Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (70)

Search Parameters:
Keywords = high photon count rate

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
25 pages, 3282 KB  
Review
Linear-Mode Gain HgCdTe Avalanche Photodiodes for Weak-Target Spaceborne Photonic System
by Hui Yu, Zhichao Zhang, Ming Liu, Weirong Xing, Qing Wu, Yi Zhang, Weiting Zhang, Jialin Xu and Qiguang Tan
Photonics 2025, 12(8), 829; https://doi.org/10.3390/photonics12080829 - 20 Aug 2025
Viewed by 263
Abstract
Spectroscopic observations of Earth-like exoplanets and ultra-faint galaxies–top scientific priorities for the coming decades–involve measuring broadband signals at rates of only a few photons per square meter per hour. This imposes exceptional requirements on the detector performance, necessitating dark currents below 1 e [...] Read more.
Spectroscopic observations of Earth-like exoplanets and ultra-faint galaxies–top scientific priorities for the coming decades–involve measuring broadband signals at rates of only a few photons per square meter per hour. This imposes exceptional requirements on the detector performance, necessitating dark currents below 1 e/pixel/kilo second, read noise under 1 e/pixel/frame, and the ability to handle large-format arrays–capabilities that are not yet met by most existing infrared detectors. In addition, spaceborne LiDAR systems require photodetectors with exceptional sensitivity, compact size, low power consumption, and multi-channel capability to facilitate long-range range finding, topographic mapping, and active spectroscopy without increasing the instrument burden. MCT Avalanche photodiodes arrays offer high internal gain, pixelation, and photon-counting performance across SW to MW wavelengths needed for multi-beam and multi-wavelength measurements, marking them as a critical enabling technology for next-generation planetary and Earth science LiDAR missions. This work reports the latest progress in developing Hg1−xCdxTe linear-mode e-APDs at premier industrial research institutions, including relevant experimental data, simulations and major project planning. Related studies are summarized to demonstrate the practical and iterative approach for device fabrication, which have a transformative impact on the evolution of this discipline. Full article
(This article belongs to the Special Issue Emerging Trends in Photodetector Technologies)
Show Figures

Figure 1

13 pages, 3812 KB  
Article
Generation of Four-Beam Output in a Bonded Nd:YAG/Cr4+:YAG Laser via Fiber Splitter Pumping
by Qixiu Zhong, Dongdong Meng, Zhanduo Qiao, Wenqi Ge, Tieliang Zhang, Zihang Zhou, Hong Xiao and Zhongwei Fan
Photonics 2025, 12(8), 760; https://doi.org/10.3390/photonics12080760 - 29 Jul 2025
Viewed by 280
Abstract
To address the poor thermal performance and low output efficiency of conventional solid-state microchip lasers, this study proposes and implements a bonded Nd:YAG/Cr4+:YAG laser based on fiber splitter pumping. Experimental results demonstrate that at a 4.02 mJ pump pulse energy and [...] Read more.
To address the poor thermal performance and low output efficiency of conventional solid-state microchip lasers, this study proposes and implements a bonded Nd:YAG/Cr4+:YAG laser based on fiber splitter pumping. Experimental results demonstrate that at a 4.02 mJ pump pulse energy and a 100 Hz repetition rate, the system achieves four linearly polarized output beams with an average pulse energy of 0.964 mJ, a repetition rate of 100 Hz, and an optical-to-optical conversion efficiency of 23.98%. The energy distribution ratios for the upper-left, lower-left, upper-right, and lower-right beams are 22.61%, 24.46%, 25.50%, and 27.43%, with pulse widths of 2.184 ns, 2.193 ns, 2.205 ns, and 2.211 ns, respectively. As the optical axis distance increases, the far-field spot pattern transitions from a single circular profile to four fully separated spots, where the lower-right beam exhibits beam quality factors of Mx2 = 1.181 and My2 = 1.289. Simulations at a 293.15 K coolant temperature and a 4.02 mJ pump energy reveal that split pumping reduces the volume-averaged temperature rise in Nd:YAG by 28.81% compared to single-beam pumping (2.57 K vs. 3.61 K), decreases the peak temperature rise by 66.15% (6.97 K vs. 20.59 K), and suppresses peak-to-peak temperature variation by 78.6% (1.34 K vs. 6.26 K). Compared with existing multi-beam generation methods, the fiber splitter approach offers integrated advantages—including compact size, low cost, high energy utilization, superior beam quality, and elevated damage thresholds—and thus shows promising potential for automotive multi-point ignition, multi-beam single-photon counting LiDAR, and laser-induced breakdown spectroscopy (LIBS) online analysis. Full article
(This article belongs to the Special Issue Laser Technology and Applications)
Show Figures

