B.R. and C.-J.Y.; methodology, M.A.D., K.-W.P., D.R., H.-S.M., S.-R.L. and S.-B.R.; validation, M.A.D., H.-S.M. and C.-J.Y.; software, M.A.D., C.-D.K. and H.-S.M.; formal analysis, H.-S.M., D.R., M.A.D., S.-R.L. and K.-W.P.; investigation, M.A.D., H.-S.M., D.R., S.-R.L., K.-W.P., S.-B.R. and I.-B.C.; data curation, H.-S.M., M.A.D., D.R.; resources, S.-R.L., K.-W.P., S.-B.R. and C.-J.Y.; writing—original draft preparation, H.-S.M., D.R. and M.A.D.; writing—editing and review, M.A.D., H.-S.M., I.-B.C., C.-D.K. and C.-J.Y.; visualization, M.A.D., H.-S.M., D.R.; supervision, C.-J.Y., H.-S.M., S.-B.R., S.-R.L., I.-B.C. and K.-W.P.; funding acquisition, C.-J.Y., H.-S.M. and K.-W.P.; project administration, S.-B.R.,S.-R.L., K.-W.P., C.-D.K. and C.-J.Y. All authors have read and agreed to the published version of the manuscript.

Funding

This research was supported by the Ministry of Trade, Industry and Energy, South Korea.

Institutional Review Board Statement

All of the experimental protocols and the rearing of the animals were in line with the guidelines of the Animal Care and Use Committee of Sunchon National University (SCNU IACUC 2020-09).

Informed Consent Statement

Not Applicable.

Data Availability Statement

Not Applicable.

Acknowledgments

We would like to acknowledge the Industrial Technology Innovation Business (20194210100020, Development and Demonstration of Renewable Energy Mixed-Use System for the Livestock Industry) for their support.

Conflicts of Interest

The authors have no conflict of interest to declare.