Figure 1

17 pages, 1027 KB  
Review
Photon Detector Technology for Laser Ranging: A Review of Recent Developments
by Zhihui Li, Xin Jin, Changfu Yuan and Kai Wang
Coatings 2025, 15(7), 798; https://doi.org/10.3390/coatings15070798 - 8 Jul 2025
Viewed by 954
Abstract
Laser ranging technology holds a key position in the military, aerospace, and industrial fields due to its high precision and non-contact measurement characteristics. As a core component, the performance of the photon detector directly determines the ranging accuracy and range. This paper systematically [...] Read more.
Laser ranging technology holds a key position in the military, aerospace, and industrial fields due to its high precision and non-contact measurement characteristics. As a core component, the performance of the photon detector directly determines the ranging accuracy and range. This paper systematically reviews the technological development of photonic detectors for laser ranging, with a focus on analyzing the working principles and performance differences of traditional photodiodes [PN (P-N junction photodiode), PIN (P-intrinsic-N photodiode), and APD (avalanche photodiode)] (such as the high-frequency response characteristics of PIN and the internal gain mechanism of APD), as well as their applications in short- and medium-range scenarios. Additionally, this paper discusses the unique advantages of special structures such as transmitting junction-type and Schottky-type detectors in applications like ultraviolet light detection. This article focuses on photon counting technology, reviewing the technological evolution of photomultiplier tubes (PMTs), single-photon avalanche diodes (SPADs), and superconducting nanowire single-photon detectors (SNSPDs). PMT achieves single-photon detection based on the external photoelectric effect but is limited by volume and anti-interference capability. SPAD achieves sub-decimeter accuracy in 100 km lidars through Geiger mode avalanche doubling, but it faces challenges in dark counting and temperature control. SNSPD, relying on the characteristics of superconducting materials, achieves a detection efficiency of 95% and a dark count rate of less than 1 cps in the 1550 nm band. It has been successfully applied in cutting-edge fields such as 3000 km satellite ranging (with an accuracy of 8 mm) and has broken through the near-infrared bottleneck. This study compares the differences among various detectors in core indicators such as ranging error and spectral response, and looks forward to the future technical paths aimed at improving the resolution of photon numbers and expanding the full-spectrum detection capabilities. It points out that the new generation of detectors represented by SNSPD, through material and process innovations, is promoting laser ranging to leap towards longer distances, higher precision, and wider spectral bands. It has significant application potential in fields such as space debris monitoring. Full article
Show Figures

Graphical abstract

33 pages, 5307 KB  
Article
SiPM Developments for the Time-Of-Propagation Detector of the Belle II Experiment
by Flavio Dal Corso, Jakub Kandra, Roberto Stroili and Ezio Torassa
Sensors 2025, 25(13), 4018; https://doi.org/10.3390/s25134018 - 27 Jun 2025
Viewed by 318
Abstract
Belle II is a particle physics experiment working at an high luminosity collider within a hard irradiation environment. The Time-Of-Propagation detector, aimed at the charged particle identification, surrounds the Belle II tracking detector on the barrel part. This detector is composed by 16 [...] Read more.
Belle II is a particle physics experiment working at an high luminosity collider within a hard irradiation environment. The Time-Of-Propagation detector, aimed at the charged particle identification, surrounds the Belle II tracking detector on the barrel part. This detector is composed by 16 modules, each module contains a finely fused silica bar, coupled to microchannel plate photomultiplier tube (MCP-PMT) photo-detectors and readout by high-speed electronics. The MCP-PMT lifetime at the nominal collider luminosity is about one year, this is due to the high photon background degrading the quantum efficiency of the photocathode. An alternative to these MCP-PMTs is multi-pixel photon counters (MPPC), known as silicon photomultipliers (SiPM). The SiPMs, in comparison to MCP-PMTs, have a lower cost, higher photon detection efficiency and are unaffected by the presence of a magnetic field, but also have a higher dark count rate that rapidly increases with the integrated neutron flux. The dark count rate can be mitigated by annealing the damaged devices and/or operating them at low temperatures. We tested SiPMs, with different dimensions and pixel sizes from different producers, to study their time resolution (the main constraint that has to satisfy the photon detector) and to understand their behavior and tolerance to radiation. For these studies we irradiated the devices to radiation up to 5×10111 MeV neutrons equivalent (neq) per cm2 fluences; we also started studying the effect of annealing on dark count rates. We performed several measurements on these devices, on top of the dark count rate, at different conditions in terms of overvoltage and temperatures. These measurements are: IV-curves, amplitude spectra, time resolution. For the last two measurements we illuminated the devices with a picosecond pulsed laser at very low intensities (with a number of detected photons up to about twenty). We present results mainly on two types of SiPMs. A new SiPM prototype developed in collaboration with FBK with the aim of improving radiation hardness, is expected to be delivered in September 2025. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

13 pages, 3137 KB  
Article
Studies and Rejection of Intercrystal Crosstalk on FPGA in a High-Energy Photon-Counting System
by Jiahao Chang, Huaxia Zhang, Shibo Jiang, Zhifang Wu and Shuo Xu
Appl. Sci. 2025, 15(11), 6050; https://doi.org/10.3390/app15116050 - 28 May 2025
Viewed by 426
Abstract
Intercrystal scatter reduces system sensitivity and spatial resolution, a phenomenon that has been extensively studied in positron emission tomography (PET) systems. However, the issue is even more significant in high-energy systems. The purpose of this study is to propose a practical crosstalk rejection [...] Read more.
Intercrystal scatter reduces system sensitivity and spatial resolution, a phenomenon that has been extensively studied in positron emission tomography (PET) systems. However, the issue is even more significant in high-energy systems. The purpose of this study is to propose a practical crosstalk rejection technique and demonstrate its applicability in high-energy photon-counting systems. The effect of inter-crystal scattering interactions between 60Co γ photons and lutetium yttrium oxyorthosilicate (LYSO) scintillator crystals is investigated through Monte Carlo simulations conducted using the Geant4 toolkit. To suppress the crosstalk phenomenon, a field-programmable gate array (FPGA)-based algorithm is proposed to suppress inter-crystal scattering events, characterized by a time window of 5 nanoseconds and detector window sizes of one or two. The 250 mm Fe steel penetration model is used to evaluate the proposed algorithm, showing improved radiation image quality, particularly with a detector window size of two, which performs better under low-count-rate conditions. Laboratory testing indicates that the proposed algorithm can enhance steel penetration (SP) by 60–70 mm of Fe when compared to the existing current integration system under the same settings. The suggested method has been proven effective in producing higher-quality images and demonstrates good adaptability by adapting the detector window width according to different system count rates. Full article
Show Figures

Figure 1

15 pages, 2420 KB  
Article
Performance Comparison of Multipixel Biaxial Scanning Direct Time-of-Flight Light Detection and Ranging Systems With and Without Imaging Optics
by Konstantin Albert, Manuel Ligges, Andre Henschke, Jennifer Ruskowski, Menaka De Zoysa, Susumu Noda and Anton Grabmaier
Sensors 2025, 25(10), 3229; https://doi.org/10.3390/s25103229 - 21 May 2025
Viewed by 605
Abstract
The laser pulse detection probability of a scanning direct time-of-flight light detection and ranging (LiDAR) measurement is evaluated based on the optical signal distribution on a multipixel single photon avalanche diode (SPAD) array. These detectors intrinsically suffer from dead-times after the successful detection [...] Read more.
The laser pulse detection probability of a scanning direct time-of-flight light detection and ranging (LiDAR) measurement is evaluated based on the optical signal distribution on a multipixel single photon avalanche diode (SPAD) array. These detectors intrinsically suffer from dead-times after the successful detection of a single photon and, thus, allow only for limited counting statistics when multiple returning laser photons are imaged on a single pixel. By blurring the imaged laser spot, the transition from single-pixel statistics with high signal intensity to multipixel statistics with less signal intensity is examined. Specifically, a comparison is made between the boundary cases in which (i) the returning LiDAR signal is focused through optics onto a single pixel and (ii) the detection is performed without lenses using all available pixels on the sensor matrix. The omission of imaging optics reduces the overall system size and minimizes optical transfer losses, which is crucial given the limited laser emission power due to safety standards. The investigation relies on a photon rate model for interfering (background) and signal light, applied to a simulated first-photon sensor architecture. For single-shot scenarios that reflect the optimal use of the time budget in scanning LiDAR systems, the lens-less and blurred approaches can achieve comparable or even superior results to the focusing system. This highlights the potential of fully solid-state scanning LiDAR systems utilizing optical phase arrays or multidirectional laser chips. Full article
(This article belongs to the Special Issue SPAD-Based Sensors and Techniques for Enhanced Sensing Applications)
Show Figures