References

  1. United Nations. World Population Prospects: The 2008 Revision; Highlights United Nations, Department of Economic and Social Affairs, Population Division: New York, NY, USA, 2009. [Google Scholar]
  2. FAO World Livestock. Livestock in Food Security; FAO: Rome, Italy, 2011. [Google Scholar]
  3. Krommweh, M.S.; Rösmann, P.; Büscher, W. Investigation of Heating and Cooling Potential of a Modular Housing System for Fattening Pigs with Integrated Geothermal Heat Exchanger. Biosyst. Eng. 2014, 121, 118–129. [Google Scholar] [CrossRef]
  4. Islam, M.M.; Mun, H.-S.; Bostami, A.B.M.R.; Ahmed, S.T.; Park, K.-J.; Yang, C.-J. Evaluation of a Ground Source Geothermal Heat Pump to Save Energy and Reduce CO2 and Noxious Gas Emissions in a Pig House. Energy Build. 2016, 111, 446–454. [Google Scholar] [CrossRef]
  5. Licharz, H.; Rösmann, P.; Krommweh, M.S.; Mostafa, E.; Büscher, W. Energy Efficiency of a Heat Pump System: Case Study in Two Pig Houses. Energies 2020, 13, 662. [Google Scholar] [CrossRef] [Green Version]
  6. Costantino, A.; Fabrizio, E.; Ghiggini, A.; Bariani, M. Climate Control in Broiler Houses: A Thermal Model for the Calculation of the Energy Use and Indoor Environmental Conditions. Energy Build. 2018, 169, 110–126. [Google Scholar] [CrossRef]
  7. Choi, H.C.; Salim, H.M.; Akter, N.; Na, J.C.; Kang, H.K.; Kim, M.J.; Kim, D.W.; Bang, H.T.; Chae, H.S.; Suh, O.S. Effect of Heating System Using a Geothermal Heat Pump on the Production Performance and Housing Environment of Broiler Chickens. Poult. Sci. 2012, 91, 275–281. [Google Scholar] [CrossRef]
  8. Lund, R.; Ilic, D.D.; Trygg, L. Socioeconomic Potential for Introducing Large-Scale Heat Pumps in District Heating in Denmark. J. Clean. Prod. 2016, 139, 219–229. [Google Scholar] [CrossRef] [Green Version]
  9. Chokchai, S.; Chotpantarat, S.; Takashima, I.; Uchida, Y.; Widiatmojo, A.; Yasukawa, K.; Charusiri, P. A Pilot Study on Geothermal Heat Pump (GHP) Use for Cooling Operations, and on GHP Site Selection in Tropical Regions Based on a Case Study in Thailand. Energies 2018, 11, 2356. [Google Scholar] [CrossRef] [Green Version]
  10. Majuri, P. Ground Source Heat Pumps and Environmental Policy—The Finnish Practitioner’s Point of View. J. Clean. Prod. 2016, 139, 740–749. [Google Scholar] [CrossRef]
  11. Benli, H.; Durmuş, A. Evaluation of Ground-Source Heat Pump Combined Latent Heat Storage System Performance in Greenhouse Heating. Energy Build. 2009, 41, 220–228. [Google Scholar] [CrossRef]
  12. Charoenvisal, K. Energy Performance and Economic Evaluations of the Geothermal Heat Pump System Used in the KnowledgeWorks I and II Buildings, Blacksburg, Virginia. Master’s Thesis, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA, 2008. [Google Scholar]
  13. Lee, J.-Y. Current Status of Ground Source Heat Pumps in Korea. Renew. Sustain. Energy Rev. 2009, 13, 1560–1568. [Google Scholar] [CrossRef]
  14. Choi, H.C.; Park, J.H.; Song, J.I.; Na, J.C.; Kim, M.J.; Bang, H.T.; Kang, H.J.; Park, S.B.; Chae, H.S.; Suh, O.S.; et al. Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House. J. Anim. Environ. Sci. 2010, 16, 205–215. [Google Scholar]
  15. Mun, H.S.; Dilawar, M.A.; Jeong, M.G.; Rathnayake, D.; Won, J.S.; Park, K.W.; Lee, S.R.; Ryu, S.B.; Yang, C.J. Effect of a Heating System Using a Ground Source Geothermal Heat Pump on Production Performance, Energy-Saving and Housing Environment of Pigs. Animals 2020, 10, 2075. [Google Scholar] [CrossRef]
  16. Adebiyi, O.A.; Muibi, M.A.; Alaba, O. Performance and Behavioural Characteristics of Pigs as Affected by Types and Duration of Evaporative Cooling. Niger. J. Anim. Sci. 2017, 2, 103–113. [Google Scholar]