Graphical abstract

26 pages, 47051 KB  
Article
Dynamic Light Path and Bidirectional Reflectance Effects on Solar Noise in UAV-Borne Photon-Counting LiDAR
by Kuifeng Luan, Jinhui Zheng, Wei Kong, Weidong Zhu, Lizhe Zhang, Peiyao Zhang and Lin Liu
Remote Sens. 2025, 17(10), 1708; https://doi.org/10.3390/rs17101708 - 13 May 2025
Viewed by 568
Abstract
Accurate solar background noise modeling in island-reef LiDAR surveys is hindered by anisotropic coastal reflectivity and dynamic light paths, which isotropic models fail to address. We propose BNR-B, a bidirectional reflectance distribution function (BRDF)-based noise model that integrates solar-receiver geometry with micro-facet scattering [...] Read more.
Accurate solar background noise modeling in island-reef LiDAR surveys is hindered by anisotropic coastal reflectivity and dynamic light paths, which isotropic models fail to address. We propose BNR-B, a bidirectional reflectance distribution function (BRDF)-based noise model that integrates solar-receiver geometry with micro-facet scattering dynamics. Validated via single-photon LiDAR field tests on diverse coastal terrains at Jiajing Island, China, BNR-B reveals the following: (1) Solar zenith/azimuth angles non-uniformly modulate noise fields—higher solar zenith angles reduce noise intensity and homogenize spatial distribution; (2) surface reflectivity linearly correlates with noise rate (R2 > 0.99), while roughness governs scattering directionality through micro-facet redistribution. BNR-B achieves 28.6% higher noise calculation accuracy than Lambertian models, with a relative phase error < 2% against empirical data. As the first BRDF-derived solar noise correction framework for coastal LiDAR, it addresses critical limitations of isotropic assumptions by resolving directional noise modulation. The model’s adaptability to marine–terrestrial interfaces enhances precision in coastal monitoring and submarine mapping, offering transformative potential for geospatial applications requiring photon-counting LiDAR in complex environments. Key innovations include dynamic coupling of geometric optics and surface scattering physics, enabling robust spatiotemporal noise quantification, critical for high-resolution terrain reconstruction. Full article
Show Figures

Figure 1

9 pages, 1304 KB  
Article
Coronary Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increment: Impact on Calcium Severity Classifications
by Marco Kaldas, Jonathan Weber, Roosha Parikh, Karli Pipitone, Karen Chau, Doosup Shin, Rick Volleberg, Ziad Ali and Omar K. Khalique
J. Clin. Med. 2025, 14(9), 2875; https://doi.org/10.3390/jcm14092875 - 22 Apr 2025
Viewed by 693
Abstract
Background: Cardiovascular risk assessment relies heavily on coronary calcium scoring. With an emphasis on varying slice increments, this study investigates the effectiveness of true and virtual non-contrast reconstructions on photon-counting CT. Reconstruction methods’ effects on calcium severity classifications are critical to the improvement [...] Read more.
Background: Cardiovascular risk assessment relies heavily on coronary calcium scoring. With an emphasis on varying slice increments, this study investigates the effectiveness of true and virtual non-contrast reconstructions on photon-counting CT. Reconstruction methods’ effects on calcium severity classifications are critical to the improvement in imaging techniques. Methods: This study comprised 77 participants (mean age: 63 ± 10 years, 43% female), of whom 0 had a coronary artery calcium score (CACS) of zero. In contrast to true non-contrast (TNC) 3 × 3 mm, the reconstructions included TNC 3 × 1.5 mm, virtual non-contrast (VNC) 3 × 3 mm, and VNC 3 × 1.5 mm. Agatston units served as the basis for classifications into standard clinical diagnostic categories. Results: High concordance between acquisition types was revealed by interclass correlation values (0.97–0.99). Comparing TNC 3 × 1.5 mm reconstructions to their VNC counterparts, misclassifications were less common (Cohen Kappa = 0.94). (K = 0.83–0.85). Significant differences in the average calcium scores and rates of misclassification highlighted the impact of reconstruction methods on precise evaluations. Conclusions: VNC methods demonstrated high agreement; however, with a small rate of misclassifications as compared to the gold standard method. VNC CACS may help optimize workflows but may need differing cutoffs as compared to traditional methods. Full article
(This article belongs to the Section Cardiovascular Medicine)
Show Figures

Figure 1

11 pages, 2273 KB  
Article
Demonstration of Quantum Polarized Microscopy Using an Entangled-Photon Source
by Mousume Samad, Maki Shimizu and Yasuto Hijikata
Photonics 2025, 12(2), 127; https://doi.org/10.3390/photonics12020127 - 31 Jan 2025
Cited by 1 | Viewed by 1603
Abstract
With the advancement of non-classical light sources such as single-photon and entangled-photon sources, innovative microscopy based on quantum principles has been proposed for traditional microscopy. This paper introduces the experimental demonstration of a quantum polarization microscopic technique that incorporates a quantum-entangled photon source. [...] Read more.
With the advancement of non-classical light sources such as single-photon and entangled-photon sources, innovative microscopy based on quantum principles has been proposed for traditional microscopy. This paper introduces the experimental demonstration of a quantum polarization microscopic technique that incorporates a quantum-entangled photon source. Although the point that employs the variation in polarization angle due to reflection or transmission at the sample is similar to classical polarization microscopy, the method for constructing the image contrast is significantly different. The image contrast is constructed by the coincidence count of signal and idler photons. In the case that the coincidence count is recorded from both the signal and idler photons, the photon statistics resemble a thermal state, similar to the blackbody radiation, but with a significantly higher peak intensity in the second-order autocorrelation function at zero delay that is derived from the coincidence count, while, when the coincidence count is taken from either the signal or idler photon only, although the photon state exhibits a thermal state again, the photon statistics become more dispersive and result in a lower peak intensity of the autocorrelation function. These different thermal states can be switched by slightly changing the photon polarization, which is suddenly aroused within a narrow range of the analyzer angle. The autocorrelation function g2(0) at the thermal state exhibits a sensitivity that is three times higher compared to the classical coincidence count rate, and this concept can be effectively utilized to enhance the contrast of the image. One of the key achievements of our proposed method is ensuring a low power of illumination (in the order of Pico-joules) for constructing the image. In addition, the robustness without any precise setup is also favorable for practical use. This polarization microscopic technique can provide a superior imaging technique compared to the classical method, opening a new frontier for research in material sciences, biology, and other fields requiring high-resolution imaging. Full article
(This article belongs to the Special Issue Photonics: 10th Anniversary)
Show Figures