  17. Hessel, E.F.; Zurhake, C. Heating and cooling performance of an under floor earth tube air tempering system in a mechanical ventilated farrowing house. In Proceedings of the XVII World Congress of the International Commission of Agricultural and Bio Systems Engineering (CIGR), Québec, QC, Canada, 13–17 June 2010. [Google Scholar]
  18. Li, S.; Ren, B.; Yang, H.; Yang, Y.; Ji, H.; Ni, J. Effect of Cold Stress with Different Intensities on HSP70 Expression in Wistar Rat Muscle, Spleen and Liver. Chin. J. Appl. Environ. Biol. 2006, 12, 235–238. [Google Scholar]
  19. Myer, R.; Bucklin, R. Influence of Hot-Humid Environment on Growth Performance and Reproduction of Swine. Document AN107, Extension, Institute of Food and Agricultural Sciences, 2001, University of Florida. Available online: http://edis.ifas.ufl.edu/an107 (accessed on 30 September 2021).
  20. Riva, G.; Pedretti, E.F.; Fabbri, C. Utilization of a heat pump in pig breeding for energy saving and climate and ammonia control. J. Agric. Eng. Res. 2000, 77, 449–455. [Google Scholar] [CrossRef]
  21. Choi, H.C.; Song, J.; Na, J.C.; Kim, M.J.; Bang, H.T.; Kang, H.G.; Park, S.B.; Chae, H.S.; Suh, O.S.; Yoo, Y.S.; et al. Evaluation on Cooling Effects of Geothermal Heat Pump System in Farrowing House. J. Anim. Environ. Sci. 2010, 16, 99–108. [Google Scholar]
  22. Mustafa Omer, A. Ground-Source Heat Pumps Systems and Applications. Renew. Sustain. Energy Rev. 2008, 12, 344–371. [Google Scholar] [CrossRef]
  23. National Oceanic and Atmospheric Administration (NOAA). Livestock Hot Weather Stress. Operations Manual Letter C-31-76; Department of Commerce, NOAA, National Weather Service Central Region: Kansas City, KA, USA, 1976.
  24. Man, Y.; Yang, H.; Wang, J.; Fang, Z. In Situ Operation Performance Test of Ground Coupled Heat Pump System for Cooling and Heating Provision in Temperate Zone. Appl. Energy 2012, 97, 913–920. [Google Scholar] [CrossRef]
  25. Aikins, K.A.; Choi, J.M. Current Status of the Performance of GSHP (Ground Source Heat Pump) Units in the Republic of Korea. Energy 2012, 47, 77–82. [Google Scholar] [CrossRef]
  26. Dilawar, M.A.; Saturno, J.F.L.; Mun, H.-S.; Kim, D.-H.; Jeong, M.-G.; Yang, C.-J. Influence of Two Plant Extracts on Broiler Performance, Oxidative Stability of Meat and Odorous Gas Emissions from Excreta. Ann. Anim. Sci. 2019, 19, 1099–1113. [Google Scholar] [CrossRef] [Green Version]
  27. Ni, J.-Q.; Heber, A.J.; Lim, T.-T. Ammonia and hydrogen sulfide in swine production. In Air Quality and Livestock Farming; CRC Press: Boca Raton, FL, USA, 2017; ISBN 978-1-315-73833-8. [Google Scholar]
  28. Cambra-López, M.; Hermosilla, T.; Lai, H.T.L.; Aarnink, A.J.A.; Ogink, N.W.M. Particulate Matter Emitted from Poultry and Pig Houses: Source Identification and Quantification. Trans. ASABE 2011, 54, 629–642. [Google Scholar] [CrossRef] [Green Version]
  29. Kang, D.; Kim, J.-E. Fine, Ultrafine, and Yellow Dust: Emerging Health Problems in Korea. J. Korean Med. Sci. 2014, 29, 621–622. [Google Scholar] [CrossRef] [Green Version]
  30. Subasi, N.T. Formaldehyde advantages and disadvantages: Usage Areas and Harmful E_ects on Human Beings. In Biochemical Toxicology-Heavy Materials and Nanomaterials; Ince, M., Kaplan Ince, O., Ondrasek, G., Eds.; IntechOpen: London, UK, 2020. [Google Scholar]
  31. Pulat, E.; Coskun, S.; Unlu, K.; Yamankaradeniz, N. Experimental Study of Horizontal Ground Source Heat Pump Performance for Mild Climate in Turkey. Energy 2009, 34, 1284–1295. [Google Scholar] [CrossRef]