Figure 1

13 pages, 4259 KB  
Article
Virtual Monoenergetic Imaging of Thoracoabdominal Computed Tomography Angiography on Photon-Counting Detector Computertomography: Assessment of Image Quality and Leveraging Low-keV Series for Salvaging Suboptimal Contrast Acquisitions
by Katharina Rippel, Josua A. Decker, Jan Luitjens, Osama Habeeballah, Stefanie Bette, Franziska Braun, Thomas J. Kroencke and Christian Scheurig-Muenkler
Diagnostics 2024, 14(24), 2843; https://doi.org/10.3390/diagnostics14242843 - 17 Dec 2024
Viewed by 801
Abstract
Background: The aim of this study was to assess the possibility of image improvement of ECG-gated, high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta before transaortic valve replacement (TAVR) on a novel dual-source photon-counting detector CT (PCD-CT) in the setting of suboptimal [...] Read more.
Background: The aim of this study was to assess the possibility of image improvement of ECG-gated, high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta before transaortic valve replacement (TAVR) on a novel dual-source photon-counting detector CT (PCD-CT) in the setting of suboptimal low-contrast attenuation. Methods: Continuously examined patients who underwent an ECG-gated, high-pitch CTA of the aorta on a PCD-CT with a contrast decrease of at least 50% between the ascending aorta and the common femoral arteries (CFA) were included. Patient characteristics were documented. Virtual monoenergetic imaging (VMI) reconstructions with three keV settings were generated. CT values and noise were measured for five vascular segments of the aorta and the CFA. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Two independent board-certified radiologists rated the images with the focus on vascular attenuation, vessel sharpness, and image quality using a 5-point Likert scale. Results: Fifty-five patients (mean age 77.4 ± 8.5 years; 15 women) were included. The SNR was significantly higher at 40 and 45 keV VMI compared to reference 70 keV (p < 0.001 and p = 0.005, respectively). The same was shown for the CNR (p < 0.001 and p = 0.0049, respectively). Subjective image evaluation showed a significant increase in vessel attenuation in the lower keV reconstructions, while the overall image quality decreased only slightly. Furthermore, 50% (8/16) of primarily non-diagnostic scans were considered diagnostic when using low-keV reconstructions (p > 0.05). Conclusions: ECG-gated CTA of the aorta in high-pitch mode on PCD-CT with suboptimal contrast enhancement at the level of the CFA can be salvaged by using low-keV VMI. This implies the possibility of radiation dose reduction by eliminating the need for repeat scans. Full article
(This article belongs to the Section Medical Imaging and Theranostics)
Show Figures

Figure 1

14 pages, 3976 KB  
Article
The Impact of Afterpulsing Effects in Single-Photon Detectors on the Performance Metrics of Single-Photon Detection Systems
by Yuanfan Lai, Zongyao Shen, Yong Chen, Jindong Wang, Jianping Guo and Zhengjun Wei
Photonics 2024, 11(11), 1074; https://doi.org/10.3390/photonics11111074 - 15 Nov 2024
Cited by 2 | Viewed by 1782
Abstract
A single-photon detection system based on InGaAs SPADs is a high-precision optical measurement system capable of detecting quantum-level optical signals. However, the afterpulsing effect when using InGaAs SPADs severely limits their practical utility. The impact of afterpulsing effects on the performance of systems [...] Read more.
A single-photon detection system based on InGaAs SPADs is a high-precision optical measurement system capable of detecting quantum-level optical signals. However, the afterpulsing effect when using InGaAs SPADs severely limits their practical utility. The impact of afterpulsing effects on the performance of systems based on this type of detector can no longer be ignored. Therefore, this paper provides a detailed analysis of the measurement errors induced by afterpulsing effects and proposes a correction method based on a power-law model. This method analyzes the probability distribution of afterpulsing effects using the power-law model and improves the expressions for the system’s average count rate and signal-to-noise ratio by calculating the average number of afterpulses within the average response time. The influence of afterpulse probability and dead time on the system’s average count rate is also analyzed. This afterpulse correction method mitigates the measurement errors caused by afterpulsing effects, thereby enhancing the system’s measurement accuracy. Full article
(This article belongs to the Section Optoelectronics and Optical Materials)
Show Figures

Figure 1

11 pages, 1658 KB  
Article
Beyond the Classical Janzen–Connell Hypothesis: The Role of the Area Under the Parent Tree Crown of Manilkara zapota
by Oscar Antonio Euan-Quiñones, Helbert Mena-Martín, Patricia Herrera-Pérez, Ramiro Alexandro Cetina-Pérez, San German Bautista-Parra and Horacio Salomon Ballina-Gomez
Stresses 2024, 4(4), 762-772; https://doi.org/10.3390/stresses4040050 - 14 Nov 2024
Cited by 1 | Viewed by 1450
Abstract
The effect of the parent tree on seedling recruitment has been studied in various research studies. The Janzen–Connell (JC) hypothesis states that the closer the seedlings are to the source tree, the greater the risk of mortality and/or impact from pathogens and herbivores. [...] Read more.
The effect of the parent tree on seedling recruitment has been studied in various research studies. The Janzen–Connell (JC) hypothesis states that the closer the seedlings are to the source tree, the greater the risk of mortality and/or impact from pathogens and herbivores. Despite the extensive existing literature, there are not many studies that evaluate the influence of crown area, as well as the effects on leaf asymmetry, an important measure of biotic and abiotic stress. (1) This study evaluates the effect of distance from the parent tree and the crown’s area of influence on mortality, growth, and leaf asymmetry of Manilkara zapota seedlings, as well as insect herbivory and damage from leaf pathogens in a Mexican neotropical forest. (2) We selected 10 reproductive adult trees (Diameter at breast height, DBH ~ 10–25 cm) and established four 10 m × 1 m transects around each tree in four directions (north, south, east, and west). Each transect produced 10 quadrants of 1 m², and the quadrant where the shadow of the parent tree extended was marked as either under crown or crown-free. All M. zapota seedlings were counted in each quadrant. For one seedling in each quadrant, we recorded height, leaf asymmetry (LA), insect herbivory, and damage from leaf pathogens. Herbivory by insects, damage from leaf pathogens, and LA were only measured on the newest leaves. Mortality was determined after 9 months per quadrant, as well as light availability (photosynthetic photon flux density), temperature, and relative humidity. (3) We found that mortality and relative growth rate (RGRHeight) increased near and under the parent tree. Furthermore, LA decreased at greater distances from the parent tree and only outside the crown’s influence. Additionally, LA had a strong positive influence on damage caused by insect herbivory and leaf pathogens, impacting both more strongly under the crown. A high dependency of leaf pathogens on damage from insect herbivory was also recorded. Finally, the most frequent type of herbivory was that caused by chewing insects. (4) To our knowledge, we present one of the few studies that has addressed the JC hypothesis, considering not only the distance from the parent tree and seedling density but also the influence of the crown on the performance of M. zapota seedlings. Studies that consider the influence of the microenvironment are of fundamental importance for a comprehensive understanding of the JC hypothesis. Full article
(This article belongs to the Collection Feature Papers in Plant and Photoautotrophic Stresses)
Show Figures

Figure 1

18 pages, 1067 KB  
Article
Quantitative Analysis of Acquisition Speed of High-Precision FLIM Technologies via Simulation and Modeling
by Jinzheng Lu, Ling Miao, Jiaxing Wen, Qiang Li, Jingwei Chen, Qiang Yang, Xing Zhang, Jin Li, Yuchi Wu, Yue Yang, Sixin Wu, Wenbo Mo and Qiang Xiang
Photonics 2024, 11(10), 973; https://doi.org/10.3390/photonics11100973 - 17 Oct 2024
Cited by 1 | Viewed by 1548
Abstract
In practical applications such as cancer diagnosis and industrial detection, there is a critical demand for fast fluorescence lifetime imaging (Fast-FLIM). The Fast-FLIM systems suitable for complex environments are typically achieved by enhancing the hardware performance of time-correlated single-photon counting (TCSPC), with an [...] Read more.
In practical applications such as cancer diagnosis and industrial detection, there is a critical demand for fast fluorescence lifetime imaging (Fast-FLIM). The Fast-FLIM systems suitable for complex environments are typically achieved by enhancing the hardware performance of time-correlated single-photon counting (TCSPC), with an acquisition speed of about a few frames per second (fps). However, due to the limitation of single-photon acquisition, the imaging speed is still far from the demand of practical application. The synchroscan streak camera (SC) maps signals from the temporal dimension to the spatial dimension, effectively overcoming the long acquisition time caused by single-photon acquisition. This paper constructs a method to calculate the acquisition time for the TCSPC-FLIM and SC-FLIM systems, and it quantitatively compares the speed. The research demonstrates that the main factors limiting the acquisition speed of the FLIM systems are the photon emission rate, the photon counting rate, the required SNR, the dwell time, and the number of parallel channels. In high-quality and large-scale lifetime imaging, the acquisition speed of the SC-FLIM is at least 104 times faster than that of the TCSPC-FLIM. Therefore, the synchroscan streak camera has more significant potential to promote Fast-FLIM. Full article
(This article belongs to the Section Biophotonics and Biomedical Optics)
Show Figures