  32. Kim, Y.S.; Kim, S.W.; Weaver, M.A.; Lee, C.Y. Increasing the Pig Market Weight: World Trends, Expected Consequences and Practical Considerations. Asian-Australas. J. Anim. Sci. 2005, 18, 590–600. [Google Scholar] [CrossRef]
  33. Rauw, W.M.; Mayorga, E.J.; Lei, S.M.; Dekkers, J.C.M.; Patience, J.F.; Gabler, N.K.; Lonergan, S.M.; Baumgard, L.H. Effects of Diet and Genetics on Growth Performance of Pigs in Response to Repeated Exposure to Heat Stress. Front. Genet. 2017, 8, 155. [Google Scholar] [CrossRef] [Green Version]
Figure 1. Schematic view of the experimental pig house.
Figure 1. Schematic view of the experimental pig house.
Applsci 11 10778 g001
Figure 2. Schematic view of the geothermal heat pump and geothermal monitoring system. The red coloured pipes show hot water and the blue colour shows cold water. * Emergency water supply.
Figure 2. Schematic view of the geothermal heat pump and geothermal monitoring system. The red coloured pipes show hot water and the blue colour shows cold water. * Emergency water supply.
Applsci 11 10778 g002
Figure 3. GHP system with a water tank and pipes installed at the pig farm.
Figure 3. GHP system with a water tank and pipes installed at the pig farm.
Applsci 11 10778 g003
Figure 4. Effect of the GHP cooling mode on the temperature–humidity index (THI). The data are presented as the mean ± SEM. a,b Values with different superscripts within the same bars differ significantly (p < 0.05).
Figure 4. Effect of the GHP cooling mode on the temperature–humidity index (THI). The data are presented as the mean ± SEM. a,b Values with different superscripts within the same bars differ significantly (p < 0.05).
Applsci 11 10778 g004
Figure 5. Effect of the GHP cooling mode on the ammonia (NH3) concentration. The data are presented as the mean ± SEM. a,b Values with different superscripts within the same bars differ significantly (p < 0.05).
Figure 5. Effect of the GHP cooling mode on the ammonia (NH3) concentration. The data are presented as the mean ± SEM. a,b Values with different superscripts within the same bars differ significantly (p < 0.05).
Applsci 11 10778 g005
Table 1. Diet formulae and chemical composition of the experimental diets.
Table 1. Diet formulae and chemical composition of the experimental diets.
Weaning Pigs
0–5 Weeks
Growing Pigs
5–9 Weeks
Finishing Pigs
10–19 Weeks
Ingredients (% as fed basis)
Yellow corn47.8551.3454.00
Rice bran14.007.009.00
Rapeseed oil 0.001.723.00
DDGS 0.006.006.00
Soybean meal22.1021.8018.00
Limestone0.700.861.00
Calcium Phosphate0.700.100.20
Salt0.150.300.30
Vit-min premix 10.500.450.20
Animal fat7.006.784.86
Molasses2.002.502.50
Amino Acid additive5.001.150.94
Analyzed composition (g/kg dry matter)
Dry matter879876881
Crude protein190180170
Crude fat434444
Crude fiber393838
Ca 7.08.08.0
Available P4.43.43.4
Lysine10.3510.2010.10
Methionine5.33.73.1
1 Vit-min premix contained following nutrients/kg: vitamin D3, 800 IU; vitamin A, 6000 IU; vitamin K3, 2 mg; vitamin E, 20 IU; thiamin, 2 mg; riboflavin, 4 mg; vitamin B12, 1 mg; niacin, 10 mg; pantothenic acid, 11 mg; biotin, 0.02 mg; vitamin B6, 20 IU; manganese, 90 mg; copper, 21 mg; iron (ferrous), 100 mg; zinc, 60 mg; iodine, 1.0 mg; cobalt, 0.3 mg; selenium, 0.3 mg.
Table 2. Effect of the GHP cooling mode on the inside temperature of the pig house.
Table 2. Effect of the GHP cooling mode on the inside temperature of the pig house.
ItemsOutsideControlGHPSEMp-Value
Weaning28.7025.8525.320.210.0495
Growing27.3124.3123.850.210.2134
Early Finishing31.1227.76 a22.93 b0.15<0.0001
Late Finishing26.4922.20 a20.28 b0.17<0.0001
Average28.4025.07 a23.84 b0.22<0.0001
a,b Values within the same row with different letters differ significantly.