Figure 1

15 pages, 2064 KB  
Article
Research on the Depth Image Reconstruction Algorithm Using the Two-Dimensional Kaniadakis Entropy Threshold
by Xianhui Yang, Jianfeng Sun, Le Ma, Xin Zhou, Wei Lu and Sining Li
Sensors 2024, 24(18), 5950; https://doi.org/10.3390/s24185950 - 13 Sep 2024
Cited by 1 | Viewed by 1023
Abstract
The photon-counting light laser detection and ranging (LiDAR), especially the Geiger mode avalanche photon diode (Gm-APD) LiDAR, can obtain three-dimensional images of the scene, with the characteristics of single-photon sensitivity, but the background noise limits the imaging quality of the laser radar. In [...] Read more.
The photon-counting light laser detection and ranging (LiDAR), especially the Geiger mode avalanche photon diode (Gm-APD) LiDAR, can obtain three-dimensional images of the scene, with the characteristics of single-photon sensitivity, but the background noise limits the imaging quality of the laser radar. In order to solve this problem, a depth image estimation method based on a two-dimensional (2D) Kaniadakis entropy thresholding method is proposed which transforms a weak signal extraction problem into a denoising problem for point cloud data. The characteristics of signal peak aggregation in the data and the spatio-temporal correlation features between target image elements in the point cloud-intensity data are exploited. Through adequate simulations and outdoor target-imaging experiments under different signal-to-background ratios (SBRs), the effectiveness of the method under low signal-to-background ratio conditions is demonstrated. When the SBR is 0.025, the proposed method reaches a target recovery rate of 91.7%, which is better than the existing typical methods, such as the Peak-picking method, Cross-Correlation method, and the sparse Poisson intensity reconstruction algorithm (SPIRAL), which achieve a target recovery rate of 15.7%, 7.0%, and 18.4%, respectively. Additionally, comparing with the SPIRAL, the reconstruction recovery ratio is improved by 73.3%. The proposed method greatly improves the integrity of the target under high-background-noise environments and finally provides a basis for feature extraction and target recognition. Full article
(This article belongs to the Special Issue Application of LiDAR Remote Sensing and Mapping)
Show Figures

Figure 1

20 pages, 5507 KB  
Article
Robust Pixel Design Methodologies for a Vertical Avalanche Photodiode (VAPD)-Based CMOS Image Sensor
by Akito Inoue, Naoki Torazawa, Shota Yamada, Yuki Sugiura, Motonori Ishii, Yusuke Sakata, Taiki Kunikyo, Masaki Tamaru, Shigetaka Kasuga, Yusuke Yuasa, Hiromu Kitajima, Hiroshi Koshida, Tatsuya Kabe, Manabu Usuda, Masato Takemoto, Yugo Nose, Toru Okino, Takashi Shirono, Kentaro Nakanishi, Yutaka Hirose, Shinzo Koyama, Mitsuyoshi Mori, Masayuki Sawada, Akihiro Odagawa and Tsuyoshi Tanakaadd Show full author list remove Hide full author list
Sensors 2024, 24(16), 5414; https://doi.org/10.3390/s24165414 - 21 Aug 2024
Viewed by 1887
Abstract
We present robust pixel design methodologies for a vertical avalanche photodiode-based CMOS image sensor, taking account of three critical practical factors: (i) “guard-ring-free” pixel isolation layout, (ii) device characteristics “insensitive” to applied voltage and temperature, and (iii) stable operation subject to intense light [...] Read more.
We present robust pixel design methodologies for a vertical avalanche photodiode-based CMOS image sensor, taking account of three critical practical factors: (i) “guard-ring-free” pixel isolation layout, (ii) device characteristics “insensitive” to applied voltage and temperature, and (iii) stable operation subject to intense light exposure. The “guard-ring-free” pixel design is established by resolving the tradeoff relationship between electric field concentration and pixel isolation. The effectiveness of the optimization strategy is validated both by simulation and experiment. To realize insensitivity to voltage and temperature variations, a global feedback resistor is shown to effectively suppress variations in device characteristics such as photon detection efficiency and dark count rate. An in-pixel overflow transistor is also introduced to enhance the resistance to strong illumination. The robustness of the fabricated VAPD-CIS is verified by characterization of 122 different chips and through a high-temperature and intense-light-illumination operation test with 5 chips, conducted at 125 °C for 1000 h subject to 940 nm light exposure equivalent to 10 kLux. Full article
(This article belongs to the Special Issue Optoelectronic Functional Devices for Sensing Applications)
Show Figures

Figure 1

Back to TopTop