Table 3. Heat pump water flow temperature and the coefficient of performance (COP) of the GHP cooling mode.
Table 3. Heat pump water flow temperature and the coefficient of performance (COP) of the GHP cooling mode.
PeriodsHeat Pump Water Flow Temperature (°C)DifferenceHeat Pump Consumption
(kWh)
COP
OutflowInflow
Weaning26.1133.557.4444.804.10
Growing20.2234.9614.7444.204.46
Early Finishing19.9231.7511.8348.204.50
Late Finishing20.1629.309.1444.604.40
Average21.6032.3910.7945.454.36
Table 4. Effect of the GHP cooling mode on the formaldehyde (ppm), PM2.5 (µg/m3) and hydrogen sulfide (H2S) (ppb) in the pig house.
Table 4. Effect of the GHP cooling mode on the formaldehyde (ppm), PM2.5 (µg/m3) and hydrogen sulfide (H2S) (ppb) in the pig house.
ItemsControlGHPSEMp-Value
Particulate matter (PM2.5 µg/m3)
Weaning22.5121.862.440.8610
Growing16.2515.322.390.7932
Early Finishing34.1731.974.900.7514
Late finishing25.4924.943.670.9223
Average25.0524.071.900.7163
Formaldehyde (ppm)
Weaning0.070.100.010.0611
Growing0.080.100.010.2638
Early Finishing0.11 a0.05 b0.020.0431
Late Finishing0.080.130.010.0595
Average0.090.090.010.5051
Hydrogen sulfide (ppb)
Weaning13.00 a0.14 b0.010.0002
Growing7.00 a0.03 b0.020.0325
Early Finishing5.00 a1.28 b0.010.0199
Late Finishing16.00 a0.21 b0.100.0341
Average10.00 a0.44 b0.010.0011
a,b Values within the same row with different letters differ significantly.
Table 5. Effect of the GHP cooling mode on the growth performance parameters.
Table 5. Effect of the GHP cooling mode on the growth performance parameters.
ParameterControlGHPSEMp Value
0–5 weeks
Initial body weight (kg)6.186.170.370.9910
Final body weight (kg)23.7425.840.880.1250
Weight gain (kg)17.5619.670.770.0850
Feed intake (kg)26.60 b31.10 a1.260.0350
Feed conversion ratio1.521.590.060.4390
6–9 weeks
Final body weight (kg)48.5351.351.660.2490
Weight gain (kg)24.7925.510.910.7250
Feed intake (kg)51.83 b52.71 a2.210.0005
Feed conversion ratio2.112.070.050.6700
10–14 weeks
Final body weight (kg)75.61 b82.58 a1.880.0220
Weight gain (kg)27.0931.231.010.0840
Feed intake (kg)81.29 b91.62 a2.420.0140
Feed conversion ratio3.032.940.140.8210
15–19 weeks
Final body weight (kg)108.47 b118.17 a2.560.0240
Weight gain (kg)32.8635.580.820.2760
Feed intake (kg)101.16 b120.53 a2.760.0008
Feed conversion ratio3.10 b3.39 a0.130.0280
0–19 weeks
Final body weight (kg)108.47 b118.17 a2.560.0240
Weight gain (kg)102.29 b111.99 a2.470.0170
Feed intake (kg)260.88295.966.960.0780
Feed conversion ratio2.562.640.050.4390
a,b Values within the same row with different letters differ significantly.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Mun, H.-S.; Dilawar, M.A.; Rathnayake, D.; Chung, I.-B.; Kim, C.-D.; Ryu, S.-B.; Park, K.-W.; Lee, S.-R.; Yang, C.-J. Effect of a Geothermal Heat Pump in Cooling Mode on the Housing Environment and Swine Productivity Traits. Appl. Sci. 2021, 11, 10778. https://doi.org/10.3390/app112210778

AMA Style

Mun H-S, Dilawar MA, Rathnayake D, Chung I-B, Kim C-D, Ryu S-B, Park K-W, Lee S-R, Yang C-J. Effect of a Geothermal Heat Pump in Cooling Mode on the Housing Environment and Swine Productivity Traits. Applied Sciences. 2021; 11(22):10778. https://doi.org/10.3390/app112210778

Chicago/Turabian Style

Mun, Hong-Seok, Muhammad Ammar Dilawar, Dhanushka Rathnayake, Il-Byung Chung, Chong-Dae Kim, Sang-Bum Ryu, Kwang-Woo Park, Sang-Ro Lee, and Chul-Ju Yang. 2021. "Effect of a Geothermal Heat Pump in Cooling Mode on the Housing Environment and Swine Productivity Traits" Applied Sciences 11, no. 22: 10778. https://doi.org/10.3390/app112210778

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop